Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pawlus, B." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
A tensomeric and planimetric evaluation of the durability of the bond between an orthodontic bracket and enamel
Autorzy:
Pawlus, B.
Dyszkiewicz, A.
Špidlen, M.
Powiązania:
https://bibliotekanauki.pl/articles/306966.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dental adhesives
dental brackets
tensometric testing of bond
planimetric testing of bond
ARI index
tensometria
kości
ortodoncja
Opis:
The development of orthodontics has improved thanks to the introduction of adhesives which are physically and chemically akin to tooth enamel and brackets. These materials often fall short of the required durability standards. The objective was to evaluate the real strength of the adhesives and to introduce a proprietary device, generating multiple vectors of strength between dental brackets and the surface of enamel. 11 types of adhesive materials have been studied. 990 applications have been made using removed teeth, followed by a randomised creation of 11 groups containing 90 samples each. The threshold values of the strength needed to break the brackets off were determined in torsional, shear and tension strength tests. A comparison between tensometric and planimetric methods was made by means based on ARI index. Resistance was highest for torsional stress, weaker for shear stress and the weakest for tension stress. A correlation was found between tensometric results. The study attempted to systematise the methodology of direct tests.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 4; 33-42
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wytrzymałości mechanicznej klejów ortodontycznych w testach bezpośrednich
Evaluation of mechanical strength of orthodontic adhesives in direct tests
Autorzy:
Pawlus, B.
Dyszkiewicz, A.
Špidlen, M.
Powiązania:
https://bibliotekanauki.pl/articles/286102.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
kleje ortodontyczne
siła wiązania
ścinanie
skręcanie
rozciąganie
orthodontic bonds
bond strength
torsion
shear
tension
Opis:
Celem pracy było stworzenie stanowiska pomiarowego do porównania i oceny właściwości wytrzymałościowych klejów wykorzystywanych do mocowania zamków ortodontycznych na zębach. Utworzono stanowiska pomiarowe dla badań przeprowadzanych na maszynie wytrzymałościowej z tensometrem oporowym, miernikiem wagowym oraz z serwomechanizmem, umożliwiającej przeprowadzenie statycznych prób wytrzymałościowych. Autorski system pomiarowy umożliwia pozaustrojową ocenę maksymalnych naprężeń ścinających, rozciągających i skręcających, działających na zamek ortodontyczny, zespolony z powierzchnią zęba. Badaniom próbnym poddano następujące materiały łączące: Transbond XT 3M, Light Bond Reliance, Enlight Ormco. Sporządzono 90 próbek z usuniętymi zębami przedtrzonowy- mi ludzkimi. Utworzono losowo 3 grupy po 10 próbek. Każda grupa została przypisana do odpowiedniej metody badawczej. Badania przeprowadzono in vitro w temperaturze 24 stopni Celsjusza w godzinę po przytwierdzeniu zamka. Dla próby ścinania najwyższe wartości średnich naprężeń granicznych wykazał Transbond XT. Najniższe wartości średnie ustalono dla Enlight Ormco. Dla próby rozciągania najwyższe wartości średnich naprężeń granicznych wykazał Enlight Ormco. Najniższe wartości średnie ustalono dla Transbond XT 3M. Najwyższe średnie wartości dla momentu skręcającego, przy którym doszło do zerwania materiału zarejestrowano dla Light Bond Reliance. Najniższe wartości średnie wykazał Enlight Ormco. Wyniki testów tensometrycznych wykazywały w badanych materiałach zbieżny trend największej odporności na działanie sił skręcających, mniejszy na działanie sił ścinających i najmniejszy na wpływ sił rozciągających. Rozbicie wypadkowej na poszczególne składowe naprężenia odzwierciedla naturalne zachowania wytrzymałościowe materiału łączącego z zamkami ortodontycznymi.
New materials for fastening teeth braces enabled more common use of the fixed appliances. Binding strength is being transferred to the teeth by orthodontic brackets fitted with linking material. A common problem is brackets peeling off. Information about the material strength is essential for adhesive selection. The aim of the study was to develop measurement system for comparison and estimation of binding properties of the bond used for orthodontic appliances. Measurement system allows to evaluate maximum shear, tension and torsion stress. The following materials were tested in the study: 3M Transbond XT, Reliance Light Bond, Ormco Enlight. 90 samples of human premolars were made. Three groups of 10 samples were created. Each group was assigned to the particular method and to the adhesive test. The maximal and minimal values of average shear stress were demonstrated with Transbond XT and Ormco Enlight. Tension stress showed maximal mean values for Ormco Enlight, minimal for 3M Transbond XT. The maximal mean values of torsion were recorded for Reliance Light Bond, the minimal for Ormco Enlight. The results showed the greatest resistance convergent trend for torsion, less significant for shear and the least influence of tension forces. Components of the net force reflect the natural behavior of the orthodontic adhesives.
Źródło:
Engineering of Biomaterials; 2012, 15, 115; 38-44
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics of the regional human milk bank in Poland - donors, recipients and nutritional value of human milk
Autorzy:
Barbarska, O.
Zielinska, M.
Pawlus, B.
Wesolowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/872945.pdf
Data publikacji:
2017
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
human nutrition
regional bank
human milk
breast milk
premature infant
enteral nutrition
human milk value
human milk bank
milk bank
Polska
Opis:
Background. In case of shortage of breast milk despite proper lactation care or the poor state of the mother’s health, breast milk from human milk bank is recommended for feeding preterm infants. Objective. This study retrospectively evaluated the first year of the operation of the Regional Human Milk Bank. Material and methods. Data concerning donors was collected in the human milk bank during the cooperation. The clinical characteristics of the recipients was made on the basis of medical documentation from the Holy Family Hospital in Warsaw, Poland. Analysis of nutritional value was performed with the human milk analyzer (MIRIS AB). Results. In the first year of activity, 45 voluntary donors established cooperation, donating from 650 to 32030 ml of human milk. The content of nutrients in milk provided by donors was variable - protein 0.4-1.5 g / 100 ml, fat 1.1-7.4 g / 100 ml, carbohydrates 6.3-7.9 g / 100 ml. The average length of using donated human milk was 4 days and the average volume of milk for one infant was 282 ml. Conclusions. The donor profiles have a significant impact on the milk composition form HMB. The nutritional value can be improved by recruitment donors from mothers that gave birth prematurely and by beginning donation at earlier stages of lactation as soon as lactation is stabilized. In case of shortage of mothers own milk the immediate implementation of donors milk as a short-term support can significantly reduce the food intolerance incidence in the group of prematurely born infants
Wprowadzenie. W przypadku niedoboru pokarmu biologicznej matki, pomimo odpowiedniej opieki laktacyjnej lub złego stanu zdrowia matki, zalecane jest żywienie noworodków przedwcześnie urodzonych pokarmem pochodzącym z banku mleka kobiecego. W krajach Europejskich, w tym w Polsce następuje gwałtowny wzrost liczby banków mleka. Cel badań. Celem badania była retrospektywna analiza pierwszego roku funkcjonowania Regionalnego Banku Mleka Kobiecego w Szpitalu im. Świętej Rodziny w Warszawie. Materiał i metody. Charakterystykę dawczyń przygotowano na podstawie danych gromadzonych w banku mleka w trakcie okresu współpracy. Charakterystykę biorców oparto na dokumentacji medycznej pochodzącej ze Szpitala im. Świętej Rodziny w Warszawie. Analiza składu mleka kobiecego została przeprowadzona dla każdej partii mleka przy użyciu analizatora MIRIS AB. Wyniki. W pierwszym roku działalności, współpracę nawiązało 45 dawczyń przekazując od 650 do 32030 ml mleka. Zawartość składników odżywczych w przekazanym pokarmie była zróżnicowana - białko 0,4-1,5 g / 100 ml, tłuszcz 1,7-7,4 g / 100 ml, węglowodany 6,3-7,9 g / 100 ml. Średnia długość żywienia biorców mlekiem z banku wynosiła 4 dni, średnia objętość mleka wykorzystanego do żywienia jednego noworodka wynosiła 282 ml. Wnioski. Profil dawczyń zarejestrowanych w banku ma istotny wpływ na skład pokarmu z banku mleka kobiecego. Rekrutacja jako dawczyń większej liczby matek noworodków przedwcześnie urodzonych oraz rozpoczynanie współpracy na wczesnym etapie laktacji, zaraz po jej stabilizacji, może podnieść wartość odżywczą mleka. W przypadku braku pokarmu biologicznej matki, natychmiastowe wdrożenie żywienia pokarmem z banku mleka jako krótkoterminowego wsparcia, może znacząco zredukować częstotliwość występowania nietolerancji pokarmowych u noworodków przedwcześnie urodzonych.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2017, 68, 4
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ kwasu taninowego i penicyliny na stabilność białek osierdzia
Influence of tannic acid and penicillin on pericardium proteins stability
Autorzy:
Turek, A.
Cwalina, B.
Pawlus-Lachecka, L.
Dzierżewicz, Z.
Powiązania:
https://bibliotekanauki.pl/articles/285712.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stabilizacja
białka osierdzia
stabilization
pericardium proteins
Opis:
Badano wpływ kwasu taninowego (TA) i/lub penicyliny (P) na efekt stabilizacji tkanek. W badaniach wykorzystano elektroforezę SDS-PAGE. Wykazano, że oddziaływanie TA lub P powoduje istotne zmiany profili elektroforetycznych białek uwalnianych z tkanek - w porównaniu z tkanką nie poddaną stabilizacji.
The influence of tannic acid (TA) and/or penicillin (P) on pericardium tissues stabilization effects have been examined. The SDS-PAGE electrophoresis was employed in the studies. It was shown that interactions of TA or P result in changes of electrophoretic profiles of proteins extracted from tissues as compared with non-stabilized tissue.
Źródło:
Engineering of Biomaterials; 2007, 10, no. 69-72; 84-86
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies