Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Soares, J. C." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Analysis of Atmospheric Aerosols Using the Lisbon Nuclear Microprobe
Autorzy:
Rita, E. M. C.
Alves, L. C.
Reis, M. A.
Rodrigues, F.
Fialho, P.
Soares, J. C.
Powiązania:
https://bibliotekanauki.pl/articles/2029003.pdf
Data publikacji:
2001-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
92.20.Bk
92.60.Mt
78.70.En
82.80.Yc
Opis:
The nuclear microprobe installed at Instituto Tecnológico e Nuclear, in Lisbon, was used in the analysis of aerosols collected at the Azores islands. Samples from two different aerosol groups were analysed. One referred to aerosols that were carried from North America and the other one contained aerosols that were carried from the Sahara desert and crossed over Europe. Coarse and fine fractions were analysed for each aerosol group and two-dimensional elemental maps were constructed, which allowed the identification of several individual particles. For particles of interest, elemental spatial correlations and dimensions were determined and point analysis was also carried out (depth information was achieved by fitting Rutherford backscattering spectra). Some of these particles are quite interesting. For instance, in the fine fraction of the aerosols that were carried from North America, particles were found with Cu and Cl in the atomic proportion 1:2 and with dimensions 15×15×15μm$\text{}^{3}$, and in the corresponding coarse fraction a particle with K and S was identified, with dimensions 28×35×30μm$\text{}^{3}$. Some differences were found between the aerosols groups. One example of these are Ti particles (fine fraction) and Rb (coarse fraction) that were identified in one group (Sahara desert and Europe), but not in the other
Źródło:
Acta Physica Polonica A; 2001, 100, 5; 781-788
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combined Analyses of Ion Beam Synthesized Layers in Porous Silicon
Autorzy:
Ramos, A. R.
Pászti, F.
Horváth, Z. E.
Vázsonyi, É.
Conde, O.
da Silva, M. F.
da Silva, M. R.
Soares, J. C.
Powiązania:
https://bibliotekanauki.pl/articles/2028988.pdf
Data publikacji:
2001-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.10.-i
61.18.Bn
61.43.Gt
68.55.Ln
Opis:
High dose ion implantation was used to form polycrystalline silicide films on porous silicon with different native concentrations of light impurities (C and O). Porous silicon layers severalμm thick were implanted with 170 keV Cr$\text{}^{+}$ ions to fluences of 3×10$\text{}^{17}$ ions/cm$\text{}^{2}$ both at room temperature and 450ºC. Similar samples were implanted with 100 keV Co$\text{}^{+}$ ions to fluences of 2×10$\text{}^{17}$ ions/cm$\text{}^{2}$ at room temperature, 350ºC, and 450ºC. The formed silicide compounds were studied by Rutherford backscattering spectrometry, elastic recoil detection, glancing incidence X-ray diffraction, and four point-probe sheet resistance measurements. Selected Co implanted samples were analysed by cross-section transmission electron microscopy. Results show that the light impurities were partially expelled from the forming silicide layer. Combining cross-section transmission electron microscopy with ion beam methods it was possible to show that, in the implanted region, the porous structure collapses and densifies during implantation, but the underlying porous silicon remains intact. The layer structure, as well as the quality and type of the formed silicide, were found to depend on the original impurity level, implantation temperature, and annealing.
Źródło:
Acta Physica Polonica A; 2001, 100, 5; 773-780
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimisation of the preventive maintenance plan of a series components system with Weibull hazard function
Autorzy:
Duarte, J. C.
Soares, C. G.
Powiązania:
https://bibliotekanauki.pl/articles/2069578.pdf
Data publikacji:
2007
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
availability
hazard function
Weibull distribution
preventive maintenance
series components
Opis:
In this paper we propose an algorithm to calculate the optimum frequency to perform preventive maintenance in equipment that exhibits Weibull hazard function and constant repair rate in order to ensure its availability. Based on this algorithm we have developed another one to solve the problem of maintenance management of a series system based on preventive maintenance over the different system components. We assume that all components of the system still exhibit Weibull hazard function and constant repair rate and that preventive maintenance would bring the system to the as good as new condition. The algorithm calculates the interval of time between preventive maintenance actions for each component, minimizing the costs, and in such a way that the total downtime, in a certain period of time, does not exceed a predetermined value.
Źródło:
Journal of Polish Safety and Reliability Association; 2007, 1; 67--73
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fatigue design and prevention in movable scaffolding systems
Projektowanie ruchomych systemów rusztowań z uwzględnieniem obciążęń zmęczeniowych
Autorzy:
Coelho, H.
Torres, A.
Pacheco, P.
Moreira, C.
Silva, R.
Soares, J. M.
Pinto, D.
Powiązania:
https://bibliotekanauki.pl/articles/396185.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
mosty
Movable Scaffolding System
MSS
system ruchomych rusztowań
obciążenia zmęczeniowe
bridge construction
fatigue
Opis:
The Movable Scaffolding System (MSS) is a heavy construction equipment used for casting situ of concrete bridge decks. In the past decades, MSSs have become increasingly complex and industrialized, enlarging its span ranges, incorporating auxiliary elevation machinery and increasing productivity. The tendency nowadays is for strong reutilization and the notion of MSS as a disposable or temporary structure is somehow reductive. The main structure of MSSs may be potentially exposed to fatigue, usually characterized by low number of cycles with significant stress amplitude. Fatigue may be prevented through adequate design; judicious selection of materials; demanding quality control and implementation of robust inspection and maintenance plans.
System ruchomych rusztowań – Movable Scaffolding System (MSS) to ciężki konstrukcja budowlana wspomagająca wykonanie betonowych mostów. W ostatnich dekadach MSS stały się coraz bardziej skomplikowane i uniwersalne, stanowią element nośny dla wielu urządzeń zarówno podczas wykonywania mostu jak i podczas eksploatacji. Główna struktura systemów MSS może być narażona na efekt zmęczenia, obiążenia zwykle charakteryzują się niską liczbą cykli o znacznej amplitudzie naprężeń. Zmęczeniu można zapobiec poprzez odpowiedni projekt i rozsądny dobór materiałów. Jest to konstrukcja wymagająca ścisłej kontroli jakości i wdrożenia solidnych planów inspekcji i konserwacji.
Źródło:
Civil and Environmental Engineering Reports; 2017, No. 25(2); 77-88
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Expression on hypoxia-inducible factor-1α in human tegumentary leishmaniosis caused by Leishmania braziliensis
Autorzy:
Rocha, F.J.S.
Pereira, C.L.D.
de Melo, F.L.
Soares, C.R.P.
Paz, S.T.
Giorgio, S.
Powiązania:
https://bibliotekanauki.pl/articles/6320.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Parazytologiczne
Źródło:
Annals of Parasitology; 2018, 64, 1
0043-5163
Pojawia się w:
Annals of Parasitology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies