Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Suzuki, H." wg kryterium: Autor


Wyświetlanie 1-8 z 8
Tytuł:
Evaluation of reliability of perioral muscle pressure measurements using a newly developed device with a lip piece
Autorzy:
Takahashi, M.
Koide, K.
Suzuki, H.
Satoh, Y.
Iwasaki, S.-I.
Powiązania:
https://bibliotekanauki.pl/articles/306575.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
nacisk
wiarygodność
mięśnie
jama ustna
tongue pressure
upper lip pressure
lower lip pressure
absolute reliability
relative reliabilit
Opis:
Purpose: We examined the reliability of measurements using a newly developed perioral muscle pressure measuring device with a lip piece in healthy adults. Methods: Subjects were 40 healthy men (25.8 years) with normal stomatognathic function. Perioral muscle pressure measuring device with a lip piece was used to measure upper lip, lower lip and tongue pressure, and a balloon-based measurement device was used to measure tongue and cheek pressure. Each measurement was taken twice with a 1-min interval between the two measurements. We determined intra-rater reliability by using the intra-class correlation coefficient as a test of relative reliability. As a test of absolute reliability, Bland–Altman analysis was used to assess systematic bias and the 95% confidence interval of the minimal detectable change was calculated. Additionally, the coefficient of variation was calculated. The Spearman–Brown formula was calculated the number of measurements needed to achieve a confidence coefficient ≥0.9. Each set of measurements was followed by a second set that were taken 1 week later. Results: All measurements showed high values of intra-class correlation coefficient. Upper lip, tongue, and cheek pressure can be determined based on a single measurement, while lower lip pressure requires averaging twice. No systematic bias was observed. The coefficients of variation of measurements were almost the same between the two devices. Conclusion: Measurements were highly reliable regardless of the type of perioral muscles. Our findings suggest that the method described in this study is useful as a quantitative chair side method for examining perioral muscle pressure.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 145-153
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Towards cubic modification of Li7La3Zr2O12 compound by mechanical milling and annealing of powders
Autorzy:
Oleszak, D.
Kurowski, B.
Pikula, T.
Pawlyta, M.
Senna, M.
Suzuki, H.
Powiązania:
https://bibliotekanauki.pl/articles/354963.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
lithium-ion batteries
solid state electrolyte
mechanical milling
XRD
DSC/TG
Opis:
The aim of these studies was to obtain single phase cubic modification of Li7La3Zr2O12 by mechanical milling and annealing of La(OH)3, Li2CO3 and ZrO2 powder mixture. Fritsch P5 planetary ball mill, Rigaku MiniFlex II X-ray diffractometer, Setaram TG-DSC 1500 analyser and FEI Titan 80-300 transmission electron microscope were used for sample preparation and investigations. The applied milling and annealing parameters allowed to obtain the significant contribution of c-Li7La3Zr2O12 in the sample structure, reaching 90%. Thermal measurements revealed more complex reactions requiring further studies.
Źródło:
Archives of Metallurgy and Materials; 2019, 64, 1; 13-16
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of Shallow Dislocations on 4H-SiC Substrate by Etching Method
Autorzy:
Ishikawa, Y.
Yao, Y.
Sato, K.
Sugawara, Y.
Danno, K.
Suzuki, H.
Bessho, T.
Kawai, Y.
Shibata, N.
Powiązania:
https://bibliotekanauki.pl/articles/1492539.pdf
Data publikacji:
2011-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.72.uj
81.65.Cf
68.37.Lp
Opis:
Correlation between dislocation types in epitaxial 4H-SiC and etch pit types on the 4H-SiC wafer surface were investigated by etch pit method and transmission electron microscope. Shallow dislocation on the wafer was found to form round pit without core. The shallow dislocation was estimated half-loop type in wafer and this estimation explains that step-flow growth converts half-loop dislocation into complex dislocation composed by threading dislocation and basal plane dislocation.
Źródło:
Acta Physica Polonica A; 2011, 120, 6A; A-025-A-027
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Introduction of three-dimensional measurement technologies developed and applied in suzuki motor corporation
Autorzy:
Yamage, Y.
Aoki, T.
Hashimoto, T.
Rövid, A.
Shibahara, T.
Akatsuka, S.
Suzuki, H.
Takeshi, M.
Ono, M.
Powiązania:
https://bibliotekanauki.pl/articles/385092.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
image measurement
3D measurement
Direct
Linear Transformation (DLT) methods
Phase-Only Correlation
(POC) function
Opis:
Suzuki Motor Corporation (SMC) recognizes the importance of collaborative projects with Universities and how it contributes to technological development effectively. In spite of the world economical depression, several projects could get started this year leaded by SMC. As a researcher of SMC, Author takes charge of two collaborative projects and introduces these as typical examples of the most successful collaborations. The first is, "3D Measurement System for Crash Tested Car" at Shizuoka University (Japan) and Budapest Tech Polytechnical Institute (Hungary) from 2008; the second is, "High-Accuracy Stereo Vision System Based on Phase-Only Correlation (POC) and Its Application to metal Component Inspection" with Tohoku Univ. (Japan) 2003-2005. By these collaborations, the profound knowledge of universities has a lot of possibility to suits the technical needs of SMC.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 220-223
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electron impact excitation and dissociation of halogen-containing molecules
Autorzy:
Kitajima, M.
Suzuki, R.
Tanaka, H.
Pichl, L.
Cho, H.
Powiązania:
https://bibliotekanauki.pl/articles/148521.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
crossed beam experiment
dissociation
dissociative attachment
differential cross section
electron impact
Opis:
A systematic analysis of the absolute differential cross sections (DCSs) for electron scattering by halogen-containing molecules CF3X (X = H, F, Cl, Br, I) has been performed with impact energy and scattering angle ranging from 1.5 to 100 eV and 15 to 130°, respectively. Three of the results of these experiments are described in the present report. Firstly, a clear difference is demonstrated in the elastic-scattering cross section angular distributions of polar and nonpolar molecules with the substitution of one of the F atoms in CF4 for a H, Cl, Br or I atom. Secondly, vibrational excitation spectra of the unresolved composite modes (mainly CF3 stretching) for CF3X reveal a common broad structure in the region from 7 to 9 eV due to shape resonance. The third result presented is the observation of a low-lying electronic state of CF3Cl, CF3Br, and CF3I. This feature is enhanced at lower incident energies and larger scattering angles. Also discussed are some preliminary results on the formation of negative and neutral fragments from SiF4 and CH4 by electron impact.
Źródło:
Nukleonika; 2003, 48, 2; 89-93
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the breakthrough phenomena during heavy metal elution from a column packed with municipal waste incineration ash
Autorzy:
Zhang, W.
Yang, Y.
Suganuma, H.
Kato, S.
Suzuki, S.
Kojima, T.
Powiązania:
https://bibliotekanauki.pl/articles/206904.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
calcium compounds
dissolution
heavy metals
leaching
particle size
związki wapnia
rozpuszczanie
metale ciężkie
ługowanie
wielkość cząstek
Opis:
At some point during acid leaching column tests of heavy metals from municipal waste incineration ash, sudden and rapid elution of harmful elements was observed which was called the breakthrough (BT) phenomena. The mechanism was elucidated from the results of measurement of elemental and particle size distribution in the column and batch leaching tests as follows. At the first stage of experimental runs, CaCO3 was dissolved in acidic solution and pH profile along the bed is formed. Some of the minor elements of Zn and Al dissolved by acid at the upper part of the column are precipitated at bottom of the column, leading to the reduction of flow rate of the leachate solution. After leachate pH becomes low by the termination of dissolution of Ca, these deposits are dissolved and thus, the flow rate increases. Most of the trace elements behave as such, which causes the increase of harmful element concentrations in the eluate. Some drastic concentration increase of harmful elements in leachate may occur even after the long period of pseudo stable dissolution behavior in the land-fill site.
Źródło:
Environment Protection Engineering; 2018, 44, 3; 63-78
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Increase in cortisol awakening response after two weeks of self-instruction for good sleep
Autorzy:
Nomura, S.
Suguri, K.
Okamoto, Y.
Nomura, T.
Suzuki, K.
Tanaka, H.
Powiązania:
https://bibliotekanauki.pl/articles/333608.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
immunoglobuliny A
spanie
cortisol awakening response
immunoglobulin A
sleep
Opis:
There is growing evidence suggesting that the magnitude of cortisol awaking response (CAR), which is characterized by a profound increase of salivary cortisol secretion after awakening, plausibly reflects the level of a chronic stress, social stress, anxiety, etc. In this study the alternation of CAR at the start and at the end of two weeks session of self-instruction for good sleep was investigated; by which we anticipated that the self-instruction for good sleep would bring-forth a positive affection for the participants, and would result in decline of cortisol awakening response (CAR). Nevertheless, as a result unexpectedly, subjects did not change their sleep and dietary habits along with the instruction, moreover the increased CAR was observed. This result implies that the suggestion of an impractical instruction would solely be taken as a stressful task for participants, even though they know that it is effective to improve their sleep. On the contrary, if one develops an instruction with practicable indication for daily life, it is highly possible to observe a positive effect of the instruction on CAR.
Źródło:
Journal of Medical Informatics & Technologies; 2010, 15; 169-175
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a Pulsed Slow-Positron Beam to Low-Density Polyethylene Film
Autorzy:
Hamada, E.
Oshima, N.
Katoh, K.
Suzuki, T.
Kobayashi, H.
Kondo, K.
Kanazawa, I.
Ito, Y.
Powiązania:
https://bibliotekanauki.pl/articles/2024257.pdf
Data publikacji:
2001
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.70.Bj
Opis:
A pulsing system for a slow-positron beam was applied to study the region near the surface of low-density polyethylene film using positron-annihilation lifetime measurement. The lifetime and intensity of ortho-positronium near the surface were measured as a function of the incident positron energy (1.6-9.1 keV). The size of intermolecular spaces in the surface region (~ 1500 nm) was larger than that in the bulk region. This tendency was especially strong in the region around 200 nm below the surface. On the other hand, the intensity of ortho-positronium decreased at lower incident positron energies, which was attributed to a decrease in the density of the spur electrons and/or an increase in the number of reemitted positrons from the surface.
Źródło:
Acta Physica Polonica A; 2001, 99, 3-4; 373-378
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies