Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Składzień, M." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Application of the GTN Model to Numerical Simulation of Distaloy AB Sinters Behaviour Under Complex Loading Conditions
Autorzy:
Madej, L.
Perzyński, K.
Składzień, M.
Tkocz, M.
Rosiak, M.
Grosman, F.
Powiązania:
https://bibliotekanauki.pl/articles/350850.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
numerical modelling
porous sinters
deformation
Opis:
The behaviour of porous sinters, during compression and compression with reverse cyclic torsion tests is investigated in the article based on the combination of experimental and numerical techniques. The sinters manufactured from the Distaloy AB powder are examined. First, series of simple uniaxial compression tests were performed on samples with three different porosity volume fractions: 15, 20 and 25%. Obtained data were then used during identification procedure of the Gurson-Tvergaard-Needleman finite element based model, which can capture influence of porosity evolution on plasticity. Finally, the identified Gurson-Tvergaard- Needleman model was validated under complex compression with reverse cyclic torsion conditions and proved its good predictive capabilities. Details on both experimental and numerical investigations are presented within the paper.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 4; 1937-1942
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heating system with vapour compressor heat pump and vertical U-tube ground heat exchanger
Autorzy:
Hanuszkiewicz-Drapała, M.
Składzień, J.
Powiązania:
https://bibliotekanauki.pl/articles/240620.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gruntowy wymiennik ciepła
modelowanie numeryczne
pompa ciepła
system grzewczy
ground heat exchanger
heat pump
heating system
numerical modelling
Opis:
In the paper a heating system with a vapour compressor heat pump and vertical U-tube ground heat exchanger for small residential house is considered. A mathematical model of the system: heated object - vapour compressor heat pump - ground heat exchanger is presented shortly. The system investigated is equipped, apart from the heat pump, with the additional conventional source of heat. The processes taking place in the analyzed system are of unsteady character. The model consists of three elements; the first containing the calculation model of the space to be heated, the second the vertical U-tube ground heat exchanger with the adjoining area of the ground. The equations for the elements of vapour compressor heat pump form the third element of the general model. The period of one heating season is taken into consideration. The results of calculations for two variants of the ground heat exchanger are presented and compared. These results concern variable in time parameters at particular points of the system and energy consumption during the heating season. This paper presents the mutual influence of the ground heat exchanger subsystem, elements of vapour compressor heat pump and heated space.
Źródło:
Archives of Thermodynamics; 2010, 31, 4; 93-110
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal analysis of heat and power plant with high temperature reactor and intermediate steam cycle
Autorzy:
Fic, A.
Składzień, J.
Gabriel, M.
Powiązania:
https://bibliotekanauki.pl/articles/239939.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cogeneration system
high-temperature reactor
exergy analysis
gas heat pumps
numerical simulation
system kogeneracyjny
reaktor wysokotemperaturowy
analiza egzergii
gazowe pompy ciepła
symulacja numeryczna
Opis:
Thermal analysis of a heat and power plant with a high temperature gas cooled nuclear reactor is presented. The main aim of the considered system is to supply a technological process with the heat at suitably high temperature level. The considered unit is also used to produce electricity. The high temperature helium cooled nuclear reactor is the primary heat source in the system, which consists of: the reactor cooling cycle, the steam cycle and the gas heat pump cycle. Helium used as a carrier in the first cycle (classic Brayton cycle), which includes the reactor, delivers heat in a steam generator to produce superheated steam with required parameters of the intermediate cycle. The intermediate cycle is provided to transport energy from the reactor installation to the process installation requiring a high temperature heat. The distance between reactor and the process installation is assumed short and negligable, or alternatively equal to 1 km in the analysis. The system is also equipped with a high temperature argon heat pump to obtain the temperature level of a heat carrier required by a high temperature process. Thus, the steam of the intermediate cycle supplies a lower heat exchanger of the heat pump, a process heat exchanger at the medium temperature level and a classical steam turbine system (Rankine cycle). The main purpose of the research was to evaluate the effectiveness of the system considered and to assess whether such a three cycle cogeneration system is reasonable. Multivariant calculations have been carried out employing the developed mathematical model. The results have been presented in a form of the energy efficiency and exergy efficiency of the system as a function of the temperature drop in the high temperature process heat exchanger and the reactor pressure.
Źródło:
Archives of Thermodynamics; 2015, 36, 1; 3-18
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A model of hydrogen passive autocatalytic recombiner and its validation via CFD simulations
Autorzy:
Orszulik, M.
Fic, A.
Bury, T.
Składzień, J.
Powiązania:
https://bibliotekanauki.pl/articles/240045.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nuclear reactor
containment
hydrogen
numerical modeling
CFD
reaktor jądrowy
powstrzymywanie
wodór
modelowanie numeryczne
Opis:
Passive autocatalytic recombiners (PAR) is the only used method for hydrogen removal from the containment buildings in modern nuclear reactors. Numerical models of such devices, based on the CFD approach, are the subject of this paper. The models may be coupled with two types of computer codes: the lumped parameter codes, and the computational fluid dynamics codes. This work deals with 2D numerical model of PAR and its validation. Gaseous hydrogen may be generated in water nuclear reactor systems in a course of a severe accident with core overheating. Therefore, a risk of its uncontrolled combustion appears which may be destructive to the containment structure.
Źródło:
Archives of Thermodynamics; 2013, 34, 4; 257-266
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Otoimplant - a new middle ear prosthesis as an alternative medical device in operative treatment of hearing
Autorzy:
Ziąbka, M.
Dziadek, M.
Menaszek, E.
Banasiuk, R.
Królicka, A.
Wiatr, A.
Wiatr, M.
Składzień, J.
Powiązania:
https://bibliotekanauki.pl/articles/285363.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
otoimplant
ear prosthesis
operative treatment
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 47
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies