Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Palka, K" wg kryterium: Autor


Tytuł:
Structure and Thermoelectric Properties of Inconel 625/Pt Microjoint
Autorzy:
Boczkal, G.
Dadun, K.
Palka, P.
Hotlos, A.
Janoska, M.
Powiązania:
https://bibliotekanauki.pl/articles/355433.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
microjoint
thermocouple
microstructure
Opis:
A method of using the electric charge in a capacitor was applied for the manufacture of thermocouple micro-joints. The motivation for the study was the need to produce a stable welded connection without affecting the geometry of the substrate, which was a thin sheet of Inconel 625 alloy (UNS designation N06625). Within the framework of the research work, a suitable workstation for micro-joints elaboration was built and welding experiments were performed using different electric charges. Studies carried out within the framework of the present work have shown that joints based on Inconel 625 alloy and platinum have the best application properties in the range of small-scale temperature measurements. They can be used, e.g., for monitoring the temperature distribution on the inner surfaces of electric motor casings. An undeniable advantage is in this case the high thermal resistance of both materials used to produce the joint, i.e. the Inconel 625 alloy and platinum. This allows them to be used at high temperatures under atmospheric conditions.
Źródło:
Archives of Metallurgy and Materials; 2019, 64, 1; 197-200
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A model of strategic safety management in railway transport based on Jastrzebska Railway Company Ltd
Autorzy:
Wieczorek, S.
Pałka, K.
Grabowska-Bujna, B.
Powiązania:
https://bibliotekanauki.pl/articles/197142.pdf
Data publikacji:
2018
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
strategy
railway transport safety
strategia
bezpieczeństwo transportu kolejowego
Opis:
The article deals with the issue of railway transport safety from a strategic aspect. In turn, the concept of developing railway transport safety and the possibility of transferring model solutions to the economic field are presented. The article also focuses on highlighting the most significant criteria in terms of the development of railway safety. All stages in the realization of a relevant strategy are characterized, with a particular emphasis on the conditions for their efficient implementation.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2018, 98; 201-210
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics of Al-Fe sinters made by the powder metallurgy route
Charakterystyka spieków Al-Fe wytworzonych metodą metalurgii proszków
Autorzy:
Majchrowska, M.
Lasek, K.
Nowak, M.
Pałka, P.
Sułkowski, B.
Powiązania:
https://bibliotekanauki.pl/articles/264175.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
Al/Fe sinters
powder metallurgy
interface
intermetallic compounds
microstructure
spieki Al/Fe
metalurgia proszków
interfejs
związki międzymetaliczne
mikrostruktura
Opis:
The Al/Fe material was prepared by the powder metallurgy route with an additional intermediate stage which was a centrifuge of powder mixture. The application of the centrifuge stage was applied to obtain circular phase distribution of Al-rich phases in a sintered material. Iron powder with a particle size under 100 μm and aluminum powder with a particle size of about 25 μm, were used as starting materials. To determine the effect of centrifuging time on the distribution of Fe-Al particles, scanning electron microscopy (SEM, EDS) and XRD techniques were used. Microstructure observations show the influence of the centrifuging time on the distribution of Fe particles. It was observed that a longer centrifuging time caused changes in the ratio concentration of elements and allowed the growth of the intermetallic phase at the interface between solid Al and Fe particles.
Spiekane materiały Al/Fe wytwarzano metodą metalurgii proszków z wprowadzeniem etapu pośredniego w postaci odwirowania mieszaniny proszku. Etap wirowania miał na celu uzyskanie kulistego rozkładu faz bogatych w Al w spiekanym materiale. Proszek żelaza o wielkości cząstek poniżej 100 μm i proszek aluminium o wielkości cząstek około 25 μm zastosowano jako materiały wyjściowe. W celu określenia wpływu czasu wirowania mieszanki na rozkład faz w wytworzonym materiale zastosowano techniki skaningowej mikroskopii elektronowej (SEM, EDS) i dyfraktometrii rentgenowskiej (XRD). Obserwacje mikrostruktury wykazały istotny wpływ czasu wirowania na mikrostrukturę uzyskanych spieków. Zaobserwowano, że dłuższy czas wirowania spowodował zmianę stosunku stężenia pierwiastków i pozwolił na wzrost fazy międzymetalicznej na granicy faz między stałymi cząstkami Al i Fe. Badania mikrotwardości obszarów spiekanego materiału świadczą o zwiększeniu twardości w obszarach nowo utworzonych faz międzymetalicznych.
Źródło:
Metallurgy and Foundry Engineering; 2018, 44, 4; 195-203
1230-2325
2300-8377
Pojawia się w:
Metallurgy and Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of human serum on HAp-glucan composite
Autorzy:
Borkowski, L.
Lübek, T.
Jojczuk, M.
Nogalski, A.
Belcarz, A.
Pałka, K.
Hajnos, M.
Ginalska, G.
Powiązania:
https://bibliotekanauki.pl/articles/285218.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
biomaterials
bone tissue
regeneration
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 10
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Innovative macroporous chitosan/agarose matrix-based biomaterial for bone tissue engineering applications
Autorzy:
Kazimierczak, P.
Pałka, K.
Ginalska, G.
Przekora, A.
Powiązania:
https://bibliotekanauki.pl/articles/285776.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
biomaterials
bone tissue engineering
scaffolds
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 13
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Relationship of maximal isometric torque produced in flexors and extensors rate to technique by judo athletes
Autorzy:
Sterkowicz, S.
Lech, G.
Sterkowicz-Przybycień, K.
Chwała, W.
Ambroży, T.
Pałka, T.
Powiązania:
https://bibliotekanauki.pl/articles/307561.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
skład ciała
biomechanika
sport
athletic performance
body composition
biomechanics
martial arts
Opis:
Purpose: Development of strength is one of essential elements of motor preparation of judo athletes. The aim this study was to examine the influence of body composition and the joint torques on successful performance of various judo techniques. Methods: Twentyfive judo athletes participated in 175 judo bouts, which were video-recorded during the All-Polish competitions. Biomechanical classification of technical actions was used. The age and athletic experience of the subjects were 18 and 8.8 years, respectively. Their body height was 179.4 cm (Martin’s type anthropometer) and body mass was 80.3 kg (Sartorius F 1505 – DZA scales). Percentage of fat (10.6%) was estimated using skinfold result measurements. BMI (24.9 kgm–2), fat-free mass index (21.9 kgm–2) and fat mass index (3.0 kgm–2) were calculated. Maximum torques measured under static conditions were evaluated 2–3 days after the tournament. Descriptive statistics and ANOVA were conducted ( p 0.05). Results: Balancing of maximum torques in the muscles of the pelvic and illiac regions caused more frequent performance of physical lever-type throwing techniques, compared to couple of force-type throwing techniques. A negative correlation was found between body fat and value of force recorded for knee flexors and between the frequency of using techniques during groundwork and torques measured in hip extensors. High correlation of fat-free mass index and relative elbow flexor torque was found. Conclusions: The relationship between body composition and frequency of techniques used in a tournament, and joint torques developed by athletes were found.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 65-71
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ systemu utrzymania i rasy królików na wzrost, użytkowość rzeźną i parametry jakości mięsa
Effect of housing system and breed on growth, slaughter traits and meat quality traits in rabbits
Autorzy:
Palka, S.
Kmiecik, M.
Migdal, L.
Koziol, K.
Otwinowska-Mindur, A.
Bieniek, J.
Powiązania:
https://bibliotekanauki.pl/articles/843497.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Zootechniczne
Tematy:
kroliki
krolik termondzki bialy
krolik popielnianski bialy
utrzymanie zwierzat
warunki utrzymania
wzrost zwierzat
uzytkowosc rzezna
mieso krolicze
jakosc miesa
Źródło:
Roczniki Naukowe Polskiego Towarzystwa Zootechnicznego; 2018, 14, 4
1733-7305
Pojawia się w:
Roczniki Naukowe Polskiego Towarzystwa Zootechnicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Method to Produce Linearly Polarized Positrons and Positronium Atoms with the J-PET Detector
Autorzy:
Mohammed, Muhsin
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, ---
Skurzok, M.
Silarski, M.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1030045.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
41.75.Fr
41.75.Ht
77.22.Ej
36.10.Dr
85.75.Mm
87.57.uk
Opis:
A method for creating linearly polarized positrons and ortho-positronium (o-Ps) atoms with the J-PET detector is presented. The unique geometry and properties of the J-PET tomography enable one to design a positron source such that the quantization axis for the estimation of the linear polarization of produced o-Ps can be determined on the event by event basis in a direction of the positron motion. We intend to use ²²Na or other β⁺ decay isotopes as a source of polarized positrons. Due to the parity violation in the beta decay, the emitted positrons are longitudinally polarized. The choice of the quantization axis is based on the known position of the positron emitter and the reconstructed position of the positronium annihilation. We show that the J-PET tomography is equipped with all needed components.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1486-1489
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis Procedure of the Positronium Lifetime Spectra for the J-PET Detector
Autorzy:
Dulski, K.
Zgardzińska, B.
Białas, P.
Curceanu, C.
Czerwiński, E.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, Shivani
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033298.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.05.Kf
13.30.Ce
14.60.-z
78.47.-p
Opis:
Positron annihilation lifetime spectroscopy has shown to be a powerful tool to study the nanostructures of porous materials. Positron emission tomograph is a device allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the Jagiellonian PET will allow positron annihilation lifetime spectroscopy in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the Jagiellonian PET software. We compare its performance with the standard program LT 9.0 by using positron annihilation lifetime spectroscopy data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1637-1640
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of 6-week Nordic walking training on body composition and antioxidant status for women > 55 years of age
Autorzy:
Cebula, Agata
Tyka, Anna K.
Pilch, Wanda
Szyguła, Zbigniew
Pałka, Tomasz
Sztafa-Cabała, Katarzyna
Frączek, Barbara
Tyka, Aleksander
Powiązania:
https://bibliotekanauki.pl/articles/2161882.pdf
Data publikacji:
2017-05-08
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
Oxidative stress
women
antioxidants
Body Composition
health training
Nordic walking
Opis:
Objectives This study examined the effects of 6-week Nordic walking (NW) workout with individually customized intensity, on the body composition, and oxidative stress biomarkers for women > 55 years of age. Material and Methods Sixteen sedentary women (age 58.1±2.02 years old, body mass index (BMI) 26.74±2.72 kg/m²) worked out the NW 3 times/week over the 6-week period. Training intensity, which reflected the dominance of oxygen metabolism, was determined based on changes in physiological indicators during graded exercise on a treadmill (walking with poles). The body composition and oxidative stress biomarkers in blood were measured before and after the exercise routine. Results After the training period, body weight, body fat percentage, body mass index and uric acid levels in serum decreased significantly (p < 0.05). At the same time the plasma total antioxidant status increased considerably (p < 0.05), while the total oxidative status and the oxidized low-density lipoproteins concentration levels did not change significantly (p > 0.05). Conclusions Within a relatively short time, the Nordic walking with the customized intensity level focused on the dominance of fat metabolism, decreased body fat and improved the blood antioxidant defense system for previously sedentary women. Int J Occup Med Environ Health 2017;30(3):445–454
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 3; 445-454
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Human tissue investigations using PALS technique - free radicals influence
Autorzy:
Jasińska, B.
Zgardzińska, B.
Chołubek, G.
Pietrow, M.
Gorgol, M.
Wiktor, K.
Wysogląd, K.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Hiesmayr, B.
Jodłowska-Jędrych, B.
Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiktor, H.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057941.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
positron annihilation
positronium
free radicals
tissues
uterine leiomyomas
Opis:
The positron annihilation lifetime spectroscopy was applied to the samples of the human uterine leiomyomas and the normal myometrium tissues taken from the selected place of the uterus during a surgery. The method indicated differences in values of the measured positron annihilation lifetime spectroscopy parameters (lifetimes and intensities) between healthy and diseased tissue samples. The additional measurements were performed either in darkness or in presence of visible light which influenced the free radicals present in both kind of tissues and, as a result, made changes in free annihilation and o-Ps decay lifetime and intensity values.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1556-1558
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polymerization shrinkage of dental composites
Autorzy:
Pałka, K.
Zaszczyńska, A.
Kleczewska, J.
Powiązania:
https://bibliotekanauki.pl/articles/285764.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
dental composites
polymerization
tests
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 62
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies of J-PET detector spatial resolution
Autorzy:
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Alfs, D.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, M.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Shivani, -
Silarski, M.
Skurzok, M.
Sharma, N.
Sharma, S.
Shopa, R.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057928.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
87.57.uk
87.10.Rt
34.50.-s
Opis:
The J-PET detector, based on long plastic scintillator strips, was recently constructed at the Jagiellonian University. It consists of 192 modules axially arranged into three layers, read out from both sides by digital constant-threshold front-end electronics. This work presents preliminary results of measurements of the spatial resolution of the J-PET tomograph performed with ²²Na source placed at selected position inside the detector chamber.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1645-1648
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies on the effect of mill microstructure upon tool life during slot milling of Ti6Al4V alloy parts
Badania wpływu mikro stru ktury frezu na trwałość ostrza w proce sie frezowania ro wków w stopie tyt anu Ti6Al4V
Autorzy:
Kuczmaszewski, J.
Zaleski, K.
Matuszak, J.
Pałka, T.
Mądry, J.
Powiązania:
https://bibliotekanauki.pl/articles/1365733.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
stopy tytanu
frezowanie
zużycie
chropowatość powierzchni
titanium alloys
milling
wear
roughness
Opis:
Different forms of tool wear occur in the milling process. Mechanical wear, which has a range of varieties, is a typical form of wear connected with mill operating. One of the varieties of mechanical wear, frequently occurring during milling machiningresistant materials, is undesirable catastrophic wear. Avoiding that kind of wear by appropriate selection of technological parameters, sort of burning carbides and their microstructure constitutes basic information about reliability of the tool. This paper presents the findings from the experimental testing of the impact SC grain size in end mills on the cutting tool tooth (bit) service life and surface topography after slot milling Ti6Al4V alloy parts. The tool wear indicator was determined in compliance with PN-ISO 8688:1996. It was demonstrated that ultra fine grain SC milling cutters are the most resistant to chipping, whereas the surfaces machined with these cutting tools reveals the lowest roughness. The coarse grain SC milling cutters are among those with the shortest service life of all tested tools.
W procesie skrawania występują różne formy zużycia narzędzi. Zużycie mechaniczne, które ma szereg odmian, jest typową formą zużycia związaną z eksploatacją frezów. Jedną z odmian zużycia mechanicznego, często pojawiającą się podczas skrawania materiałów trudnoobrabialnych jest niepożądane zużycie katastroficzne. Unikanie tego rodzaju zużycia poprzez odpowiedni dobór parametrów technologicznych, gatunku węglików spiekanych oraz ich mikrostruktury stanowi podstawową informację o niezawodności narzędzia. W pracy przedstawiono wyniki badań doświadczalnych wpływu wielkości ziaren węglików spiekanych we frezach walcowo-czołowych na trwałość ostrza i topografię powierzchni po procesie frezowania rowków w stopie tytanu Ti6Al4V. Wskaźniki zużycia wyznaczono w oparciu o normę PN-ISO 8688: 1996. Wykazano, że frezy o strukturze ultradrobnoziarnistej są najbardziej odporne na wykruszenia, a powierzchnia po obróbce charakteryzuje się najmniejszą chropowatością. Najmniejszą trwałością charakteryzują się frezy o strukturze gruboziarnistej.
Źródło:
Eksploatacja i Niezawodność; 2017, 19, 4; 590-596
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time Calibration of the J-PET Detector
Autorzy:
Skurzok, M.
Silarski, M.
Alfs, D.
Białas, P.
Shivani, S.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033283.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.fb
36.10.Dr
11.30.Er
24.80.+y
Opis:
The Jagiellonian positron emission tomograph project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time-and high angular resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a ²²Na source and a small detector providing common reference time for synchronization of all the modules.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1641-1644
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies