Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Nowińska, J." wg kryterium: Autor


Wyświetlanie 1-9 z 9
Tytuł:
New data on celestine-rich salts in the Wieliczka salt deposits
Autorzy:
Nowińska, J.
Powiązania:
https://bibliotekanauki.pl/articles/184740.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
rock salt
Badenian
Wieliczka
strontium
celestine
geochemistry
Opis:
Pale brownish celestine-rich salt rocks were found near the Franciuszek Müller gallery, in the chambers of the 3rd level in the Wieliczka Salt Mine. The complex of rock salts subjected to exploration occurred within a large seam approximately 15 m thick. Detailed research revealed that the salt has the form of a block incorporated within the gray salts body and being similar to other blocks of green salts, well known in the upper part of the deposit. A characteristic petrographical feature of the pale brown rock salt owed to the presence of celestine (SrSO 4 ). That strontium mineral was re-examined, using X-ray powder data, and scanning microscope observations, with EDS analysis. The investigated rock salts exhibited a mineral association of halite (main component), anhydrite, celestine, calcite, gypsum, clay materials, iron compounds and a small amount of bitumen. Interrigenous sediments and the insoluble part of salt occurred higher content of strontium that in halite. Celestine crystals were observed in two forms: elongated platy crystals, forming fan-shaped aggregates and granular aggregates, strongly associated with anhydrite. On carbonate and sulphate strontium usually appearing as needle shaped aggregates of celestine. No barium minerals were observed. The development and paragenesis of celestine suggested a post-sedimentary origin of these rocks that ought to be connected with diagenetic processes. An important observation that confirmed that thesis was the transformation of fine crystalline anhydrite into platy crystals, recrystallization and primary accumulation of strontium, as a result of evaporation processes.
Źródło:
Geology, Geophysics and Environment; 2017, 43, 1; 57-68
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inkluzje w mioceńskich solach potasowo-magnezowych w złożu Stebnik (zachodnia Ukraina)
Inclusions in the Miocene potassium - magnesium salts in the Stebnyk salt deposit (western Ukraine)
Autorzy:
Nowińska, J.
Powiązania:
https://bibliotekanauki.pl/articles/2192114.pdf
Data publikacji:
2015
Wydawca:
Polskie Stowarzyszenie Górnictwa Solnego
Tematy:
Stebnik
inkluzje
sole potasowo-magnezowe
miocen
zapadlisko przedkarpackie
Stebnyk
inclusions
potassium-magnesium salts
Miocene
Carpathian Foredeep
Opis:
Nagromadzenia soli potasowo-magnezowych w złożu Stebnik na Ukrainie występują w postaci odrębnych soczewek lub warstw o zaburzonym kształcie i często nieregularnym rozmieszczeniu. Miąższość eksploatowanych pokładów soli potasowo-magnezowej zmienia się od 4 m do 150 m. Kopalinę stanowi głównie minerały sylwinu, w złożach eksploatowano również karnalit, kainit i langbajnit. Występujące ponadto minerały to polihalit, epsomit, kizeryt. Do badań wykorzystano próbki pobrane na III poziomie kopalni Stebnik (Rudnik 1). Są to sole o barwie różowej zawierające polihalit, sylwin z dodatkiem anhydrytu i halitu. W czasie obserwacji mikroskopowych (w świetle przechodzącym i metodą spektroskopii Ramana), skupiono się przede wszystkim na kryształach halitu i powstałych w nich inkluzjach. Inkluzje w badanym materiale występują bardzo rzadko pojedynczo, zazwyczaj tworzą grupy, które posiadają specyficzne cechy, dzięki którym wyodrębniono ich trzy główne typy (ze względu na kształt): • Inkluzje wydłużone (podłużne) - tak zwane inkluzje młode, proces tworzenia się unkluzji został uchwycony dopiero co po zamknięciu się szczeliny. • Inkluzje eliptyczne - inkluzje uległy już wstępnym procesom przekształceń i zamykania, mają wyraźniej łagodny kształt i formę zbliżoną do elipsy. • Inkluzje kuliste - tak zwane inkluzje dojrzałe, które pod względem kształtu uzyskały formę idealną -została uzyskana najniższą energie swobodną. Badane inkluzje maja charakter inkluzji wtórych. Najczęściej są wypełnione kilkoma substancjami jednocześnie, przeważnie jest to materia organiczna, CO2 oraz hematyt. Dodatkowo w czasie szczegółowej analizy inkluzji zbadano wrostki chalkopirytu, hematytu oraz rzadszych minerałów minerałów takich jak lazuryt (Na,Ca)8[(S,Cl,SO4,OH)2 |(Al6Si6O24)], goethyt FeO(OH) czy anataz TiO2. Dane uzyskane w czasie badań porównano z archiwalnymi danymi (Kovalevich, 1979) i na tej podstawie ustalono spójny wniosek końcowy dotyczący mineralogii złóż.
The subject of research was salt deposit located in Stebnyk (Ukraine). In the Stebnyk salt mine is a very rich accumulation of potassium-magnesium salts, created in the Miocene basin of Carpathian Foredeep. Potassium-magnesium salts occur in the salt deposit as separate deformed lenses and layers often irregularly distributed. The thickness of the potassium-magnesium salts layer varies from 4 m to 150 m. The potash minerals are represented mainly by sylvite and carnallite, kainite and langbeinite, accompanied by polyhalite, epsomite and kieserite. Detailed mineralogical studies of Stebnyk salts area were carried out in the 70s (V. M. Kovalevich 1979). Currently, these data are correlated with the results obtained and on the basis of these data it has been determined the most reliable results. The inclusions are very rare one, usually form groups, which have specific characteristics by which managed to extract the four main types (due to the shape): inclusions elongated (oblong) - the so-called inclusions young, the process was captured just after the closing of the gap. • elliptical inclusions - inclusions were already pre-processes of transformation and closing, have clearly mild shape and form similar to an ellipse. • spherical inclusions - the so-called inclusions mature, which in terms of the shape of the desired form obtained from the point of force (the lowest free energy). Tested inclusions are secondary. Most are filled with several substances at the same time, usually the organic substance, CO2 and hematite. In addition, during the thorough analysis of the inclusions were examined inclusions of chalcopyrite, hematite and rare minerals such as lazurite (Na, Ca)8[(S, Cl, SO4, OH)2 | (Al- 6Si6O24)] and goethite FeO(OH) anatase TiO2.
Źródło:
Przegląd Solny; 2015, 11; 66--77
2300-9349
Pojawia się w:
Przegląd Solny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie nawłoci (Solidago Sp.) z siedlisk trudnych dla celów energetycznych
Use of goldenrod (Solidago Sp.) from difficult habitats for energy purpose
Autorzy:
Patrzałek, A.
Nowińska, K.
Kaszubkiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/113207.pdf
Data publikacji:
2016
Wydawca:
STE GROUP
Tematy:
nawłoć
Solidago Sp.
siedliska trudne
biomasa
wartość energetyczna
biogaz
goldenrod
difficult habitats
biomass
energy value
biogas
Opis:
Nawłoć (Solidago Sp.) skolonizowała większość nieużytków poprzemysłowych, będącymi siedliskami trudnymi. Pozyskiwanie nawłoci z siedlisk trudnych dla celów energetycznych jest zasadne z uwagi na: znaczne powierzchnie nieużytków poprzemysłowych opanowanych przez tę roślinę, jej długotrwałość na tego typu terenach, uzyskiwanie wysokich plonów biomasy zielonej bez większych nakładów, niską zawartość metali ciężkich w łodygach i liściach tej rośliny, wysoką wartość energetyczną Solidago Sp. oraz ilość pozyskiwanego z niej biogazu.
Goldenrod (Solidago Sp.) colonized most of the wasteland , which are difficult habitats. Acquisition of goldenrod from difficult habitats for energy purposes is justified for: large areas of wasteland dominated by this plant, its duration for such areas , getting high yields of green biomass without large expenditures, a low content of heavy metals in the stems and leaves of this plant, high energy value of Solidago Sp. and the amount of obtained biogas.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2016, 5 (17); 204-215
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of electrochemical impedance spectroscopy in analysis of SiO2 layer used for implants in bone surgery
Autorzy:
Walke, W.
Hyla, A.
Marciniak, J.
Nowińska, K.
Powiązania:
https://bibliotekanauki.pl/articles/284466.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
implants
bone surgery
morphological structure
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 113
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biocompatibility of oxidized anodically titanium alloys
Autorzy:
Szewczenko, J.
Marciniak, J.
Kajzer, W.
Antonowicz, M.
Nowińska, K.
Powiązania:
https://bibliotekanauki.pl/articles/284542.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
titanium alloys
biocompatibility
surface layer
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 38
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technological capabilities of surface layers formation on implant made of Ti-6Al-4V ELI alloy
Autorzy:
Kiel-Jamrozik, M.
Szewczenko, J.
Basiaga, M.
Nowińska, K.
Powiązania:
https://bibliotekanauki.pl/articles/306377.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
odporność korozyjna
infiltracja
stop tytanu
biomateriały
corrosion resistance
ion infiltration
metallic biomaterials
surface modification
titanium alloys
Opis:
Purpose: The aim of the presented research was to find a combination of surface modification methods of implants made of the Ti-6Al-4V ELI alloy, that lead to formation of effective barrier for metallic ions that may infiltrate into solution. Methods: To this end, the following tests were carried out: roughness measurement, the voltamperometric tests (potentiodynamic and potentiostatic), and the ion infiltration test. Results: The electropolishing process resulted in the lowering of surface roughness in comparison with mechanical treatment of the surface layer. The anodization process and steam sterilization increased corrosion resistance regardless of the mechanical treatment or electropolishing. The crevice corrosion tests revealed that independent of the modification method applied, the Ti-6Al-4V ELI alloy has excellent crevice corrosion resistance. The smallest quantity of ions infiltrated to the solution was observed for surface modification consisting in the mechanical treatment and anodization with the potential of 97 V. Conclusions: Electric parameters determined during studies were the basis for effectiveness estimation of particular surface treatment methods. The research has shown that the anodization process significantly influences the pitting corrosion resistance of the Ti-6Al-4V ELI alloy independent of the previous surface treatment methods (mechanical and electrochemical). The surface layer after such modification is a protective barrier for metallic ions infiltrated to solution and protects titanium alloy against corrosive environment influence.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 1; 31-37
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biokompatybilność modyfikowanego powierzchniowo stopu Ti6Al4V ELI badanego w SBF
Biocompatibility of surface modified Ti6Al4V ELI alloy tested in SBF
Autorzy:
Loska, S.
Szewczenko, J.
Tyrlik-Held, J.
Paszenda, Z.
Pochrząst, M.
Nowińska, K.
Powiązania:
https://bibliotekanauki.pl/articles/286165.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
biokompatybilność
biokompatybilność stopu Ti6Al4V ELI
stopy tytanu
biocompatibility
biocompatibility of Ti6Al4V ELI alloy
titanium alloy
Źródło:
Engineering of Biomaterials; 2011, 14, no. 106-108; 154-158
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion resistance of Ti6Al4V alloy coated with caprolactone-based biodegradable polymeric coatings
Odporność korozyjna stopu Ti6Al4V pokrytego biodegradowalnymi powłokami polimerowymi na bazie kaprolaktonu
Autorzy:
Kajzer, W.
Jaworska, J.
Jelonek, K.
Szewczenko, J.
Kajzer, A.
Nowińska, K.
Hercog, A.
Kaczmarek, M.
Kasperczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/1365372.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
corrosion resistance
metal biomaterials
Ti6Al4V alloy
biodegradable polymeric coatings
odporność korozyjna
biomateriały metalowe
stop Ti6Al4V
biodegradowalne powłoki polimerowe
Opis:
The aim of this study was to determine the influence of long-term exposure of Ringer’s solution on degradation of the anodically oxidated Ti6Al4V alloy coated with a biodegradable polymer coating. Polymeric coatings made of poly(glycolide-ε-caprolactone) – G-Cap and poly(glycolide- ε-caprolactone-lactide) – G-Cap-L were applied by a dip-coating method. Degradation was assessed on the basis of the results of pitting corrosion resistance and density of metal ions infiltrating to the solution. Studies were conducted for samples after 3, 6, 8, 10 and 12 weeks of exposure to the corrosive environment. In addition, topography of the surface of the polymer coating was assessed. As a result of potentiodynamic studies, the value of the polarization resistance and corrosion potential for the G-Cap and G-Cap-L coated samples were significantly decreased while simultaneous reduction of the density of metal ions infiltrating to the solution throughout the whole study period. There was also observed a faster degradation of the G-Cap coating compared to G-Cap-L, which showed local discontinuity after 12 weeks of exposure. The obtained results provide the basis for the development of polymeric coatings on surface of metal implants with predictable time / kinetics of degradation by selecting the composition of polymers while simultaneous limitation of metal ions infiltration into surrounding tissues.
Celem pracy było określenie wpływu długotrwałego oddziaływania rozworu Ringera na proces degradacji utlenianego anodowo stopu Ti6Al4V pokrytego powłoką biodegradowalnego polimeru. Powłoki polimerowe wykonane z poli(glikolido- ε-kaprolaktonu) – G-Cap oraz poli(glikolido ε-kaprolaktono- laktydu) – G-Cap-L naniesiono metodą zanurzeniową (dip-coating). Proces degradacji w funkcji czasu oceniano na podstawie wyników badań odporności na korozję wżerową oraz gęstości masy jonów metalowych przenikających do roztworu. Badania przeprowadzono dla próbek po 3, 6, 8, 10 i 12 tygodniach ekspozycji na środowisko korozyjne. Ponadto oceniano topografię powierzchni powłoki polimerowej. W wyniku przeprowadzonych badań potencjodynamicznych stwierdzono wyraźne obniżenie wartości oporu polaryzacyjnego i potencjału korozyjnego dla próbek z naniesionymi powłokami G-Cap i G-Cap-L przy jednoczesnym wyraźnym ograniczeniu gęstości jonów metalowych przenikających do roztworu w całym okresie badawczym. Stwierdzono również szybszą degradację powłoki typu G-Cap w porównaniu do G-Cap-L, dla której po 12 tygodniu ekspozycji stwierdzono lokalnie występujące przerwania ciągłości. Uzyskane wyniki dają podstawę do opracowywania na powierzchni implantów metalowych powłok polimerowych o przewidywalnym czasie/określonej kinetyce degradacji, poprzez dobór składu polimerów z jednoczesnym ograniczeniem możliwości przenikania jonów metalowych do otaczających tkanek.
Źródło:
Eksploatacja i Niezawodność; 2018, 20, 1; 30-38
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion resistance of PLGA-coated biomaterials
Autorzy:
Szewczenko, J.
Kajzer, W.
Grygiel-Pradelok, M.
Jaworska, J.
Jelonek, K.
Nowińska, K.
Gawliczek, M.
Libera, M.
Marcinkowski, A.
Kasperczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/306888.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
odporność korozyjna
stopy tytanu
stal nierdzewna
PLGA
corrosion resistance
titanium alloys
stainless steel
degradation
biodegradable coatings
Opis:
The aim of the study was to determine the influence of PLGA bioresorbable polymer coating on corrosion resistance of metal biomaterial. Polymer coating deposited by immersion method was applied. Corrosion resistance of metal biomaterials (stainless steel, Ti6Al4V, Ti6Al7Nb) coated with PLGA polymer, after 90 days exposure to Ringer’s solution was tested. The amount of metal ions released to the solution was also investigated (inductively coupled plasma–atomic emission spectrometry (ICP-AES) method). The surface of the samples was observed using atomic force microscopy (AFM) and scanning electron microscopy (SEM). Degradation of PLGA was monitored with the use of the 1 H NMR spectroscopy and GPC (Gel Permeation Chromatography). The studies were carried out for non-sterilized (NS) and sterilized (S) samples. Application of the polymer coating causes a reduction of release of metal ions to the solution. Depending on metal substrate different course of destruction of polymer layer was observed. After 90 days of incubation in Ringer’s solution polymer layer was highly degraded, however, the composition of copolymer (ratio of the comonomeric units in the chain) remained unchanged during the whole process, which suggests even degradation. The polymer layer reduced degradation kinetics of the metal substrate. Moreover, degradation process did not change surface morphology of metal substrate and did not disturb its integrity. The results obtained indicate that the applied polymer layer improves corrosion resistance of the alloys being investigated. Thus, the developed implants with bioresorbable coatings could be advantageous for medical applications.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 1; 173-179
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies