Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sangeetha, Palanivelu" wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Analytical study on the behaviour of composite space truss structures with openings in a concrete slab
Autorzy:
Sangeetha, Palanivelu
Powiązania:
https://bibliotekanauki.pl/articles/396637.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
composite structure
space truss
slab openings
maximum load
maximum deflection
ANSYS
konstrukcje kompozytowe
kratownice przestrzenne
płyty
maksymalne obciążenie
ugięcie
Opis:
A space truss structural system is a three-dimensional arrangement of linear elements in a pyramid pattern forming a Double Layer Grid (DLG) system. Space trusses are an elegant and economical means of covering larger areas such as roof systems, in a wide variety of applications such as a stadium, aircraft-hanger, assembly hall, etc. The major problem encountered in using the space truss as a roofing system is the sudden failure of the whole structure due to critical buckling of the top chord member. Earlier research has shown that the optimal solution to overcome such a failure is by providing a small thickness of concrete slab over the space truss, so that the space truss with concrete slab (Composite Space Truss) will act as a floor system for the multi-storey building. For better ventilation and lighting in the building, the need for openings in the composite space truss is unavoidable; however, providing an opening in the concrete slab will reduce the load carrying capacity of the structure. The analysis of a composite space truss of size 30m x 30m with all possible locations of openings for four different support conditions was carried out using ANSYS in order to study the load - deflection behaviour. Further, the ductility factor and energy absorption capacity of the composite space truss with different locations of slab openings were compared.
Źródło:
Civil and Environmental Engineering Reports; 2020, 30, 3; 265-280
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flexural Strength of Steel-Concrete Composite Beams Under Two-Point Loading
Autorzy:
Sangeetha, Palanivelu
Ramana Gopal, S.
Jai Vigneshwar, A.
Vaishnavi, K.
Srinidhi, A.
Powiązania:
https://bibliotekanauki.pl/articles/1838063.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
composite beam
steel-concrete beam
flexural strength
decking sheet
connector
load
ANSYS
belka zespolona
belka stalowo-betonowa
złącze
obciążenie
odkształcenie
Opis:
This study investigates the flexural strength of simply-supported steel–concrete composite beams under two-point loading. A total of four specimens were tested to failure for varying parameters including type of connectors (stud and channel) and number of connectors (two and four). ANSYS software was used to establish the finite element models that can simulate the flexural behaviour of the composite beam. The test results show that a beam with channel connectors performs better than a beam with stud connectors. The composite beam with two connectors between the beam and slab causes additional deflection due to slippage in the connectors, when compared to the beam with four connectors. The results from the analytical model are in good agreement with the experimental results.
Źródło:
Civil and Environmental Engineering Reports; 2020, 30, 4; 21-32
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flexural behaviour of a cold-formed steel-concrete composite beam with channel type shear connector – an experimental and analytical study
Autorzy:
Palanivelu, Sangeetha
Powiązania:
https://bibliotekanauki.pl/articles/396667.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
composite beam
beam
cold-formed steel
channel connectors
load
belka stalowo-betonowa
kompozyt
złącze kanałowe
obciążenie
Opis:
Steel-concrete composite structures are widely used in the current construction of bridges and multi-storey buildings. The effect of shear connectors in a cold-formed steel-composite beam was studied under flexure. The number of channel connectors in the specimen was varied and the same was compared with a specimen without shear connectors. The performance and failure of cold-formed steel-composite beams were then studied. The presence of shear connectors in the tension zone prevents the formation of cracks which are the major cause of failure in a beam subjected to bending. The load carrying capacity is greater in a composite beam and an increase in the number of channel connectors from one to five increases the load-carrying capacity by 60 % as compared to a specimen without a connector. A composite beam with five connectors is more ductile, with a ductility factor of 14. The Composite beams were also analysed using the finite element software ANSYS and were found to have good agreement with the experimental results.
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 3; 228-240
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies