Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Rimeika, R." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Acousto-Optic Diffraction by Shear Horizontal Surface Acoustic Waves in 36° Rotated Y-Cut X-Propagation Lithium Tantalate
Autorzy:
Rimeika, R.
Čiplys, D.
Shur, M.
Powiązania:
https://bibliotekanauki.pl/articles/1383242.pdf
Data publikacji:
2015-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
77.65.Dq
43.35.Sx
78.20.hb
Opis:
We have investigated the acousto-optic diffraction by shear horizontal surface acoustic waves in 36° rotated Y-cut X-propagation lithium tantalate ($LiTaO_3$) crystals. The measurements were performed at the optical wavelength 633 nm of He-Ne laser and acoustic wavelengths of 50-60 μ m. The anisotropic diffraction with the light polarization rotation in the transmission mode was observed. The measured and calculated values of the light incidence angle corresponding to the strongest diffraction differed significantly. A narrow strip of a thin metal film deposited on the crystal surface drastically affected the light diffraction. We attribute these effects to the conversion processes between the shear horizontal leaky surface acoustic wave and shear horizontal surface skimming bulk wave.
Źródło:
Acta Physica Polonica A; 2015, 127, 1; 52-54
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of a GaN-Based SAW Oscillator with respect to UV Illumination and Temperature
Autorzy:
Miškinis, R.
Jokubauskis, D.
Urba, E.
Smirnov, D.
Gaidamovičiūtė, L.
Mikalauskas, K.
Sereika, A.
Rimeika, R.
Čiplys, D.
Powiązania:
https://bibliotekanauki.pl/articles/1383507.pdf
Data publikacji:
2015-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.35.+d
Opis:
Oscillation frequency of a GaN-based surface acoustic wave delay-line oscillator is investigated in the temperature range from -20°C to +38°C, with and without UV illumination. The results imply that such an oscillator may be used for temperature sensing with the resolution of up to 1 mK. On the other hand, as the frequency downshift due to UV illumination does not exhibit a significant dependence on temperature, it may be expected that such a system, when used as a UV sensor, would not require applying a correction for temperature.
Źródło:
Acta Physica Polonica A; 2015, 127, 1; 90-92
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies