Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Polak, W." wg kryterium: Autor


Tytuł:
Single Proton Hit Facility at the IFJ PAN in Cracow
Autorzy:
Polak, W.
Lekki, J.
Veselov, O.
Stachura, Z.
Styczeń, J.
Powiązania:
https://bibliotekanauki.pl/articles/2044772.pdf
Data publikacji:
2006-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.50.Gi
87.50.-a
Opis:
This work presents the final development stage and optimization results of the single proton hit facility in Cracow. The setup parameters: proton beam energy 2 MeV, hit resolution 30μm, intensity ≈1000 proton/s, proton registration efficiency 100%, blanking efficiency 99.8%. On-line observation allows targeting cells inside a Petri dish mounted at a 3D precise moving stage. To target a particular cell a semiautomatic cell visualization and recognition system is used.
Źródło:
Acta Physica Polonica A; 2006, 109, 3; 417-420
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing the efficiency of the Si3N4 membranes for charged particles registration
Autorzy:
Polak, W.
Lekki, J.
Gryboś, J.
Hajduk, R.
Cholewa, M.
Kukharenko, O.
Stachura, Z.
Powiązania:
https://bibliotekanauki.pl/articles/148584.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
Si3N4
membrane
detection
secondary electrons
CsI
Opis:
Testing Si3N4 membrane windows is a preliminary research for the single-ion-single-cell irradiating programme prepared at the Cracow nuclear microprobe facility. The present investigation is concerned with finding a method to register every single particle of the microprobe beam when passing through a membrane to the atmosphere. The 200 nm thick membranes covered with different layers were investigated. The alpha particles, after passing the membrane window, were registered by a particle detector. Secondary electrons ejected from the membrane by alpha particles were registered by a channeltron. The channeltron signals were collected in coincidence with the silicon detector signals. The detection efficiency is the ratio of the fast coincident channeltron signal number to the total number of the silicon detector signals. The results of investigation of the membranes with different coverages are reported in the present work.
Źródło:
Nukleonika; 2003, 48, 1; 25-29
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations of the influence of engine thermal state on the fuel consumption of passenger vehicles
Autorzy:
Adamski, W.
Polak, S.
Powiązania:
https://bibliotekanauki.pl/articles/133704.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
passenger vehicle
fuel consumption
engine thermal state
samochód osobowy
zużycie paliwa
stan cieplny silnika
Opis:
The paper presents the results of investigations of the fuel consumption of two vehicles performed for non-stabilized engine temperature in the start and warm up phases. The measurements were performed in a wide range of ambient temperatures from –18°C to +25°C. In order to obtain such conditions the tests were carried out in a climate chamber.
Źródło:
Combustion Engines; 2017, 56, 2; 49-52
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wspomagana komputerowo lokalizacja wyładowań niezupełnych w transformatorze energetycznym
Computer aided location of PD sources in power transformers
Autorzy:
Polak, F.
Sikorski, W.
Powiązania:
https://bibliotekanauki.pl/articles/377265.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
wyładowania niezupełne
lokalizacja źródeł wyładowań niezupełnych
transformator energetyczny
Opis:
W artykule poruszono problematykę wspomaganej komputerowo, automatycznej lokalizacji źródeł wyładowań niezupełnych występujących w układzie izolacyjnym transformatora energetycznego. Główna część artykułu przedstawia opis przyjętych metod badawczych oraz wyniki testów przeprowadzonych na modelu kadzi transformatora w Laboratorium Wysokich Napięć Politechniki Poznańskiej. W eksperymencie do lokalizowania defektów stosowano standardową technikę triangulacyjną oraz jej zmodyfikowaną wersję wykorzystującą pojęcie psuedoczasów, które zostało zaczerpnięte z techniki GPS. Głównym celem przeprowadzonych badań była analiza porównawcza dokładności lokalizacji źródeł wybranymi metodami. Zastosowane algorytmy lokalizacji oraz metody cyfrowego przetwarzania sygnałów zaimplementowano w środowisku programowania Lab VIEW.
In this paper the phenomenon of partial discharges, standard auscultatory and triangulation methods of PD sources localization were shortly explained. The main part of paper contains results of research conducted on a power transformer tank model in the high voltage laboratory of Poznan University of Technology. A triangulation method with its extension using the GPS technique was used in the experiment. In order to improve signal processing an advanced program was written in the LabVIEW environment. The measurement system and the method of time of arrival estimation (TOA) were described. For every method used in the survey, waveforms with marked beginnings of the AE signals and error graphs were shown. On the basis of the results an evaluation of accuracy of each methods was prepared.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 74; 171-179
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototypowanie anten UHF przy pomocy programów symulacyjno-obliczeniowych
Prototyping of uhf antennas using simulation software
Autorzy:
Polak, F.
Sikorski, W.
Siodła, K.
Powiązania:
https://bibliotekanauki.pl/articles/377250.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
wyładowania niezupełne
antena UHF
prototypowanie anten
symulacje
Opis:
Metoda ultra wysokich częstotliwości (ang. UHF – Ultra High Frequency) znajduje coraz szersze zastosowanie w diagnostyce transformatorów energetycznych. Wykorzystując sondy (anteny) montowane wewnątrz kadzi transformatora możliwa jest detekcja wyładowań niezupełnych pojawiających się w miejscach występowania defektów wysokonapięciowego układu izolacyjnego. Sondy takie muszą być odpowiednio zaprojektowane i zoptymalizowane z uwzględnieniem wielu czynników, takich jak np. pasmo częstotliwościowe, kierunkowość, czy konstrukcja geometryczna. W pracy zaprezentowane zostały parametry dwóch typów anten (mikropaskowej oraz dyskowostożkowej) uzyskanych na drodze symulacji. Na podstawie obliczeń i symulacji powstaną prototypy anten, które docelowo mają znaleźć zastosowanie w układzie służącym do lokalizacji wyładowań niezupełnych wewnątrz transformatorów energetycznych.
The method of ultra high frequency is being increasingly applied in the power transformers diagnostics. Using the probe (antenna) mounted inside the transformer tank it is possible to detect partial discharges occurring in defects of high–voltage insulation system. Such probes must be designed and optimized on several factors, such as frequency band, directivity, or the geometrical design etc. This paper presents parameters of the two types of antennas (discone and microstrip patch) obtained through simulation. Calculations and simulations results will provide basis to rise the prototypes of the antennas, which will eventually find application in the measurement system used for localisation of partial discharges inside power transformers.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 85; 85-93
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lokalizacja źródeł wyładowań niezupełnych przy użyciu matrycy przetworników
Partial discharge source localization using sensor array
Autorzy:
Polak, F.
Sikorski, W.
Siodła, K.
Powiązania:
https://bibliotekanauki.pl/articles/378075.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
wyładowania niezupełne
lokalizacja źródeł sygnałów
matryca przetworników
estymacja kierunku nadejścia sygnału (DOA)
DOA
algorytm Multiple Signal Classification
Opis:
Artykuł dotyczy problematyki lokalizacji źródeł wyładowań niezupełnych (wnz) przy użyciu techniki matryc przetworników emisji akustycznej oraz wysokorozdzielczej techniki estymacji kierunku nadejścia sygnału. W pracy, oprócz założeń teoretycznych obu technik, przedstawiono wyniki symulacji, w których do rejestracji sygnałów emisji akustycznej generowanych przez defekty układu izolacyjnego transformatora energetycznego, zastosowano liniową matrycę przetworników (ang. ULA - Uniform Linear Array). Z kolei do estymacji kierunku nadejścia sygnałów akustycznych, które propagują się od defektu generującego wyładowania do zainstalowanej na kadzi transformatora matrycy przetworników, wybrano algorytm Multiple Signal Classification (MUSIC). Dzięki możliwości lokalizacji wyładowań wieloźródłowych (nawet przy bardzo niskim stosunku sygnału użytecznego od szumu), przyjęte rozwiązanie wykazuje przewagę nad technikami konwencjonalnymi.
This paper concerns the issue of partial discharges (PD) sources location using acoustic emission transducer arrays technique and the high resolution direction of arrival estimation technology. In addition to the theoretical assumptions of both techniques, the simulation result, in which an uniform linear array (ULA) was used for registration of the acoustic emission signals generated by defects in power transformer insulation system, were shown. To estimate the direction of arrival (DOA) of acoustic signals, that propagate from the discharge-generating defect to the transducer array installed on transformer tank, Multiple Signal Classification (MUSIC) algorithm was chosen. With the ability to locate multisource discharges (even at very low signal to noise ratio - SNR), the adopted solution has advantages over conventional techniques.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 78; 157-166
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototype measurement system for localization of partial discharges sources – microphone array
Autorzy:
Polak, F.
Sikorski, W.
Siodła, K.
Powiązania:
https://bibliotekanauki.pl/articles/97228.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
partial discharges (PDs)
PD localization
sensor array
microphone array
beamforming
direction-of-arrival (DOA)
Opis:
This paper presents a prototype measurement system, that will be used for localization of acoustic emission sources originating from partial discharges (PD). It is based on sensor arrays technology and direction of arrival estimation algorithms. Acoustic signals will be received with a universal linear array (ULA) of sensors, wherein the sensory elements are microphones operating in the audible frequency range. For the estimation of the direction of arrival of these signals conventional beamforming algorithm is used which has also been described theoretically. Ultimately, the system will be used to determine the direction of arrival of the acoustic signal generated by the insulation defect, which is corona discharge.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 209-219
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototyping of UHF antennas using simulation software
Autorzy:
Polak, F.
Sikorski, W.
Siodła, K.
Powiązania:
https://bibliotekanauki.pl/articles/97315.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
partial discharges
UHF antenna
antenna design
simulations
Opis:
The method of ultra high frequency is being increasingly applied in the power transformer diagnostics. Using the probe (antenna) mounted inside the transformer tank it is possible to detect partial discharges occurring in defects of high–voltage insulation system. Such probes must be designed and optimized on several factors, such as frequency band, directivity, or the geometrical design etc. This paper presents parameters of two types of antennas (discone and microstrip patch) obtained through simulation. Calculations and simulations results will provide basis to comnstruct the prototypes of the antennas, which will eventually find application in the measurement system used for localisation of partial discharges inside power transformers.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 168-176
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Localisation of partial discharges sources using acoustic transducers arrays
Autorzy:
Polak, F.
Sikorski, W.
Siodła, K.
Powiązania:
https://bibliotekanauki.pl/articles/97543.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
partial discharge
Signal Source Localisation
Transducer Array
Direction of Arrival (DOA) Estimation
music
Opis:
This paper concerns the issue of the partial discharge (PD) sources location using acoustic emission transducer arrays technique and the high resolution direction of arrival estimation technology. In addition to the theoretical assumptions of both techniques, the simulation result, in which an uniform linear array (ULA) was used for registration of the acoustic emission signals generated by defects in power transformer insulation system were shown. To estimate the direction of arrival (DOA) of acoustic signals, that propagate from the discharge-generating defect to the transducer array installed on transformer tank, Multiple Signal Classification (MUSIC) algorithm was chosen. With the ability to locate multisource discharges (even at very low signal-to-noise ratio - SNR), the adopted solution has advantages over conventional techniques.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 237-245
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototypowy układ pomiarowy do lokalizacji źródeł emisji akustycznej - matryca mikrofonów
Prototype measurement system for localisation of partial discharges sources – microphone array
Autorzy:
Polak, F.
Sikorski, W.
Siodła, K.
Powiązania:
https://bibliotekanauki.pl/articles/376647.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
wyładowania niezupełne
lokalizacja źródeł sygnałów
matryca sensorowa
estymacja kierunku nadejścia sygnału (DOA)
kształtowanie wiązki
beamforming
Opis:
W pracy zaprezentowany został prototypowy układ pomiarowy służący do lokalizacji źródeł sygnałów dźwiękowych, pochodzących od wyładowań niezupełnych, opierający się na technologii matryc sensorowych oraz algorytmów estymacji kierunku nadejścia sygnałów. Sygnały akustyczne odbierane są przy pomocy liniowej matrycy sensorów, w której elementami sensorycznymi są mikrofony pracujące w zakresie częstotliwości słyszalnych. Do estymacji kierunku nadejścia tych sygnałów użyto klasycznego algorytmu kształtowania wiązki, którego założenia teoretyczne zawarto w pracy. Docelowo układ będzie służył do określania lokalizacji źródła sygnałów akustycznych generowanych przez wyładowanie ulotowe.
This paper presents a prototype measurement system, that will be used for localisation of acoustic emission sources. It is based on sensor arrays technology and direction of arrival estimation algorithms. Acoustic signals will be received with a universal linear array (ULA) of sensors, wherein the sensory elements are microphones operating in the audible frequency range. For the estimation of the direction of arrival of these signals conventional beamforming algorithm is used which has also been described theoretically. Ultimately, the system will be used to determine the direction of arrival of the acoustic signal generated by the insulation defect, which is corona discharge.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 84; 207-214
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Częstość występowania zmian urazowych w badaniu TK – politrauma
The incidence of traumatic lesions in the CT – politrauma study
Autorzy:
Wojtasik, A.
Guz, W.
Polak, H.
Powiązania:
https://bibliotekanauki.pl/articles/112307.pdf
Data publikacji:
2018
Wydawca:
Indygo Zahir Media
Tematy:
uraz wielonarządowy
TK-politrauma
zmiany urazowe
tomografia komputerowa
multiorgan injury
CT- polytrauma
traumatic changes
computer tomography
Opis:
Badanie TK w protokole politrauma jest podstawowym działaniem diagnostycznym w przypadku urazu wielonarządowego. Celem pracy była analiza częstości występowania zmian urazowych u pacjentów poddanych badaniu TK-politrauma. Retrospektywnie przeanalizowano grupę 520 pacjentów. Stwierdzono, że jedynie w 67% przypadków wystąpiły zmiany urazowe. Zmiany te częściej dotyczyły mężczyzn (73%) i najczęściej obejmowały kręgosłup, klatkę piersiową i głowę.
CT examination in politrauma protocol is a basic diagnostic activity in the case of multiorgan injury. The purpose of this study was the analisys of the frequency of post-traumatic changes occurance for the patients submited to CT-politrauma examination. Retrispoctively the group 520 patients were analised. It was certified that in only 67% cases post-traumatic changes occur. Those changes more frequently concerned men (73%) and as often as not ranged spine, chest and head.
Źródło:
Inżynier i Fizyk Medyczny; 2018, 7, 2; 77-80
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pasywna tarcza termiczna do prowadzenia szkoleń i strzelań w dzień i w nocy
Passive thermal target for day and night time training and firing
Autorzy:
Świderski, W.
Hłosta, P.
Polak, P.
Tymiński, D.
Powiązania:
https://bibliotekanauki.pl/articles/235809.pdf
Data publikacji:
2017
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
szkolenie strzeleckie
podczerwień
tarcza termiczna
firing training
infrared
thermal target
Opis:
W artykule przedstawiono koncepcję tarczy termicznej. Tarcza ta zapewnia prowadzenie strzelań z użyciem celowników noktowizyjnych i termowizyjnych w warunkach nocnych i dziennych bez wymiany tarczy. Obraz tarczy w celownikach nocnych jest widoczny dzięki owietleniu jej przez reflektor podczerwieni. Tarcza jest tak skonstruowana, aby odbity od tarczy strumień promieniowania podczerwonego był skierowany do obiektywu celownika. W porównaniu z dotychczas stosowanymi rozwiązaniami nowa tarcza termiczna ma wiele zalet: jest natychmiast gotowa do działania po oświetleniu przez reflektor bez konieczności dugotrwałego podgrzewania, zużywa znacznie mniej energii i cechuje ją większa żywotność. Projekt jest obecnie na etapie badań prototypu tarczy.
A concept of a thermal target is presented in the paper. The same target may be used for firings with night-vision and thermo-vision sights at day and night conditions. A picture of the target is visible for it is lit by an infrared spotlight. The design of the target makes the beam of reflected infrared radiation hit the optics of a sight. The new thermal target has many advantages comparing to existing solution: it is ready to operate straightforwardly after lighting by the spotlight, without any need for a long time preheating, the consumption of energy is significantly reduced, and its life cycle is increased. The project is currently in the phase of testing the target’s prototype.
Źródło:
Problemy Techniki Uzbrojenia; 2017, 46, 143; 7-16
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hilbert curve fractal antenna for detection and on-line monitoring of partial discharges in power transformers
Antena fraktalna Hilberta do detekcji i monitoringu wyładowań niezupełnych w transformatorach energetycznych
Autorzy:
Sikorski, W.
Szymczak, C.
Siodła, K.
Polak, F.
Powiązania:
https://bibliotekanauki.pl/articles/300766.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
fault diagnosis
maintenance of power transformers
partial discharge detection
monitoring
UHF method
Hilbert curve fractal antenna
diagnostyka uszkodzeń
eksploatacja transformatorów energetycznych
detekcja wyładowań niezupełnych
monitoring wyładowań niezupełnych
metoda UHF
antena fraktalna Hilberta
Opis:
This article describes the design of UHF Hilbert curve fractal antenna (HCFA) specially adapted for the partial discharge monitoring system. The authors present the mathematical apparatus for calculating resonant frequencies of Hilbert fractal antenna and results of a computer simulation of the developed prototype. In the design process, the antenna’s working environment (mineral oil) and the mechanical construction of the transformer inspection window were taken into consideration as well. The article also shows the results of laboratory tests carried out in the transformer tank model with different type of partial discharge sources. Both simulations and partial discharge measurements showed that the HCFA, due to such properties as: multi-resonance, small size, low fabrication cost and high sensitivity, is an interesting alternative to other UHF probes installed in transformer inspection window.
W artykule zaprezentowano projekt anteny fraktalnej Hilberta przeznaczonej do stosowania w systemach monitoringu wyładowań niezupełnych wykorzystujących metodę UHF. Autorzy szczegółowo opisali aparat matematyczny służący do estymacji częstotliwości rezonansowych anteny fraktalnej Hilberta oraz wyniki symulacji komputerowych. Ponadto, w artykule zaprezentowano wyniki pomiarów laboratoryjnych, w trakcie których generowano impulsy wyładowań niezupełnych w modelu kadzi transformatora energetycznego. Zarówno wyniki symulacji komputerowych jak i pomiarów laboratoryjnych wykazały, że prototypowa antena fraktalna Hilberta, dzięki takim własnościom jak: wielorezonansowość, małe wymiary, niski koszt produkcji oraz wysoka czułość, stanowi ciekawą alternatywę dla innych czujników UHF instalowanych w oknie rewizyjnym transformatora energetycznego.
Źródło:
Eksploatacja i Niezawodność; 2018, 20, 3; 343-351
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Work on developing a thermal shooting target
Autorzy:
Swiderski, W.
Hłosta, P.
Polak, G.
Tymiński, D.
Powiązania:
https://bibliotekanauki.pl/articles/114252.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
thermal target
infrared
emissivity
shooting
Opis:
The paper presents work on the development of a thermal target providing for shooting with the use of night-vision and thermovision sights in night conditions as well as during the day, without changing the target. The image of the target in the night sight is visible by illuminating it through an IR lamp. The target is designed so that the reflected IR stream is directed towards the objective lens. Compared to existing solutions, the new thermal target has a number of advantages, such as it does not require long-time heating and is immediately ready to operate after thermal lamp lighting, significantly reducing energy consumption. The project is currently at the stage of prototype target testing.
Źródło:
Measurement Automation Monitoring; 2017, 63, 4; 158-161
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies