Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pasela, R." wg kryterium: Autor


Wyświetlanie 1-11 z 11
Tytuł:
Analiza wybranych czynników kształtujących zużycie wody w budynkach wielorodzinnych
Analysis of selected factors characterizing water consumption in multi-family buildings
Autorzy:
Pasela, R.
Gorączko, M.
Powiązania:
https://bibliotekanauki.pl/articles/1819022.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zużycie wody
budynki wielorodzinne
housing association
water consumption
Opis:
In the paper the water consumption level is correlated with some flats conditions. The study based on the 6 years data of more 500 comfortable flats located in multi-familiar buildings in Torun. The water consumption is hardly predicted, because belongs on many parameter, e.g. time, actual population and his periodical fluctuations, technical equipment, weather conditions meteorological. The individual habits, the organization of the day and the work mode are some important fast variable parameters too. The individual average factors for cold, hot and integral water consumption were estimated. The highest observed value was 228 dm3/Md (1 person in M-5 flat) and the minimal one 42 dm3/Md (6 person in M-3 flat). The average water consumption level recommended for projects are: 103 dm3/Md for M-5 flat, 90 dm3/Md for M-4, 89 dm3/Md for M-2 and at last 83,5 dm3/Md for M-2. The propositions are obviously less than the officially recommended (160 dm3/Md). The described time 6 years the water consumption in investigated urban area of Torun goes to stabilization on level 98 dm3/Md. The value was calculated on more 3500 observations. The gamma distribution can be applied for studies of the water consumption (cold, hot or global). The exponential model appears to be good for correlations of the flats occupations and water consumption level. The parameter values decreases to the flat occupation enhancement. The relations of water usage and a flat occupational level, it’s inside area and standard were estimated too. The increasing of the average individual flat area effects the water consumption too. The feature is confirmed by high values of correlation factors. Perhaps the flat existence needs some water volume, independently on flat occupation level. Presented investigations explain because the decreasing of flat occupation not effects by proper downing of the water consumption. The modeling of water consumption processes investigations appears to be suitable in urban projects, separately for the water requirement predictions.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 2; 1658-1672
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zastosowania w chłodnictwie fluorowanych gazów cieplarnianych na globalne ocieplenie klimatu
Impact refrigeration applications fluorinated greenhouse gases in global warming climate
Autorzy:
Okoński, R.
Pasela, R.
Powiązania:
https://bibliotekanauki.pl/articles/104367.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
klimat
globalne ocieplenie
efekt cieplarniany
F-gazy
climate
global warming
greenhouse effect
F-gases
Opis:
Zmiany klimatu na Ziemi w przeciągu wieków wywołane były różnymi przyczynami. Najistotniejsze z nich, między innymi, dotyczyły efektu cieplarnianego, wybuchu wulkanów o co za tym idzie emisji gazów (dwutlenku węgla, tlenki azotu, metan i innych) do atmosfery. Rozwój przemysłu spowodował większe stosowanie gazów w chłodnictwie początkowo zawierających chlor a obecnie F-gazów zawierający fluor. Dotyczy to wszystkich urządzeń chłodniczych w naszych domach. Wpływ tych gazów z grupy HCFH czy F-gazów jest różny na niszczenie warstwy ozonowej wokół Ziemi co z kolei wpływa na efekt cieplarniany a co za tym idzie na globalne ocieplenie.
Changes in the Earth's climate over the centuries were caused by different causes. The most important of them, among other things, related to the greenhouse effect, the explosion of volcanoes as a result of greenhouse gas (carbon dioxide, nitrous oxide, methane and others) into the atmosphere. The development of industry led to increased use of gas in refrigeration initially containing chlorine and now F-gases containing fluorine. The impact of these gases from the group HCFH or F-gases is different to the destruction of the ozone layer around the Earth, which in turn influences the greenhouse effect and hence global warming.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 2/II; 37-43
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Miejski staw jako odbiornik ścieków opadowych
Urban pond as a rainwater receiver
Autorzy:
Stachowski, P.
Oliskiewicz-Krzywicka, A.
Pasela, R.
Powiązania:
https://bibliotekanauki.pl/articles/400330.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
zlewnia zurbanizowana
staw
wody opadowe
retencja
infiltracja
urban catchment
pond
rain water
retention
infiltration
Opis:
W pracy przedstawiono funkcjonowanie stawu bezodpływowego, jako małego zbiornika retencyjnego w zlewni zurbanizowanej, znajdującego się na terenie dzielnicy Wilda w Poznaniu. Przedstawiono jego uwarunkowania przyrodnicze i glebowe oraz czynniki, warunkujące poziom zwierciadła wody w stawie. Szczególną uwagę zwrócono na rolę stawu jako odbiornika wód deszczowych. Określono zlewnię całkowitą oraz zlewnie cząstkowe. Na podstawie danych meteorologicznych obliczono dopływy wody do stawu o różnym prawdopodobieństwie wystąpienia. Przykład stawu w Parku Jana Pawła II pokazuje, że na obszarach miejskich zbiorniki o takim charakterze mogą być skutecznie wykorzystywane jako odbiorniki wód deszczowych, bez umniejszenia ich innych funkcji. Przyczyniają się do wzrostu zasobów wody podziemnej, zwiększają atrakcyjność rekreacyjną obszaru oraz stanowią cenny walor przyrodniczy. Jednak ciągła zabudowa terenów, uszczelnianie powierzchni gleby oraz występowanie ekstremalnych zjawisk pogodowych wymuszają kompleksowe spojrzenie na zagospodarowanie wód opadowych w miastach. Obliczenia wykazały, że największy dopływ ścieków opadowe wystąpiłby po deszczu 24-godzinnym i wyniósłby 3365 m3, a poziom zwierciadła wody w stawie podniósłby się o 0,25 m, a objętość stawu zwiększyłaby się o 7000 m3, co stanowiłoby około 57% całkowitej pojemności stawu. Gdyby wystąpił taki wzrost poziomu zwierciadła wody w stawie nie miałby on szkodliwego następstwa powodziowego. Dopiero wystąpienie deszczu 24-godzinnego o prawdopodobieństwie przewyższenia p = 10% i dopływie około 4700 m3, spowodowałoby całkowite wypełnienie wodą stawu. Wystąpienie takiej sytuacji można uniknąć, poddając staw odmuleniu, ponieważ obecnie zalega w nim muł o objętości około 1300 m3.
This paper presents the functioning of a closed pond as a small storage reservoir in the urban catchment area located in the Wilda district of Poznań. It presents the natural, hydro-geological and urban conditions and the factors conditioning the water level in the pond. Particular attention was focused upon on the pond as a rainwater receiver. The total catchment area and partial catchment area were determined. The inflow of water into the pond, with varying degrees of probability of occurrence, was calculated based on metrological data. The example of a pond in the John Paul II Park shows that this reservoir may be effectively used as rainwater receiver, without underestimating their other functions. They contribute to the increase of the underground water resources, increase the attractiveness of the recreational area and provide a natural value. However, the continuous urbanization, sealing the soil surface and the occurrence of extreme weather conditions necessitate a comprehensive look at the management of rainwater in urban areas. Calculations showed that the largest inflow of rain water occurs after a day’s rain with the probability p = 100%, and would amount to 3365 m3, and the water level in the pond would rise by only 0.25 m to a capacity of about 7000 mv. This represents 57% of the total capacity of the pond. If such an increase in the water level had occurred during the period of high water levels in the pond, it could not have damaging consequences of flooding. Only the occurrence of a day’s rain with the probability p = 10%, and capacity around 4700 m3, would completely fill the pond. Such a situation can be avoided by recultivation and desilting the bottom of the pond, where the slime collects with a capacity of 1300 m3.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 1; 1-8
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wyników pomiarów stężeń zanieczyszczenia powietrza pyłem PM10 i PM2.5 na stacji pomiarowej plac Poznański w Bydgoszczy
Analysis of the results of measurement of concentrations of air pollution with PM10 and PM2.5 measuring station square of Poznan in Bydgoszcz
Autorzy:
Pasela, R.
Milik, J.
Budzińska, K.
Szejniuk, B.
Powiązania:
https://bibliotekanauki.pl/articles/399519.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PM10
PM2.5
zanieczyszczenie powietrza
emisja zanieczyszczeń
emisja zanieczyszczeń monitoring
aglomeracja miejska
Bydgoszcz
air pollution
emission
monitoring
city agglomeration
Opis:
Zjawisko zanieczyszczenia pyłem zawieszonym PM10 i PM2,5 występuje w dużych aglomeracjach miejskich, gdzie głównym źródłem ich obecności jest komunikacja, co wiąże się przede wszystkim ze spalaniem paliw płynnych. Celem badań była ocena stanu zanieczyszczenia powietrza pyłem PM2,5 i PM10 dla wybranego obszaru miasta Bydgoszcz. Analizę przeprowadzono, wykorzystując dane pochodzące ze stacji monitoringu powietrza zlokalizowanej przy ul. Poznańskiej. Stacja jest własnością Wojewódzkiego Inspektoratu Ochrony Środowiska (WIOŚ) w Bydgoszczy. Badania wykazały, że najwyższe średnie dobowe stężenie pyłu wystąpiło w piątki i wynosiło odpowiednio 27,6 μg/m3 dla PM2,5 i 44,46 μg/m3 dla PM10. Zaobserwowano tendencję występowania wyższych wartości stężeń w sezonie grzewczym. Stwierdzono, iż średnie roczne stężenie pyłu zawieszonego (PM2,5 i PM10) w aglomeracji bydgoskiej jest bliskie przekroczenia poziomu dopuszczalnego ze względu na ochronę zdrowia ludzi.
The phenomenon of suspended particulate pollution PM10 and PM2.5 occurs in large urban areas where the main source of their presence is communication, which is primarily related to the combustion of liquid fuels. PM2.5 dust pollution is a major risk factor for diseases of the respiratory, cardiovascular, and allergy. Act regulating the standards and target dates for reducing concentrations of particulate matter in urban areas and in all the cities of over 100 thousand. residents of the Directive of the European Parliament and Council Directive 2008/50/EC of 21 May 2008. on ambient air quality and cleaner air for Europe (CAFE). The acceptable level of average daily concentration of PM10 is 50 μg/m3 and may be exceeded by not more than 35 times a year, while the level of allowable annual average concentration of 40 μg/m3. The aim of this study was to assess the state of air pollution of dust PM10 and PM2.5 for the selected area of the city of Bydgoszcz. The analysis was conducted using data from air monitoring stations located at Poznanska street. The station is owned by the Provincial Inspectorate for Environmental Protection (VIEP) in Bydgoszcz. The studies have shown that the annual average concentration of particulate matter analyzed station in Bydgoszcz in the years 2013–2015 amounted to PM10 41 μg/m3 PM2.5 and 23 μg/m3. The results are on the borderline of acceptable levels of concentration resulting from the Regulation of the Minister of the Environment of 2 August 2012. The concentrations of particulate matter in ambient air are strongly associated with meteorological conditions. The definitely higher concentrations observed in the autumn-winter season. The decrease in temperature causes the combustion in the boiler house of fuels with a high emissions. The highest average daily concentration of suspended particulate matter was observed on Thursday and Friday in the winter months, and while the lowest concentration was recorded in the summer months.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 1; 240-246
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hodowla stawowa karpia i jej wpływ na stan mikologiczny wód powierzchniowych
Breeding pond of carp and its effect on micological status of water
Autorzy:
Berleć, K.
Budzińska, K.
Pasela, R.
Stachowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/401435.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
karp
hodowla
wody powierzchniowe
zanieczyszczenie mikologiczne
carp
breeding
surface water
micological contamination
Opis:
Celem pracy była ocena wpływu hodowli stawowej karpia na mikologiczne zanieczyszczenie wód odprowadzanych do Noteci.. Badania przeprowadzono w Gospodarstwie Rybackim w Ślesinie. W celu oznaczenia liczby grzybów wodę pobierano na dopływie, w stawach produkcyjnych, zimochowach i na odpływie. Przeprowadzone obserwacje dowiodły, że hodowle stawowe mogą w nieznacznym stopniu redukować liczbę grzybów, jak również poprawiać niektóre parametry fizykochemiczne wody.
The aim of the study was to assess the impact of carp pond culture on mycological condition of surface waters. The study was conducted in a fish farm in Ślesin. To indicate the number of fungi the water was sampled at the tributary, ponds production and winter habitats and at the outflow. This study has shown that ponds may slightly reduce the number of fungi, as well as improve some physicochemical parameters of water.
Źródło:
Inżynieria Ekologiczna; 2015, 45; 135-139
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena składu fizyczno-chemicznego osadów ściekowych pochodzących z komunalnej oczyszczalni ścieków
Evaluation of the Physico-chemical Composition of Sludge from Municipal Sewage Treatment Plant
Autorzy:
Milik, J.
Pasela, R.
Szymczak, M.
Chalamoński, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818029.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osady ściekowe
skład chemiczny
metale ciężkie
substancja organiczna
oczyszczanie ścieków komunalnych
sewage sludge
chemical
heavy metals
organic material
waste waters treatment
Opis:
Municipal sewage sludge are a by-product of waste water treatment. The problems of sludge associated with the development of sludge require urgent solutions. Municipal sewage sludge may be used in agriculture in two forms: processed and unprocessed if they are stabilized and comply with acceptable levels of heavy metals and sanitation indicators and include the relevant product quantities of organic compounds and fertilizing nitrogen, phosphorus and potassium. Composition and quantity of sludge produced in the wastewater treatment process is different and depends on several parameters such as quality of waste water and processes for their purification. The presents shows an assessment of the physical and chemical sludge from sewage treatment plants selected and the results of research and analysis for the sludge collected from said object. Analysis of the results was carried out for possibilities to use sewage sludge for agricultural purposes. Sewage sludge derived from a sewage treatment plant mechanical-biological stabilization of sludge anaerobic digestion with a capacity of 26,400 m3. per day. The sediment samples were collected in the period from January to September 2015 year with a two-month interval. Attempts were subjected to microwave mineralization in a closed system in aqua regia. The heavy metal concentrations determined with a spectrophotometer Coupled Plasma emission ICP-OES Perkin-Elmer Optima 8000 detecting elements P, Ca, Mg, Pb, Cd, Hg, Ni, Zn, Cu, Cr. The collected sediment were determined: pH, dry weight of sediment, organic matter (marked as loss on ignition at 550 ° C), total nitrogen (Kjeldahl) and ammonium nitrogen. The results were compared with the limit values according to the law. It has been shown that the predominant heavy metals present in the sludge was copper and zinc, mercury was not detected. The value of organic matter sludge tested ranged from 49.36 to 63.15% of dry matter. The content of heavy metals in sediments was measured by reference to the existing provisions governing the use of natural sewage sludge. The contents of heavy metals were low and did not exceed the limit values in sewage sludge for their use in agriculture and land reclamation. The studied sediments were stable nature. The results indicate the good properties of the sludge, which can be used as organic fertilizer. It has been shown that the sludge produced in the study treatment did not exceed in any case permissible concentrations of heavy metals specified for sewage sludge used for agricultural purposes. The annual average content of heavy metals in the study period remained at a similar level. Understanding the composition of the physico-chemical sludge waste is the basis for the decision over their processing, use or disposal. The precipitate may be disposed by using thermal methods for combustion of solid comprising 90% of dry matter.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 579-590
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Usuwanie fosforanów z wykorzystaniem osadów potechnologicznych pochodzących ze stacji uzdatniania wody
Removal of Phosphates with Post-technological Sludge from Water Treatment Plant
Autorzy:
Totczyk, G.
Klugiewicz, I.
Pasela, R.
Górski, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/1818613.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osady z uzdatniania wody
osady pokoagulacyjne zawierające glin
defosfatacja
TZB
oczyszczalnia ścieków
water processing sludge
alumina water processing sludge
dephosphatation
RBC
sewage treatment plant
Opis:
With the treatment of water, especially surface waters, there is produced a high amount of sewage and sludge. They make up a serious ecology problem that due to a high volume and the content of sludge of iron or aluminium oxide-hydroxide or, pollution which occur in the intaken water (mineral and organic substances, algae, protozoa and bacteria) as well as the chemicals added. The environmental protection requires limiting materials as well as it makes you search for effective waste management problem-solving methods. The waste generated at present during water treatment most often undergo dehydration and drying and then they are deposited at the landfill site. The currently binding environmental protection law makes you look for the possibilities of the use of sludge as recycled materials, e.g. in brick factories, cement factories or with sewage treatment. Sludge containing aluminium or iron can be used e.g. in the process of municipal sewage treatment. The application of sludge containing aluminium for dephosphatation has the advantage of protecting the system from secondary release of precipitated phosphates in the environment deprived of dissolved oxygen. The possibilities of sludge application to remove phosphates differ, depend not only on the sludge characteristics but also on the sewage treatment process. The article demonstrates the results of research into using sludge derived from water treatment station in Lubicz to remove phosphates from sewage. At present the sludge after sedimentation and mechanical dehydration with the filtration press finally reaches the municipal landfill site. The sludge, applied for research, concentrated in settling vessels, is a mixture of post-coagulation sludge and washings from anthracite-sand and carbon filters. Its hydration accounting for 98,7% shows a high colour, above 80 mg Pt/dm3, it contains about 2,6 g/dm3 of aluminium as well as organic compounds expressed with BOD5 value equal 170 mg O2/dm3. The sludge shows a high COD of 3990 mg O2/dm3, and organic substance – for 31,6% of dry weight. The study of effectiveness of the removal of phosphates was made with the vessel test method. The sludge was dispensed at a changing volume from 0,5 to 100 cm3 per 1 dm3 of prepared water and then sewage. Both in water and in sewage there was recorded a 90% removal of phosphates by applying 80 cm3 of sludge per 1 dm3 of the sample. Additionally there was investigated the effect of dispensed sludge on the effectiveness of sewage treatment with the model of the treatment plant with rotating biological contactors. Applying the rate of 40 cm3 of sludge per 1 dm3 produced 96,0% elimination of COD, 97,7% removal of organic compounds characterised with the values of COD and BOD5 as well as 100% removal of phosphates. Finally it was found that it is possible to use the sludge to remove phosphates from sludge. During dephosphatation there was reported no use-up of the natural alkalinity of sewage. Sludge dispensing did not result in a decrease in the effectiveness of sewage treatment with the method of rotating biological contactors. The research is preliminary in nature and it needs to be continued.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 1660-1673
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Concentration of Trace Elements in Sewage Sludge From Wastewater Treatment Plant in Gniewino
Autorzy:
Milik, J.
Pasela, R.
Lachowicz, M.
Chalamoński, M.
Powiązania:
https://bibliotekanauki.pl/articles/124352.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
trace elements
heavy metals
sewage sludge
wastewater treatment plant
Opis:
The sewage sludge originating from wastewater treatment plants (WWTP) serving rural areas is suggested for agricultural or natural usage. However, sewage sludge is beforehand subjected to the several pre-treatments, which involve stabilization, hygienisation and pre-composting. These methods mainly decrease the amount of organic substances and the presence of microorganisms, but hardly affect the concentrations of heavy metals. The advantages of using sludges as fertilizer for improving and sustaining soil fertility and crop production are numerous. The addition of sewage sludge to soils could affect the potential availability of heavy metals. Trace elements are distributed in the soil in various forms: solid phases, free ions in soil solution, soluble organic-mineral complexes, or adsorbed on colloidal particles. The most undesirable heavy metals in sewage sludge that are toxic for the living organisms include: cadmium, chromium, nickel, lead and mercury. In the study, the concentrations of trace elements (Pb, Cd, Cr, Hg, Ni, Zn, Al, As, Se, B, Ba, Br, Ca, Cu, Fe, Mn, Na, Ga, Li, Mo, Sr, Mg, K, Ru, Tl, V, U) were tested in the sewage sludge obtained from a WWTP serving rural areas (PE< 9 000). In each case, the tested sewage sludge was meeting the criteria of stabilization and was used for agriculture and land reclamation purpose. All the samples were collected in 2016 and subjected to microwave mineralization in a closed system in aqua regia. The total amounts of macro and microelements were determined with a spectrophotometer Coupled Plasma emission ICP-OES. It was found that the total concentrations of trace metals in all of sewage sludges are the same as the Polish regulation limit of pollutants for sludge to be used in agriculture. European legislation is less restrictive and permits higher contents of heavy metals in sludge used for agriculture than Asia. The trace elements (cadmium: 1.16 mg·kg-1/d.m. in thePolish sewage sludge, are much higher than those in the other countries. Copper and zinc were the most prevalent elements observed (111.28 mg·kg-1/d.m. and 282.94 mg·kg-1/d.m., respectively). The concentrations of copper in the Polish sewage sludge are much lower (49–130 mg·kg-1/d.m.) than european sewage sludge (522–562 mg·kg-1/d.m.). The two of the tested heavy metals (beryllium, bismuth) were under the detection limit, while gallium, molybdenum, thallium, vanadium and silver were detected in the concentrations lower than 0.005 mg·kg-1/d.m. According to the obtained results, in all the tested samples, the total amount of trace elements, did not exceed the limit values in sewage sludge for their use in agriculture and land reclamation.
Źródło:
Journal of Ecological Engineering; 2017, 18, 5; 118-124
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wstępne rezultaty monitoringu warunków opadowych na terenie miasta Bydgoszczy w latach 2013–2014
The preliminary results of monitoring in terms rainwater in 2013–2014 in the city of Bydgoszcz
Autorzy:
Pasela, R.
Bohuszewicz, G.
Milik, J.
Budzińska, K.
Berleć, K.
Stachowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/399758.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
opad deszczu
natężenie deszczu
deszczomierz
Bydgoszcz
rainfall
rainfall intensity
rain gauge
Opis:
W artykule przedstawiono wstępne wyniki analiz rozkładu wysokości, intensywności i natężenia opadu deszczu na terenie miasta Bydgoszczy, na podstawie pomiarów sieci pluwiometrycznej eksploatowanej przez Miejskie Wodociągi i Kanalizacje w Bydgoszczy. System ten składa się z sześciu deszczomierzy korytkowych typu TPG-036-H24 firmy A-STER, wyposażonych w elektroniczny system zapisu danych z ich transmisją w technologii GPRS do serwera centralnego. Zapis wyników pomiaru wysokości opadów odbywa się w interwałach 2-minutowych z dokładnością do 0,1 mm. Poza tym analizie poddano ekstremalne wysokości i natężania opadów zarejestrowanych w badanym okresie, które zostały zaprezentowane w postaci tabel i wykresów. Pomiary natężenia i wysokości opadu prowadzone przy wykorzystaniu odpowiednio gęstej sieci pluwiometrycznej dają możliwość uzyskania wartościowych rezultatów, niezbędnych w analizie funkcjonowania miejskich systemów kanalizacyjnych.
The paper shows the results of analysis distribution of the amount and rainfall intensity in Bydgoszcz based on network measurements of rain, which is operated by the Municipal Water Supply and sewers in Bydgoszcz. The system consists of six rain-gauges type TPG-036-H24 by A-STER, which are equipped with electronic data recording system with GPRS transmission to a central server. A record of the amount of rainfall measurement results is carried out in 2-minute intervals with an accuracy of 0.1 millimeters. The extreme highs and the intensity of rainfall registered in the audited period was analyzed. The results were presented in a form of tables and graphs. The intensity measurements and the amount of rainfall were used by a dense network of rainwater, which allows you to get valuable results, essential in the analysis of the functioning of municipal sewer system.
Źródło:
Inżynieria Ekologiczna; 2015, 45; 176-182
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eliminacja bakterii nitkowatych w osadzie czynnym pod wpływem wybranych koagulantów i związków utleniających
Elimination of Filamentous Bacteria in Activated Sludge as Affected by Selected Coagulants and Oxidizing Compounds
Autorzy:
Budzińska, K.
Bochenek, M.
Traczykowski, A.
Szejniuk, B.
Pasela, R.
Jurek, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818564.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
bakterie nitkowate
osad czynny
eliminacja
koagulanty
związki utleniające
filamentous bacteria
activated sludge
elimination
coagulants
oxidizing compounds
Opis:
The activated sludge method is most frequently used at the stage of biological waste water treatment. The main reason for improper sludge sedimentation is the excessive growth of filamentous bacteria leading to disturbances in technological processes of sewage treatment plants, such as formation of swollen, flowing out sludge, foam transforming in to a thick surface scum, which consequently contributes to a decrease in the effectiveness of removing pollutions from sewage. There is a growing tendency to make attempts aiming at optimizing the chemical methods used to eliminate filamentous bacteria which often constitute a factor limiting proliferation of those bacteria. Accordingly, research was undertaken to estimate the effect of some iron and aluminum coagulants and oxidizing compounds (chlorine dioxide and sodium hypochlorite) on the elimination of filamentous bacteria in the activated sludge in the aspect of sewage treatment effectiveness. Activated sludge was collected from the mechanical and biological sewage treatment plant situated in the Kuyavian-Pomeranian voivodeship. The study was carried out using a laboratory biological reactor graduated to reflect the technological parameters of the sewage treatment plant. Analyses involved determination of physicochemical parameters (total suspensions, sludge volumetric index, sludge density index) and the microscopic evaluation of activated sludge (floc parameters, the composition of microfauna, the Sludge Biotic Index, the quantitative and species composition of filamentous bacteria). At the next stage of the experiment, water solution of iron chloride, water solution of polyaluminum chloride, chlorine dioxide and sodium hypochlorite were proportioned to the activated sludge. At the same time, samples of activated sludge were analyzed without chemical reagents. After a week, the effect of applied reagents on the quantitative and species composition of filamentous bacteria and the other components of activated sludge biocenosis was evaluated. It was proved that activated sludge subjected to analyses was characterized by poor sedimentation properties, resulted from the excessive proliferation of filamentous bacteria of which the most numerous, dominant group was the species Microthrix parvicella. Best effects of filamentous bacteria elimination were recorded after the use of aluminum coagulant, which selectively affected filamentous microorganisms, effectively limiting their excessive proliferation and at the same time not exerting the negative impact on the other organisms of activated sludge. The preparation affected favorable values of the Sludge Biotic Index, which did not substantially differ from that parameter in the control sample. Polyaluminum chlorite caused elimination of the bacteria Sphaerotilus natans and a considerable decrease in the numbers of type 0041micro-organisms. At the same time that preparation contributed to improving sedimentation properties of activated sludge flocs, as a result of which the volumetric index values were decreased in successive research samples, whereas the density index increased. The applied sodium hypochlorite contributed to the elimination of filamentous bacteria, and at the same time it slightly decreased the other parameters of activated sludge. It was indicated that chlorine dioxide contributed to a considerable decrease in diversity of activated sludge microfauna, causing a decrease in the number of crawling ciliates on the flocs and sedentary forms of those macroorganisms. Moreover an increase in the number of bacteriocidal free-floating protozoa and small flagellates resulted in a substantial decrease in the IBO value. The highest doses of reagent caused impoverishment of the biocenosis, which resulted in a decrease in the biotic index values by 7 units in relation to the control sample, activated sludge in those samples was qualified as IV class of sludge quality. The best effects in filamentous bacteria elimination were recorded after the use of aluminum preparation and chlorine compounds (chlorine dioxide, sodium hypochlorite).
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 1569-1586
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microbiological Contamination of Water in Fountains Located in the Ciechocinek Health Resort
Zanieczyszczenie mikrobiologiczne wody pochodzącej z fontann zlokalizowanych w uzdrowisku Ciechocinek
Autorzy:
Budzińska, K.
Pyrc, N.
Szejniuk, B.
Pasela, R.
Traczykowski, A.
Michalska, M.
Berleć, K.
Powiązania:
https://bibliotekanauki.pl/articles/1813904.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
water
fountains
contamination
bacteria
microscopic fungi
woda
fontanny
zanieczyszczenie
bakterie
grzyby mikroskopowe
Opis:
Fountains located in health resorts frequently serve as therapeutic waters intended for recreational and balneological purposes. Therefore, the quality of water and air around such objects is crucial for patients using the fountains. Fountain water conducive to the occurrence of pathogen microorganisms, such as: coliform bacteria, staphylococci, streptococci, Salmonella spp. and microscopic fungi. They mostly cause a gastrointestinal and skin infections. The research here presented aimed at the assessment of the degree of bacterial and fungal contamination of water samples taken from fountains located in the Ciechocinek health resort from the perspective of biosafety of tourists and patients. Microbiological analysis of the water sample was taken from four fountains (object A-D), one of which (object C) was supplied with brine water.The plate method was used to determination of a total count of bacteria and a total count of fungi in the water samples. For the quantitative determination of coliform bacteria, Escherichia coli, staphylococci and streptococci, the membrane filter technique was employed. The studies showed that the samples of water from fountains contained bacteriological and mycological contamination in which microfungi being the most abundant group. The water samples contained a few cells of E. coli, fecal streptococci and staphylococci. The most frequently indentified indicator bacteria in sample water from fountain D were faecal streptococci (3.17·101 cfu/100 ml). The water samples coming from the object B and D and in most water samples from the object C, there was no presence of these bacteria. As the data indicate, the largest differences regarding the population of those microorganisms were between water samples taken from Fountain B and C. The highest frequency of the occurrence of the E. coli bacilli was recorded in fountain A, while they occurred once in research series 5 taken from fountain C. The mean amount of these bacteria in the water samples taken from Fountain D was 5.76·100 cfu/100 ml, which was more than 40 times higher than the mean population of these microorganisms isolated from the water taken from Fountain C (0.14·100 cfu/100 ml). The studies demonstrate that the least number of coliform bacteria and E. coli was found in fountain C, where 4.51% brine water was used. The highest number of staphylococci during the entire research period was determined in water sample taken from fountain D (7.9·101 cfu/100 ml), while in water sample taken from fountains A and C and in sample from fountain B, no such bacteria were found. Occurrence of faecal bacteria, staphylococci and microscopic fungi in water may pose a risk of diseases for people who use the fountains. The research indicated that it is necessary to perform monitoring of fountain water and introduce legal regulations regarding its sanitary and hygiene condition.
Fontanny zlokalizowane na terenach uzdrowiskowych często są wykorzystywane jako wody lecznicze przeznaczone do celów rekreacyjnych oraz balneologicznych. W związku z tym bardzo ważna dla kuracjuszy korzystających z fontann jest jakość wody i powietrza wokół tych obiektów. Woda pochodząca z fontann sprzyja występowaniu mikroorganizmów chorobotwórczych takich jak: bakterie grupy coli, gronkowce, paciorkowce, pałeczki z rodzaju Salmonella oraz grzyby mikroskopowe. Powodują one przede wszystkim zakażenia o charakterze żołądkowo-jelitowym oraz infekcje skórne. Celem pracy była ocena stopnia zanieczyszczenia bakteriologicznego i mikologicznego próbek wody pobieranych z fontann, zlokalizowanych na terenie uzdrowiska Ciechocinek w aspekcie bezpieczeństwa sanitarnego turystów i kuracjuszy. Analizie mikrobiologicznej poddano próbki wody pobrane z czterech fontann (obiekty A-D), z których jedna (obiekt C) była zasilana wodą solankową. Metodą płytkową oznaczono ogólną liczbę bakterii i grzybów mikroskopowych. Do oznaczenia ilościowego bakterii grupy coli, Escherichia coli, paciorkowców kałowych oraz gronkowców wykorzystano metodę filtrów membranowych. W wyniku przeprowadzonych badań stwierdzono, że próbki wody pochodzące z fontann zawierały zanieczyszczenia bakteriologiczne i mikologiczne, przy czym najliczniej reprezentowane były grzyby mikroskopowe. W próbkach wody występowały pojedyncze komórki E. coli a także paciorkowce kałowe oraz gronkowce. Najliczniej paciorkowce kałowe identyfikowano w próbce wody pobranej z fontanny D (3,17·101 jtk/100 ml). W próbkach wody pochodzących z obiektu B i D oraz w większości próbek wody z obiektu C nie stwierdzono obecności tych bakterii. Największe różnice dotyczące liczebności tych mikroorganizmów wystąpiły w przypadku próbek wody pochodzących z fontanny B i C. W obiekcie A notowano najwyższą częstotliwość występowania pałeczek E. coli, natomiast w przypadku fontanny C występowały one w jednym przypadku w wody pochodzącej z 5 serii badawczej. Średnia liczba bakterii Escherichia coli w próbkach wody pobranej z obiektu D wynosiła 5,76·100 jtk/100 ml i była ponad 40-krotnie wyższa od średniej liczebności tych drobnoustrojów izolowanych z wody pochodzącej z obiektu C (0,14·100 jtk/100 ml). Badania wykazały, że najmniej bakterii grupy coli i E. coli stwierdzono w obiekcie C, w którym wykorzystywano wodę solankową o zasoleniu 4,51%. Największą liczbę gronkowców w ciągu całego okresu badań oznaczono w próbce wody pobranej z obiektu D (7,9·101 jtk/100 ml), natomiast w niektórych próbkach wody ujętej z obiektu A i C oraz B nie stwierdzono obecności tych bakterii. Występowanie w wodzie bakterii fekalnych, gronkowców, jak również grzybów mikroskopowych może stwarzać ryzyko zachorowań u ludzi korzystających z fontann. Przeprowadzone badania wskazują na konieczność prowadzenia monitoringu wody pochodzącej z fontann, a także na wprowadzenie regulacji prawnych dotyczących ich stanu sanitarno-higienicznego.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 181-199
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies