Tytuł:
The evaluation of the influence of head implant surface roughness on the wear of UHMWPE cup
Autorzy:
Sedlacek, R.
Tuzarova, Z.
Powiązania:
https://bibliotekanauki.pl/articles/286109.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
implants
head surface roughness
UHMWPE
Opis:
The aim of this study was the evaluation of the influence of head surface roughness on the wear of the acetabular component of implant. The experiments were executed for the combination of UHMWPE (Ultra High Molecular Weight Polyethylene) implant cup and metal head of implant with several different surface roughnesses. Testing method was based on Pin-on-Disc principle. Finally the recommendation for head surface roughness was established. The special experiments were carried out in accredited “Mechanical Testing Laboratory” (quality system ISO 17025) in collaboration with the Academy of Sciences of the Czech Republic and company BEZNOSKA Corporation - developing and producing bone-substitute biomaterials and implants.
Źródło:
Engineering of Biomaterials; 2008, 11, no. 77-80; 13-14
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of the influence of UHMWPE modification on the wear resistance
Autorzy:
Sedlacek, R.
Vondrova, J.
Powiązania:
https://bibliotekanauki.pl/articles/285018.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
UHMWPE
wear resistance
Źródło:
Engineering of Biomaterials; 2007, 10, no. 63-64; 2-4
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Direct Comparison of Analogue and Digital FGPA-Based Approaches to Synchronous Detection
Autorzy:
Teren, O.
Tomlain, J.
Sedlacek, R.
Powiązania:
https://bibliotekanauki.pl/articles/221544.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
synchronous detection
lock-in amplifier
digital signal processing
FPGA
measurement of impedance
Opis:
This paper deals with a comparison between digital and analogue implementation of a synchronous detection algorithm. The commonly used implementation methods of synchronous detection are presented in the paper. The paper describes FPGA-based digital and analogue hardware approaches, focusing on the digital design. The characteristics of used analogue-to-digital converters are measured. Both proposed approaches are directly compared in terms of sensitivity and long-term stability. The achieved results, along with identified limitations and proposed improvements are widely discussed.
Źródło:
Metrology and Measurement Systems; 2018, 25, 1; 57-69
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elastic modulus determination on osteoporotic rat bones by the three-point bending test and nanoindentation
Autorzy:
Vondrova, J.
Lukes, J.
Sedlacek, R.
Ruzicka, P.
Powiązania:
https://bibliotekanauki.pl/articles/284776.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
osteoporosis
treatment
bones
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 6-8
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Heating Parameters on Flow Stress Curves of Low-Alloy Mn-Ti-B Steel
Autorzy:
Kawulok, P.
Schindler, I.
Kawulok, R.
Opěla, P.
Sedláček, R.
Powiązania:
https://bibliotekanauki.pl/articles/354445.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
initial austenition grain size
peak stress
peak strain
Mn-Ti-B steel
Opis:
Influence of the initial grain size on hot deformation behavior of the low-alloy Mn-Ti-B steel was investigated. The uniaxial compression tests were performed in range of the deformation temperatures of 900-1200°C and strain rates of 0.1-10 s-1. One set of samples was heated directly to the deformation temperature, which corresponded to the initial austenitic grain size of 19-56 μm; the other set of samples was uniformly preheated at the temperature of 1200°C. Whereas the values of activation energy, peak stress and steady-state stress values practically did not depend on the initial austenitic grain size, the peak strain values of coarser-grained structure significantly increase mainly at high values of the Zener-Hollomon parameter. This confirms the negative effect of the large size of the initial grain on the dynamic recrystallization kinetics, which can be explained by the reduction in nucleation density.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 4; 1785-1792
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydrolytic decomposition in a polyamide/PDMS composite for orthopaedic usage
Autorzy:
Sochor, M.
Balik, K.
Sucharda, Z.
Suchy, T.
Sedlacek, R.
Powiązania:
https://bibliotekanauki.pl/articles/284724.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
tissue engineering
hydrolitic decomosition
orthopaedics
Źródło:
Engineering of Biomaterials; 2011, 14, 103; 2-3
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterilization decomposition evaluation of composite materials based on carbon fibers for use in medicine
Autorzy:
Sedlacek, R.
Suchy, T.
Balik, K.
Sochor, M.
Sucharda, Z.
Powiązania:
https://bibliotekanauki.pl/articles/283909.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
composites
carbon fibers
biomaterials
Źródło:
Engineering of Biomaterials; 2011, 14, no. 109-111 spec. iss.; 9-10
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The evaluation of adhesion between electrospun collagen layers and different titanium substrates
Autorzy:
Sedlacek, R.
Suchy, T.
Supova, M.
Sucharda, Z.
Kuzma, J.
Horny, L.
Powiązania:
https://bibliotekanauki.pl/articles/285558.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
antibiotic treatment
collagen layers
titanium alloys
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 16
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bioinspired nanocomposite structures for bone tissue regeneration based on collagen, gelatin, polyamide and hydroxyapatite
Autorzy:
Suchy, T.
Balik, K.
Supova, M.
Hruskova, D.
Sucharda, Z.
Cerny, M.
Sedlacek, R.
Powiązania:
https://bibliotekanauki.pl/articles/286173.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
nanocomposites
bone tissue regeneration
biomaterials
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 13-15
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena niektórych metod jodometrycznych do oznaczania liczby nadtlenkowej tłuszczów i własne modyfikacje tej metody
The evaluation of some iodometric methods for the estimation of peroxide number of fats and modifications of this methods
Autorzy:
Sedlacek, B.A.J.
Rybin, R.
Raab, J.M.
Bartonicek, M.
Powiązania:
https://bibliotekanauki.pl/articles/874546.pdf
Data publikacji:
1956
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
metoda jodometryczna
ocena
roztwory
odczynniki
badania naukowe
tluszcze
iodometric method
evaluation
solution
chemical
scientific research
fat
Źródło:
Roczniki Państwowego Zakładu Higieny; 1956, 07, 4
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies