Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pieńkos, P. J." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Wireless system for radiometric measurements
Autorzy:
Jakowiuk, A.
Pieńkos, P. J.
Kowalska, E.
Filipiak, P.
Świstowski, E.
Powiązania:
https://bibliotekanauki.pl/articles/146860.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radiometric probes
radon concentration measurements
wireless communication
Opis:
Wireless system for radiometric measurements contains probes, for gamma radiation measurements and other probes for radon concentration measurements in air and water. The probes have the form of droplet-tight cylinders powered from a local battery. Measuring data collecting unit, based on a portable computer, communicates directly with the probes in a wireless manner using the WiFi communication network, or through the internet using mobile phone GSM network. Serial port wire connection is also possible. The local battery ensures at least 14 days of continuous operation of the probes. For long term measurements, the probes can also be powered from solar panels. Construction and operation of the probes are described. Results of scintillation probes investigation are given. Detection efficiency of the developed probes is comparable with the laboratory probes offered in our country.
Źródło:
Nukleonika; 2012, 57, 4; 637-641
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory automatic measuring system for gamma specimens
Autorzy:
Jakowiuk, A.
Filipiak, P.
Bartak, J.
Pieńkos, P.
Kowalska, E.
Powiązania:
https://bibliotekanauki.pl/articles/146868.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
gamma counter
radioimmunoassay (RIA)
immunoradiometric assay (IRMA)
Opis:
LG Gamma Counter is designed for low activity measurement of the radioactive isotope iodine 125I in liquid or solid samples during radioimmunoassay (RIA) and immunoradiometric assay (IRMA) in small or medium size clinic laboratories. Apart from RIA and IRMA programmed procedures, a measurement of small activity gamma samples is possible. The well scintillator NaI(Tl) is used as radiation detector for the isotope 125 I in the measuring channel, the well dimensions fi being 17 x 38 mm. Gamma Counter was adapted for measuring radioactivity of single samples. The counter is equipped with an automatic system allowing transportation of examined samples to a scintillator well. The gauge is based on an integrated computer which is working under the control of Windows CE and is equipped with special software allowing for setting measurement parameters and communication with an external computer. The measured sample is placed inside the scintillator well either by an automatic sample feeder or manually. The pulses from a photomultiplier tube after amplification and shaping in pulse amplifiers are counted in the window of a single channel analyser by a programmable pulse counter under the control of microprocessor system. The measured count rate is the measure of activity of the assayed sample. Expected count rate error due to unstable operation of amplification is lower than 1%.
Źródło:
Nukleonika; 2012, 57, 4; 633-635
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrological features of a beta absorption particulate air monitor operating with wireless communication system
Autorzy:
Jakowiuk, A.
Urbański, P.
Świstowski, E.
Machaj, B.
Pieńkos, J.
Kowalska, E.
Powiązania:
https://bibliotekanauki.pl/articles/146846.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ambient air
beta-ray absorption
particulate matter
wireless communication
Opis:
A system for measurements of particulate matter in the ambient air, employing beta absorption instrument AMIZ-2007 with wireless communication facilities based on GPRS technology, is presented. Uncertainty of measurements caused by the counting statistics was analyzed and it was found that at least 3 h of sampling time is needed to achieve coefficient of variation lower than 20% for the average concentration of particulate matter in the ambient air exceeding 10 μg/m3. Application of a C-14 beta ray source instead of Pm-147 improves sensitivity of the measurement ca. two times. Some results of on-line operation of the system with PM10 and PM2.5 samplers are also shown.
Źródło:
Nukleonika; 2008, 53, suppl. 2; 37-42
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies