Tytuł:
Profilaktyka nagłego zgonu sercowego – rola wszczepialnego kardiowertera-defibrylatora
Prevention of sudden cardiac death – the role of automatic implantable cardioverter-defibrillator
Autorzy:
Klimczak, Artur
Rosiak, Marcin
Chudzik, Michał
Powiązania:
https://bibliotekanauki.pl/articles/1032588.pdf
Data publikacji:
2010
Wydawca:
Łódzkie Towarzystwo Naukowe
Tematy:
icd
kardiowerter-defibrylator
nagły zgon sercowy
arytmia
komorowa
cardioverter-defibrillator
sudden cardiac death
ventricular
arrhythmia
Opis:
Sudden cardiac death is a significant problem in cardiac patients. The modern invasive cardiology offers important tool in fight against ventricular rhythm disturbances, which are the most frequent cause of sudden cardiac death. Automatic cardioverter-defibrillator through electric therapy (antyarrhythmia stimulation or high energy shock) interrupts the episode of life-threating ventricular arrhythmia (ventricular tachycardia or ventricular fibrillation) and therefore it protect patient from sudden cardiac death. Implantation of ICD may be performed in patients, who had the episode of ventricular tachycardia or ventricular fibrillation in the past already (within the secondary prevention of sudden cardiac death) and also in patients, which didn’t have the episode of ventricular tachycardia or ventricular fibrillation in the past but they have higher risk of sudden cardiac death in the future (within primary prevention of sudden cardiac death).
Nagły zgon sercowy (NZS) to zgon w ciągu pierwszej godziny od wystąpienia objawów. Najczęstszą przyczyną NZS są groźne komorowe zaburzenia rytmu serca. Chorzy z dysfunkcją skurczową lewej komory serca to pacjenci szczególnie zagrożeni wystąpieniem NZS. Najważniejszą metodą prewencji NZS jest terapia polegająca na wszczepieniu kardiowerteradefibrylatora (ang. implantable cardioverter-defibrillator – ICD). Działanie ICD polega na rozpoznaniu groźnej arytmii komorowej serca i przeprowadzeniu odpowiedniej terapii elektrycznej (stymulacja antyarytmiczna, bądź też wyładowania wysokoenergetyczne). Implantacja ICD może zostać wykonana u pacjentów, u których doszło w przeszłości do nagłego zatrzymania krążenia w mechanizmie częstoskurczu komorowego lub migotania komór (w ramach tzw. prewencji wtórnej) lub u pacjentów, którzy obarczeni są większym ryzykiem NZS w przyszłości (w ramach tzw. prewencji pierwotnej). Praca omawia zasady działania ICD oraz prezentuje aktualne wskazania do terapii ICD, zarówno w prewencji pierwotnej, jak i wtórnej.
Źródło:
Folia Medica Lodziensia; 2010, 37, 2; 227-242
0071-6731
Pojawia się w:
Folia Medica Lodziensia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of non-contact ultrasonic method in air to study fiber-cement corrugated boards
Autorzy:
Drelich, Radosław
Rosiak, Michał
Pakula, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2128140.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Lamb waves
cellulose fiber cement boards
non-contact ultrasonic methods
fale Lamba
płyta celulozowo-cementowa
metody ultradźwiękowe bezkontaktowe
Opis:
The fiber-cement and cellulose boards are materials commonly used in architectural engineering for exterior and interior applications such as building facades or as wall and roof covering materials. The aim of the study was to present the ultrasonic non-contact method of testing fiber-cement boards with Lamb waves and to discuss the results and limitations of the method in context of quality control of the material. The experiments were performed for the corrugated boards using a laboratory non-contact ultrasonic scanner. Lamb waves were generated in the tested materials by a transmitter excited by a chirp signal with a linearly modulated frequency. Waves transmitted through the tested material are acquired by the receiver and registered by the PC based acquisition system. The tests were done on reference plate board and the corrugated boards. As the main descriptor to assess the quality of tested boards the maximum amplitude of transmitted Lamb waves was selected. The significant role of boundary effects and frequency of waves was noticed. The obtained results have confirmed the usefulness of the applied ultrasonic method for testing macroscopic inhomogeneity of corrugated fiber-cement boards.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 2; e136740, 1--9
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of non-contact ultrasonic method in air to study fiber-cement corrugated boards
Autorzy:
Drelich, Radosław
Rosiak, Michał
Pakula, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2173608.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Lamb waves
cellulose fiber cement boards
non-contact ultrasonic methods
fale Lamba
płyta celulozowo-cementowa
metody ultradźwiękowe bezkontaktowe
Opis:
The fiber-cement and cellulose boards are materials commonly used in architectural engineering for exterior and interior applications such as building facades or as wall and roof covering materials. The aim of the study was to present the ultrasonic non-contact method of testing fiber-cement boards with Lamb waves and to discuss the results and limitations of the method in context of quality control of the material. The experiments were performed for the corrugated boards using a laboratory non-contact ultrasonic scanner. Lamb waves were generated in the tested materials by a transmitter excited by a chirp signal with a linearly modulated frequency. Waves transmitted through the tested material are acquired by the receiver and registered by the PC based acquisition system. The tests were done on reference plate board and the corrugated boards. As the main descriptor to assess the quality of tested boards the maximum amplitude of transmitted Lamb waves was selected. The significant role of boundary effects and frequency of waves was noticed. The obtained results have confirmed the usefulness of the applied ultrasonic method for testing macroscopic inhomogeneity of corrugated fiber-cement boards.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 2; art. no. e136740
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies