Tytuł:
Phonon-Assisted Tunneling of an Electron in a Strained Self-Assembled Quantum Dot Molecule
Autorzy:
Pochwała, M.
Machnikowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/1811973.pdf
Data publikacji:
2008-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
73.21.La
73.63.Kv
63.20.kd
Opis:
We calculate phonon-assisted relaxation rates in a self-assembled quantum dot molecule. The calculation is based on wave functions obtained within an envelope function approach, including strain effects. The single-phonon relaxation is shown to be efficient for separations between the dots around 10 nm when, in addition, the dots are brought close to resonance.
Źródło:
Acta Physica Polonica A; 2008, 114, 5; 1285-1291
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synteza bimetalicznego silseskwioksanowego kompleksu tytanu(IV) i jego polimerycznego odpowiednika oraz ich właściwości katalityczne w polimeryzacji olefin
Synthesis and catalytic behavior in olefin polymerization of bimetallic titanium(IV) silsesquioxane complex and its polymeric counterpart
Autorzy:
Pochwała, M.
Białek, M.
Franczyk, A.
Czaja, K.
Marciniec, B.
Powiązania:
https://bibliotekanauki.pl/articles/947284.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
polimeryzacja Zieglera-Natty
polietylen
poli(1-okten)
mikrostruktura
kompleks tytanu
silseskwioksan
Ziegler-Natta polymerization
polyethylene
poly(1-octene)
microstructure
titanium complex
silsesquioxane
Opis:
Zsyntetyzowano, a następnie scharakteryzowano dwa tytanosilseskwioksany: nowy, nieznany dotąd z literatury, tetrachloroditytanosilseskwioksan (2) i jego polimeryczny odpowiednik (3). Zbadano właściwości katalityczne otrzymanych związków w polimeryzacji etylenu i 1-oktenu. Obydwa prekatalizatory, po aktywacji za pomocą Et2AlCl lub EtAlCl2, katalizują polimeryzację etylenu do polietylenu (PE) o małej masie molowej, która zmniejsza się zarówno ze wzrostem temperatury reakcji, jak i stosunku molowego Al:Ti. Kompleks (2) w połączeniu z metyloaluminoksanem lub związkami boru jest także aktywny w polimeryzacji 1-oktenu.
The new compound, tetrachlorodititanasilsesquioxane (2) and its polymeric analogue (3) have been synthesized, characterized and used for the first time in ethylene and 1-octene polymerization. These precatalysts, activated by Et2AlCl and EtAlCl2, were found to be catalytically active in polymerization of ethylene. The resulting polyethylenes have rather low molecular weight, decreasing with an increase in both reaction temperature and molar ratio of Al:Ti. In the presence of methylaluminoxane or boron compounds, the complex (2) also promotes polymerization of 1-octene.
Źródło:
Polimery; 2016, 61, 9; 591-599
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ deformacji profilu prędkości na wartość współczynnika przepływu przepływomierza z rurką uśredniającą ciśnienie dynamiczne
Influence of velocity profile deformation on flow averaging tube flow coefficient
Autorzy:
Kabaciński, M.
Pochwała, S.
Powiązania:
https://bibliotekanauki.pl/articles/151449.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
profil prędkości
pomiary przepływów
rurki uśredniające ciśnienie dynamiczne
niepewność pomiaru
velocity profile
flow measurements
flow averaging tubes
measurement uncertainty
Opis:
W pracy przedstawiono zasadę działania rurek uśredniających oraz stanowisko do ich wzorcowania. Zaprezentowano wyniki badań eksperymentalnych pomiaru strumienia powietrza przepływomierzami spiętrzającymi w strefie zaburzonego przepływu za pojedynczym kolanem. Określono profile prędkości w wybranych miejscach instalacji. Wyznaczono charakterystyki współczynnika przepływu K dla rurki o kształcie opływowym. Podano wartości współczynnika korekcyjnego umożliwiającego zmniejszenie niepewności pomiaru przepływu rurką uśredniającą. Wykazano, że lokalizacja przepływomierza poniżej 5D za kolanem powoduje istotny wzrost niepewności pomiaru.
This paper presents experimental results of the air flow across an obstacle formed by a 90 degree segmented elbow. The internal diameter of the pipeline was D=152 mm, while the range of the mean velocities w = 10 30 m/s. The velocity profiles were determined (using Prandtl tube) both in the vertical and horizontal plane [12] in the relative distances L/D of the pipeline from 3 D to 20 D (Figs. 5 and 6). In the places of the established velocity profiles a streamlined flow averaging tube [7] was placed to determine the characteristics of the flow coefficient K (Figs. 8 and 9) as a function of the mean velocity (and Re number). The scope of this paper is also to present an automated test stand (equipped with a dedicated computer program - data acquisition) for calibrating flowmeters. The results of the experiments are given in the form of charts and compared. Analysis of the effect of changing the position of the averaging probe (vertical, horizontal) was conducted together with examination of the influence of the distance behind the obstacle (elbow) on the K-factor value. The realized experiment allowed shortening the distance between the obstacle and flowmeter installation place and informing about the correction factor value which can be used to minimise the uncertainty of the air flow rate measurement (Fig. 10). It was assumed that the horizontal plane is better for probe installation because of almost axi-symmetrical velocity profile and better repeatability of measurement points (K-factor changes by about 1%).
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 2, 2; 157-160
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of typical flow disturbing elements on the flow rate in selected averaging Pitot tubes
Autorzy:
Pochwała, S.
Kabaciński, M.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/1933974.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska
Tematy:
averaging pitot tubes
flowmeter
Opis:
Flowmeters with averaging Pitot tubes are becoming more and more common in the industrial practice. It is often the case in long straight sections of channels with large diameters that the conditions regarding the adequately long sections of pipelines before and behind a flowmeter cannot be fulfilled. This is associated with the occurrence of an additional measurement uncertainty with an unknown value. Most of the information regarding this issue can be found for the case of Venturi probes. The amount of data regarding the flow averaging Pitot tubes is also limited. Hence, the decision to undertake the proposed subject. The conducted research made it possible to state recommendations regarding the metrology of testing. The results indicate that it is not only the distance from the flow disturbing element that plays a role but it is also the plane in which the sensor is located that affects the uncertainty of measurements of the flow averaging Pitot tubes.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2012, 16, 3-4; 219-228
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda pomiaru prędkości ruchu cieczy zmodyfikowaną metodą PIV
Method of liquid flow measurement using a modified PIV method
Autorzy:
Rząsa, M.
Pochwała, S.
Czaplaniełacna, B.
Powiązania:
https://bibliotekanauki.pl/articles/267600.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wizualizacja przepływu
pomiar prędkości cieczy
flow visualization
liquid flow measurement
Opis:
W pracy przedstawiono wyniki badań pomiaru prędkości ruchu cieczy. Prędkość określono na podstawie zdjęć fotograficznych z wizualizacji ruchu cieczy, w której znajdowały się znaczniki optyczne. Przedstawiona metoda umożliwia wyznaczenie prędkości ruchu cieczy z dokładnością do kilku procent wartości mierzonej.
Phenomena related to the flow around different types of obstacles belong to one of the most difficult issues of fluid mechanics. Fluid flowing to the obstacle is disturbing what is associated with the formation of vortices. The frequency and intensity of vortices depend on flow and type of obstacle. The phenomenon is used in vortex flow meters. The paper present the test stand of flow visualization for vortex bluff bodies of vortex flowmeter. Very important parameter, which is necessary to designate in testing space is flow velocity. The paper proposes a method of measuring the velocity of liquid motion based on the image recorded during the visualization. The flow velocity was determined by the photographic images from the fluid flow visualization in which the tags were located. Pictures were taken with a camera with a long exposure time. The proposed method enables the determination of the fluid velocity to a certain percentage of the measured value. The uncertainty of this measurement significantly depends on the value of the measured velocity. In order to maintain the desired measurement accuracy, it is necessary to adjust the exposure time accordingly.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 54; 191-194
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eksperymentalne wyznaczanie profilu prędkości w kanale prostokątnym
Experimental determination of velocity profile in a rectangular channel
Autorzy:
Pochwała, S.
Rząsa, M.
Pawłowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/269080.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
turbulencja przepływu
prędkość przepływu
instalacje wentylacyjne
stabilizacja strugi
flow turbulence
flow velocity
ventilation installations
flow development
Opis:
Badania zrealizowane na potrzeby niniejszego artykułu miały na celu eksperymentalną ocenę wpływu typowego elementu armatury instalacyjnej oraz wartości turbulencji przepływu na wyznaczanie długość odcinka prostego pozwalającego na stabilizację strugi przepływającego płynu.
The research reported in this article was concerned with experimental evaluation of the effect of installation of a typical element of armature and the level of flow turbulence on the length of the straight tube section needed for the development of fluid flow. In order to carry out the tests, an experimental setup was built, which main element consists of a steel channel through which ambient air is delivered inside the installation. The channel has a square cross-section and length of 160 mm. Along this channel, a system of three 30o elbows was installed and combined to form a single 90° segmented bend. With the purpose of assessing the flow disturbance at specified distances from the flow obstruction, it was necessary to determine the velocity profile of the fluid flow in the channel. This goal applied a measuring system comprising a Pitot tube connected to a linear module. This setup provided the measurements of the velocity along the entire section of the channel with the measurement space traversed with a step equal to 2mm.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 59; 149-152
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies