Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Nowakowska, Ewelina" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Thermophilic Co-Digestion of Sewage Sludge and Brewery Spent Grain
Autorzy:
Lebiocka, Magdalena
Montusiewicz, Agnieszka
Szaja, Aleksandra
Rembisz, Sylwia
Nowakowska, Ewelina
Powiązania:
https://bibliotekanauki.pl/articles/124244.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
anaerobic digestion
co-digestion
brewery spent grain
pre-treatment
milling
Opis:
This study examined the effectiveness of thermophilic co-digestion of sewage sludge and milled/non-milled brewery spent grain. The experiments were performed in batch-mode to evaluate both the biogas potential and the biogas production rate. Five runs were carried out, one of them concerned the anaerobic digestion of sewage sludge (as control), whereas the others referred to the co-digestion of sewage sludge with addition of milled and nonmilled brewery spent grain at doses of 5 and 10 g. The runs were conducted under thermophilic conditions (temperature 55±1°C) and lasted for 21 days. The effectiveness of the process was assessed on the basis of the volatile solids removal, biogas potential and the rate of biogas production. The physiochemical composition of reactor feed and digestate were characterized. The addition of the brewery spent grain resulted in increase of the biogas potential, but a decrease in the volatile solids removal. In the case of biogas production rate, the highest value was recorded in the run with the addition of 10 g of milled and non-milled brewery spent grain (0.69 Ndm3dm-3d-1). There was no observed influence of milling on the thermophilic co-digestion effectiveness since the parameters specified revealed comparable values.
Źródło:
Journal of Ecological Engineering; 2019, 20, 10; 118-124
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Assessment of the Occurrence of Benign Hypermobility Joint Syndrome in Physiotherapy Students
Autorzy:
Żyżniewska-Banaszak, Ewelina
Tchórzewska-Korba, Hanna
Gębska, Magdalena
Weber Nowakowska, Katarzyna
Leźnicka, Katarzyna
Żyżniewski, Kuba
Powiązania:
https://bibliotekanauki.pl/articles/1055102.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
Beighton score
hypermobility
joint
physiotherapy
score Brighton
sports
Opis:
The occurrence of connective tissue disorders is an important factor for development of occupational diseases in professions requiring a non-ergonomic and often static load of the musculoskeletal system. Symptoms of the connective tissue disorders appear at different ages. The diagnosis of hypermobility is an important problem due to the lack of uniform diagnostic criteria. The aim of this paper is to evaluate the incidence of joint hypermobility and its relation with a history of injuries and the level of physical activity in Physiotherapy students. The study involved 143 students (69% female, 31% male) aged 18 to 27 years (M = 20.7; SD = 1.43). The assessment of the occurrence of Benign Hypermobility Joint Syndrome (BHJS) syndrome was performed using the Beighton and Brighton scale. Among the surveyed students almost 82% of the women and just over 18% of the men fulfilled the diagnostic criteria for the diagnosis of hypermobility. A significant difference was also observed in the physical activity of the students. Among those who showed no signs of hypermobility exactly half of the participants trained sports as amateurs, while in the group of people with hypermobility the proportion was lower by nearly half. BHJS was not related to injuries and operations in the study group.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2017, 20, 4; 23-30
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie technik miniinwazyjnych w chirurgii zaćmy i witrektomii
The use of minimally invasive techniques in cataract surgery and vitrectomy
Autorzy:
Ozimek, Małgorzata
Nowakowska, Dominika
Gajda, Beata
Cisek, Ewelina
Wykrota, Agata
Chorągiewicz, Tomasz
Nowomiejska, Katarzyna
Rejdak, Robert
Powiązania:
https://bibliotekanauki.pl/articles/1928249.pdf
Data publikacji:
2016
Wydawca:
Medical Education
Tematy:
MICS
MIVS
fakoemulsyfikacja
witrektomia
zaćma
Opis:
W chirurgii okulistycznej od wielu lat dąży się do miniaturyzowania narzędzi oraz minimalizowania ran operacyjnych. Zastosowanie instrumentarium o małej średnicy w chirurgii zaćmy (cięcie od 1,8 do 2,2 mm) i witrektomii (23G, 25G i 27G) umożliwia wykonywanie małych cięć, co eliminuje szycie oraz skraca czas zabiegu, a następnie przyspiesza powrót do zdrowia po operacji. Nowe systemy operacyjne do witrektomii pozwalają na przeprowadzenie zabiegu chirurgicznego dużej szybkości cięć (7500/min) oraz umożliwiają łatwą zmianę pomiędzy modułem witrektomii i fakoemulsyfikacji. Rozwój nowych technik operacji zaćmy wymógł pojawienie się nowych narzędzi chirurgicznych, urządzeń do fakoemulsyfikacji, a także nowych soczewek wewnątrzgałkowych. Wyniki anatomiczne i funkcjonalne technik małego cięcia w witrektomii i operacji zaćmy są lepsze niż rezultaty zabiegów wykonywanych konwencjonalnymi technikami. Dodatkową korzyścią jest większe zadowolenie pacjentów.
Nowadays, there is a tendency in ophthalmic surgery of minimising of a diameter of tools and surgical wounds. The use of small diameter instruments for cataract surgery (1.8 to 2.2 mm of incision) and vitrectomy (23G, 25G, 27G) may result in smaller incisions, shorter treatment and faster recovery after the procedure. Thereby, to this day a lot of effort has been put in ophthalmic surgery to miniaturize surgical tools and to minimize area of the injury. New operating machines allow to perform high-speed cutting (7,500/min), and allow easy change between the module vitrectomy and phacoemulsification. Development of new techniques for the cataract surgery has necessitated the emergence of new surgical instruments, machine for phacoemulsification and new intraocular lenses. Anatomic and functional outcomes of microincision vitrectomy and cataract surgery have improved when compared to the procedures carried out by conventional techniques, an additional benefit is greater patient satisfaction.
Źródło:
OphthaTherapy; 2016, 3, 2; 116-123
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Współczesne możliwości korekcji prezbiopii pooperacyjnej metodami implantacji soczewek wewnątrzgałkowych u pacjentów z zaćmą
Postoperative presbyopia correction with intraocular lenses implantation in cataract patients – current trends
Autorzy:
Spyra, Mariusz
Cisek, Ewelina
Cisek, Agnieszka
Orkisz, Stanisław
Klonowski, Paweł
Chorągiewicz, Tomasz
Nowakowska, Dominika
Rejdak, Robert
Powiązania:
https://bibliotekanauki.pl/articles/1929139.pdf
Data publikacji:
2016
Wydawca:
Medical Education
Tematy:
soczewki o wydłużonej ogniskowej
soczewki wieloogniskowe
starczowzroczność
zaćma
Opis:
Obecnie najbardziej popularną metodą korekcji starczowzroczności podczas operacji zaćmy jest wszczepienie wewnątrzgałkowej soczewki wieloogniskowej. Pozwalają one na uzyskanie dobrego widzenia na różne odległości, ale nie są pozbawione wad, które powodują ich niewielki udział w rynku soczewek wewnątrzgałkowych – wynosi on mniej niż 5%. Największe wady soczewek wieloogniskowych to: możliwość występowania uciążliwych zjawisk świetlnych w nocy, obniżenie kontrastu i wysoki koszt. Obecnie głównym celem rozwoju technologii soczewek wewnątrzgałkowych jest uzyskanie równowagi między dużą niezależnością od okularów i dobrą ostrością widzenia na różne odległości a występowaniem i tolerancją niekorzystnych zjawisk świetlnych i obniżonego kontrastu. Duże zapotrzebowanie na zapewnienie widzenia pośredniego i bliskiego (40–80 cm) spowodowało największy rozwój i postęp technologii soczewek trójogniskowych i soczewek o wydłużonej ogniskowej. Równocześnie nowe rozwiązania optyki dyfrakcyjnej umożliwiają znaczną transmisję światła przy jego małej utracie dzięki konstrukcji dyfrakcyjnej. Bardzo dobry kontrast w warunkach zmierzchowych zapewnia korekcja aberracji chromatycznych. Uzyskanie wydłużonego ogniska dzięki dyfrakcyjnej konstrukcji echelette prowadzi do pozbycia się znacznej części uciążliwych nocnych zjawisk świetlnych. Wysoka jakość widzenia na różne odległości (dal, pośrednia, bliż) przy niskiej częstotliwości i natężeniu niekorzystnych efektów ubocznych pozwala na coraz szersze i bezpieczniejsze stosowanie tych rozwiązań u coraz większej liczby pacjentów operowanych z powodu zaćmy.
The most popular method of presbyopia correction during cataract surgery involves multifocal intraocular lens implantation. The MIOLs (multifocal intraocular lenses) constitute less than 5% of the intraocular lens market. With MIOLs patients can achieve very good distance, intermediate, and near vision, but very often accompanied by negative side effects. The most bothersome drawbacks of MIOLs include the night-light phenomena and low contrast sensitivity, mainly in low-light conditions. The main trends in MIOL technology developments involve achieving proper balance between good vision at all distances and spectacle independence, and lower contrast sensitivity and presence of negative light phenomena. Over the recent years, due to the changes to our lifestyle, intermediate vision (60–80 cm) has become very important, as has the development of trifocal and EDOF (extended depth of focus) lenses. New designs of diffractive lenses enable higher transmittance of light energy through the optics and the possibility of correcting the chromatic aberration which influences contrast sensitivity, especially in low light conditions. The echelette design makes it possible to eliminate the very disturbing night light phenomena thanks to the elongated focus. Nowadays, modern multifocal intraocular lenses allow patients to achieve very good vision at all distances after cataract surgery without troublesome side effects. And for that reason, multifocals can be used in a wider population of cataract patients, offering them high levels of satisfaction and spectacle independence.
Źródło:
OphthaTherapy; 2016, 3, 4; 270-278
2353-7175
2543-9987
Pojawia się w:
OphthaTherapy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies