Krótki przegląd badań współczynnika filtracji gruntów
Brief overview of soil hydraulic conductivity testing methods
Autorzy:
Popielski, Paweł
Dąbska, Agnieszka
Kaczmarek, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2087057.pdf
Data publikacji:
2022
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
przewodność hydrauliczna
klasyfikacja metod badawczych
gradient hydrauliczny
typ gleby
hydraulic conductivity
classification of test methods
hydraulic gradient
soil type
Opis:
Many research methods enable the determination of the permeability properties of the soil. These methods differ, inter alia, in accuracy, complexity, application ranges, and technical conditions. The choice of a particular method is often dictated by the purpose of determining the hydraulic conductivity. The review of the most popular methods facilitates the optimization of the selection, as well as the application of mutually verifying methods or using them at different stages of the research. The article summarizes selected methods of determining the soil hydraulic conductivity from common research groups, including correlation, laboratory, and field methods, as well as less frequently used geophysical methods.
Źródło:
Przegląd Geologiczny; 2022, 70, 5; 410--416
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problematyka badań współczynnika filtracji w aparacie trójosiowego ściskania
On the issue of hydraulic conductivity tests using a triaxial compressi apparatus
Autorzy:
Kaczmarek, Łukasz
Dąbska, Agnieszka
Popielski, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2087059.pdf
Data publikacji:
2022
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
przewodność hydrauliczna
przepływ wody
gradient hydrauliczny
stan naprężenia
hydraulic conductivity
water flow
hydraulic gradient
stress state
Opis:
Laboratory tests, which enable determination of the permeability properties of soil, are distinguished by the accuracy and relatively shorttesttime. Moreover, laboratory methods using a triaxial compression apparatus expand capability for tests with a different filtration regime and a spatial stress state applied on the analysed material. Such flexibility of research procedures allows for a number of scientific and engineering applications. The article outlines the construction of the triaxial apparatus system dedicated to filtration tests, their procedure, and important interpretation aspects.
Źródło:
Przegląd Geologiczny; 2022, 70, 5; 417--423
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Role of geophysical surveys in the identification of water escape zones from retention lakes: a case study on a selected object in Upper Silesia
Autorzy:
Mieszkowski, Radosław
Wójcik, Emilia
Kozłowski, Mikołaj
Popielski, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2025248.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ground penetrating radar (GPR) method
electrical resistivity tomography (ERT) method
retention lake
water reservoir
Opis:
The main scientific goal of this work is the presentation of the role of selected geophysical methods (Ground-Penetrating Radar GPR and Electrical Resistivity Tomography ERT) to identify water escape zones from retention reservoirs. The paper proposes a methodology of geophysical investigations for the identification of water escape zones from a retention fresh water lake (low mineralised water). The study was performed in a lake reservoir in Upper Silesia. Since a number of years the administrators of the lake have observed a decreasing water level, a phenomenon that is not related to the exploitation of the object. The analysed retention lake has a maximal depth between 6 and 10 m, depending on the season. It is located on Triassic carbonate rocks of the Muschelkalk facies. Geophysical surveys included measurements on the water surface using ground penetration radar (GPR) and electrical resistivity tomography (ERT) methods. The measurements were performed from watercrafts made of non-metal materials. The prospection reached a depth of about 1 to 5 m below the reservoir bottom. Due to large difficulties of conducting investigations in the lake, a fragment with an area of about 5,300 m2, where service activities and sealing works were already commenced, was selected for the geophysical survey. The scope of this work was: (1) field geophysical research (Ground-Penetrating Radar GPR and Electrical Resistivity Tomography ERT with geodesic service), (2) processing of the obtained geophysical research results, (3) modelling of GPR and ERT anomalies on a fractured water reservoir bottom, and (4) interpretation of the obtained results based on the modelled geophysical anomalies. The geophysical surveys allowed for distinguishing a zone with anomalous physical parameters in the area of the analysed part of the retention lake. ERT surveys have shown that the water escape zone from the reservoir was characterised by significantly decreased electrical resistivities. Diffraction hyperboles and a zone of wave attenuation were observed on the GPR images in the lake bottom within the water escape zone indicating cracks in the bottom of the water reservoir. The proposed methodology of geophysical surveys seems effective in solving untypical issues such as measurements on the water surface.
Źródło:
Studia Quaternaria; 2018, 35; 121-129
1641-5558
2300-0384
Pojawia się w:
Studia Quaternaria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Settlement of a historic building due to seepage-induced soil deformation
Osiadanie zabytkowego budynku w wyniku deformacji filtracyjnych gruntu
Autorzy:
Popielski, Paweł
Bednarz, Bartosz
Majewski, Tomasz
Niedostatkiewicz, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/27312076.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
podłoże budowlane
filtracja
grunt
osiadanie budynku
deformacja filtracyjna
budynek zabytkowy
building subsoil
seepage
ground
building settlement
seepage-induced deformation
historic building
Opis:
The research paper reviews issues associated with the impact of groundwater flow on soil characteristics and parameters, hence, the entire structure of a building set on it. Water seepage through the ground, building subsoil or structural elements of buildings made of soil affects the soil skeleton and may lead to changes in the arrangement of individual grains relative to each other, i.e., a modified soil structure. Soil solid phase (soil skeleton) deformations resulting from seepage forces are called seepage-induced deformations. The article characterizes typical seepage-induced deformations and specifies a criterion defining the beginning of the phenomenon. The case study involved using data on cracks and deformations in a historic building, as well as water seepage in its subsoil. Seepage was analysed, and zones where the seepage process initiation criterion was exceeded, were determined based on subsoil water level monitoring data. The determined zones coincide with the location of building cracks and scratches and confirm the possible cause behind building damage.
W artykule dokonano przeglądu zagadnień związanych z wpływem przepływu wód gruntowych na właściwości i parametry gruntu, a tym samym na całą konstrukcję posadowionego na nim budynku. Filtracja wody przez grunt, podłoże budowlane lub elementy konstrukcyjne budowli wykonanych z gruntu oddziałuje na szkielet gruntu i może prowadzić do zmian w układzie poszczególnych ziaren względem siebie, czyli do modyfikacji jego struktury. Odkształcenia szkieletu gruntowego wynikające z działania sił filtracji nazywane są deformacjami filtracyjnymi. W artykule scharakteryzowano typowe deformacje wywołane filtracją wody w gruncie oraz podano kryterium określające moment pojawiania się danego zjawiska. W studium przypadku wykorzystano dane dotyczące spękań i odkształceń w zabytkowym budynku oraz filtracji wody w jego podłożu. Na podstawie danych z monitoringu poziomu wody gruntowej przeanalizowano przepływ wód podziemnych i wyznaczono strefy, w których przekroczone zostało kryterium inicjacji procesu sufozji. Wyznaczone strefy pokrywają się z lokalizacją pęknięć i zarysowań budynku i potwierdzają możliwą przyczynę jego uszkodzenia.
Źródło:
Archives of Civil Engineering; 2023, 69, 2; 65--82
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies