Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Niewczas, A.M." wg kryterium: Autor


Tytuł:
Method of evaluation of degradation of bio-mechanical tooth-composite filling system
Metoda oceny degradacji systemu biomechanicznego ząb - wypełnienie kompozytowe
Autorzy:
Niewczas, A.
Pieniak, D.
Niewczas, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/329600.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
niezawodność
test laboratoryjny
kompozyt stomatologiczny
reliability
laboratory test
dental composite
Opis:
This paper describes a method of an enhanced life evaluation of dental fillings based on the observation of the enlargement of the marginal fissure between the filling and hard tissue of the tooth. A width of marginal fissure was considered as the functional parameter of the whole tooth-filling system in the conducted tests. In this study development of the fissure influenced by the cyclic changes of thermal loads was analyzed. The extracted human teeth were used in the tests. In which a model lesions with microhybrid composite fillings were applied. All tests were conducted on the dedicated test stand. After performance of fatigue tests, measurements of the width of marginal fissure were taken by means of SEM electron scanning microscope and optical microscope with computer image analyzer. On this basis a risk of functional unfitness of the tooth-filling system was estimated.
W artykule opisano metodę przyspieszonej oceny trwałości wypełnień stomatologicznych na podstawie obserwacji rozbudowy szczeliny brzeżnej pomiędzy wypełnieniem a twardą tkanką zęba. W warunkach prowadzonych badań jako miarę zdatności czynnościowej całego systemu ząb - wypełnienie przyjęto szerokość szczeliny brzeżnej. Autorzy przeprowadzili analizę rozwoju szczeliny pod wpływem cyklicznie zmiennych obciążeń cieplnych. Do badań wykorzystano usunięte zęby ludzkie. W zębach wypreparowano modelowe ubytki i założono wypełnienia z kompozytu mikrohybrydowego. Badania zostały przeprowadzone na specjalnie opracowanym stanowisku badawczym. Po wykonaniu testów zmęczeniowych przeprowadzano pomiary szerokości badanej szczeliny brzeżnej, wykorzystując elektronowy mikroskop skaningowy SEM. Na tej podstawie oszacowano ryzyko niezdatności użytkowej układu ząb - wypełnienie.
Źródło:
Diagnostyka; 2010, 2(54); 51-58
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zmęczenia cieplnego oraz starzenia na mikrotwardość kompozytów polimerowo - ceramicznych do zastosowań biomedycznych
Influence of thermal fatigue and ageing on the microhardness of polymer-ceramic composites for biomedical applications
Autorzy:
Pieniak, D.
Niewczas, A. M.
Kordos, P.
Powiązania:
https://bibliotekanauki.pl/articles/1366276.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
zmęczenie cieplne
starzenie
mikrotwardość
kompozytowe wypełnienia stomatologiczne
thermal fatigue
ageing
microhardness
dental composite fillings
Opis:
Badania prezentowane w niniejszej publikacji dotyczyły kompozytów polimerowo-ceramicznych stosowanych w stomatologii zachowawczej. Celem pracy była porównawcza ocena wpływu długotrwałego oddziaływania wilgotnego środowiska oraz cyklicznych obciążeń cieplnych na mikrotwardość nowego kompozytu bazującego na siloranach oraz dwóch tradycyjnych kompozytów bazujących na związkach metakrylanu. Próbki z kompozytów poddano oddziaływaniu środowiska soli fizjologicznej o cyklicznie zmiennych temperaturach (5°C i 65°C) wykorzystując specjalny symulator szoków termicznych. Wykonywano pomiary mikrotwardości metodą Vickersa przed rozpoczęciem testu zmęczenia cieplnego oraz po serii 4000 cykli termicznych. Wykazano, że w przeciwieństwie do tradycyjnych kompozytów stomatologicznych mikrotwardość kompozytu bazującego na siloranach nie zmniejsza się pod wpływem cyklicznego oddziaływania szoków termicznych odpowiadających warunkom fizjologicznym jamy ustnej. W warunkach przeprowadzonych badań stwierdzono nieznaczny wzrost tej mikrotwardości. Przeprowadzono również badania starzeniowe polegające na ocenie mikrotwardości próbek kompozytów przez okres 6 miesięcy. W tym okresie czasu próbki przechowywano w soli fizjologicznej. Pomiary mikrotwardości wykonywano po każdym miesiącu ekspozycji. Wykazano, że długotrwałe oddziaływanie środowiska soli fizjologicznej w warunkach stałej temperatury nie zmienia mikrotwardości żadnego z badanych materiałów.
Studies presented in this paper, concern polymer-ceramic composites applied in the conservative dentistry. The aim of the study was to evaluate a long-term impact of the humid environment and cyclic thermal loads on the microhardness of new silorane-based composites and two methacrylate-based composites. The composite samples were subjected to normal saline environment with cyclically variable temperatures (5°C and 65°C), using a special thermal shock simulator. Microhardness was measured with Vicker's method before the fatigue test and after a series of 4000 thermal cycles. It is known that microhardness of silorane-based composite in opposite to methacrylate-based composites not decrease under the influence of cyclic thermal loads. It was found slight increase of microhardness under conditions of conducted tests. The ageing studies were also conducted consisting in microhardness evaluation of the composite samples in 6 months period. During that time the samples were kept in normal saline. The studies of hardness were carried out after each month of the exposure time. No long-term impact of normal saline environment with constant temperature on the microhardness of the studied materials has been noticed.
Źródło:
Eksploatacja i Niezawodność; 2012, 14, 2; 181-188
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative study of wear resistance of the composite with microhybrid structure and nanocomposite
Autorzy:
Pieniak, D.
Walczak, A.
Niewczas, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/386486.pdf
Data publikacji:
2016
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
wear resistance
dental composites
microhardness
kompozyty stomatologiczne
kompozyty ceramiczno-polimerowe
odporność na zużycie
mikrotwardość
Opis:
The aim of the study was to compare microhardness and wear resistance of ceramic-polymer composites with micro and nanohybrid structure. For the studies commercial composites were used, containing filler particles of the same type but different sizes, nanosized (Filtek Ultimate) and micro-sized (Filtek Z250) composites. Tribological testing was conducted using ball-on-disc micro-tribometer. Vickers testing method was applied for microhardness studies with the use of Futertech FM 700 device. It has been demonstrated that the wear of Filtek Ultimate is almost twice lower in comparison to wear of Filtek Z250 composite. It has been concluded that the use of filler nanoparticles significantly increased wear resistance of the material. Additionally, lack of correlation between material microhardness and wear resistance has been demonstrated.
Źródło:
Acta Mechanica et Automatica; 2016, 10, 4; 306-309
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of recasting on the useful properties CoCrMoW alloy
Wpływ powtórnego przetapiania na właściwości użytkowe stopu CoCrMoW
Autorzy:
Walczak, M.
Pieniak, D.
Niewczas, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/301158.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
stopy kobaltu
trwałość aparatów protetycznych
powtórne przetapianie
cobalt alloys
durability of prosthetic devices
recasting
Opis:
Przetapianie uprzednio odlanego metalu może spowodować zmianę składu chemicznego nowopowstałego materiału, co w końcowym efekcie może oddziaływać na właściwości użytkowestopu stomatologicznego. Do badań zastosowano stop stomatologiczny CoCrMoW o nazwie handlowej Remanium 2001.Przygotowano 3 grupy stopu stomatologicznego przez zmieszanie 50% fabrycznie nowego stopu ze stopem po poprzednim przetopieniu. Grupę pierwszą odlano w 100% z nowego fabrycznie stopu jako grupę kontrolną (R1). Grupa druga (R2) została odlana z mieszaniny jednakowych ilości nowegostopu oraz stopu odlanego tylko raz. Grupa trzecia (R3) zawierała 50% świeżego stopu oraz stopu odlanego 2 razy.Wykonano analizę mikrostrukturalną oraz składu chemicznego, badania XRD, pomiary twardości, badania tribologiczne oraz badania przyczepności wg ISO 9693.Wykazano, że w odlewaniu należy używać nowego materiału a w przypadku wykorzystania materiału wcześniej używanego należy go wymieszać z materiałem nowym.Wykorzystanie procedury przetapiania może obniżyć koszty odlewów CoCrMoW oraz może być bezpieczne w stomatologii.
Recasting of the previously cast metal can change the chemical composition of the newly formed material, which ultimately could affect the properties of a dental alloy. The research used a dental alloy CoCrMoW trade name Remanium 2001. Three groups of dental alloy were prepared by mixing 50% fresh alloy to alloy remnants from previous castings. The specimens in the first casting group used 100% fresh alloy and served as control (R1). The second group consisted of equal amounts of fresh alloy and alloy remnants cast only once (R2). The third group contained 50% fresh alloy and alloy cast twice (R3). Microstructural analysis was performed and the chemical composition, XRD studies, hardness, and tribological test and the metal–ceramic bond strength was investigated according to ISO9693 standard. New material should be used in casting, and if previously casted material is used, it should be mixed with new material. The use of the recasting procedure can lower the costs of CoCrMoW castings and can be safely in dentistry.
Źródło:
Eksploatacja i Niezawodność; 2014, 16, 2; 330-336
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza niezawodnościowa wytrzymałości kompozytów stomatologicznych poddanych zróżnicowanym procedurom fotopolimeryzacji
Reliability analysis of strength of dental composites subjected to different photopolymerization procedures
Autorzy:
Niewczas, A. M.
Pieniak, D.
Ogrodnik, P.
Powiązania:
https://bibliotekanauki.pl/articles/1366268.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
niezawodność
wytrzymałość na zginanie
kompozyty stomatologiczne
fotopolimeryzacja
reliability
flexural strength
dental composites
photopolymerization
Opis:
Celem badań była ocena wpływu wybranych procedur fotopolimeryzacji na wytrzymałość i niezawodność kompozytów stomatologicznych opartych na siloranach oraz kompozytów opartych na związkach metakrylanowych w warunkach testu na 3-punktowe zginanie. Badano kompozyty o nazwach handlowych: Filtek Siloran (FSi), Gradia Direct Anterior (GDA), Gradia Direct Posterior (GDP), Herculite XRV (H). Zastosowano fotopolimeryzację dwoma rodzajami światła: lampą diodową oraz lampą halogenową. Przyjęto czas naświetlania 40 sek. oraz 60 sek. Do badań wytrzymałości został zastosowany test na zginanie trójpunktowe (TFS). Przygotowano próbki do badań w formie belek prostopadłościennych o liczności N = 20 z każdego materiału. Wyznaczono wartość średnią i odchylenie standardowe dla każdego badanego wariantu. Do oceny istotności różnic przeprowadzono analizę wariancji. Następnie wyniki każdej próby aproksymowano dwuparametrowym rozkładem Weibull'a. Obliczono parametr skali rozkładu (jako wytrzymałość charakterystyczną) oraz parametr kształtu (jako wskaźnik niezawodności materiału). Wykazano, że w warunkach testu na 3-punktowe zginanie rodzaj lampy nie ma wpływu na wytrzymałość w przypadku kompozytu opartego na siloranach, natomiast umożliwia poprawę jego niezawodności. W przypadku konwencjonalnych materiałów opartych na metakrylanach zastosowanie lampy diodowej w miejsce lampy halogenowej obniża wytrzymałość materiału, jednak zwiększa jego niezawodność. Ponadto wykazano, że zwiększenie czasu naświetlania - w przypadku materiału FSi i lampy halogenowej zwiększa jego wytrzymałość, natomiast nie ma wpływu na niezawodność. W pozostałych przypadkach wytrzymałość na ogół pozostaje na stałym poziomie lecz zwiększa się niezawodność materiału.
The aim of this study was evaluation of chosen photopolymerization procedures on strength and reliability of dental composites based on siloranes and composites based on methacrylate compounds in 3-points bending test conditions. The following composites were tested: Filtek Siloran (FSi), Gradia Direct Anterior (GDA), Gradia Direct Posterior (GDP), Herculite XRV (H). Photopolymerization was conducted by means of two types of light: LED lamp and halogen lamp. Exposure times of 40 and 60 seconds were applied. For the strength studies a three-point bending test was used (TFS). Twenty rectangular beam-shaped samples (N=20) from each material were prepared for the studies. For each studied case an average value and standard deviation were determined. To assess significance of differences a variation analysis was performed. Then, the results from each specimen were approximated by two-parameter Weibull distribution. Distribution scale parameter was calculated (as a characteristic strength) and shape parameter (as a material reliability index). It has been demonstrated that in 3-point bending test conditions in case of silorane-based composite the type of lamp has no impact on the strength, however it can improve its reliability. In case of conventional methacrylate-based materials application of LED lamp instead of halogen lamp reduces material strength, but increases its reliability. Additionally, it has been shown that the extension of exposure time - in case of FSi material and halogen lamp, increases material strength, however it has no impact on reliability of the material.
Źródło:
Eksploatacja i Niezawodność; 2012, 14, 3; 249-255
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza prawdopodobieństwa przetrwania i niezawodności układu ząb-wypełnienie kompozytowe
Analysis of survival probability and reliability of the tooth-composite filling system
Autorzy:
Pieniak, D.
Niewczas, A. M.
Niewczas, A.
Bieniaś, J.
Powiązania:
https://bibliotekanauki.pl/articles/301024.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
niezawodność
kompozytowe wypełnienie stomatologiczne
symulator żucia
obciążenia mechaniczne
reliability
laboratory tests
composite dental fillings
Opis:
Ocenie niezawodności poddano układ biomechaniczny ząb-wypełnienie kompozytowe (kompozyt polimerowy z mikrowypełniaczem). Próbki zębów z wypełnieniami wykonanymi na powierzchni żującej zębów poddano obciążeniom mechanicznym symulującym warunki środowiska jamy ustnej. Badania przeprowadzono w laboratorium na symulatorze żucia. Miarą zużycia wypełnień była szczelina brzeżna, którą oceniano w przekroju podłużnym zęba wykorzystując mikroskop optyczny oraz na powierzchni żucia, wykorzystując skaningowy mikroskop elektronowy (SEM). Wyniki pomiarów uporządkowano w zależności od strefy pomiaru szczeliny oraz w zależności od liczby cykli zmęczeniowych. Obliczano parametry rozkładu statystycznego rozmiarów geometrycznych szczeliny brzeżnej wykorzystując testy Kolmogorova-Smirnova oraz Shapiro-Wilka. Do oceny różnic wykorzystano analizę wariancji ANOVA oraz test post hoc. Wyznaczono przebieg funkcji niezawodności przyjmując model Weibulla. Oceniono ryzyko uszkodzenia oraz prawdopodobieństwo przetrwania badanego układu.
The bio-mechanical tooth-composite filling system (polymer composite with micro-filler) has been evaluated with respect to its reliability. The tooth specimens with prepared fillings on the tooth chewing surface were submitted to mechanical and thermal loads simulating natural conditions in the oral cavity. The research was carried out in the laboratory scale on the mastication simulator. A marginal fissure width was a measurement of the filling's wear, and it was investigated both in the longitudinal section with the use of optical microscope as well as on the chewing surface with the use of scanning electron microscope (SEM). The results of measurements were grouped according to the zone of the fissure measurement and to the number of fatigue tests performed. Statistical distribution parameters of geometrical size of the marginal fissure were calculated based on the Kolmogorov-Smirnov and Shapiro-Wilk tests. ANOVA variation analysis and post hoc test was used to assess the differences. The reliability function was determined with the use of Weibull model. The risk of damage and survival likelihood was evaluated introducing authors' criterion of the limit state of the tooth - filling system.
Źródło:
Eksploatacja i Niezawodność; 2011, 2; 25-34
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of photopolymerization parameters on the mechanical properties of polymer : ceramic composites applied in the conservative dentistry
Autorzy:
Pieniak, D.
Niewczas, A. M.
Walczak, M.
Zamościńska, J.
Powiązania:
https://bibliotekanauki.pl/articles/951821.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
kompozyt
materiał stomatologiczny
wypełnienie stomatologiczne
mikrotwardość
dental fillings
polymer-ceramic composites
flexural strength
microhardness
Opis:
In this paper the results of study of mechanical properties for four commercial polymer-ceramic composites applied in the conservative dentistry are presented, including one new silorane based composite and three standard composites based on methacrylate compounds. Influence of the type of light of diode and halogen polymerization lamps on the microhardness, flexural strength and elasticity were studied. Both exposed and unexposed specimens were taken into account. An exposure time was also differentiated (40 sec and 60 sec). Basic statistics of the analysed material parameters were determined. A post hoc test (Newman-Keuls) was performed in order to evaluate differences between microhardness of the studied materials, as well as Kruskal-Wallis test to evaluate differences in flexural strength and elasticity modulus of the material. It has been indicated that there is an impact of the type of lamp on the microhardness and flexural strength of composites with methacrylate matrix and lack of such impact in case of composites containing siloranes. Additionally, it has been found that an increase of photopolymerization time has a significantly different impact on the mechanical properties depending on the type of irradiated material.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 3; 29-35
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory studies of the influence of thermal cycling on anti-wear properties of composites used in biotribological friction PAIRS
Laboratoryjne badania wpływu cyklicznie zmiennej temperatury na właściwości przeciwzużyciowe kompozytów stosowa nych w biotribologicznych węzłach tarcia
Autorzy:
Walczak, A.
Pieniak, D.
Niewczas, A. M.
Gil, L.
Powiązania:
https://bibliotekanauki.pl/articles/188052.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polymer-ceramic composites
indentation hardness
scratch test
kompozyty polimerowo-ceramiczne
twardość indentacyjna
test zarysowania
Opis:
This paper presents the problems associated with changes in resistance to the tribological wear of light-cured polymer matrix ceramic composites (LC PMCCs) used in conservative dentistry and in dental prosthetics (fillings of carious cavities, dental bridges, structural reinforcements of the dental arch). Wear resistance of the surface layer of PMCCs depends on the time of exposure to the conditions of the oral environment, such as alternating temperatures and the exposure to liquids. The aim of the study was to assess changes in the mechanical properties of the surface layer under thermal cycling in liquid. Indentation hardness tests and scratch tests were performed before and after conditioning. Conditioning included 10,000 cycles of step temperature changes (10–70°C). The results of the scratch tests showed that universal composites that had relatively high filler contents were more resistant to scratching than flow type composites with lower filler contents. It was found that cyclic changes in ambient temperature reduced the wear resistance of universal composites but improved the resistance of flow type composites. In addition, in the case of flow type composites, the hardness of the surface layer was also increased.
W pracy zaprezentowano problematykę zmian odporności na zużycie tribologiczne światłoutwardzalnych kompozytów polimerowo-ceramicznych (LC PMCCs–light-cured polymer matrix ceramic composites) stosowanych w stomatologii zachowawczej oraz w protetyce stomatologicznej (wypełnienia ubytków próchnicowych w zębach, mosty stomatologiczne, wzmocnienia konstrukcyjne łuku zębowego). Odporność na zużycie warstwy wierzchniej PMCCs jest cechą zależną od czasu oddziaływania środowiska jamy ustnej, między innymi zmiennej temperatury i obecności płynów. Celem pracy była ocena zmian właściwości mechanicznych warstwy wierzchniej ze względu na cykliczne oddziaływanie płynów o zmiennej temperaturze. Badano twardość indentacyjną i ślad zarysowania przed i po kondycjonowaniu. Kondycjonowanie obejmowało 10 tys. cykli skokowej zmiany temperatury (10–70°C). Wyniki testu zarysowania wykazały, że materiały typu uniwersalnego o względnie dużej zawartości wypełniacza są bardziej odporne na zarysowania niż materiały typu flow o mniejszej zawartości wypełniacza. Stwierdzono, że cykliczne zmiany temperatury otoczenia zmniejszają odporność na zużycie kompozytów uniwersalnych, natomiast poprawiają odporność kompozytów typu flow. Ponadto w przypadku kompozytów typu flow obserwowano umocnienie warstwy wierzchniej polegające na wzroście twardości.
Źródło:
Tribologia; 2018, 280, 4; 143-149
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Probabilistic model for flexural strength of dental composites used in modeling reliability of the “tooth-dental composite” system
Probabilistyczny model wytrzymałości na zginanie kompozytów stomatologicznych w zastosowaniu do modelowania niezawodności układów "ząb – kompozyt stomatologiczny"
Autorzy:
Bartnik, G.
Pieniak, D.
Niewczas, A. M.
Marciniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/1365809.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
probabilistic modeling
reliability of tooth-dental composite system
dental composites
flexural strength
modelowanie probabilistyczne
niezawodność układów ząb-kompozyt stomatologiczny
kompozyty stomatologiczne
wytrzymałość na zginanie
Opis:
In the article the application of Bayesian probabilistic modeling was presented as a way to standardize analytics of measurement results, which completes the operational and procedural standardization of determining the strength of dental composites. The traditional way of conducting studies of strength performed as services and calculations, and which do not refer to previous studies, was changed into an adaptation process of knowledge accumulation in a form of an increasing precise models. Probabilistic flexural strength models were used to create a reliability ranking of studied dental composites. Conceptualization of reliability of a biotechnological system, such as a “tooth-dental composite” required the expansion of the notion of“failure” with random events involving the occurrence of compatibility failure.
W pracy przedstawiono zastosowanie bayesowskiego modelowania probabilistycznego jako sposobu standaryzacji opracowania wyników pomiarów, uzupełniającego standaryzację operatorowo – proceduralną wyznaczania wytrzymałości kompozytów stomatologicznych. Tradycyjny sposób prowadzenia badań wytrzymałościowych, wykonywanych usługowo i obliczeniowo nienawiązujących do badań poprzednich, zmieniono w adaptacyjny proces kumulacji wiedzy w postaci coraz dokładniejszych modeli. Probabilistyczne modele wytrzymałości na zginanie wykorzystano do utworzenia rankingu niezawodnościowego badanych kompozytów stomatologicznych. Konceptualizacja niezawodności układów biotechnologicznych takich jak „ząb – wypełnienie stomatologiczne” wymagała rozszerzenia zakresu pojęcia uszkodzenie o losowe zdarzenia polegające na zaistnieniu niezgodności pomiędzy komponentami układu biotechnologicznego (compability failure).
Źródło:
Eksploatacja i Niezawodność; 2016, 18, 1; 136-141
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fenomenologiczna ocena degradacji wypełnienia z kompozytu polimerowego i tkanki zęba w warunkach cyklicznych obciążeń dynamicznych
Phenomenological evaluation of degradation of polymer composite filling and the tooth tissue in the conditions of cyclical dynamic loads
Autorzy:
Pieniak, D.
Niewczas, A. M.
Bachanek, T.
Bieniaś, J.
Powiązania:
https://bibliotekanauki.pl/articles/285264.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
degradacja
szczelina brzeżna
kompozyt polimerowy
układ ząb-wypełnienie
degradation
marginal fissure
polymer composite
filling-tooth system
Opis:
W artykule opisano metodę oceny degradacji struktury zęba ludzkiego poddanego regeneracji kompozytem polimerowym opartym na związkach metakrylanowych. Za miarę degradacji przyjęto stopień zaawansowania procesów zużycia fizyko-mechanicznego odniesiony do granicznego poziomu tego zużycia. Analizowano szczelinę brzeżną oraz mikropęknięcia w warstwie brzegowej twardych tkanek zęba i w materiale wypełnienia. Wykazano, że laboratoryjna obserwacja rozbudowy szczeliny w wybranych obszarach anatomicznej struktury zęba (powierzchnia żucia, wypełnienie-szkliwo, wypełnienie-zębina) może być podstawą oceny stopnia degradacji całego układu ząb-wypełnienie. Przeprowadzono badania laboratoryjne, w których wykorzystano zęby ludzkie trzonowe i przedtrzonowe z wypełnieniami ubytków klasy I wg Blacka.
The article focuses on the method of degradation of the human tooth structure which was subjected to regeneration by polymer composite based on metacrylate compounds. The degree of advancement of physical and mechanical usage processes related to the limit level of this usage was considered as the measurement of degradation. The marginal fissure and micro-cracks in the border surface of the hard tooth tissues and in the filling material were analyzed. It was revealed that laboratory observation of the fissure expansion in selected areas of anatomical tooth structure (mastication surface, filling-enamel, filling-dentine) may constitute the basis of evaluation of degradation degree of the whole tooth-filling system. The laboratory tests were carried out in which human molars and premolars with the fillings qualified as class I according to Black were used.
Źródło:
Engineering of Biomaterials; 2011, 14, 103; 8-12
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prognozowanie trwałości wypełnień stomatologicznych na podstawie badań laboratoryjnych
Forecasting of dental fillings durability on the basis of laboratory evaluation
Autorzy:
Niewczas, A.M.
Pieniak, D.
Kordos, P.
Gardyński, L.
Powiązania:
https://bibliotekanauki.pl/articles/395190.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
prognozowanie trwałości
wypełnienia stomatologiczne
Opis:
W artykule opisano metodę prognozowania trwałości wypełnień stomatologicznych według kryterium zmęczeniowej propagacji szczeliny brzeżnej pomiędzy wypełnieniem a twardymi tkankami zęba. Szczelina brzeżna inicjowana jest poprzez skurcz polimeryzacyjny wypełnienia. Rozwój szczeliny jest wynikiem wielu zjawisk zużyciowych. Celem badań było określenie wpływu udarowych obciążeń mechanicznych (IC) oraz cyklicznych obciążeń termicznych - szoków termicznych (TC) na degradację szczelności wypełnienia stomatologicznego oraz wykazanie konieczności uwzględniania tego typu wymuszeń w przyspieszonych badaniach laboratoryjnych trwałości wypełnień stomatologicznych. Wykazano, że cykliczne szoki termiczne (TC) oraz udarowe obciążenia mechaniczne (IC) mają istotny wpływ na postęp degradacji wypełnienia. Wykazano również, że w badaniach in vitro wymuszenia tego typu nie mogą być pominięte. Precyzyjna ocena stanu wypełnienia, oparta na ocenie ilościowej, powinna uwzględniać pomiary nieszczelności w całym zakresie głębokości ubytku tzn. we wszystkich strefach styku wypełnienia z tkankami zęba a nie tylko przy powierzchni żucia.
The paper describes a method of forecasting durability of dental fillings according to the criterion of fatigue expansion (propagation) of the marginal gap between the filling and the hard tissue of the tooth. The marginal fissure is initiated by the polymer shrinkage of the filling. Development of the fissure results from a number of wear phenomena. The aim of the study was to evaluate the influence of impact mechanical loadings (IC) and thermal impact loadings (TC) on degradation of tightness of a dental filling as well as to provide evidence for the necessity of including this type of forces in accelerated laboratory tests of dental filling durability.It has been revealed that cyclical thermal shocks (TC) and impact mechanical loadings play a crucial role in degradation of the filling. In authors’ opinion, this type of forces shall be taken into consideration while performing In vitro tests. Accurate evaluation of the condition of teething, based on quantitative evaluation shall include the measurements of untightness in all contact zones between a filling and the tooth tissues, not only by the mastication surface.
Źródło:
Postępy Nauki i Techniki; 2010, 4; 172-185
2080-4075
Pojawia się w:
Postępy Nauki i Techniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of fibre reinforcement on selected mechanical properties of dental composites
Autorzy:
Niewczas, A. M.
Zamościńska, J.
Krzyżak, A.
Pieniak, D.
Walczak, A.
Bartnik, G.
Powiązania:
https://bibliotekanauki.pl/articles/306423.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
właściwości mechaniczne
włókno wzmacniające
kompozyty ceramiczno-polimerowe
mechanical properties
ceramic-polymer light-cured compceramicosites
fibre reinforcement
Opis:
For splinting or designing adhesive bridges, reconstructive composite structures with increased mechanical properties owing to embedded reinforcement fibres are used. The aim of this article was to determine the influence of glass and aramid fibres on the mechanical strength of composites reinforced with these fibres. Methods: Two polymer-ceramic microhybrid materials: Boston and Herculite were tested. Three types of reinforcement fibres were used: aramid (Podwiązka) with a single layer weave, a single layer weave glass fibre (FSO) and triple layer weave glass fibre (FSO evo). Tests were conducted in accordance with the requirements of ISO 4049:2009. The following material types were chosen for research: Boston, Boston + Podwiązka, Herculite, Herculite + Podwiązka, Herculite + FSO and Herculite + FSO evo. The scope of research included: flexural strength B, bending modulus of elasticity εB and work to failure of the reinforced composite Wfb. Additionally, microscopic observations of fracture occurring in samples were made. Results: In comparison: the Herculite (97.7 MPa) type with the Herculite + FSO evo (177.5 MPa) type was characterized by the highest strength. Fibre reinforcement resulted in decreasing the elasticity modulus: Herculite + reinforcement (6.86 GPa; 6.33 GPa; 6.11 GPa) in comparison with the Herculite (9.84 GPa) and respectively Boston + reinforcement (10.08 GPa) as compared with the Boston (11.81 GPa). Conclusions: Using glass fibres increases flexural strength of the test composites. Using aramid fibres does not change their strength. The elasticity modulus of the reinforced reconstructive structures decreases after application of either type of fibres. However, their resistance to the crack initiation increases.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 2; 3-10
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikroskopowa ocena przylegania brzeżnego wypełnień w zębach stałych
Microscopic evaluation of the marginal adhesion of the fillings in permanent teeth
Autorzy:
Walczak, M.
Niewczas, A.
Powiązania:
https://bibliotekanauki.pl/articles/285708.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
wypełnienia stomatologiczne
dental fillings
Opis:
Prezentowana praca dotyczy badań szczelności brzeżnej wypełnień z amalgamatu srebra oraz kompozytu światłoutwardzalnego w warunkach laboratoryjnych (in vitro). Do badań wykorzystano zęby ludzkie trzonowe i przedtrzonowe usunięte ze względów ortodontycznych, w których wypreparowano ubytki klasy I wg. Blacka. Próbki zębów z założonymi wypełnieniami poddano zaprogramowanym cyklom obciążeń mechanicznych na specjalnie zbudowanym urządzeniu testującym, stymulującym fizjologiczny tor ruchu żuchwy. Następnie oceniano obszar połączenia materiału wypełnienia z tkanką twardą zęba na mikroskopie skaningowym. Na każdej próbce stwierdzono obecność szczeliny brzeżnej wynoszącej od kilku do kilkunastu mim.
The presented work deals with the study of the marginal tightness of the amalgam and light-setting composite fillings in laboratory conditions (in vitro). Human molars and premolars extracted due to orthodontic reasons were used in the study. In those teeth the class I cavities according to Black's classification were prepared. The tooth specimens with fillings were submitted to the programmed cycles of mechanical loads in the specially designed investigation station simulating the physiological trajectory of the mandible. The next stage constituted the scanning microscopic evaluation of the area of the bond between the filling material and hard tissue. The presence of an edge fissure of the size from a few to a dozen or so mim was observed in each specimen.
Źródło:
Engineering of Biomaterials; 2007, 10, no. 69-72; 87-89
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozwój szczeliny brzeżnej jako efekt zmęczenia cieplnego wypełnień stomatologicznych
Increasing of marginal gap in thermocycled restoration system
Autorzy:
Pałka, K.
Gruszecka, M.
Niewczas, A.
Powiązania:
https://bibliotekanauki.pl/articles/284368.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
cykliczne obciążenia cieplne
mikroprzeciek
szczelina brzeżna
kompozyty stomatologiczne
thermocycling
microleakage
marginal gap
restorative composite
Opis:
Mikroprzeciek jest główną przyczyną występowania próchnicy wtórnej w okolicy wypełnień stomatologicznych. W pracy badano wpływ cyklicznych obciążeń cieplnych na rozwój szczeliny brzeżnej dla 2 nanohybrydowych materiałów kompozytowych w wypełnieniach klasy I w ludzkich zębach trzonowych. Po każdych 2000 cykli (do 20000) próbki były oceniane na mikroskopie stereoskopowym stosując metodę penetrantu. Pomiarów długości szczeliny brzeżnej dokonano z wykorzystaniem systemu analizy obrazu. Uzyskano wyniki pomiarów długości szczeliny brzeżnej w zależności od ilości cykli termicznych. Wzrost szczeliny brzeżnej może być opisany wielomianem 3 stopnia, a szybkość rozwoju szczeliny zależy w szczególności od rodzaju systemu wiążącego oraz od interakcji między materiałami, właściwości powierzchni tkanek oraz od wpływu warunków w jamie ustnej.
Microleakage is a major factor contributing to the occurrence of secondary carious lesions around restorations. This study investigated the effect of thermocycling on microleakage of 2 selected nanohybrid composite Class I restorations in human molars. After every 2000 thermocycles (till 20000 thermocycles) specimens were examined by stereomicroscopy using a dye penetration test. The marginal gap was measured using image analysis software. As a result the length of marginal gaps in dependence of number of thermocycles was presented. Increasing of marginal gap may be described by 3rddegree polynomial line and the velocity of marginal gap growth depends especially on adhesive system, and also on interactions between materials, physical properties of the tissue interface and the influence of the oral environment.
Źródło:
Engineering of Biomaterials; 2011, 14, 104; 23-27
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of friction force determination method on results obtained from model of gas flow from combustion chamber to the crankcase
Autorzy:
Koszałka, G.
Niewczas, A.
Guzik, M.
Powiązania:
https://bibliotekanauki.pl/articles/245664.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
combustion engine
blowby
piston ring
friction force
mathematical model
Opis:
The paper presents investigation of the influence of the friction force calculation method on the results of simulations run with the use of the model ofgas flow from the combustion chamber to the crankcase and piston rings motion in the grooves. The first series of simulations was run using the gas flow and ring motion model in which the friction force was calculated from the empirical equation. The second series was run with the use of the gas flow and ring motion model fully integrated with the ring lubrication model. In that case the friction force was derived from the hydrodynamic model of ring lubrication. Comparison of the results obtained in the first and second series of simulations indicated that despite the fact that the friction forces calculated with these two methods differed considerably, the method of friction force calculation had insignificant effect. This refers to the ąuantities determined in the simulations which are most important from practical point of view - i.e. displacements of the rings in the grooves, pressure courses in inter-ring regions and blowby rate. It is not necessary to integrate the gas flow and ring motion model with the model of ring lubrication, and doing so to complicate it very much, if the aim of the calculations is simulation of blowby and rings behaviour in the grooves.
Źródło:
Journal of KONES; 2009, 16, 4; 223-239
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies