Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Song, Weimin" wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Preliminary study to explore gene-$\text{PM}_\text{2.5}$ interactive effects on respiratory system in traffic policemen
Autorzy:
Zhao, Jinzhuo
Bo, Liang
Gong, Changyi
Cheng, Peng
Kan, Haidong
Xie, Yuquan
Song, Weimin
Powiązania:
https://bibliotekanauki.pl/articles/2177102.pdf
Data publikacji:
2015-08-07
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
inflammation
Fine Particles
traffic workers
respiratory system
single nucleotide polymorphism
SNP
Opis:
Objectives Traffic-related particulate matter (PM) is one of the major sources of air pollution in metropolitan areas. This study is to observe the interactive effects of gene and fine particles (particles smaller than 2.5 μm – $\text{PM}_\text{2.5}$) on the respiratory system and explore the mechanisms linking $\text{PM}_\text{2.5}$ and pulmonary injury. Material and Methods The participants include 110 traffic policemen and 101 common populations in Shanghai, China. Continuous 24 h individual-level $\text{PM}_\text{2.5}$ is detected and the pulmonary function, high-sensitivity C-reactive protein (hs-CRP), Clara cell protein 16 (CC16) and the polymorphism in CXCL3, NME7 and C5 genes are determined. The multiple linear regression method is used to analyze the association between $\text{PM}_\text{2.5}$ and health effects. Meanwhile, the interactive effects of gene and $\text{PM}_\text{2.5}$ on lung function are analyzed. Results The individual $\text{PM}_\text{2.5}$ exposure for traffic policemen was higher than that in the common population whereas the forced expiratory volume in 1 s (FEV₁), the ratio of FEV₁ to forced vital capacity (FEV₁/FVC) and lymphocytes are lower. In contrast, the hs-CRP level is higher. In the adjusted analysis, $\text{PM}_\text{2.5}$ exposure was associated with the decrease in lymphocytes and the increase in hs-CRP. The allele frequencies for NME7 and C5 have significant differences between FEV₁/FVC ≤ 70% and FEV₁/FVC > 70% participants. The results didn’t find the interaction effects of gene and $\text{PM}_\text{2.5}$ on FEV₁/FVC in all the 3 genes. Conclusions The results indicated that traffic exposure to high levels of $\text{PM}_\text{2.5}$ was associated with systemic inflammatory response and respiratory injury. Traffic policemen represent a high risk group suffering from the respiratory injury.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2015, 28, 6; 971-983
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Theoretical analysis of temperature rising for chilled water in the long distance transport pipelines in coal mine
Analiza teoretyczna wzrostu temperatur ochłodzonej wody w transporcie rurociągami na duże odległości w kopalniach węgla
Autorzy:
Yudong, Qi
Weimin, Cheng
Song, Xin
Powiązania:
https://bibliotekanauki.pl/articles/218958.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wymiana ciepła
ciepło tarcia
model
analiza teoretyczna
heat transfer
friction heat
theoretical analysis
Opis:
In order to provide sufficient cooling capacity for working and heading faces of the coal mine, chilled water is often transported a long distance along pipelines in deep mine, which inevitably results in its temperature rising owing to heat transfer through pipe wall and the friction heat for flow resistance. Through theoretical models for temperature increasing of the chilled water were built. It is pointed out that the temperature rising of the chilled water should be considered as a result of the synergy effects of the heat transfer and the friction heat, but theoretical analysis shows that within engineering permitting error range, the temperature increasing can be regarded as the sum caused by heat transfer and fraction heat respectively, and the calculation is simplified. The calculation analysis of the above two methods was made by taking two type of pipe whose diameters are De273 × 7 mm and De377 × 10 mm, with 15 km length in coal mine as an example, which shows that the error between the two methods is not over 0.04°C within the allowable error range. Aims at the commonly used chilled water diameter pipe, it is proposed that if the specific frictional head loss is limited between 100 Pa/m and 400 Pa/m, the proportion of the frictional temperature rising is about 24%~81% of the total, and it will increase with high flow velocity and the thin of the pipe. As a result, the friction temperature rising must not be ignored and should be paid enough attention in calculation of the chilled water temperature rising along pipe.
W celu zapewnienia odpowiedniego chłodzenia dla urządzeń górniczych wykorzystywanych do prac wydobywczych i urządzeń do drążenia tuneli w kopalni konieczny jest transport ochłodzonej wody rurociągami, nierzadko na znaczne odległości w obrębie kopalni podziemnej. Transport rurociągami nieuchronnie prowadzi do wzrostu temperatury wody wskutek wymiany ciepła poprzez ścianki rurociągu i wskutek tarcia związanego z oporem przepływu. Opracowane zostały modele teoretyczne wzrostu temperatury wody ochładzanej; na ich podstawie wskazano, że wzrost temperatury wody rozpatrywać należy jako oddziaływanie efektu synergii pomiędzy wymianą ciepła i ciepłem tarcia. Analiza teoretyczna wykazuje jednak, że przy poziomie błędu dopuszczalnego w praktyce inżynierskiej, wzrost temperatury wody traktować można jako zwykłą sumę wpływu wymiany ciepła i ciepła tarcia, tym samym znacznie upraszczając procedurę obliczeniową. Weryfikację wyników obliczeń otrzymanych w oparciu o dwie wymienione metody prze-prowadzono poprzez zbadanie przepływu wody w kopalni węgla, rurociągiem o długości 15 km złożonym z dwóch rodzajów rur, o wymiarach De 273 × 7 mm i De 377 × 10 mm. Wykazano, że różnica wyników uzyskanych dla obydwu metod nie przekraczała 0.04°C, przy założonym dopuszczalnym poziomie błędu. W odniesieniu do typowych rodzajów rur używanych do przesyłania wody ochłodzonej proponuje się ograniczenie dopuszczalnego spadku ciśnienia w przewodzie w granicach 100 Pa/m-400 Pa/m. Udział wzrostu temperatury wskutek oddziaływania sił tarcia waha się w granicach 24%-81% i rośnie wraz ze wzrostem prędkości przepływu i ze zmniejszaniem grubości ścianek rury. Jest więc rzeczą oczywistą, że wzrost temperatury wody wskutek oddziaływania sił tarcia nie może być pomijany i winien zostać odpowiednio uwzględniony przy obliczeniach wzrostu temperatury wody w rurociągu.
Źródło:
Archives of Mining Sciences; 2019, 64, 4; 785-796
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies