Ballistic Helmet Development Using UHMWPE Fibrous Materials
Opracowanie hełmu balistycznego z wykorzystaniem materiałów włóknistych na bazie UHMWPE
Autorzy:
Fejdyś, M.
Łandwijt, M
Habaj, W
Struszczyk, M. H.
Powiązania:
https://bibliotekanauki.pl/articles/233273.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
ballistic protection
ultra-high molecular weight polyethylene (UHMWPE)
ballistic helmet
hybrid composite
ochrona balistyczna
polietylen o ultra wysokiej masie cząsteczkowej (UHMWPE)
hełm balistyczny
hybrydowy materiał kompozytowy
Opis:
The main aim of the work was to develop a hybrid bullet- and fragment proof helmet protecting the user’s head against small arm ammunition and fragments as well as mechanical impacts. In the construction of the shell, the latest generation of ballistic materials were used, developed on the basis of para-amide fabric coated with a thermosetting resin and high molecular weight polyethylene (UHMWPE). The idea of the study was based on the thesis that the stable connection of two types of fibrous materials differing in their structure, topography as well as in the type of the polymer (para-aramid and polyethylene) will increase the ballistic resistance as well as allow to reduce the mass of the final products. The results of research in the field of the screening of fibrous materials, the process of elaboration as well as the design of bullet- and fragment-proof hybrid helmets are also presented. The ballistic helmets designed were verified within the wide scope of requirements described in PN-V-87001:2011 as well as in the NIJ Standards.
Głównym celem pracy było opracowanie hybrydowego hełmu kulo- i odłamkoodpornego chroniącego głowę użytkownika przed pociskami małokalibrowej broni strzeleckiej oraz odłamkami i uderzeniami mechanicznymi. W konstrukcji czerepu zastosowano surowce balistyczne najnowszej generacji, na bazie których opracowano kompozyt składający się z preimpregnatu tkaniny para-amidowej powleczonej żywicą termoutwardzalną oraz polietylenu o bardzo dużym ciężarze cząsteczkowym (UHMWPE). Ideę badań oparto na tezie, że stabilne połączenie obu typów materiałów włóknistych, różniących się strukturą, topografią, jak również rodzajem polimeru (paraaramid oraz polietylen), zwiększy odporność balistyczną oraz pozwoli na zmniejszenie masy końcowych produktów. W pracy przedstawiono wyniki badań wytypowanych materiałów włóknistych, proces opracowania, jak również projektowania hybrydowego kulo- i odłamkoodpornego hełmu. Zaprojektowane hełmy balistyczne zweryfikowano w szerokim zakresie wymagań opisanych w normie PN-V-87001:2011, a także w normach NIJ Standards.
Źródło:
Fibres & Textiles in Eastern Europe; 2015, 1 (109); 89-97
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Processing Conditions on the Performance of UHMWPE-Fibre Reinforced Polymer Matrix Composites
Wpływ warunków prasowania na właściwości kompozytu na bazie włókien polietylenowych
Autorzy:
Fejdyś, M.
Łandwijt, M.
Kucharska-Jastrząbek, A.
Struszczyk, M. H.
Powiązania:
https://bibliotekanauki.pl/articles/232844.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
ballistic armour
personal protection
ultra-high molecular weight polyethylene
UHMWPE
fibrous polyethylene composites
design process
pancerz balistyczny
środki ochrony indywidualnej
polietylen o ultra-wysokiej masie cząsteczkowej
kompozyty polietylenowe
Opis:
The aim of this study was to analyze the influence of the main pressing parameter, i.e. temperature of a ultra-high molecular weight polyethylene (UHMWPE) fibrous sheet Dyneema ® HB26, on the performance of resultant UHMWPE-fibre reinforced polymer matrix composites intended for the manufacturing of ballistic personal protection. The main goal of this research was to connect the pressing temperature of the initial polyethylene fibrous material and the main performance feature, i.e. the ballistic behaviour of the resultant composites. The polyethylene composites, designed at various temperatures, were subjected to testing of ballistic, mechanical, thermal (DSC) and structural (FTIR) properties, as well as the surface topography by means of scanning electron microscopy (SEM). Attempts were made to determine the correlation between ballistic and mechanical properties of the various types of polyethylene composites designed and their structural and surface properties. Phenomena accompanying the pressing process of the fibrous polyethylene composites at various temperatures are discussed along with attempts to estimate the mechanisms of changes. This research allowed for the determination of optimal pressing conditions for fibrous polyethylene material to obtain a composite with optimal features for ballistic and personal protection application.
Celem pracy była analiza wpływu temperatury prasowania nietkanego wyrobu polietylenowego (UHMWPE) Dyneema® HB26 na właściwości wytworzonego kompozytu przeznaczonego do balistycznych ochron osobistych. Głównym celem było określenie współzależności miedzy temperaturą prasowania a odpornością balistyczną otrzymanych kompozytów. Wytworzone w różnych temperaturach kompozyty poddano badaniom odporności balistycznej oraz właściwości: mechanicznych, termicznych i strukturalnych, i także badaniom morfologii powierzchni. Podjęto próbę określenia zależności pomiędzy odpornością balistyczną, a właściwościami mechanicznymi zaprojektowanych kompozytów polietylenowych, jak również ich właściwościami strukturalnymi i powierzchniowymi. Przedyskutowano zjawiska towarzyszące prasowaniu kompozytów polietylenowych w różnych temperaturach, a nastepniepodjęto próbę określenia mechanizmów tych procesów oraz oszacowania zmian zachodzących w kompozytach. Badania pozwoliły na określenie optymalnej wartości temperatury prasowania tego wyrobu.
Źródło:
Fibres & Textiles in Eastern Europe; 2016, 4 (118); 112-120
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspects of Chemical Characterisation of Leachables Profile from Ultra-Light Knitting Textiles for Uses as Medical Implants in Urogynaecology and General Surgery
Aspekty charakterystyki chemicznej substancji wymywalnych z ultralekkich dzianin o potencjalnym zastosowaniu jako implantowalne wyroby medyczne stosowane w urologinekologii i chirurgii ogólnej
Autorzy:
Jóźwicka, J.
Gzyra-Jagieła, K
Struszczyk, M. H.
Gutowska, A.
Ciechańska, D.
Krucińska, I
Powiązania:
https://bibliotekanauki.pl/articles/232383.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
ultra-light textile implants for urogynaecology
evaluation of chemical leachable profile
physical-chemical parameters
substancje wymywalne z ultralekkich dzianin
wyroby medyczne
implanty w urologii
Opis:
Ultra-light textiles (knitwear) designed as implantable medical devices for potential uses in urogynaecology (treatment procedures in women incontinence and vagina reconstructions) and general surgery (hernia treatments) are a response to the increasing demand for advanced medical devices in medicine. Chemical profile characterisation of leachable substances is an important factor in the use of the materials influencing their biocompatibility. The implant is made of undesired chemical substances in the main raw-material, and penetration into the tissue may cause local and/or systemic inflammation in the patient’s body. The characterisation and analysis of such substances is therefore essential to secure the safe use of implants. Most important is the characterisation of the matter that is extractable from the designed medical devices. To serve these purpose, ultra-light textile implants designed for potential use in urogynaecology and general surgery were examined concerning the chemical analysis of the undesired substance contained in the main material which constitutes the base of the implant. It was a goal of the work to set optimal parameters for the examination of chemical characterisation of the leachable implant’s material, bearing in mind their safe clinical use. Analysis of the chemical leachable profile was made in accordance with directives of standard PN-EN ISO 10993-18:2008 and some Polish and European testing procedures.
Artykuł przedstawia innowacyjne ultra-lekkie implanty włókiennicze w postaci dzianiny z przeznaczeniem na implanty do potencjalnego zastosowania w urologinekologii i chirurgii ogólnej (procedury zaopatrywania przepuklin nietrzymania moczu u kobiet i plastyki pochwy). Badano własności?? charakterystyki substancji wymywalnych z projektowanych implantów. Ultralekkie dzianiny poddano ocenie czystości chemicznej pod kątem wpływu ewentualnych substancji wymywalnych na ich bezpieczeństwo kliniczne. Wyznaczono optymalne parametry badań czystości chemicznej implantowalnych wyrobów medycznych. Oceny czystości chemicznej wyselekcjonowanych dzianin dokonano w oparciu o metody badawcze opracowane na podstawie wytycznych normy PN-EN ISO 10993-18:2008: „Biologiczna ocena wyrobów medycznych – Część 18: Charakterystyka chemiczna materiałów” (ISO 10993-18:2009) oraz opracowanych procedur badawczych na bazie normatywów polskich i europejskich.
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 6B (96); 128-134
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Safety and Labelling Requirements for Textile Products - Design and Use Aspects
Wymagania bezpieczeństwa i znakowania produktów włókienniczych – aspekty projektowe oraz użytkowe
Autorzy:
Kosińska, B
Czerwiński, K.
Struszczyk, M. H.
Powiązania:
https://bibliotekanauki.pl/articles/233427.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
textile product
safety
labelling
design requirements
wyrób włókienniczy
bezpieczeństwo
oznakowanie
wymagania projektowe
Opis:
This article presents an analysis of changes that have occurred in recent times in legislation relating to the safety and labelling of textile products in connection with the coming into force of harmonised Community regulations relating to products containing textile fibres intended for sale on the EU market, with a presentation of a range of issues which may be the subject of future Community legislation. The article discusses, mainly in terms of design, current safety requirements for textile products and also provides guidance for the design of new textile solutions in relation to the assessment of potential adverse effects on the human body.
Artykuł przedstawia analizę zmian jakie zaistniały w ostatnim czasie w uregulowaniach prawnych związanych z bezpieczeństwem i znakowaniem produktów tekstylnych w związku z wejściem w życie zharmonizowanych przepisów wspólnotowych odnoszących się do wyrobów zawierających włókna tekstylne, a przewidzianych do udostępnienia na rynku Unii Europejskiej. W pracy zaprezentowano zakres zagadnień, które mogą być przedmiotem przyszłych wspólnotowych przepisów. W artykule omówiono, w aspekcie głownie projektowym obecnie funkcjonujące wymagania związane z bezpieczeństwem wyrobów włókienniczych oraz wytyczne w zakresie projektowania nowych rozwiązań włókienniczych także w odniesieniu do oceny potencjalnych i niekorzystnych efektów oddziaływań na organizm człowieka
Źródło:
Fibres & Textiles in Eastern Europe; 2014, 2 (104); 19-24
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Modified Knitted Hernia Implants after Implantation: I. Biological Effect on the Structural and Usable Properties
Poimplantacyjna ocena modyfikowanych dzianych implantów do zaopatrywania przepuklin: I. Wpływ implantacji na właściwości użytkowe oraz strukturalne
Autorzy:
Kostanek, K.
Struszczyk, M. H.
Chrzanowski, M.
Żywicka, B.
Paluch, D.
Szadkowski, M.
Gutowska, A.
Krucińska, I.
Powiązania:
https://bibliotekanauki.pl/articles/233588.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
knitted hernia implants
low temperature plasma treatment
biological evaluation
dziane implanty leczenie przepukliny
niska temperatura plazmy
ocena biologicznych
Opis:
The purpose of this article is to discuss the solution of the main clinical adverse events occurring in less invasive reconstruction of hernia. The study attempted to design the knitted implants, contributing to reduce the risk of adhesion to the viscera. Specially designed knitting structure of the hernia implant allowed to introduce the one-side enhancement of the surface in the form of loops stitched-out of the surface accelerated the connective tissue in-growth. The opposite side was modified the treatment in low-temperature plasma of low molecular weight fluorogenic compound resulted in the deposition of fluoropolymer nano-layer. The effect of the modification on the adhesion of implant to viscera was studied in vivo. Additionally, the influence of the implantation time on the structural properties, the connective tissue covering implants single monofilaments as well as the stability of the fluoropolymer layer formed during the implantation were detailed investigated.
Artykuł omawia techniczną próbę rozwiązania głównych problemów występujących w rekonstrukcjach przepukliny, wykonywanych techniką małoinwazyjną. W badaniach podjęto próbę zaprojektowania dzianego implantu, którego właściwości wpływają na zmniejszenie ryzyka jego adhezji do narządów wewnętrznych. Specjalnie opracowana struktura dziewiarska implantu do zaopatrywania przepuklin pozwoliła na uzyskanie jednostronnego rozwinięcia powierzchni w postaci wystających z powierzchni pętelek wspomagających proces wgajania tkanką łączną. Druga powierzchnia implantu została poddana modyfikacji w środowisku plazmy niskotemperaturowej niskocząsteczkowego związku fluoroorganicznego prowadząc do uformowania nanowarstwy fluoropolimeru. Umożliwiło to obniżenie ryzyka adhezji implantu dzianego do narządów wewnętrznych, co potwierdzono w badaniach in vivo. Prowadzono także ocenę wpływu czasu implantacji na właściwości strukturalne implantu, stopień pokrycia tkanką łączną pojedynczych monofilamentów oraz stabilność uformowanej nanowarstwy fluoropolimeru.
Źródło:
Fibres & Textiles in Eastern Europe; 2013, 6 (102); 79-83
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological Dressings Based on Natural Polymers
Opatrunki biologiczne oparte na polimerach naturalnych
Autorzy:
Kucharska, M.
Brzoza-Malczewska, K.
Wiśniewska-Wrona, M.
Pałys, B.
Struszczyk, M. H.
Cichecka, M.
Wilbik-Hałgas, B.
Karuga-Kuźniewska, E.
Paluch, D.
Rybak, Z.
Powiązania:
https://bibliotekanauki.pl/articles/232095.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
wound dressing
polysaccharides
microfibrids
nanofibrids
biocompatibility
opatrunek
polisacharydy
proszek fibrydowy
biozgodność
Opis:
The article presents a method for producing a IV generation hemostatic dressing in the form of powder consisted of fibrous, which ensures a high level of security in application. The dressing material was developed on the basis of natural polymers of the polysaccharide group such as chitosan and calcium sodium alginate in the form of micro- and nanofibrids. The dressing structure, utility properties and biocompatibility (cytotoxicity, irritation and sensitization) were studied.
W artykule przedstawiono metodę wytwarzania hemostatycznego opatrunku IV generacji, który gwarantuje wysoki stopień bezpieczeństwa przy aplikacji. Opatrunek posiada formę proszku fibrydowego. Do opracowania materiału opatrunkowego wykorzystane zostały polimery naturalne z grupy polisacharydów takie jak chitozan i alginian sodowo-wapniowy. Opatrunek został poddany badaniom strukturalnym, właściwościom użytkowym oraz ocenie biozgodności (cytotoksyczność, właściwości drażniące i uczulające).
Źródło:
Fibres & Textiles in Eastern Europe; 2016, 6 (120); 170-174
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototypes of Primary Wound Dressing of Fibrous and Quasi-Fibrous Structure in Terms of Safety of Their Usage
Prototypy opatrunków o strukturze włóknistej i quasi-włóknistej w zakresie bezpieczeństwa ich użytkowania
Autorzy:
Kucharska, M.
Struszczyk, M. H.
Cichecka, M
Brzoza-Malczewska, K.
Wiśniewska-Wrona, M
Powiązania:
https://bibliotekanauki.pl/articles/233815.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
wound dressings
fibrous structure
biopolymers
preclinical studies
risk assessment
parametry bezpieczeństwa
materiały opatrunkowe
wyroby medyczne
Opis:
The subject of this paper is the evaluation of the critical usability parameters and the parameters characterising the safety of selected prototypes of dressing materials on featuring fibrous, quasi-fibre and hybrid structures, developed at the Institute of Biopolymers and Chemical Fibres (IBWCh). Primary sterile dressing materials were evaluated for usability, which determines the user’s safety and physiological comfort according to a series of PN-EN 13726 standards, harmonised with the EU Directive on medical devices, before and after the accelerated ageing process. The scope of the research was developed based on identifying potential threats arising from the expected clinical application of the medical devices being designed. It allowed for the determination of the impact of selected physical and mechanical parameters, needed from a utility point of view, on the properties of the final medical devices, and the elaboration of the documentation of risk analysis, according to the guide described in Standard PN-EN ISO 14971:2011.
Przedmiotem artykułu jest ocena krytycznych parametrów użytkowych i parametrów charakteryzujących bezpieczeństwo wybranych prototypów materiałów opatrunkowych o strukturach włóknistych, quasi-włóknistych i hybrydowych, opracowanych w Instytucie Biopolimerów i Włókien Chemicznych (IBWCh). Sterylne specjalistyczne materiały opatrunkowe zostały poddane ocenie właściwości użytkowych charakteryzujących bezpieczeństwo i komfort fizjologiczny użytkownika zgodnie z serią norm PN-EN 13726 zharmonizowanych z Dyrektywą UE o wyrobach medycznych przed i po procesie symulowanego starzenia. Przeprowadzone badania, których zakres został opracowany dzięki identyfikacji potencjalnych zagrożeń wynikających z przewidywanego klinicznego zastosowania projektowanych wyrobów medycznych, pozwoliły na ustalenie wpływu wybranych parametrów fizyko-mechanicznych, niezbędnych z użytkowego punktu widzenia, na właściwości gotowych wyrobów medycznych oraz przygotowanie dokumentacji analizy ryzyka zgodnie z wymogami normy PN-EN ISO 14971:2011.
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 6B (96); 142-148
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural Changes in Plasma Assisted Chemical Vapour Deposition-Modified Ultra-high Molecular Weight Polyethylene, Ballistic Textiles During Accelerated Ageing
Zmiany strukturalne zmodyfikowanego techniką PACVD polietylenu o ultra wysokiej masie cząsteczkowej; tekstylia balistyczne podczas przyśpieszonego starzenia
Autorzy:
Miklas, M.
Struszczyk, M. H.
Urbaniak–Domagała, W.
Puszkarz, A. K.
Wilbik-Hałgas, B.
Cichecka, M.
Sztajnowski, S.
Puchalski, M.
Krucińska, I.
Powiązania:
https://bibliotekanauki.pl/articles/232025.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
chemical modification
surface modification
PACVD
composites
material properties
material strength
soft UHMWPE fibrous composite
modyfikacja chemiczna
modyfikacja powierzchni
kompozyty
właściwości materiału
wytrzymałość materiału
Opis:
The aim of this study was to compare the susceptibility of the plasma assisted chemical vapour deposition (PACVD) - surface modification of ultra-high molecular weight polyethylene (UHMWPE) fibrous composite to conditions of use and storing simulated by accelerated aging. Aspects of heksametylodisiloksan (HMDSO) implementation as donor for deposited during PACVD modification nanolayer as well as the selection of a new textile carrier were discussed. For the identification of potential changes in PACVD - modified UHMWPE, with, the Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) and Scanning Electron Microscopy with X-ray microanalysis (SEM/EDS) techniques were applied. The PACVD surface modification of UHMWPE showed insignificant changes in structural properties after using temperature or simultaneously temperature and humidity ageing factors. The process of accelerated ageing confirmed the time-stable presence of silicon contained in the polymer layer in both cases: when temperature or simultaneously temperature and humidity were used as accelerated aging factors. No significant changes in the morphology nor topography of the fibrous materials tested were found, subjected or not to the process of PACVD - modification using the HMDSO as a substrate for the surface-deposited polymer.
Weryfikację funkcjonalności modyfikacji powierzchni z wykorzystaniem technologii chemicznego osadzania z fazy gazowej ze wspomaganiem plazmowym (PACVD) polietylenu o ultra wysokiej masie cząsteczkowej (UHMWPE) przeprowadzono po procesie przyśpieszonego starzenia z wykorzystaniem temperatury lub równocześnie temperatury i wilgotności jako czynników przyspieszających starzenie. Modyfikację przeprowadzono przez naniesienie polimeru wytworzonego na bazie heksametylodisiloksanu (HMDSO). Celem prowadzonych badań było porównanie podatności zmodyfikowanych techniką PACVD włókien UHMWPE na symulowane warunki użytkowania i przechowywania w czasie przyśpieszonego starzenia. Do zidentyfikowania potencjalnych zmian w powierzchni zmodyfikowanych techniką PACVD włókien UHMWPE zastosowano techniki ATR-FTIR oraz SEM/EDS. Proces modyfikacji powierzchni UHMWPE z wykorzystaniem procesu PACVD wykazał nieznaczne zmiany właściwości strukturalnych po procesie przyspieszonego starzenia z wykorzystaniem temperatury lub równocześnie temperatury i wilgotności jako czynników przyspieszających starzenie. Proces przyspieszonego starzenia wykazał stabilność warstwy polimerowej w obu przypadkach: temperatury lub temperatury i wilgotności jako czynników użytych w procesie przyśpieszonego starzenia.
Źródło:
Fibres & Textiles in Eastern Europe; 2016, 5 (119); 63-67
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Textile Multilayered Systems with Magnetorheological Fluids for Potential Application in Multi-Threat Protections. Preliminary Stab - Resistance Studies
Materiały kompozytowe z cieczami magnetoreologicznymi do potencjalnego zastosowania w ochronie przed zróżnicowanymi zagrożeniami – wstępne badania odporności na przekłucie
Autorzy:
Olszewska, K.
Polak, J.
Zielińska, D.
Struszczyk, M. H.
Kucińska, I.
Wierzbicki, Ł.
Kozłowska, J.
Leonowicz, M.
Wiśniewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/233188.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
ballistic insert
magnetorheological fluid (MRF)
MRF/fabric composite
impact test
stab resistance
wkładka balistyczna
elastyczne pancerze
ciecz magnetoreologiczna (MRF)
MRF / tkanina kompozytowa
test na uderzenia
odporność na przekłucie
Opis:
The article presents the results of preliminary work carried out for flexible body armour systems designs which contained three types of magnetorheological fluid (MRFs). The stab resistance of the multilayered material systems with magnetorheological fluids were investigated. Tests were carried out on a newly built rig at the Faculty of Materials Science and Engineering, Warsaw University of Technology. Three different configurations of flexible body armour were made. It was found that samples of the multilayered material system containing MRF had lower depth of deformation by about 30% than the reference samples. The combination of MRFs with para-aramid woven fabrics in several usable forms and/or sheets of ultra-high molecular weight polyethylene fibres gives possibilities for obtaining new types of multi-layered systems protecting effectively against various kind of threats.
W niniejszym artykule zaprezentowano wyniki wstępnych prac przeprowadzonych dla elastycznych pancerzy, zawierających 3 typy cieczy magnetoreologicznej. Zbadano odporności na przekłucie układów materiałowych z cieczami MR. Testy przeprowadzono na nowo powstałym stanowisku na Wydziale Inżynierii Materiałowej, Politechniki Warszawskiej. Wykonano konstrukcje elastycznych pancerzy o trzech różnych konstrukcjach. Na podstawie wstępnych wyników stwierdzono, iż próbki zawierające ciecz magnetoreologiczną miały mniejszą głębokość deformacji o ok. 30 % niż odpowiadające im wzorce. Połączenie cieczy MR z tkaninami z włókien para-aramidowych i/lub z nietkanymi wyrobami z włókien polietylenowych stwarza możliwość uzyskania nowego typu kompozytów skutecznie chroniących przed różnego rodzaju zagrożeniami.
Źródło:
Fibres & Textiles in Eastern Europe; 2013, 5 (101); 112-116
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal stability of the elastomeric anti-trauma pad
Autorzy:
Olszewska, K.
Zielinska, D.
Struszczyk, M. H.
Wierzbicki, Ł.
Leonowicz, M. K.
Powiązania:
https://bibliotekanauki.pl/articles/779441.pdf
Data publikacji:
2017
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
anti-trauma pad
shear thickening fluid
accelerated aging
Opis:
The elastomeric anti-trauma pad (EA-TP) based on shear thickening fluid (STF) has been developed. Dynamic oscillatory shear experiment was conducted at constant strain amplitude of 5%. STF composed of 25% of volume fraction of 7 nm Fumed Silica, dispersed in polypropylene glycol with molar mass 400 gmol−1  shows elastic properties in entire investigated range of the frequency. Ballistic tests of EA-TP with 7.62 mm × 39 mm PS bullets were performed according to the PN-V-87000:2011 standard. The studies revealed about 60% reduction of the average backface signature depth (BSD) for the EA-TP, when compared to the nowadays commonly used soft insert. The ATR-FTIR analysis confirmed slight impact of the elevated temperature and air (oxygen) on the chemical degradation of the EA-TP surface. The UV-VIS spectroscopy has allowed to notice colour deviation of the aged samples towards green and yellow, as well as lack of dye resistance to accelerated aging process. Thermographic analysis has shown no visible changes of the EA-TP surface and sub-surface during accelerated aging process. The aforementioned small changes on the surface of EA-TP did not affect the ballistic properties of composite armour. EA-TP insert maintains ballistic properties after accelerated aging process which was simulating the period of 6 years according to ASTM F1980 – 07:2002 standard.
Źródło:
Polish Journal of Chemical Technology; 2017, 19, 2; 93-100
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bullet - proof vests with the ballistic inserts based on the fibrous composites
Autorzy:
Polak, J.
Kucinska, I.
Grabowska, G.
Błaszczyk, J.
Ledwon, E.
Romek, R.
Struszczyk, M.H.
Powiązania:
https://bibliotekanauki.pl/articles/238088.pdf
Data publikacji:
2009
Wydawca:
Instytut Technologii Bezpieczeństwa Moratex
Tematy:
kompozyty włókniste
kamizelka kuloodporna
fibrous composites
bullet-proof vest
Opis:
Several design solutions of bullet-proof vests featuring improved ballistic resistance within area of hard inserts based on fibrous composites, recently developed by the "MORATEX" Institute were presented. They are mainly dedicated for the officers of services subordinated to the Ministry of Interior and Administration. They consider latest world-wide trends of developing, regarding started works within the development PO IG (Innovative Economy National Cohesion Strategy) project No.01.03.01-10-005/08 "Modern ballistic body armours and covers for transportation means as well as for buildings made on a basis of textile composites". The composite insert for the vests and some vest designs are one of product groups being developed within the project. Their modern designs were presented and discussed, along with the results of metrological tests of physical and mechanical parameters of materials as well as the ballistic tests results. The initial presumptions for developing Polish inserts based on the fibrous composites were stated.
Źródło:
Techniczne Wyroby Włókiennicze; 2009, R. 17, nr 2/3, 2/3; 95-106
1230-7491
Pojawia się w:
Techniczne Wyroby Włókiennicze
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accelerated Ageing of the Implantable, Ultra-Light, Knitted Medical Devices Modified by Low-Temperature Plasma Treatment – Part 1. Effects on the Physical Behaviour
Badania przyspieszonego starzenia implantowalnych, ultra lekkich, dzianych wyrobów medycznych modyfikowanych powierzchniowo plazmą nisko temperaturową – Część 1. Wpływ na właściwości fizyczne
Autorzy:
Struszczyk, M. H.
Gutowska, A.
Pałys, B
Cichecka, M
Kostanek, K
Wilbik-Hałgas, B.
Kowalski, K.
Kopias, K.
Krucińska, I.
Powiązania:
https://bibliotekanauki.pl/articles/233165.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
implants
ultra-light medical devices
knitted structures modification
low-temperature plasma
physical behaviour
starzenie implantów
wyroby medyczne
właściwości fizyczne
dziane wyroby medyczne
Opis:
The aim of the research was to validate the effects of accelerated ageing on the physical properties of newly-designed ultra-light three dimensional (3-D) knitted implants undergoing one-sided modification by low-temperature plasma treatment using low molecular weight fluoroorganic donors. The influence of storing the knitted medical devices for 1 or 2 years at accelerated conditions was studied taking into account their selected physical properties in relation to key usable features. The presented study is a continuation of previous research for the elaboration of a new-idea of three-dimensional implants applied in hernioplasty (general surgery), vaginoplasty and urinary incontinence treatment (urologynaecology).
Celem prowadzonych badań była walidacja wpływu przyspieszonego starzenia na fizyczne właściwości nowo opracowanej konstrukcji ultralekkich, trójwymiarowych dzianych implantów poddanych jednostronnej modyfikacji nisko temperaturową plazmą w obecności niskocząsteczkowego związku fluoroorganicznego. Ocenie poddano wybrane kluczowe z punktu widzenia aspektów użytkowych, właściwości fizyczne zaprojektowanych dzianych wyrobów medycznych poddanych procesowi przyspieszonego starzenia. Prezentowana praca stanowi kontynuację wcześniejszych badań dotyczących opracowania trójwymiarowych implantów stosowanych w rekonstrukcji przepuklin (chirurgia ogólna), plastyce pochwy lub do chirurgicznego leczenia nietrzymania moczu (urologinekologia).
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 6B (96); 121-127
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Prospect of Textile Technologies for Medical Devices
Ocena perspektyw technologii włókienniczych wyrobów medycznych
Autorzy:
Struszczyk, M. H.
Olejnik, M.
Powiązania:
https://bibliotekanauki.pl/articles/234260.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
wyroby medyczne
technologie włókiennicze
ubieranie
implanty
medical devices
textile technologies
foresight
dressing
implants
Opis:
This article includes the assessment of fibrous medical devices as well as borderline products from the point of view of expenditures necessary for the realisation of research and implementation in industrial and clinical practices, the range of practice implementation benefits as well as potential barriers restricting studies and implementation. The scale of investment necessary for the realisation of research and implementation in industrial practices in relation to the benefits of implementing them in practice as well as the limitations that restrict the research and implementation of selected fibrous technologies for medical devices are discussed in detail.
W artykule omówiono technologie włókienniczych wyrobów medycznych biorąc pod uwagę poziom koniecznych nakładów na realizację badań oraz wdrożenie rezultatów tych badań, skalę korzyści wdrożenia do praktyki oraz ewentualne, zidentyfikowane zgodnie z obecnym stanem wiedzy, bariery ograniczające procesy badawcze oraz komercjalizacyjne. Oszacowano także obecny stan zaawansowania badań nad włókienniczymi wyrobami medycznymi w kraju i za granicą wraz z próbą oceny stopnia ich gotowości do wdrożenia do praktyki i przewidywanego okresu komercjalizacji.
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 6A (95); 28-36
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomechanical Studies of Novel Hernia Meshes with Enhanced Surface Behaviour
Badania biomechaniczne nowych konstrukcji implantów przepuklinowych o rozwiniętej powierzchni
Autorzy:
Struszczyk, M. H.
Komisarczyk, A.
Krucińska, I.
Gutowska, A.
Pałys, B
Ciechańska, D.
Powiązania:
https://bibliotekanauki.pl/articles/232576.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
hernia meshes
knitted textile implants
surface modification
mechanical resistance
siatka przepuklinowa
dziane implanty tekstylne
modyfikacja powierzchni
odporność mechaniczna
Opis:
Research on hernia implants, especially less-invasive implantation techniques, is an important focus of study around the world. Practitioners require that these elaborate structures, which are primarily designed using textile technology, possess biomimetic behaviour to significantly reduce post-implantation complications. Novel textile hernia implants are designed with surface modifications that prevent prosthesis migration after implantation. The specialised structural design and enhanced prosthesis surface with stitched loops enables increased surface contact with the fascia, which improves the integration of connective tissue with the prosthesis without overgrowth (thick scar formation). The main intra-operative clinical benefit of the novel implant is its potential utility in suture-less techniques. The aim of this study was to compare novel hernia implant designs to clinically proven, commercially available knitted hernia meshes in vitro. TEMA MOTION 3.5 software was used to analyse motion and estimate the tendency of the non-fixed implants to remain in a stable position at the sublay in a simulated hydrodynamic model of the abdominal wall hernia system. The mechanical resistance of the implant against simulated maximal intra-abdominal pressure, the height of the simulated abdominal wall in the reconstruction region and the curvature of the reconstructions were determined and compared with results obtained with commercial hernia meshes of low surface mass that differ in structure, stiffness and thickness.
Badania nad konstrukcją implantów przepuklinowych, szczególnie stosowanych w zabiegach małoinwazyjnych, stanowią ważny obszar badawczy na całym świecie. Chirurdzy wymagają, aby struktury zaprojektowane przy zastosowaniu technologii włókienniczych charakteryzowały się biomimetyzmem, co w znaczący sposób obniża ryzyko powikłań po implantacji. Nowoczesne, włókiennicze implanty przepuklinowe zostały zaprojektowane w oparciu o modyfikację ich powierzchni, która przeciwdziałała migracji protezy po implantacji. Wysoce specjalistyczna struktura oraz rozwiniecie powierzchni implantu poprzez pętle wystające z jego powierzchni zwiększa powierzchnię kontaktu z powięzią, poprawiając integrację tkanki łącznej z protezą bez nadmiarowego przerostu tkanką łączną (formowanie grubej blizny pooperacyjnej). Główną zaletą nowych implantów dzianych jest ich potencjalne zastosowanie kliniczne w technikach wszczepiania bez szwu tzw. „suture-less”. Celem badań było porównanie nowych dzianych implantów przepuklinowych z klinicznie stosowanymi w warunkach in vitro (symulacja implantacji). Do analizy dynamicznej zachowania implantów pod wpływem stosowanej siły symulującej ciśnienie wewnątrzbrzuszne zastosowano oprogramowanie TEMA MOTION 3.5. Oceniono stabilność implantów przepuklinowych niemocowanych szwami w hydrodynamicznym modelu przepukliny brzusznej.
Źródło:
Fibres & Textiles in Eastern Europe; 2014, 1 (103); 129-134
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Accelerated Ageing on Ballistic Textiles Modified By Plasma-Assisted Chemical Vapour Deposition (PACVD)
Wpływ przyspieszonego starzenia na tekstylia balistyczne zmodyfikowane techniką plazmy niskotemperaturowej
Autorzy:
Struszczyk, M. H.
Puszkarz, A. K.
Miklas, M.
Wilbik-Hałgas, B.
Cichecka, M.
Urbaniak–Domagała, W.
Krucińska, I.
Powiązania:
https://bibliotekanauki.pl/articles/232633.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
UHMWPE fibrous composites
low temperature plasma assisted deposition
accelerated aging
UHMWPE
kompozyty włókniste
plazma niskotemperaturowa
przyspieszone starzenie
Opis:
The functionalisation of textile products and materials using the low temperature plasma technique is increasingly used in industrial practice, mainly because of the many benefits, often unattainable with the use of other techniques. The study focused on the modification of the composite textile materials - sheets of Ultra High Molecular Weight Polyethylene (UHMWPE) fibres (Dyneema® SB51) by applying the surface deposition of silicone-like polymer in an environment of low temperature plasma. The aim of this study was to evaluate changes in the mechanical and physical properties of modified ballistic textiles under simulated storage conditions in accelerated time. Based on experiences in planning the research on accelerated aging, a test programme was developed for the assessment of changes during the aging process in ballistic fibrous materials under various environmental conditions. The process of low temperature plasma modification affected the mechanical properties of the ballistic composite textile materials during the accelerated ageing using temperature or temperature and humidity. The effect of the modification varied with the mechanical properties investigated.
Funkcjonalizacja tekstylnych produktów i materiałów, przy zastosowaniu techniki plazmy niskotemperaturowej, jest coraz częściej stosowana w praktyce przemysłowej, głownie ze względu na wiele korzyści, często nieosiągalnych dla innych technik modyfikacji. W prezentowanych badaniach skupiono się na modyfikacji kompozytowych materiałów tekstylnych wykonanych z włókien polietylenowych o znaczącej masie cząsteczkowej (Dyneema® SB51) poprzez depozycję powierzchniową polimerów silanowych w środowisku plazmy niskotemperaturowej. Celem pracy była ocena zmian w właściwościach mechanicznych i fizycznych zmodyfikowanych tekstyliów balistycznych pod wpływem symulowanych warunków przechowywania w badaniach przyspieszonego starzenia. Program badań został opracowany na podstawie doświadczeń w planowaniu badań przyspieszonego starzenia, celem określenia zmian w włókienniczym materiale balistycznym zachodzących w czasie starzenia, w różnych warunkach środowiskowych. Proces modyfikacji plazmą niskotemperaturową wywoływał zmiany w właściwościach mechanicznych kompozytowych materiałach balistycznych podczas przyspieszonego starzenia przy zastosowaniu jako czynnika starzeniowego: temperatury lub temperatury i wilgotności. Obserwowane tendencje zmian w właściwościach różniły się w zależności od badanej cechy materiału.
Źródło:
Fibres & Textiles in Eastern Europe; 2016, 1 (115); 83-88
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies