Tytuł:
Simultaneous determination of Aspirin and Rosuvastatin Calcium in capsules by using RP-HPLC coupled with photo diode array detection
Autorzy:
Panchal, A.
Sanghvi, G.
Vachhani, A.
Sheth, N.
Vaishnav, D.
Powiązania:
https://bibliotekanauki.pl/articles/412028.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
aspirin
rosuvastatin calcium
RP-HPLC
capsule
validation
Opis:
A simple, sensitive, specific, and cost effective method for simultaneous determination of Aspirin and Rosuvastatin calcium was developed and validated in single dosage formulation. The sample solution of ASP and RSTC was prepared using methanol as a solvent. Separation of ASP and RSTC was achieved with a mobile phase consisting of 20 mM KH2PO4 : Methanol (30:70 v/v) at a flow rate of 1.0 ml/min. Separations were performed on Merck hibar 250-4.6 RP18 (5 μm) column (150 mm X 3.0 mm), using a Shimadzu Prominence HPLC system equipped with a Shimadzu SPD-20A detector, Rhenodyne 7725i injector with 20 μL loop, LC-20 AD pump, CBM-20 Alite controller and LC Solution software. Retention times of ASP and RSTC were 3.747 and 5.969 minutes respectively. Absolute recovery of ASP and RSTC was 100.3 and 100.03 % respectively. The lower limit of quantification (LLOQ) of ASP and RSTC was 0.3097 and 0.1063 ppm and lower limit of detection (LLOD) of ASP and RSTC was 0.01535 and 0.01358 ppm respectively. Linearity was established for the range of concentrations 15.00-90.0 μg/ml and 2.0-12.0 μg/ml for ASP and RSTC respectively with the coefficient of determination (R2) of 0.994 and 0.999 for both the compounds. The inter- and intra-day precision in the measurement of ASP quality control (QC) sample 75 μg/ml, were in the range 0.1-0.2 % relative standard deviation (R.S.D.) and 0.2-0.3 % R.S.D., respectively. The inter- and intra-day precision in the measurement of RST quality control (QC) sample 10 μg/ml, were in the range 0.1-0.2 % R.S.D., and 0.0-0.3 % R.S.D., respectively. The developed method would be applicable for routine quality control of ASP And RSTC in bulk as well as in pharmaceutical formulations.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2014, 14, 2; 218-230
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies