Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pustelny, T." wg kryterium: Autor


Tytuł:
Surface Potential Investigations of Indium Phosphate Real Surfaces by Means of Transverse Acoustoelectric Method
Autorzy:
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1943942.pdf
Data publikacji:
1995-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
73.20.-r
43.35.+d
72.50.+b
Opis:
A method of surface potential determination in semiconductors by means of the transverse acoustoelectric effect is described. The results of theoretical analysis of the transverse acoustoelectric voltage versus surface potential and different surface electrical parameters in indium phosphate single crystals are presented. The experimental results of the surface potential investigations have been obtained after various surface treatments in InP(110) and InP(100) crystals. A strong influence of the chemical and mechanical surface treatments upon the surface potential values has been observed from the measurements. The surface InP(110) was more sensitive to different surface treatments. The changes of the surface potential values were about two times greater for InP(110) than for InP(100) samples. The surface potentials after surface treatments obtained by the acoustics method were of the range -0.08 [V] to -0.22 [V].
Źródło:
Acta Physica Polonica A; 1995, 88, 6; 1123-1132
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transverse Acoustoelectric Effect Applying in Surface Study of GaP:Te(111)
Autorzy:
Pustelny, B.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1807750.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
72.80.Ey
73.61.Ey
73.61.Jc
85.30.-z
71.20.Mq
Opis:
The possibility of using the transverse acoustoelectric phenomena in experimental investigations of near surface region in semiconductor crystals was discussed. The results of experimental investigations of GaP:Te(111) surfaces by means of the transverse acoustoelectric voltage were presented. Applying the transverse acoustoelectric voltage method, the lifetime τ of minority carrier in the near-surface region and the surface potential $V_{s}$ in GaP:Te(111) surfaces after their different technological treatments were determined.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 383-384
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary Research of an Optical Sensor for Measurements of the Blood Chamber Volume in the POLVAD Prosthesis
Autorzy:
Konieczny, G.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1418094.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Opis:
The article presents preliminary research of an optical system for using in the temporary blood volume measurements in the Polish Ventricular Assist Device (POLVAD). The basis for the proposed solution is the measurement of the light reflected from the membrane in different configurations of light emitters and light detectors. The paper is describing a proposed measurement technique, measurement circuit and preliminary static measurements results of the developed measurement system. Future development plans are stated.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 962-965
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Photonic-Crystal Fibres with Suspended Core - Numerical Analyses
Autorzy:
Pustelny, T.
Grabka, M.
Powiązania:
https://bibliotekanauki.pl/articles/1811518.pdf
Data publikacji:
2008-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.20.Ls
07.07.Df
42.79.Pw
42.81.-i
Opis:
The paper gives a short description of light guidance mechanisms of index-guided photonic-crystal fibres. The results of numerical analyses of photonic-crystal fibres with a suspended core are presented. Such fibres are planned to be applied for investigation of magneto-optic effects in gaseous media.
Źródło:
Acta Physica Polonica A; 2008, 114, 6A; A-115-A-120
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical Investigation of the Photonic-Crystal Fibres with Suspended Core
Autorzy:
Pustelny, T.
Grabka, M.
Powiązania:
https://bibliotekanauki.pl/articles/1807751.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.70.Qs
42.81.Qb
42.81.-i
42.81.Pa
07.60.Vg
Opis:
The photonic-crystal fibre with a suspended core was analyzed in order to explain possibilities of its using in investigation of electrooptic and magnetooptic effects occurring in the molecules of gas passed into air holes in the fibre. As results from numerical analysis, even 20% of electromagnetic optical energy can be propagating in the area of the air holes. The obtained results indicate the possibility of scanning the electrooptic and magnetooptic effects in photonic-crystal fibres with a suspended core in the case of considerable diminishing of the core (even below 1 μm) or in the case of light applying with its larger wavelengths.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 385-388
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of limited dynamic response of the indicator detector in a Swan-Ganz catheter on the overestimation of cardiac output measurement by means of thermodilution
Autorzy:
Gawlikowski, M.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/221141.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cardiac output measurement
thermodilution method
Swan-Ganz catheter
Opis:
Nowadays the "gold clinical standard" of hemodynamics diagnostic and cardiac output measurements is pulmonary artery catheterization by means of the Swan-Ganz catheter and thermodilution. The method itself is sensitive to numerous disturbances which cause inaccurate results. One of the well-known disadvantages of thermodilution is the overestimation of results at low values of cardiac output. This effect may concern the limited slew rate of the thermoelement mounted at the tip of the catheter. In this paper the relationship between the dynamic response of the thermoelement and the uncertainty of cardiac output measurements by means of thermodilution has been investigated theoretically and experimentally.
Źródło:
Metrology and Measurement Systems; 2012, 19, 4; 751-758
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and numerical analyses of the planar grating coupler
Autorzy:
Struk, P.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/200635.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FDTD method
grating coupler
planar waveguide
Opis:
The paper presents the results of numerical analyses of the structures of integrated optics in the form of planar waveguides made of materials with high values of the refractive index n = 2.00 and with an input-output system in the form of Bragg grating couplers. The numerical investigations were carried out by using the FDTD method (Finite Difference Time Domain method).
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2010, 58, 4; 509-512
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of actual accuracy in cardiac output measurements by means of thermodilution
Autorzy:
Gawlikowski, M.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/201601.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cardiac output
hemodynamics monitoring
thermodilution
Opis:
The essential examination in hemodynamic monitoring of the patient is the cardiac output (CO) measurement. Nowadays, in clinical practice the most popular method is indicator dilution, particularly thermodilution. It is realized by applying the Swan-Ganz catheter and observing changes of the indicator concentration. This method is sensitive to many factors and the obtained results should be treated cautiously. The paper presents theoretical and experimental studies of metrological phenomena in CO measurements by means of thermodilution, paying special attention to medical aspects of the measurements. It has been pointed out that the actual unreliability of the mentioned method reaches values from 20% to 45%, which is in opposition to the technical data of patient's monitors (typical accuracy about 5%).
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 3; 581-587
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Responses of Metal-Oxide Semiconductor Nanostructures to Nitrogen Dioxide
Autorzy:
Procek, M.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1399393.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
82.47.Rs
07.07.Df
Opis:
The paper concerns analyses of the nanostructures based on metal-oxide semiconductors, such as titanium dioxide $(TiO_2)$ and zinc oxide $(ZnO)$ exposed to nitrogen dioxide $(NO_2)$ in an atmosphere of dry and humid synthetic air. The investigations were performed at a rather low temperature amounting to 120°C. The responses of sensors differing in the morphology of their structures have been compared. Also the time of their responses were compared with each other. The paper describes theoretically changes in the effective resistance of these structures due to the interaction of the gas. The presented results are being discussed based on the analysis of physical and chemical phenomena.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 529-533
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physical Model of the Pulmonary Circulation Designed for Investigation on Cardiac Output Measurement by Means of the Thermodilution Method
Autorzy:
Gawlikowski, M.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1493354.pdf
Data publikacji:
2011-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.19.Hh
47.63.Ec
82.60.Fa
Opis:
The "gold clinical standard" of cardiac output measurements is the thermodilution method, implemented by the Swan-Ganz catheter. The unreliability of obtained results is difficult to estimate experimentally, due to the lack of reference methods or the risk of serious interferences in the measured object. Moreover, the pulsating blood flow produced by the heart is difficult to measure. Therefore it is advisable to develop the physical model of the pulmonary circulation, designed to investigate the accuracy of cardiac output measurements by means of the thermodilution method.
Źródło:
Acta Physica Polonica A; 2011, 120, 4; 798-802
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of Some Kinetic Parameters of Fast Surface States in Silicon Single Crystals by Means of Surface Acoustic Wave Method
Autorzy:
Pustelny, T.
Opilski, A.
Pustelny, B.
Powiązania:
https://bibliotekanauki.pl/articles/1811565.pdf
Data publikacji:
2008-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
72.50.+b
77.65.Dq
73.50.Rb
73.20.-r
73.61.-r
Opis:
The paper presents the acoustic method for determining some parameters of fast surface states in semiconductors. This method uses the interactions of the phonon-electron type for determining both the effective carrier lifetime τ influenced by the fast surface energetic states and the velocity g of the carrier trapped by the surface states. Some experimental results of the parameters τ and g in near-surface region of real Si(111) samples for their various surface treatments, obtained by the offered method, are presented.
Źródło:
Acta Physica Polonica A; 2008, 114, 6A; A-183-A-190
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical model for analysis of spatial characteristics of ultrasound heads
Autorzy:
Szpakowski, A.
Pustelny, T.
Ochocki, M.
Powiązania:
https://bibliotekanauki.pl/articles/332278.pdf
Data publikacji:
2003
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
ultrasound head
acoustics
Opis:
The paper presents the physical base of the numerical system for analysis and modelling acoustic fields generated by an acoustic head of arbitrary construction. The elaborated system allows to analyse the sending-receiving multielements ultrasound heads. In the paper modeling of the acoustic system as the linear one was proposed. Numerical model, its implementation and preliminary results was presented.
Źródło:
Hydroacoustics; 2003, 6; 177-182
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical Sensor for Measurements of the Blood Chamber Volume in the POLVAD Prosthesis - Static Measurements
Autorzy:
Konieczny, G.
Pustelny, T.
Marczyński, P.
Powiązania:
https://bibliotekanauki.pl/articles/1399376.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.79.-e
42.81.-i
07.07.Df
47.63.Cb
Opis:
The paper presents results of extended static measurements of a newly developed optical system for temporary blood chamber volume measurements in the Polish Ventricular Assist Device. The paper additionally introduces a modified measurement stand and improvements of the measurements. Exemplary results acquired with principal components analysis are shown and future development plans of an optical measurement system are stated.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 479-482
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on Pattern Recognition Applied for Volume Estimation of Blood Chamber with Matrix of Optical Sensors
Autorzy:
Marczyński, P.
Konieczny, G.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1399384.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.30.Sy
47.54.-r
43.60.Lq
Opis:
The following article describes research on possibility of using pattern recognition algorithms in the optical measurement system for estimation of the blood chamber volume in the Polish Ventricular Assist Device (POLVAD). The optical system is being developed at the Department of Optoelectronics, Silesian University of Technology, Poland. Data analysis methods include a feature subset selection algorithm involving principal components analysis and objective function as quality criterion. The analysis takes into account 17 patterns reflecting particular volumes. The k-nearest neighbours method is used as pattern classifier. The pattern recognition system was initially designed for an array of gas sensors and this paper describes its further development.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 498-501
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of the Rotational Speed of the Polymer SU8 on the Thickness of the Waveguide Layer
Autorzy:
Gut, K.
Pustelny, T.
Nabagło, D.
Powiązania:
https://bibliotekanauki.pl/articles/1506779.pdf
Data publikacji:
2010-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.25.Hz
42.25.-p
42.70.-a
42.82.-m
42.82.Et
68.35.Ct
Opis:
The paper presents results of investigations concerning the measurement of the refractive index and thickness of planar waveguide structures, obtained by the photopolymerization of polymer SU8. Sodium-calcium glass was used as the substrate. As the knowledge of the quoted parameters is from the viewpoint of the structure of various types of optical sensors of crucial importance, the way of their determination has been presented. The paper deals also with the method of constructing planar polymer waveguides, taking into account problems connected with their adhesion to glass substrates.
Źródło:
Acta Physica Polonica A; 2010, 118, 6; 1136-1138
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies