Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pustelny, B." wg kryterium: Autor


Wyświetlanie 1-13 z 13
Tytuł:
Transverse Acoustoelectric Effect Applying in Surface Study of GaP:Te(111)
Autorzy:
Pustelny, B.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1807750.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
72.80.Ey
73.61.Ey
73.61.Jc
85.30.-z
71.20.Mq
Opis:
The possibility of using the transverse acoustoelectric phenomena in experimental investigations of near surface region in semiconductor crystals was discussed. The results of experimental investigations of GaP:Te(111) surfaces by means of the transverse acoustoelectric voltage were presented. Applying the transverse acoustoelectric voltage method, the lifetime τ of minority carrier in the near-surface region and the surface potential $V_{s}$ in GaP:Te(111) surfaces after their different technological treatments were determined.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 383-384
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termofalowa metoda pomiaru dyfuzyjności cieplnej
Thermal wave method for the determination of thermal diffusivity
Autorzy:
Mazur, J.
Pustelny, B.
Powiązania:
https://bibliotekanauki.pl/articles/257034.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
dyfuzyjność cieplna
właściwości cieplne
metoda pomiarowa
fala termiczna
fotoakustyka
radiometria w podczerwieni
thermal diffusivity
thermal properties
measurement methods
thermal waves
photoacoustics
infrared radiometry
Opis:
W niniejszej pracy przedstawiono termofalową metodę pomiaru dyfuzyjności cieplnej z detekcją fotoakustyczną i radiometryczną. Opracowana procedura bazuje na pomiarze przesunięcia fazowego między sygnałami rejestrowanymi przez detektor a sygnałem sterującym modulacją źródła światła. Zastosowanie materiału referencyjnego pozwoliło na wyeliminowanie wpływu komponentów układu pomiarowego na rejestrowane przesunięcie fazowe.
This paper presents a proposition of the thermal wave method of measuring the thermal diffusivity by means of photoacoustic and infrared radiometry detection. The described procedure is based on the determination of the phase-shift between the light source and the registered signal. A reference material is used for the elimination of the measurement set-up contribution to phase.
Źródło:
Problemy Eksploatacji; 2008, 3; 177-187
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of Some Kinetic Parameters of Fast Surface States in Silicon Single Crystals by Means of Surface Acoustic Wave Method
Autorzy:
Pustelny, T.
Opilski, A.
Pustelny, B.
Powiązania:
https://bibliotekanauki.pl/articles/1811565.pdf
Data publikacji:
2008-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
72.50.+b
77.65.Dq
73.50.Rb
73.20.-r
73.61.-r
Opis:
The paper presents the acoustic method for determining some parameters of fast surface states in semiconductors. This method uses the interactions of the phonon-electron type for determining both the effective carrier lifetime τ influenced by the fast surface energetic states and the velocity g of the carrier trapped by the surface states. Some experimental results of the parameters τ and g in near-surface region of real Si(111) samples for their various surface treatments, obtained by the offered method, are presented.
Źródło:
Acta Physica Polonica A; 2008, 114, 6A; A-183-A-190
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zinc Oxide Semiconductor for Photonics Structures Applications
Autorzy:
Struk, P.
Pustelny, T.
Pustelny, B.
Gołaszewska, K.
Kamińska, E.
Piotrowska, A.
Borysiewicz, M.
Ekielski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1506857.pdf
Data publikacji:
2010-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.25.Hz
42.70.-a
42.82.-m
68.35.Ct
Opis:
The paper presents investigations concerning the analysis of photonic structures with grating couplers. In the paper basic theoretically information on photonic structures with grating couplers is presented. The results of numerical investigations on photonic structures with grating couplers are discussed, too. Investigations show an essential influence of the geometrical parameters of grating couplers on the effectiveness of the input and output of optic power into and out of this photonic structure. In the paper the selected results of experimental realizations of photonic structures with grating couplers based on zinc oxide ZnO are presented.
Źródło:
Acta Physica Polonica A; 2010, 118, 6; 1242-1245
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Clinical Studies of Rheocardiography Application to Hemodynamic Monitoring of Patients with Dilated Cardiomyopathy
Autorzy:
Przywara-Chowaniec, B.
Poloński, L.
Gawlikowski, M.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1807749.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
47.63.Cb
87.19.U-
Opis:
Impedance cardiography is a non-invasive, cheap and easy to use method of long term hemodynamic monitoring. Nowadays this method is perceived as an alternative for invasive monitoring of the patients. The goal of the presented papers was to compare the results of rheocardiography with reference invasive monitoring.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 380-382
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Anatomic Structure of Pulmonary Arteries as a Source of Unreliability in Thermodilution Cardiac Output Measurement
Autorzy:
Gawlikowski, M.
Pustelny, T.
Przywara-Chowaniec, B.
Struk, P.
Powiązania:
https://bibliotekanauki.pl/articles/1811516.pdf
Data publikacji:
2008-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
47.63.Cb
07.05.Tp
87.19.Uv
Opis:
One of the most fundamental examination in intensive care medicine is cardiac output measurement, realized by pulmonary artery catherization. The thermodilution cardiac output estimation method is not resistant to various kinds of disturbances, which significantly decreases its sensitivity and specificity. The paper depicts investigations related to analysis of presumable new source of unreliability - asymmetric blood flow through pulmonary vessels. The investigations consisted of two phases: clinical examination (to obtain anatomical data) and computer modeling (to simulate the flow symmetry).
Źródło:
Acta Physica Polonica A; 2008, 114, 6A; A-81-A-89
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical Analysis of Sensitivity of SAW Structure to the Effect of Toxic Gases
Autorzy:
Hejczyk, T.
Pustelny, T.
Wszołek, B.
Jakubik, W.
Maciak, E.
Powiązania:
https://bibliotekanauki.pl/articles/177695.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
surface acoustics wave SAW
SAW
Ingebrigtsen’s formula
gas diffusion equations
gaseous acoustic sensors
numerical analyses of SAW structures
Opis:
The paper presents the results of numerical analysis of the SAW gas sensor in the steady and non-steady states. The effect of SAW velocity changes vs surface electrical conductivity of the sensing layer is predicted. The conductivity of the porous sensing layer above the piezoelectric waveguide depends on the profile of the diffused gas molecule concentration inside the layer. The Knudsen’s model of gas diffusion was used. Numerical results for the effect of gas CH4 on layers: WO3, TiO2, NiO, SnO2 in the steady state and CH4 in the non-steady state in recovery step in the WO3 sensing layer have been shown. The main aim of the investigation was to study thin film interaction with target gases in the SAW sensor configuration based on simple reaction-diffusion equation. The results of the numerical analysis allow to select the sensor design conditions, including the morphology of the sensor layer, its thickness, operating temperature, and layer type. The numerical results basing on the code elaborated numerical system (written in Python language), were analysed. The theoretical results were verified and confirmed experimentally.
Źródło:
Archives of Acoustics; 2016, 41, 4; 747-755
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Theoretical and model analysis of the unreliability of cardiac output measurement by means of the thermodilution method
Autorzy:
Gawlikowski, M.
Pustelny, T.
Przywara-Chowaniec, B.
Nowak-Gawlikowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/200095.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cardiac output measurement
thermodilution method
Opis:
Thermodilution is the clinically most often applied method of cardiac output measurements. This method is based on thermal indicator (iced isotonic salt solution) variation measurements by a Swan-Ganz catheter located inside the pulmonary artery. The unreliability of thermodilution should be estimated theoretically because of the lack of references. In this paper an attempt has been made to estimate theoretically the unreliability of thermodilution cardiac output measurements.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 435-439
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model Study of Cardiac Output Measurement by Thermodilution in Thermal Instability
Autorzy:
Gawlikowski, M.
Pustelny, T.
Przywara-Chowaniec, B.
Nowak-Gawlikowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/1506760.pdf
Data publikacji:
2010-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
47.63.Cb
87.19.U-
Opis:
Cardiac output is one of the most valuable hemodynamic parameter. It is measured commonly with intravascular pressures by pulmonary artery catheterization technique. The cardiac output itself is measured by dilution of thermal marker method (thermodilution), which is not resistant for various disturbances. In this paper the influence of blood temperature on metrological properties of thermal dilution method was described.
Źródło:
Acta Physica Polonica A; 2010, 118, 6; 1124-1126
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evolution of the diffraction pattern during the transition from the near-field toward the far-field region
Autorzy:
Grabka, M.
Pustelny, S.
Wajnchold, B.
Gawlik, W.
Mergo, P.
Powiązania:
https://bibliotekanauki.pl/articles/200137.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wave optics
diffraction of light
near-field diffraction
microstructured optical fibres
photonic crystal fibers
Opis:
In the paper we experimentally and theoretically analyze diffraction of light propagating through a microstructured optical fiber on the fiber end face. In the measurements the diffracting light is spatially inhomogeneous and the diffracting object is a solid-state core with a triangular shape. Application of optical system enables detailed experimental investigations of evolution diffraction pattern in the near-field region, in particular, rotation of the observed structure while departing from the fiber end. The experimental results are confirmed with theoretical simulations based on the theory of the Fresnel diffraction.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 389-393
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena przydatności reokardiografii impedancyjnej w monitorowaniu stanu hemodynamicznego pacjentów z ciężkim uszkodzeniem lewej komory
Evaluation of impedance rheocardiography suitability in hemodynamic monitoring of patients with serious left ventricle injury
Autorzy:
Przywara-Chowaniec, B.
Poloński, L.
Gawlikowski, M.
Pustelny, T.
Nowak-Gawlikowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/261274.pdf
Data publikacji:
2009
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
reografia impedancyjna
reokardiografia
monitorowanie hemodynamiczne
impedance rheography
rheocardiography
hemodynamic monitoring
Opis:
Reokardiografia impedancyjna, będąca nieinwazyjną metodą oceny stanu hemodynamicznego pacjenta, zdobywa w ostatnich latach uznanie jako cenne uzupełnienie badań echokardiograficznych i monitorowania inwazyjnego. W prezento- wanej pracy porównano wartości wybranych parametrów hemodynamicznych monitorowanych metodą reokardiografii z referencyjną metodą termodylucji. Badania przeprowadzono w czasie wstępnej diagnostyki przed zabiegiem transplantacji serca w grupie 22 chorych, hospitalizowanych z powodu niewydolności krążenia w przebiegu kardiomiopatii rozstrzeniowej.
The rheocardiography is a non-invasive method of patient’s hemodynamic state assessment. Recently it has been recognized as a valuable complement of echocardiography and invasive monitoring. In this paper the selected hemodynamic parameters measured by rheocardiography were compared with reference (thermodilution). The examinations were as a pre-diagnostic to heart transplantation (HTX) performed on 22 patients hospitalized because of circulatory insufficiency in course of dilated cardiomyopathy.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2009, 15, 4; 362-364
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and Theoretical Study of Light Propagation in Suspended-Core Optical Fiber
Autorzy:
Grabka, M.
Wajnchold, B.
Pustelny, S.
Gawlik, W.
Skorupski, K.
Mergo, P.
Powiązania:
https://bibliotekanauki.pl/articles/1506776.pdf
Data publikacji:
2010-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.70.Qs
42.81.Qb
42.81.-i
42.81.Pa
07.60.Vg
Opis:
We analyze coupling and propagation of light through a suspended-core microstructured optical fiber. It is experimentally demonstrated that light-coupling efficiency and mode distribution strongly depend on relative position of the fiber's core and a light beam and light polarization. The experimental results are supported with numerical simulations. The developed numerical model confirmed all the observed dependences.
Źródło:
Acta Physica Polonica A; 2010, 118, 6; 1127-1132
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Properties of GaN Nanocolumns Grown by Plasma - Assisted MBE on Si (111) Substrates
Autorzy:
Zytkiewicz, Z.
Dluzewski, P.
Borysiuk, J.
Sobanska, M.
Klosek, K.
Witkowski, B.
Setkiewicz, M.
Pustelny, T.
Powiązania:
https://bibliotekanauki.pl/articles/1492480.pdf
Data publikacji:
2011-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.15.Hi
81.05.Dz
61.46.Km
Opis:
We report on growth of GaN nanocolumns by plasma assisted MBE on (111) silicon substrates and on their characterization. The nanocolumns nucleate on the substrate spontaneously without use of any catalyst, probably by the Volmer-Weber mechanism. Transmission electron microscopy analysis shows high crystalline quality of GaN nanocolumns and their good alignment with the c-axis being perpendicular to the substrate. Preliminary results on use of GaN nanocolumns in gas sensor devices are presented.
Źródło:
Acta Physica Polonica A; 2011, 120, 6A; A-015-A-016
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies