Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pecyna-Utylska, Paulina" wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Ion chromatography as a part of green analytical chemistry
Chromatografia jonowa jako część zielonej chemii analitycznej
Autorzy:
Michalski, Rajmund
Pecyna-Utylska, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/1845373.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
environment
water
ion chromatography
green chemistry
reference methods
środowisko
woda
chromatografia jonowa
Zielona Chemia
metody referencyjne
Opis:
Due to the increased environmental awareness, green chemistry becomes an important element of environmental protection. Unfortunately, it generate specifi c environmental costs, which are related to the use of toxic chemical reagents and waste generation. The most frequently determined analytes include inorganic and organic anions and cations. The methods used so far for their analysis in water, sewage and various other types of samples are increasingly being replaced by ion chromatography methods. This paper presents the most important advantages and limitations of ion chromatography in the context of “green analytical chemistry.” The progress of ion chromatography in gradient and isocratic elution, capillary and multidimensional ion chromatography, as well as miniaturization and methods of sample preparation for analysis, which allow to classify this technique as green analytical chemistry, are described.
Ze względu na zwiększoną świadomość ekologiczną, zielona chemia staje się ważnym elementem ochrony środowiska. Laboratoria na całym świecie przeprowadzają miliony analiz różnych substancji. Niestety generują one określone koszty środowiskowe, co związane jest stosowaniem toksycznych odczynników chemicznych i wytwarzaniem odpadów. Do najczęściej oznaczanych analitów należą aniony i kationy. Dotychczas stosowane metody ich analiz są coraz częściej zastępowane metodami chromatografii jonowej. W pracy przedstawiono najważniejsze zalety i ograniczenia chromatografii jonowej w kontekście „zielonej chemii analitycznej”. Opisano postępy w zakresie elucji gradientowej i izokratycznej, kapilarnej i wielowymiarowej IC, miniaturyzacji i metod przygotowania próbek, które pozwalają na jej zaliczenie do metod zielonej chemii analitycznej.
Źródło:
Archives of Environmental Protection; 2020, 46, 4; 3-9
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chemical characterization of bulk depositions in two cities of Upper Silesia (Zabrze, Bytom), Poland : Case study
Autorzy:
Michalski, Rajmund
Pecyna-Utylska, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/2203100.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metals
Upper Silesia
ions
metalloids
bulk deposition
carboxylic acids
Opis:
The chemical composition of bulk deposition is an important aspect of assessing ambient air pollution. It contributes significantly to the removal of pollutants from the atmosphere and their transfer to other ecosystems. Thus, it is a reliable determinant of environmental chemistry. Therefore, bulk deposition can be considered useful for tracking the migration path of substances from different sources. The aim of the study carried out at five measurement points in Zabrze and Bytom was to assess the content of selected physico-chemical parameters in bulk deposition. Samples were collected continuously from November 2019 to November 2020. In the collected samples the following were determined: COD, pH, conductivity, dissolved organic carbon, inorganic carbon and total carbon; inorganic anions (Cl-, SO42-, NO3-, NO2-, Br-, PO43-) and cations (Li+, Mg2+, Ca2+, Na+, K+, NH4+), metals and metalloids (Mn, Ni, Co, Cu, Zn, As, Cd, Pb, Cr, and Fe), and carboxylic acids (formic, acetic, oxalic). The obtained test results were statistically processed using Excel, and the normality of data distribution was verified by Shapiro-Wilk test. The results show that pollutants transported in the atmosphere and introduced with precipitation in the Zabrze and Bytom areas are a significant source of area pollution of the region.
Źródło:
Archives of Environmental Protection; 2022, 48, 2; 106--116
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of selected atmospheric amines in the presence of inorganic cations by isocratic ion chromatography
Oznaczanie wybranych amin atmosferycznych w obecności kationów nieorganicznych metodą izokratycznej chromatografii jonowej
Autorzy:
Pecyna-Utylska, Paulina
Michalski, Rajmund
Powiązania:
https://bibliotekanauki.pl/articles/24202696.pdf
Data publikacji:
2023
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
atmospheric amines
aliphatic amines
conductometric ion chromatography
method validation and optimization
aminy atmosferyczne
aminy alifatyczne
chromatografia jonowa
walidacja i optymalizacja metod
Opis:
The aim of this study was to optimize and validate the methodology for the determination of selected aliphatic amines in the presence of inorganic cations in environmental samples (rainwater, snow, particulate matter) by isocratic ion chromatography with suppressed conductometric detection. The obtained detection limits for selected aliphatic amines were 4.65 µg/L, 4.46 µg/L, and 12.4 µg/L for methylamine, dimethylamine, and trimethylamine, respectively. The relative standard deviation of repeatability for real samples was less than 6%. The recovery was within the range of 90.3%–100%. The developed methodology was applied to analyse wet deposition and particulate matter samples.
Celem pracy była optymalizacja i walidacja metodyki oznaczania wybranych amin alifatycznych w obecności nieorganicznych kationów w próbkach środowiskowych (woda deszczowa, śnieg, pył zawieszony) metodą izokratycznej chromatografii jonowej z detekcją konduktometryczną. Granice wykrywalności dla wybranych amin alifatycznych wyniosły 4,65 µg/L, 4,46 µg/L i 12,4 µg/L, odpowiednio dla metyloaminy, dimetyloaminy i trimetyloaminy. Precyzja powtarzalności dla próbek rzeczywistych była < 6%. Odzysk mieścił się w zakresie 90,3%–100%. Opracowana metodyka została zastosowana do analizy próbek depozycji mokrej (śnieg, deszcz) oraz próbek pyłu zawieszonego.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2023, 85; 29--41
0239-5223
2720-0779
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies