Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Solecka, B." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Application of Arduino Module to Research in Surface Physics
Autorzy:
Nowrot, A.
Solecka, B.
Powiązania:
https://bibliotekanauki.pl/articles/2064955.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
control systems
Arduino
photomagnetoelectric effect
Opis:
During the semiconductor or graphene wafers surface were investigated, the Arduino module was applied to control the impact point of the laser beam. While the pulse signal of laser beam impacts to surface selected material and the material is exposed to enough strong magnetic field, the photomagnetoelectric effect takes place. This causes the electrical signal in the measurement coil, which is connected to amplifiers. The paper presents application of Arduino UNO module to control the position in two dimensions (in the XY plane) of investigated silicon or graphene wafers while the photomagnetoelectric effect is measuring. The Arduino drive (through the integrated circuit with power transistors) the steps and shift of a dedicated table with a sample situated at the top of the table. Constructed equipment, based on Arduino board, allows for one step size of 1.25 μm in X-axis and Y-axis, and in effect, the each square millimeter contains 640000 measurement points. We are able also to modify the Arduino program for motors controller any moment. Moreover, it is also possible to apply the obtain method to investigate another semiconductor materials. The commercially available similar devices don’t have all need functions and they are incomparably more expensive.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2018, 1, 1; 295--300
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Photoelectromagnetic Investigations of Graphene
Autorzy:
Nowak, M.
Solecka, B.
Jesionek, M.
Powiązania:
https://bibliotekanauki.pl/articles/1376055.pdf
Data publikacji:
2014-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
72.80.Vp
73.50.Gr
73.50.Pz
78.67.Wj
Opis:
The photoelectromagnetic investigations of graphene has been performed using noncontact technique. The dependence of photoelectromagnetic response on magnetic field induction, illumination intensity for different photon energies, and frequency of illumination chopping is presented. We anticipate our paper to be a starting point for investigations of carrier diffusion length in this material. Such investigations should be essential for development of graphene electronic and optoelectronic devices.
Źródło:
Acta Physica Polonica A; 2014, 126, 5; 1104-1106
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dielectric Properties of SbSI in the Temperature Range of 292-475 K
Autorzy:
Starczewska, A.
Solecka, B.
Nowak, M.
Szperlich, P.
Powiązania:
https://bibliotekanauki.pl/articles/1376063.pdf
Data publikacji:
2014-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
77.80.Bg
78.40.Fy
Opis:
Methodology of impedance measurements and ferroelectric hysteresis loops observed in temperature range 292-475 K for antimony sulfoiodide (SbSI) grown from vapour phase are discussed. Temperature dependences of spontaneous polarization and coercive field of SbSI crystals are presented.
Źródło:
Acta Physica Polonica A; 2014, 126, 5; 1125-1127
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selekcjonowanie mocy strat blach transformatorowych w obwodach magnetycznych zamkniętych i otwartych
Autorzy:
Żurek, Z. H.
Solecka, B.
Wolnik, P.
Chmiela, B.
Powiązania:
https://bibliotekanauki.pl/articles/302395.pdf
Data publikacji:
2018
Wydawca:
Wydawnictwo Druk-Art
Tematy:
obwód magnetyczny
blacha transformatorowa
moc strat
magnetic circuit
power of losses
transformer plate
Opis:
Moc strat jest podstawowym parametrem przy projektowaniu maszyn i urządzeń elektrycznych. W przemyśle spotyka się blachy różnych producentów z różnych serii, dlatego zachodzi konieczność wstępnego szybkiego ich selekcjonowania pod względem mocy strat całkowitych. Oprócz metod Epsteina, międzynarodowe normy dopuszczają pomiary na pojedynczych arkuszach czy pasmach w metodach Single Sheet Testing (SST) dla grain-oriented Fe-Si sheet steel. W artykule porównano realizacje zastosowań koncepcji fizycznych i zastosowań NDT selekcjonowania stratności całkowitej blach transformatorowych z pomiaru składowych impedancji na pojedynczych próbkach paskowych otwartych i pojedynczych arkuszach blach. Do badań użyto arkuszy blach transformatorowych M130 z różnych serii poprodukcyjnych. Pomiary parametrów arkuszy blach transformatorowych wykonano na urządzeniu pomiarowym BROCKHAUS STS zgodnie z normami IEC 6040. Mostkiem pomiarowym AGILENT 4294A wyznaczano składowe impedancji cewki pomiarowej PCB (Texas Instrument) przylegającej do arkusza blachy. Niezależnie badano paski blachy transformatorowej (próbki otwarte) w solenoidzie. Pomiary wykonano w zakresie częstotliwości do 4 MHz. Pomiar w zakresie częstotliwości rezonansowej miał na celu ocenę użyteczności sondy pomiarowej LDC (TI) z cewką spiralną PCB.
Power loss is the basic parameter important for designers, in the construction of electrical machines and equipment. There are different magnetic steel sheets by various designers with various production series produced by industry. Therefore, it is necessary to pre-fast select them according to their total power loss. In this case, several methods are allowed by international standards, besides the Epstein apparatus (i. e. Single Sheet Tester (SST) for grain-oriented Fe-Si sheet steel). In the present paper, the comparison between the implementation of the physical concept and NDT applications and selection of total power loss of transformer shits was discussed. Investigations were carried out for single open strip samples and single transformer sheets by measured complex impedance components. M 130 type transformer sheets from different post-production series were used. The measurements of these sheets were carried out by applying BROKHAUS STS system according to the IEC 6040 standard. The complex components of impedance for a measure coil PCB (Texas Instrument), adhering to the sheet, were also measured by applying the precision RLC meter (AGILENT 4294A). Independently, the open strip samples were measured in a solenoid coil for the frequency up to 4 MHz. The resonant frequency measurements were carried out in order to test the LDC (TI) probe with a spiral measuring coil PCB.
Źródło:
Napędy i Sterowanie; 2018, 20, 5; 90-96
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact Strength of Austenitic and Ferritic-Austenitic Cr-Ni Stainless Cast Steel in -40 and +20°C Temperature
Udarność kwasoospornego staliwa Cr-Ni w temperaturze -40 i +20°C
Autorzy:
Kalandyk, B.
Zapała, R.
Boroń, Ł.
Solecka, M.
Powiązania:
https://bibliotekanauki.pl/articles/353749.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stainless cast steel
microstructure
impact strength
fractographic examination
staliwo nierdzewne
mikrostruktura
odporność na uderzenia
udarność
Opis:
Studies described in this paper relate to common grades of cast corrosion resistant Cr-Ni steel with different matrix. The test materials were subjected to heat treatment, which consisted in the solution annealing at 1060°C followed by cooling in water. The conducted investigations, besides the microstructural characteristics of selected cast steel grades, included the evaluation of hardness, toughness (at a temperature of -40 and +20°C) and type of fracture obtained after breaking the specimens on a Charpy impact testing machine. Based on the results of the measured volume fraction of ferrite, it has been found that the content of this phase in cast austenitic steel is 1.9%, while in the two-phase ferritic-austenitic grades it ranges from 50 to 58%. It has been demonstrated that within the scope of conducted studies, the cast steel of an austenitic structure is characterised by higher impact strength than the two-phase ferritic-austenitic (F-A) grade. The changing appearance of the fractures of the specimens reflected the impact strength values obtained in the tested materials. Fractures of the cast austenitic Cr-Ni steel obtained in these studies were of a ductile character, while fractures of the cast ferritic-austenitic grade were mostly of a mixed character with the predominance of brittle phase and well visible cleavage planes.
Zaprezentowane w artykule badania dotyczą popularnych gatunków kwasoodpornego staliwa Cr-Ni o różnej osnowie. Zastosowane do badań materiały poddano obróbce cieplnej (przesycanie w temperaturze 1060°C i chłodzenie w wodzie). Przeprowadzone badania oprócz charakterystyki mikrostruktury wybranych gatunków staliwa obejmowały ocenę twardości, udarności (w temperaturze -40 i +20°C) oraz charakteru przełomów uzyskanych w wyniku złamania próbek na młocie Charpie'go. Na podstawie uzyskanych wyników udziału objętościowego ferrytu stwierdzono, że w staliwie austenitycznym występuje 1.9% tej fazy, natomiast w dwóch staliwach ferrytyczno-austenitycznych (F-A) udział ferrytu mieścił się w przedziale 50÷58%. Wykazano, że staliwo o strukturze austenitycznej charakteryzuje się wyższą udarnością w porównaniu do dwufazowego staliwa ferrytyczno-austenitycznego (F-A). Zmiany jakie zaszły w charakterze przełomów próbek były odzwierciedleniem uzyskanych wyników udarności badanych materiałów. W zakresie przeprowadzonych badań przełomy austenitycznego staliwa Cr-Ni wykazują charakter ciągliwo-kruchy, a przełomy staliwa F-A są przeważnie przełomami o charakterze mieszanym z przewagą przełomu kruchego z widocznymi płaszczyznami łupliwości.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 3; 1103-1106
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies