- Tytuł:
- Development of a magnetic field monitoring system for the JAERI AVF cyclotron
- Autorzy:
-
Okumura, S.
Arakawa, K.
Fukuda, M.
Nakamura, Y.
Yokota, W.
Ishimoto, T.
Kurashima, S.
Ishibori, I.
Nara, T.
Agematsu, T.
Nakajima, T. - Powiązania:
- https://bibliotekanauki.pl/articles/148733.pdf
- Data publikacji:
- 2003
- Wydawca:
- Instytut Chemii i Techniki Jądrowej
- Tematy:
-
compensation coil
cyclotron
magnetic field - Opis:
- We have developed a probe of a nuclear magnetic resonance (NMR) magnetometer for measurement of a fluctuation of an AVF cyclotron field. The stability of the magnetic field of the JAERI AVF cyclotron, measured with the NMR probe, was within 1 × 10-5. A field-measurement accuracy of the order of 1 × 10-6 was achieved using a set of field-compensation coils and optimizing the probe position to obtain enough homogeneity of the magnetic field around the probe for measuring the cyclotron field with a high gradient. To eliminate a major bottleneck in the field measurement inside the cyclotron, the probe was specially produced with the cable shielding against RF noises and proper materials applied.
- Źródło:
-
Nukleonika; 2003, 48,suppl.2; 35-37
0029-5922
1508-5791 - Pojawia się w:
- Nukleonika
- Dostawca treści:
- Biblioteka Nauki