Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Synowiec, P. M." wg kryterium: Autor


Wyświetlanie 1-6 z 6
Tytuł:
Analysis of the pressure drop calculation method impact on the accuracy of the experimental results in the Koflo® static mixer
Analiza wpływu metody obliczeń spadku ciśnienia w mieszalniku statycznym Koflo® na dokładność odwzorowania wyników doświadczeń
Autorzy:
Stec, M.
Synowiec, P. M.
Powiązania:
https://bibliotekanauki.pl/articles/2073099.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Koflo® static mixer
pressure drop
CFD
mieszalnik statyczny Koflo®
spadek ciśnienia
Opis:
The presented paper is a continuation of previously one and it focuses on the validation of the developed Koflo static mixer numerical model (created for pressure drop predictions by use of CFD techniques) on the basis of experimental data. It also presents the new equation that can be used for pressure drop calculations and shows the comparison of different, commonly used static mixers types with the analyzed, unrecognized in the literature Koflo mixer.
Artykuł jest kontynuacją poprzedniej publikacji i skupia się na walidacji opracowanego modelu numerycznego mieszalnika statycznego Koflo (wykorzystywanego do określania spadków ciśnienia podczas przepływu cieczy jednorodnej w reżimie burzliwym) w oparciu o dane eksperymentalne. Podano nowe równanie do obliczania spadków ciśnienia podczas przepływu cieczy przez mieszalnik, a i przedstawiono porównanie innych komercyjnych mieszalników z analizowanym i dotychczas nierozpoznanym w literaturze mieszalnikiem Koflo.
Źródło:
Inżynieria i Aparatura Chemiczna; 2015, 4; 201--203
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical method effect on pressure drop estimation in the Koflo® static mixer
Wpływ metody numerycznej na estymację spadków ciśnienia w mieszalniku statycznym typu Koflo®
Autorzy:
Stec, M.
Synowiec, P. M.
Powiązania:
https://bibliotekanauki.pl/articles/2073035.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
static mixer
Koflo®
pressure drop
CFD
turbulent flow
mieszalnik statyczny
spadek ciśnienia
przepływ burzliwy
Opis:
Pressure drop determines the power required to pump the fluid through the mixer and enables the selection of proper pumping device. In the presented paper there was an attempt to determine the pressure drops over a static mixer using CFD methods and to validate the developed model upon the vendor’s correlation. The study involved one-phase flow in the turbulent regime (Re = 1000÷5000). The numerical and experimental approach was obtained using the Koflo® Static Mixer consisted of 12 motionless mixing inserts installed in a pipe. It can be an interesting alternative to the commonly used Kenics type mixers, due to its simpler geometry and much smaller price. In order to perform numerical simulations a suitable model was created and then covered by generated mesh with an optimized number of elements on basis of the Grid Convergence Index (GCI). Turbulence model and other Fluent-solver settings were also selected. Analyzing the resulting data, a good accuracy between the numerical data and pressure drops calculated from manufacturer’s correlation was observed.
Wartość spadku ciśnienia określa moc niezbędną do przetłoczenia płynu przez mieszalnik i umożliwia dobór odpowiedniego urządzenia pompującego. W pracy określono spadki ciśnienia w mieszalniku statycznym metodami CFD oraz dokonano walidacji opracowanego modelu na podstawie korelacji podawanej przez producenta. Rozpatrywano przepływ jednofazowy w reżimie burzliwym (Re = 1000÷5000). Wykorzystano konstrukcję mieszalnika Koflo®, zawierającą 12 nieruchomych elementów mieszających. Stanowi alternatywę dla powszechnie stosowanych mieszalników typu KENICS, ze względu na prostszą geometrię oraz znacznie niższą cenę. Stworzono odpowiedni model obrazujący geometrię mieszalnika i nałożono siatkę numeryczną posiadającą zoptymalizowaną na podstawie współczynnika GCI (Grid Convergence Index) liczbę elementów. Dokonano także doboru modelu turbulencji i pozostałych ustawień solvera Fluent 15. Analizując uzyskane dane zaobserwowano, że spadki ciśnienia uzyskane na drodze symulacji numerycznych są bliskie wartościom obliczonym w oparciu o wzór producenta.
Źródło:
Inżynieria i Aparatura Chemiczna; 2015, 2; 48--50
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Can deep vein thrombosis be predicted after varicose vein operation in women in rural areas?
Autorzy:
Warot, M.
Synowiec, T.
Wencel-Warot, A.
Daroszewski, P.
Bojar, I.
Micker, M.
Checinski, P.
Powiązania:
https://bibliotekanauki.pl/articles/51742.pdf
Data publikacji:
2014
Wydawca:
Instytut Medycyny Wsi
Opis:
Introduction. Chronic venous disease is a group of symptoms caused by functional and structural defects of the venous vessels. One of the most common aspects of this disease is the occurrence of varicose veins. There are many ways of prevention and treatment of varicose veins, but in Poland the leading one is still surgery. As in every medical procedure there is the possibility of some complications. One of them is deep vein thrombosis (DVT). The diagnosis of DVT can be difficult, especially when access to a specialist is limited, such as in case of rural patients. The aim of the study. The aim of the study was estimation of the influence of LMWH primary prophylaxis on the formation of postoperative DVT, as well as sensitivity and specificity of clinical examination and D-dimer value in diagnosis of postoperative DVT in women. Materials and methods. The study was conducted in a group of 93 women operated on in the Department of General, Vascular Surgery and Angiology at the Karol Marcinkowski University of Medical Sciences in Poznań, Poland. The patients had undergone a varicose vein operation and were randomly divided into two groups: A – 48 women receiving LMWH during two days of the perioperative period, B – 45 women receiving LMWH during seven days of the perioperative period. Results. There was no significant difference in the postoperative DVT complications in both groups. The value of D-dimer > 0.987 mcg/ml and swelling > 1.5 cm of shin (in comparison to the preoperative period) plays a significant role in diagnosis of DVT. Conclusions. The extended primary prophylaxis with LMWH does not affect the amount or quality of thrombotic complications after varicose vein operation. If the DVT occurs, the evaluation of the D – dimer and careful clinical examination can be a useful method for its diagnosis.
Źródło:
Annals of Agricultural and Environmental Medicine; 2014, 21, 3
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody usuwania siarkowodoru i ditlenku węgla z gazu ziemnego i łupkowego
Methods for sweetening natural and shale gas
Autorzy:
Korpyś, M.
Wójcik, J.
Synowiec, P. M.
Powiązania:
https://bibliotekanauki.pl/articles/142029.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
siarkowodór
ditlenek węgla
gaz ziemny
gaz łupkowy
oczyszczanie
hydrogen sulfide
carbon dioxide
natural gas
shale gas
sweetening
Opis:
W artykule przedstawiono przegląd stosowanych metod usuwania kwaśnych zanieczyszczeń gazu ziemnego. Główną uwagę skupiono na sposobach oczyszczania wydobytego gazu z siarkowodoru i ditlenku węgla.
The article presents an overview of the methods used for removing acid impurities from natural and shale gas. In this paper the main attention is focused on how to remove hydrogen sulfide and carbon dioxide from the raw gas.
Źródło:
Chemik; 2014, 68, 3; 211-215
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe rozwiązanie odbioru zawiesiny z krystalizatora fluidalnego
Autorzy:
Wójcik, J.
Synowiec, P. M.
Powiązania:
https://bibliotekanauki.pl/articles/142595.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
krystalizator fluidalny
odbiór zawiesiny
CFD
fluidized-bed crystallizer
discharge
Opis:
New Solution of Crystal Dischrge from FL Crystallizer
Źródło:
Chemik; 2014, 68, 3; 194-197
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyniki badań kurhanu nr V. Babi Dół – Borcz, Powiat Kartuzy
Results of investigation of barrow no V. Babi Dół – Borcz, District Kartuzy
Autorzy:
Mączyńska, M.
Pawlikowski, M.
Jakubczyk, I.
Harasim, P.
Babicz, M.
Sęk, M.
Synowiec, P.
Powiązania:
https://bibliotekanauki.pl/articles/344041.pdf
Data publikacji:
2014
Wydawca:
nakł. Maciej Pawlikowski
Tematy:
kultura wielbarska
Babi Dół – Borcz
Wielbark culture
barrow no V
Opis:
W roku 2013 wykonano badania archeologiczne, geologiczne, mineralogiczno-petrograficzne i geochemiczne kurhanu nr V, znajdującego się na cmentarzysku kultury wielbarskiej w Babim Dole – Borczu, powiat Kartuzy. Badania obejmowały prace eksploracyjne kurhanu i jego najbliższego otoczenia, badania geologiczne profili wytypowanych obiektów, zarówno naturalnych, jak i pochodzenia antropogenicznego, badania mineralogiczno-petrograficzne skał wykorzystanych do konstrukcji kurhanu, badania geochemiczne orsztynów występujących w otoczeniu grobów z otoczenia kurhanu. Badania te miały na celu rekonstrukcje faz budowy kurhanu, prześledzenie zjawisk im towarzyszących, jak też rozpoznanie wybranych zjawisk, które zachodziły w stanowisku po dokonaniu pochówków.
Archaeological as well as geological and mineralogical investigation of Wielbark culture barrow at the site Babiu Dół-Borcz, District Kartuzy were performed. The examination of geological profiles of natural and anthropogenic origin were studied. Moreover examination of products of corrosion of bronze objects, secondary products of alternation of bones, petrography of stone cover was done. Additionally chemical investigation showed sorption of Cu, Zn, P and other by secondary iron concentrations present in local sands. Obtained results suggest preparation of barrow before death of person burred at examined barrow.
Źródło:
Auxiliary Sciences in Archaeology, Preservation of Relics and Environmental Engineering; 2014, 17; 1-29
1689-6742
Pojawia się w:
Auxiliary Sciences in Archaeology, Preservation of Relics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies