Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sobusiak, A." wg kryterium: Autor


Tytuł:
Indirect shoot regeneration from leaf explants of Kalanchoe pinnata
Autorzy:
Andrzejewska, K.
Durska, A.
Kempa, M.
Kopec, P.
Sobusiak, A.
Stec, N.
Trzebny, A.
Powiązania:
https://bibliotekanauki.pl/articles/951233.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
shoot regeneration
leaf explant
Kalanchoe pinnata
Crassulaceae
micropropagation
histology
Źródło:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology; 2015, 96, 1
0860-7796
Pojawia się w:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytmy kondycjonowania sygnału fotopletyzmograficznego
The algorithms of photoplethysmographic signal conditioning
Autorzy:
Bołtrukiewicz, M.
Cysewska-Sobusiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/152089.pdf
Data publikacji:
2005
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
algorithms
photoplethysmographic signal conditioning
algorytmy
sygnał fotopletyzmograficzny
kondycjonowanie
Opis:
W pracy omówiono wybrane algorytmy przeznaczone do kondycjonowania sygnału fotopletyzmograficznego (PPG). Zaprezentowano konfigurację analogowej części toru akwizycji. Zaproponowano metodę określania pasma szumów i redukcji składowej o charakterze szumowym. Dokonano wyboru optymalnej metody segmentacji przebiegu. Zaproponowano algorytm do wykrywania patologicznych zaburzeń miarowości pracy serca. Zaprezentowano model przebiegu sygnału PPG i wyniki jego parametryzacji.
The selected algorithms of photoplethysmographic signal (PPG) conditioning have been described. The configuration of the analog part of an acquistion circuit was presented. The evaluation of the noise band and the method of noise component reduction have been proposed. The optimal method of PPG signal segmentation was selected. The algorithm for detectingpathological disturbances of the heart rhythm was proposed. The model of PPG waveform and results of its parameterization were presented.
Źródło:
Pomiary Automatyka Kontrola; 2005, R. 51, nr 9, 9; 22-25
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examples of computer-aided combined use of different methods of medical imaging
Autorzy:
Cysewska-Sobusiak, A.
Hulewicz, A.
Jukiewicz, M.
Krawiecki, Z.
Powiązania:
https://bibliotekanauki.pl/articles/97331.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
computer-aided systems
biomedical engineering
methods of imaging
stenting control
Opis:
This paper is devoted to interesting and difficult problems concerned with interdisciplinary biomedical engineering. The main purpose of the paper is to present rules and application of still developing modern methods of medical imaging combining properties of the selected techniques. The examples considered by the authors include combined applications of different methods of imaging such as: X-ray imaging, videoendoscopy, and ultrasonography. Some selected examples of effects obtained during real interventions assisted by combined imaging of operation site are shown in the paper. Examples of imaging the application of stents allowing for the performance of diagnostic and therapeutic procedures are also reported. Videoendoscopy imaging and X-ray imaging are two complementary methods applied during the interventions presented in stenting control. On the one hand, these methods facilitate a significant increase in diagnostics and treatment comfort. On the other hand, there is possibility to control stenting efficiency.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 511-520
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Komputerowe wspomaganie modelowania właściwości optycznych zbioru tkanek
Computer-aided modeling of optical properties of a tissue set
Autorzy:
Cysewska-Sobusiak, A.
Malitka, E.
Powiązania:
https://bibliotekanauki.pl/articles/152200.pdf
Data publikacji:
1999
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Opis:
Przedstawione zagadnienia dotyczą realizacji symulacji komputerowej interakcji światło-tkanki dla przyjetego modelu obiektu biologicznego o strukturze warstwowej. Zastosowanie opracowanego programu do modelowania właściwości optycznych niejednorodnego zbioru tkanek pozwala na tworzenie wirtualnych wariantów modeli oraz umożliwia ich adaptację i modyfikację.
Problems concerning computer simulation of light-tissue interaction for a model of the biological object, which a real layered composition has been assumed, are considered. The computer program worked out to aid modeling makes it possible to create virtual compositions of tissues and to do their modification.
Źródło:
Pomiary Automatyka Kontrola; 1999, R. 45, nr 7, 7; 49-52
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nieinwazyjne spektrofotometryczne monitorowanie utlenowania krwi
Noninvasive soectrophotometric monitoring of blood oxygenation
Autorzy:
Cysewska-Sobusiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/157137.pdf
Data publikacji:
2000
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Opis:
Wysycenie hemoglobiny tlenem (saturacja tlenowa) jest jednym z najważniejszych parametrów krwi tętniczej. Nieinwazyjne monitorowanie tej wielkości jest możliwe dzięki pulsooksymetrii - optoelektronicznej metodzie bazującej na detekcji i przetwarzaniu cyklicznych i selektywnych zmian optycznych parametrów żywych tkanek. W artykule przedstawiono ideę i właściwości pulsooksymetrii, uwypuklając jej zalety i ograniczenia. Zwrócono uwagę na złozone problemy wiarygodności pomiarów, obecne zastosowania i kierunki rozwoju. Uwzględniono stan wiedzy relacjonowany w dostępnych źródłach, dołączając do niego wyniki własnych analiz i experymentów.
The hemoglobin oxygen saturation is one of most important parameters of the arterial blood. Nonivasive monitoring of this quantity is possible using pulse oximetry - an optoelectronic diagnostic method based on blood-less detection and processing of cyclical and selective changes in optical properties of living tissues. in this article, the concept and characteristics of pulse oximetry, with special focus on its advantages and limitations, are presented. Complex problems with measurement reliability current application and tendency to development are discussed. The state-in-the art as well as results from the authorás own analyses and experiments are taken into account.
Źródło:
Pomiary Automatyka Kontrola; 2000, R. 46, nr 2, 2; 7-12
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan obecny i perspektywy rozwoju w dziedzinie biopomiarów
Status and perspectives of development in biomeasurements
Autorzy:
Cysewska-Sobusiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/152823.pdf
Data publikacji:
1999
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Opis:
Omówiono problemy fizjologiczne i techniczne występujące w pomiarach wykonywanych w celu identyfikacji cech organizmu człowieka. Skoncentrowano się na specyfice wykorzystywanych zjawisk, rodzaju mierzonych wielkości, stosowanych czujnikach i metodach pomiarowych oraz czynnikach warunkujących wiarygodność otrzymywanych wyników. Uwypuklono obecne znaczenie oraz perspektywy zastosowania w diagnostyce medycznej przetwarzania optoelektronicznego.
In the paper, some poblems referring to biomeasurements have been presented, with focus on phenomena to be utilized, kinds of quantities to be measured, types of measuring sensors and methods performed, and factors affecting reliability of results to be obtained. Important advantages of optoelectronic processing have been emphasized.
Źródło:
Pomiary Automatyka Kontrola; 1999, R. 45, nr 10, 10; 2-6
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tendencje rozwojowe i obszary zastosowań technik światłowodowych
Tendencies in Developing and Application of Fiberoptics
Autorzy:
Cysewska-Sobusiak, A.
Prokop, D.
Jukiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/376994.pdf
Data publikacji:
2017
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
światłowody
metrologia
optoelektronika
wideoendoskopia
Opis:
W artykule przedstawiono wybrane zagadnienia związane z nowoczesnymi technikami światłowodowymi. Przedstawiono wykorzystywane zjawiska fizyczne i optyczne oraz przedstawiono reprezentatywne przykłady współczesnych zastosowań różnych rodzajów światłowodów. Konwencjonalne układy światłowodowe są stosowane w nowoczesnej aparaturze pomiarowej, urządzeniach przemysłowych i medycznych oraz powszechnego użytku. Przedstawiono również specyficzne właściwości i obszary zastosowań światłowodów fotonicznych, które należą do najszybciej rozwijających się dziedzin przemysłu związanego ze współczesną fotoniką.
In the paper some selected problems concerned with modern techniques based on optical fibers are presented. Physical and optical phenomena and the selected examples of the current applications of different kinds of optical fibers are presented. Fiberoptics systems made for modern metrological, industrial, medical and common use are mentioned. Specific properties and application areas of photonic fiberoptics are also presented. Photonic crystal fibers area still develops very rapidly.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2017, 89; 205-217
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie w biopomiarach transmisyjnego wariantu światło-tkanki
Using the transmission variant of light-tissue interaction in biomeasurements
Autorzy:
Cysewska-Sobusiak, A.
Wiczyński, G.
Krawiecki, Z.
Odon, A.
Powiązania:
https://bibliotekanauki.pl/articles/152344.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
biopomiar
optoelektronika
transiluminacja
biomeasurements
optoelectronics
transillumination
Opis:
W referacie omówiono wybrane zagadnienia dotyczące metrologicznych aspektów wykorzystywania optycznych właściwości tkanek w biopomiarach bazujących na transmisyjnym wariancie zachodzących interakcji. Przedstawiono przykłady współczesnych zastosowań technik transiluminacyjnych w nieinwazyjnej inżynierii biomedycznej.
In the paper some selected questions concerned metrological aspects of using tissue physics and optics in biomeasurements based on the transmission variant of occurring interactions are considered. Examples of modern applications of transillumination techniques in noninvasive biomedical engineering are presented.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 390-393
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Znaczenie metrologii i inżynierii pomiarowej we współczesnym kształceniu interdyscyplinarnym
Significance of metrology and measurement engineering in the modern interdisciplinary education
Autorzy:
Cysewska-Sobusiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/267761.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
metrologia
biopomiar
inżynieria pomiarowa
kształcenie interdyscyplinarne
metrology
biomeasurements
measurement engineering
interdisciplinary education
Opis:
Pomiary są nieodłącznym elementem zawodowego i codziennego życia każdego człowieka. Umiejętność przeprowadzania pomiaru polega m.in. na dobraniu takich metod i aparatury oraz warunków, by uzyskana dokładność była wystarczająca. W niniejszym artykule, nawiązując do wyzwań współczesnej metrologii, zwrócono uwagę na zauważalne w niej tendencje do rozwoju nowych technik i narzędzi pomiarowych. Podkreślono wagę, jaką dla sprawności realizacji interdyscyplinarnych zadań dydaktycznych ma jedność nauczania i badań naukowych. Zwrócono także uwagę na znaczenie aktywizacji studentów.
Measurements are the inherent elements of human professional and everyday life. In the article, linking to the challenges of the present metrology, the attention was paid to perceptible in her tendencies to the development of new techniques and measuring tools. The unity of teaching and scientific investigations is considered because of its positive influence on the efficiency of the realization of interdisciplinary didactic tasks. The attention was also turned on the great importance of students activation. One of the most important didactic tasks is to encourage the students to explore the complex interdisciplinary fields. The nature of the topics is reflected in how the lectures and laboratory experiments are accepted and understood by students. There is necessity to work well in a well-integrated interdisciplinary team. The influence of important relation between teachers and students on efficiency of education should be taken into consideration. Authoress in many places used her own experience acquired within many years of work with measuring equipment and many years of the teaching of metrological subjects.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 59; 25-28
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikroprocesorowe urządzenie do numeracji pakietów UDP
The microprocessor device for numbering of UDP packets
Autorzy:
Hulewicz, A.
Bołtrukiewicz, M.
Prokop, D.
Cysewska-Sobusiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/152106.pdf
Data publikacji:
2005
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mikroprocesorowe urządzenie do numeracji pakierów
pakiety UDP
microprocessor device for numbering
UDP packets
Opis:
Najistotniejszą wadą protokołu UDP jest brak synchronizacji pomiędzy wysyłaniem i odbiorem kolejnych pakietów. Ten problem można rozwiązać poprzez nadawanie pakietom numerów, które były zapisywane w pierwszych bajtach pakietu. Ponieważ profesjonalne medyczne urzadzenia pomiarowe, dysponujące możliwością transmisji danych, nie są wyposażone w opcje przygotowania pakietów UDP, zadanie numeracji pakietów powierzono dodatkowemu urządzeniu mikroprocesorowemu, które umieszczono pomiędzy medycznym urządzeniem pomiarowym a transeiverem GPRS. W pracy przeprowadzono analizę konstrukcji urządzenia mikroprocesorowego przeznaczonego do numeracji pakietów UDP oraz opisano jego właściwości sprzętowe i programowe.
In the UDP protocol, data are transmitted in packets, but the synchronization between transmission and reception of successive packet is not ensured. This problem can be solved by the use of packets numbering. The numbers can be calculated and written as a first and second byte of packets. Because the professional medical measurements devices cannot number data packets, the numbering of data packets can be performed with a specialized additional device, placed between the medical devices and GPRS transceiver. In the paper, the microprocessor device for UDP packets numbering has been described. The attributes of hardware and software have been discussed.
Źródło:
Pomiary Automatyka Kontrola; 2005, R. 51, nr 9, 9; 34-36
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wieloogniskowe wzrokowe potencjały wywołane - problemy metrologiczne oraz korzyści diagnostyczne
Multifocal visual evoked potentials - metrological problems and diagnostic benefits
Autorzy:
Hulewicz, A.
Cysewska-Sobusiak, A.
Grzybowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/153640.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
badania elektrofizjologiczne
wieloogniskowe wzrokowe potencjały wywołane
przedziały tolerancji
electrophysiological examinations
multifocal visual evoked potentials
tolerance intervals
Opis:
Tematyka referatu dotyczy problemów metrologicznych występujących w wieloogniskowych badaniach wzrokowych potencjałów wywołanych (M-VEP) oraz korzyści diagnostycznych wynikających z przeprowadzania tych badań. Przedstawione w referacie wyniki dotyczą rzeczywistych przebiegów M-VEP. Porównano wyniki uzyskiwane w badaniach M-VEP i w badaniach perymetrycznych. Zilustrowano występujące problemy, wskazując w szczególności na wpływ takich czynników jak odpowiednia korekcja wady wzroku, zapewnienie właściwej pozycji podczas badania oraz znaczny rozrzut wyników powstający wskutek tzw. fiksacji oka.
The paper deals with metrological problems connected with multifocal visual evoked potentials (M-VEP) and their diagnostic benefits. The presented results concern some real M-VEP signals which were acquired. Comparison of results obtained during M-VEP examinations with perimeter examinations has been made. The problems to be occurred have been illustrated with special focus on proper correction of sight defects, right position of patients during examination, and significant dispersion of results caused by the so-called eye fixation.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 386-389
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finding Optimal Frequency and Spatial Filters Accompanying Blind Signal Separation of EEG Data for SSVEP-based BCI
Autorzy:
Jukiewicz, M.
Buchwald, M.
Cysewska-Sobusiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/226812.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
BCI
SSVEP
BSS
FastICA
AMUSE
Infomax
Extended Infomax
CAR
Large Laplacian
Small Laplacian
CCA
Opis:
Brain-computer interface (BCI) is a device which allows paralyzed people to navigate a robot, prosthesis or wheelchair using only their own brains reactions. By creating a direct communication pathway between the human brain and a machine, without muscles contractions or activity from within the peripheral nervous system, BCI makes mapping persons intentions onto directive signals possible. One of the most commonly utilized phenomena in BCI is steady-state visually evoked potentials (SSVEP). If subject focuses attention on the flashing stimulus (with specified frequency) presented on the computer screen, a signal of the same frequency will appear in his or hers visual cortex and from there it can be measured. When there is more than one stimulus on the screen (each flashing with a different frequency) then based on the outcomes of the signal analysis we can predict at which of these objects (e.g., rectangles) subject was/is looking at that particular moment. Proper preprocessing steps have taken place in order to obtain maximally accurate stimuli recognition (as the specific frequency). In the current article, we compared various preprocessing and processing methods for BCI purposes. Combinations of spatial and temporal filtration methods and the proceeding blind source separation (BSS) were evaluated in terms of the resulting decoding accuracy. Canonical-correlation analysis (CCA) to signals classification was used.
Źródło:
International Journal of Electronics and Telecommunications; 2018, 64, 4; 439-444
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implementation of Bilinear Separation algorithm as a classification method for SSVEP-based brain-computer interface
Autorzy:
Jukiewicz, M.
Cysewska-Sobusiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/114357.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
brain-computer interface
SSVEP
bilinear separation
support vector machine (SVM)
Opis:
: The aim of this study was to create a two-class brain-computer interface. As in the case of research on SSVEP stimuli flashing at different frequencies were presented to four subjects. Optimal SSVEP recognition results can be obtained from electrodes: O1, O2 and Oz. In this work SVM classifier with Bilinear Separation algorithm have been compared. The best result in the offline tests using Bilinear Separation was: average accuracy of stimuli recognition 93% and ITR 33.1 bit/min, SVM: 90% and 32.8 bit/min.
Źródło:
Measurement Automation Monitoring; 2015, 61, 2; 51-53
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low-cost evoked potentials detection for brain computer-interfaces
Autorzy:
Jukiewicz, M.
Cysewska-Sobusiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/97604.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
brain-computer interface
detection of evoked potentials
EEG
signal processing
MATLAB
Opis:
Evoked potentials are one of the brain's electrical activity types. They appear on the human scalp as a result of a registration of an external stimulus (e.g. an appearance or a change of a sound, a flash of light or an image). Generally, they are used in medical diagnosis, but they also may be used in brain-computer interfaces. In this chapter a laboratory set for the acquisition and analysis of evoked potentials is described. The main part of this set is a photostimulator consisting of sixteen LEDs and the ATmega 328 microcontroller. The software created by the authors allows for: connection between EEG device, stimulator and computer, input stimulus control, output signal filtering and its classification. The presented set may support a process of brain-computer interface design.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 102-110
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko laboratoryjne do pomiaru i analizy potencjałów wywołanych
Laboratory stand for acquisition and analysis of evoked potentials
Autorzy:
Jukiewicz, M.
Cysewska-Sobusiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/376058.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
interfejs mózg-komputer
potencjały wywołane
stanowisko laboratoryjne
MATLAB
Opis:
Elektryczna aktywność mózgu to między innymi potencjały wywołane, które są mierzalne na powierzchni głowy w wyniku zarejestrowania przez człowieka zewnętrznego bodźca (np. obrazu, dźwięku). Są one wykorzystywane zwykle w diagnostyce medycznej, ale trwają także intensywne prace nad wykorzystaniem ich w tak zwanych interfejsach mózg-komputer. W artykule opisano stanowisko laboratoryjne do pomiaru i analizy potencjałów wywołanych, utworzone na bazie oprogramowania MATLAB. Do akwizycji sygnału z powierzchni czaszki wykorzystano elektroencefalograf (EEG). Ponadto stanowisko jest wyposażone w fotostymulator, zbudowany z szesnastu diod LED i mikrokontrolera ATmega 328. Przygotowane oprogramowanie pozwala na: ustanowienie połączenia pomiędzy EEG, fotostymulatorem oraz komputerem, sterowanie bodźcami (w zależności od oczekiwanego potencjału wywołanego), filtrację zebranego sygnału i jego klasyfikację za pomocą algorytmów statystycznego uczenia maszynowego. Stanowisko wspomaga projektowanie prostych interfejsów-mózg komputer.
One type of brain's electrical activity are evoked potentials. They appear on the scalp as a result of a registration of an external stimulus (e.g. an appearance or a change of a sound, a flashing light or an image). Generally they are used in medical diagnosis, but they are also used in brain computer-interfaces. In this article laboratory stand for acquisition and analysis of evoked potentials is described. One of the main part of this stand is a stimulator (consisting of sixteen LEDs and a microcontroller ATmega 328). The software created by the authors allows: connection between EEG device, stimulator and computer, stimulus control, signal filtering and its classification. The presented laboratory stand may support brain-computer interface design process.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 82; 261-266
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies