Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Rysz, Andrzej" wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
A new method of cardiac sympathetic index estimation using a 1D-convolutional neural network
Autorzy:
Kołodziej, Marcin
Majkowski, Andrzej
Tarnowski, Paweł
Rak, Remigiusz Jan
Rysz, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2090741.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
epilepsy
seizure detection
seizure prediction
convolutional neural network
deep learning
ECG
HRV
cardiac sympathetic index
padaczka
wykrywanie napadu
przewidywanie napadu
splotowa sieć neuronowa
głęboka nauka
technika deep learning
EKG
wskaźnik współczulny serca
Opis:
Epilepsy is a neurological disorder that causes seizures of many different types. The article presents an analysis of heart rate variability (HRV) for epileptic seizure prediction. Considering that HRV is nonstationary, our research focused on the quantitative analysis of a Poincare plot feature, i.e. cardiac sympathetic index (CSI). It is reported that the CSI value increases before the epileptic seizure. An algorithm using a 1D-convolutional neural network (1D-CNN) was proposed for CSI estimation. The usability of this method was checked for 40 epilepsy patients. Our algorithm was compared with the method proposed by Toichi et al. The mean squared error (MSE) for testing data was 0.046 and the mean absolute percentage error (MAPE) amounted to 0.097. The 1D-CNN algorithm was also compared with regression methods. For this purpose, a classical type of neural network (MLP), as well as linear regression and SVM regression, were tested. In the study, typical artifacts occurring in ECG signals before and during an epileptic seizure were simulated. The proposed 1D-CNN algorithm estimates CSI well and is resistant to noise and artifacts in the ECG signal.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; e136921, 1--9
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new method of cardiac sympathetic index estimation using a 1D-convolutional neural network
Autorzy:
Kołodziej, Marcin
Majkowski, Andrzej
Tarnowski, Paweł
Rak, Remigiusz Jan
Rysz, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2173565.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
epilepsy
seizure detection
seizure prediction
convolutional neural network
deep learning
ECG
HRV
cardiac sympathetic index
padaczka
wykrywanie napadu
przewidywanie napadu
splotowa sieć neuronowa
głęboka nauka
technika deep learning
EKG
wskaźnik współczulny serca
Opis:
Epilepsy is a neurological disorder that causes seizures of many different types. The article presents an analysis of heart rate variability (HRV) for epileptic seizure prediction. Considering that HRV is nonstationary, our research focused on the quantitative analysis of a Poincare plot feature, i.e. cardiac sympathetic index (CSI). It is reported that the CSI value increases before the epileptic seizure. An algorithm using a 1D-convolutional neural network (1D-CNN) was proposed for CSI estimation. The usability of this method was checked for 40 epilepsy patients. Our algorithm was compared with the method proposed by Toichi et al. The mean squared error (MSE) for testing data was 0.046 and the mean absolute percentage error (MAPE) amounted to 0.097. The 1D-CNN algorithm was also compared with regression methods. For this purpose, a classical type of neural network (MLP), as well as linear regression and SVM regression, were tested. In the study, typical artifacts occurring in ECG signals before and during an epileptic seizure were simulated. The proposed 1D-CNN algorithm estimates CSI well and is resistant to noise and artifacts in the ECG signal.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; art. no. e136921
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Executive dysfunction profile in mesial temporal lobe epilepsy
Autorzy:
Olejnik, Agnieszka
Bala, Aleksandra
Dziedzic, Tomasz
Rysz, Andrzej
Marchel, Andrzej
Kunert, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/28762847.pdf
Data publikacji:
2023-11-10
Wydawca:
Fundacja Edukacji Medycznej, Promocji Zdrowia, Sztuki i Kultury Ars Medica
Tematy:
MTLE
executive functions
cognitive disorders
cognitive functioning
Opis:
The aim of the study was a comprehensive assessment of the profile of executive dysfunctions in patients with MTLE and the search for associations between the results of neuropsychological tests and individual clinical variables. We examined 25 patients with MTLE and 25 healthy controls using the Montreal Cognitive Assessment (MoCA), Color Trails Test (CTT), Tower of London (ToL), Victoria Stroop Test (VLT) and Wisconsin Card Sorting Test (WCST). We considered the possible effects of seizure frequency and lateralization of the epileptogenic zone on various aspects of cognitive functioning. MTLE group scored significantly lower than controls in MoCA (p = 0.000) and needed significantly more time (p=0.000) in CTT-2. They also had lower scores in several parts of ToL (total correct, p=0.004; additional moves, p=0.038; execution time, p=0.001; problem-solving time, p=0.003) and WCST (error responses, p=0.003; conceptual level responses, p=0.000; completed categories, p=0.007; perseverative responses, p=0.004; perseverative errors, p=0.009). There were no significant differences between the clinical and control group in VST and in other indicators of CTT, ToL and WCST. Neither the laterality of the epileptogenic focus nor the seizure frequency were significantly correlated with the results. Patients with MTLE exhibit a wide range of executive dysfunctions. Importantly, the disorders were present only in some aspects of functioning, such as: logical reasoning, planning, switching between tasks, cognitive flexibility and problem-solving, while others e.g. inhibition, remained normal. Our results constitute a significant enrichment of knowledge concerning the specificity of functioning of this group of patients which may help clinicians to introduce solutions to improve the functioning of these patients.
Źródło:
Acta Neuropsychologica; 2024, 22(1); 1-13
1730-7503
2084-4298
Pojawia się w:
Acta Neuropsychologica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the accuracy of mapping in computed tomography
Analiza dokładności odwzorowania w tomografii komputerowej
Autorzy:
Ryniewicz, Andrzej
Rysz, Konrad
Bojko, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2130926.pdf
Data publikacji:
2021
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Nowym Sączu
Tematy:
tomographic imaging
phantoms
measurements
radiological density
shape
obrazowanie tomograficzne
fantomy
pomiary
gęstość radiologiczna
kształt
Opis:
The aim of the study is to assess the accuracy of mapping the internal structure and shape of phantoms in computed tomography (CT) imaging, using reconstructive metrology and virtual measurements. The tests material is tomographic imaging of diagnostic phantoms: the head phantom used for monthly calibrations of computer tomographs and the specialized phantom for tests performed once a year. The Materialize Mimics computer program was used to measure the geometry of objects inside the phantoms and to measure the radiological density in the cross-sections of the tested patterns. It is a universal tool for assessing the accuracy of mapping in CT imaging. The results of the measurements were used to perform a complete statistical analysis. The values of standard deviations for the performed measurements did not exceed the limit value, which means that the tested tomograph meets the requirements for homogeneity of imaging and noise level specified in the Regulation of the Minister of Health. The proposed procedure is important for the target device, but can also be a tool for comparing the quality of different tomographs.
Celem pracy jest ocena dokładności odwzorowania struktury wewnętrznej i kształtu fantomów w obrazowaniu tomografią komputerową (CT), z zastosowaniem metrologii rekonstrukcyjnej i pomiarów wirtualnych. Materiałem badań jest obrazowanie tomograficzne fantomów diagnostycznych: fantomu głowy używanego do comiesięcznych kalibracji tomografów komputerowych i fantomu specjalistycznego do testów wykonywanych raz w roku. Do pomiarów geometrii obiektów znajdujących się wewnątrz fantomów oraz pomiarów gęstości radiologicznej w przekrojach badanych wzorców wykorzystano program komputerowy Materialise Mimics. Stanowi on uniwersalne narzędzie do oceny dokładności odwzorowania w obrazowaniu CT. Wyniki pomiarów wykorzystano do przeprowadzenia pełnej analizy statystycznej. Wartości odchyleń standardowych dla wykonanych pomiarów nie przekroczyły wartości granicznej, co oznacza, że badany tomograf spełnia wymogi odnośnie do jednorodności obrazowania i poziomu szumów, ujęte w Rozporządzeniu Ministra Zdrowia. Zaproponowana procedura jest istotna dla docelowego urządzenia, ale może również stanowić narzędzie do porównania jakości różnych tomografów.
Źródło:
Journal of Engineering, Energy and Informatics; 2021, 1; 53-68
2720-4162
2720-5541
Pojawia się w:
Journal of Engineering, Energy and Informatics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of carbon materials surfaces by plasma: effect of the introduced functional groups on biocompatibility and adhesion of microorganisms
Autorzy:
Duch, Joanna
Pajerski, Wojciech
Gołda-Cępa, Monika
Ochońska, Dorota
Piskorz, Witold
Brzychczy-Włoch, Monika
Rysz, Jakub
Kotarba, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1844886.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
carbon materials
plasma
biocompatibility
materiały węglowe
plazma
biokompatybilność
Źródło:
Engineering of Biomaterials; 2020, 23, 158 spec. iss.; 42
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies