Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Podgórni, E." wg kryterium: Autor


Wyświetlanie 1-11 z 11
Tytuł:
Determination of density and classification of post-coagulation sediment
Autorzy:
Podgórni, E.
Rząsa, M.
Powiązania:
https://bibliotekanauki.pl/articles/114294.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
sedimentation
coagulation
sediment density
Opis:
The coagulation process is one of the water and wastewater treatment processes. It results in the precipitation of sediment. After the coagulation process, the density of the sediment has a significant impact on the sedimentation rate of particles. These particles have different shapes, sizes and structures, and they settle in a different way. The particle density has an impact on the settling rate. The structure of particles results in two types of pores. Micropores are characteristic features of the sediment, but macropores should not be considered while determining the density. In this paper sediment samples were prepared and the density was determined using the gravimetric method by means of the press. The number of press strokes should not destroy the microstructure of sediment. The authors determined the degree of sample compression to minimize errors while determining the density. The volume of samples was obtained using X-ray tomography and image processing. The correct determination of the sample volume depends on the correct number of the threshold. Image processing was performed using LabVIEW software and Vision module. The paper presents the statistic classification of post-coagulation particles and the results of tests.
Źródło:
Measurement Automation Monitoring; 2017, 63, 1; 32-35
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przegląd metod pomiarowych opartych na tomografii optycznej w zastosowaniu do wyznaczania parametrów przepływów gaz-ciecz
Review of methods of measuring based on optical tomography applicable to determining flow parameters of gas-liquid
Autorzy:
Rząsa, M.
Podgórni, E.
Powiązania:
https://bibliotekanauki.pl/articles/408780.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
tomografia optyczna
analiza obrazu
przepływ dwufazowy
optical tomography
image processing
two-phase flow
Opis:
W pracy przedstawiono przegląd metod tomografii optycznej, stosowanych do badania przepływu dwufazowego gaz-ciecz. Wykorzystanie tomografii optycznej pozwala wyznaczać parametry ruchu fazy rozproszone (gazowej). W opracowaniu przedstawiono ideę pomiaru oraz opisano własne metody prześwietlania obiektów badanych. Przeprowadzono analizę możliwości zastosowania poszczególnych metod do pomiaru wybranych parametrów przepływu dwufazowego. Opisano metodę prześwietlania równoległą i rozproszoną wiązką światła oraz trójwymiarową metodę analizy obrazu. Prezentowane metody mogą posłużyć do pomiaru pęcherzyków w cieczach przeźroczystych, ale również ruchu kropli cieczy w gazie, ciał stałych w cieczy lub ciał stałych w gazie.
Optical tomography is a diagnostic method that allows to obtain a wide range of images. With these images, you can perform the submission of horizontal or spatial test object. This paper presents a number of imaging methods used to study the flow of two-phase gas-liquid. The use of optical tomography allowed to track the movement of air bubbles during their flow through the test column. The presented methods can be used to measure the bubbles in transparent fluids, but also the movement of a drop of liquid in gas, solids in liquids or solids in the gas.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2017, 7, 1; 161-164
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda pomiaru gęstości osadu pokoagulacyjnego z zastosowaniem tomografii rentgenowskiej
Measurement method of sediment densities after coagulation using x-ray tomography
Autorzy:
Rząsa, M. R.
Podgórni, E.
Powiązania:
https://bibliotekanauki.pl/articles/268323.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
gęstość osadu
koagulacja
mikrotomografia rentgenowska
density of sediment
coagulation
X-ray microtomography
Opis:
Koagulacja jest jednym z procesów oczyszczania wody. Polega na destabilizacji układu koloidalnego i aglomeracji cząstek, które następnie usuwa się w procesach sedymentacji, flotacji czy filtracji. Powstałe cząstki pokoagulacyjne charakteryzują się zróżnicowanym kształtem, wielkością oraz strukturą. Szybkość opadania takich cząstek w dużej mierze zależy od ich gęstości. Struktura cząstek powoduje, że wyróżnia się dwa rodzaje porów. Makropory, które nie powinny być uwzględniane przy wyznaczaniu gęstości oraz mikropory, które stanowią cechę charakteryzującą dany osad pokoagulacyjny. Gęstość wyznaczono metodą wagową dla odpowiednio przygotowanych próbek. Ponieważ proces prasowania może niszczyć mikrostrukturę osadu, przeprowadzono badania mające na celu określenie stopnia sprasowania próbek, aby zminimalizować błędy wyznaczenia gęstości. Badania te prowadzono za pomocą tomografu rentgenowskiego, dzięki któremu możliwe było wyznaczenie objętości danej próbki z korektą makroporowatości. W pracy przedstawiono wyniki badań oraz parametry graniczne procesu przygotowywania próbek.
Coagulation is one of the processes of water purification, which consists in the destabilization of the dispersion and agglomeration of the particles, which are removed in the process of sedimentation, flotation or filtration. After the coagulation particles have a varied shape, size and porous structure. The rate of descent of such particles largely depends on their density. The structure of the particles causes two types of pores. Macropores that should not be taken into account when determining the density, and micropores, which are a characteristic feature of the sediment after coagulation process. To determine the density of sludge samples were subjected to compression, in order to eliminate the macropores and then, after designation of sample volume, density was determined by weighing. The precipitate was prepared based on a prepared water model, to which was added a coagulant Flokor 1.2A. The precipitate was filtered on a cellulose filter, and then subjected to a drying process. The dry sludge was pressed on the press impact. Because of the pressing process can destroy the microstructure of the sediment, studies have been conducted to determine the degree of compression of samples to minimize errors while determine the density. These studies were carried out using X-ray tomography, it was possible to designate the volume of the sample while subtraction residues macropores. For the correct determination of the volume, determination the correct number of threshold is necessary, based on which is possible to qualify individual pixels. In order to clearly identify which pixels represent sediment, it was necessary to carry out the image processing. That process were performed using LabVIEW software and Vision module. The paper presents results of research for density measurement and sets limits for the sample preparation process.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 159-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar chaotycznego tworzenia się pęcherzyków gazu z zastosowaniem programu LabVIEW
Measurement of the chaotic gas bubble formation using LabVIEW
Autorzy:
Podgórni, E.
Rząsa, M. R.
Ziemnicka, E.
Powiązania:
https://bibliotekanauki.pl/articles/209372.pdf
Data publikacji:
2014
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
chaos deterministyczny
bifurkacja
tworzenie się pęcherzy gazowych
deterministic chaos
bifurcation
bubbles
Opis:
Zjawisko chaosu deterministycznego występuje wskutek zmian parametrów układu. W badaniach poszukiwano bifurkacji - punktów utraty stabilności układu podczas tworzenia się pęcherzyków gazu. Specjalnie utworzone stanowisko połączone z oprogramowaniem LabVIEW pozwalało na mierzenie czasu powstawania pęcherzy przy zmiennym natężeniu objętościowym gazu. Określony został wpływ kształtu oraz średnicy dyszy na osiąganie przez układ stanu chaosu deterministycznego.
The article presents the results of research on the prevalence of deterministic chaos during the formation of gas bubbles. In order to measure the time of the formation of gas bubbles a test bench was built. The research allowed us to determine the bifurcation diagrams for cylindrical and conical nozzles. Bifurcation occurs and it causes that we can see two points for the same gas stream. The system loses stability gradually until the appearance of chaos, i.e., the total instability of the system.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2014, 63, 3; 115-121
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu zmiany próbobiorcy na niepewność związaną z opróbowaniem w monitoringu wód podziemnych
Estimation of sampler influence on uncertainty associated with sampling in groundwater monitoring
Autorzy:
Kmiecik, E.
Podgórni, K.
Powiązania:
https://bibliotekanauki.pl/articles/2063221.pdf
Data publikacji:
2009
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
monitoring wód podziemnych
ocena stanu chemicznego
niepewność związana z opróbowaniem
groundwater monitoring
chemical status assessment
sampling uncertainty
Opis:
Dyrektywy Unii Europejskiej RDW (2000) oraz DWP (2006) nakładają na państwa członkowskie konieczność oszacowania niepewności (poziomu ufności) i dokładności, również związanych z procesem opróbowania, otrzymanych w ramach monitoringu wyników. W niniejszej pracy dokonano oceny wpływu zmiany próbobiorcy na niepewność związaną z opróbowaniem. W tym celu wykonano dwie serie opróbowania wód podziemnych ze zdroju Królewskiego w Krakowie. Dwóch próbobiorców (J i K) pobierało w taki sam sposób próbki kontrolne (normalne i dublowane), które następnie były analizowane w tym samym laboratorium za pomocą takiej samej metody (PN-EN ISO 17294-2:2006, PN-EN ISO 17294-1:2007). Laboratorium ma wdrożony system jakości zgodny z normą PN-EN ISO/IEC 17025:2005. Oszacowanie niepewności całkowitej i jej składowych przeprowadzono oddzielnie dla każdego próbobiorcy. Szczegółowej analizie poddano wyniki oznaczeń żelaza (granica oznaczalności żelaza metodą ICP-MS wynosi 0.01 mg/1). W celu identyfikacji obserwacji odstających wykorzystano wykres rozrzutu oraz karty: rozstępu i różnic (NORDTEST, 2006). Do obliczenia wariancji całkowitej, udziałów wariancji geochemicznej, opróbowania i analitycznej oraz niepewności standardowej (u), rozszerzonej (U) i względnej (U') wykorzystano program ROBAN. W obu przypadkach (seria J i K) dominuje wariancja geochemiczna. Niepewność związana z opróbowaniem wynosi dla serii J 13% (przy średniej zawartości żelaza w analizowanych próbkach 775,69 micro/g/1), a niepewność całkowita 50,42%. (f391,10 micro/g/I). W przypadku serii K, niepewność związana z opróbowaniem ma mniejszą wartość - 4% (przy średniej zawartości żelaza 890,18 micro/g/1), podobnie jak niepewność całkowita - 30,32% (f269,90 micro/g/1). W obu przypadkach oszacowana dla stężeń żelaza ze zdroju Królewskiego w Krakowie niepewność całkowita nie będzie wpływać na ocenę stanu chemicznego.
According to European Union directives (RDW, 2000; DWP, 2006) the identification and determination of uncertainty - also this associated with sampling, preservation and transport of samples - is an important part of the overall groundwater monitoring effort. In this work, the influence of sampler on the uncertainty estimation is taken into account. Two independent people (sampler J and K) were taken normal and duplicate samples from Królewski spring using the same sampling protocols. The same analytical method was used - ICP-MS (PN-EN ISO 17294-2:2006, PN-EN ISO 17294-1:2007). All samples were analyzed in hydrogeochemical laboratory which has implement extensive quality assurance and analytical quality control programs. Calculation of uncertainty and its components for this two operators has been shown in details for iron, Fe (limit of determination: 0.01 mg/1). To identificate the outliers, scatter plot, chart of differences and range chart were used (according to NORDTEST, 2006). To calculate the total variance separated into three parts (geochemical, sampling and analytical variance), standard (u), expanded (U) and relative (U') uncertainty for each of these components, ROBAN software was used. In both sampling capaigns the geochemical variance is dominating in the monitored well. For J campaign, sampling uncertainty amounts 13% (with average iron concentration 775.69 žg/1) and total uncertainty is 50.42%. (f 391.10 micro/g/1). For K campaign, sampling uncertainty is smaller - 4% (with average iron concentration 890.18 micro/g/1) and total uncertainty too - 30.32% (f 269.90 micro/g/1). In both cases, estimated total uncertainty has not influence on estimation of groundwater chemical status of Królewski spring.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2009, 436, z. 9/1; 253-260
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic Properties of $Sn_{1-x}Cr_xTe$ Diluted Magnetic Semiconductors
Autorzy:
Kilanski, L.
Podgórni, A.
Górska, M.
Dobrowolski, W.
Slynko, V.
Slynko, E.
Reszka, A.
Kowalski, B.
Powiązania:
https://bibliotekanauki.pl/articles/1399145.pdf
Data publikacji:
2013-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
72.80.Ga
75.30.Hx
75.30.Et
75.50.Pp
Opis:
We present the studies of $Sn_{1-x}Cr_xTe$ semimagnetic semiconductors with chemical composition x ranging from 0.004 to 0.012. The structural characterization indicates that even at low average Cr-content x ≤q 0.012, the aggregation into micrometer size clusters appears in our samples. The magnetic properties are affected by the presence of clusters. In all our samples we observe the transition into the ordered state at temperatures between 130 and 140 K. The analysis of both static and dynamic magnetic susceptibility data indicates that the spin-glass-like state is observed in our samples. The addition of Cr to the alloy seems to shift the spin-glass-like transition from 130 K for x = 0.004 to 140 K for x = 0.012.
Źródło:
Acta Physica Polonica A; 2013, 124, 5; 881-884
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Anomalous Hall Effect in $Ge_{1-x-y}Pb_{x}Mn_{y}Te$ Composite System
Autorzy:
Podgórni, A.
Kilanski, L.
Dobrowolski, W.
Górska, M.
Domukhovski, V.
Brodowska, B.
Reszka, A.
Kowalski, B.
Slynko, V.
Slynko, E.
Powiązania:
https://bibliotekanauki.pl/articles/1376191.pdf
Data publikacji:
2014-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.72.J-
72.80.Ga
75.40.Mg
75.50.Pp
Opis:
The purpose of this study was to investigate the magnetotransport properties of the $Ge_{0.743}Pb_{0.183}Mn_{0.074}Te$ mixed crystal. The results of magnetization measurements indicated that the compound is a spin-glass-like diluted magnetic semiconductor with critical temperature $T_{SG}$=97.5 K. Nanoclusters in the sample are observed. Both, matrix and clusters are magnetically active. Resistivity as a function of temperature has a minimum at 30 K. Below the minimum a variable-range hopping is observed, while above the minimum a metallic-like behavior occurs. The crystal has high hole concentration, p=6.6×$10^{20}$ $cm^{-3}$, temperature-independent. Magnetoresistance amplitude changes from -0.78 to 1.18% with increase of temperature. In the magnetotransport measurements we observed the anomalous Hall effect with hysteresis loops. Calculated anomalous Hall effect coefficient, $R_{S}$ = 2.0×$10^{6}$ $m^{3}$/C, is temperature independent. The analysis indicates the extrinsic skew scattering mechanism to be the main physical mechanism responsible for anomalous Hall effect in $Ge_{0.743}Pb_{0.183}Mn_{0.074}Te$ alloy.
Źródło:
Acta Physica Polonica A; 2014, 126, 5; 1180-1183
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Role of Frustration in Magnetism of Ge$\text{}_{1-x}$Cr$\text{}_{x}$Te Semimagnetic Semiconductor
Autorzy:
Kilanski, L.
Górska, M.
Dobrowolski, W.
Arciszewska, M.
Domukhovski, V.
Anderson, J. R.
Butch, N. P.
Podgórni, A.
Slynko, V. E.
Slynko, E. I.
Powiązania:
https://bibliotekanauki.pl/articles/2048082.pdf
Data publikacji:
2011-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.40.Cx
75.40.Gb
75.50.Lk
75.50.Pp
Opis:
We present preliminary studies of magnetic properties of Ge$\text{}_{1-x}$Cr$\text{}_{x}$Te semimagnetic semiconductors with low chromium content x < 0.026. The static and dynamic magnetometry techniques were employed for the current investigations. The obtained results showed large bifurcations between zero-field cooled and field cooled magnetization curves at temperatures lower than 50 K. The dynamic susceptibility measurements proved via frequency shifting of the peaks that the observed magnetic order at low temperatures was the spin-glass-like state caused by magnetic frustration of the system.
Źródło:
Acta Physica Polonica A; 2011, 119, 5; 654-656
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spinodal Decomposition of Magnetic Ions in Eu-Codoped $Ge_{1-x}Cr_{x}Te$
Autorzy:
Podgórni, A.
Kilanski, L.
Dobrowolski, W.
Górska, M.
Reszka, A.
Domukhovski, V.
Kowalski, B.
Brodowska, B.
Anderson, J.
Butch, N.
Slynko, V.
Slynko, E.
Powiązania:
https://bibliotekanauki.pl/articles/1403631.pdf
Data publikacji:
2012-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
72.80.Ga
75.40.Cx
75.40.Mg
75.50.Pp
Opis:
We present the experimental evidence for the presence of spinodal decomposition of the magnetic ions in the $Ge_{1-x-y}Cr_{x}Eu_{y}Te$ samples with chemical composition varying in the range of 0.015 ≤ x ≤ 0.057 and 0.003 ≤ y ≤ 0.042. The ferromagnetic transition at temperatures 50 ≤ T ≤ 57 K was observed, independent of the chemical composition. The long-range carrier mediated itinerant magnetic interactions seem to be responsible for the observed ferromagnetic order. The magnetic irreversibility with coercive field $H_C$ = 5 - 63 mT and the saturation magnetization $M_S$ ≈ 2 - 6 emu/g are found to strongly depend on the chemical composition of the alloy.
Źródło:
Acta Physica Polonica A; 2012, 122, 6; 1012-1015
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method of magnetic field measurement in a scanning electron microscope using a microcantilever magnetometer
Autorzy:
Orłowska, Karolina
Mognaschi, Maria E.
Kwoka, Krzysztof
Piasecki, Tomasz
Kunicki, Piotr
Sierakowski, Andrzej
Majstrzyk, Wojciech
Podgórni, Arkadiusz
Pruchnik, Bartosz
di Barba, Paolo
Gotszalk, Teodor
Powiązania:
https://bibliotekanauki.pl/articles/220725.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
scanning electron microscope
magnetometry
microcantilever
Opis:
Scanning electron microscopy (SEM) is a perfect technique for micro-/nano-object imaging [1] and movement measurement [2, 3] both in high and environmental vacuum conditions and at various temperatures ranging from elevated to low temperatures. In our view, the magnetic field expanding from the pole-piece makes it possible to characterize the behaviour of electromagnetic micro- and nano-electromechanical systems (MEMS/NEMS) in which the deflection of the movable part is controlled by the electromagnetic force. What must be determined, however, is the magnetic field expanding from the e-beam column, which is a function of many factors, like working distance (WD), magnification and position of the device in relation to the e-beam column. There are only a few experimental methods for determination of the magnetic field in a scanning electron microscope. In this paper we present a method of the magnetic field determination under the scanning electron column by application of a silicon cantilever magnetometer. The micro-cantilever magnetometer is a silicon micro-fabricated MEMS electromagnetic device integrating a current loop of lithographically defined dimensions. Its stiffness can be calibrated with a precision of 5% by the method described by Majstrzyk et al. [4]. The deflection of the magnetometer cantilever is measured with a scanning electron microscope and thus, through knowing the bias current, it is possible to determine the magnetic field generated by the e-beam column in a defined position and at a defined magnification.
Źródło:
Metrology and Measurement Systems; 2020, 27, 1; 141-149
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic Order and Magnetic Inhomogeneities in SnCrTe-PbCrTe Solid Solutions
Autorzy:
Kilanski, L.
Szymański, M.
Brodowska, B.
Górska, M.
Szymczak, R.
Podgórni, A.
Avdonin, A.
Reszka, A.
Kowalski, B.
Domukhovski, V.
Arciszewska, M.
Dobrowolski, W.
Slynko, V.
Slynko, E.
Powiązania:
https://bibliotekanauki.pl/articles/1376790.pdf
Data publikacji:
2014-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
72.80.Ga
75.30.Hx
75.30.Et
75.50.Pp
Opis:
We present the studies of structural, electrical and magnetic properties of bulk $Sn_{1-x-y}Pb_xCr_yTe$ mixed crystals with chemical composition 0.18 ≤ x ≤ 0.35 and 0.007 ≤ y ≤ 0.071. The magnetometric studies indicate that for the high Cr-content, y=0.071, the alloy shows ferromagnetic alignment with the Curie temperature, $T_{C}$, around 265 K. The $Cr_5Te_8$ clusters are responsible for the ferromagnetic order. At low Cr content, y ≈ 0.01, a peak in the ac magnetic susceptibility identified as the cluster-glass-like transition is observed at a temperature about 130 K. The cluster-glass-like transition is likely due to the presence of $Cr_2Te_3$ clusters in the samples with y ≈ 0.01. The transport characterization of the samples indicated strong metallic p-type conductivity with relatively high carrier concentration, n > $10^{20}$ $cm^{-3}$, and carrier mobility, μ > 150 $cm^2$/(V s).
Źródło:
Acta Physica Polonica A; 2014, 126, 5; 1203-1206
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies