Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Muc, Adam" wg kryterium: Autor


Tytuł:
Capabilities of local and remote monitoring and control of equipment used in marine ship industry
Autorzy:
Albrecht, Agata
Muc, Adam
Powiązania:
https://bibliotekanauki.pl/articles/27315873.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
maritime devices
redundancy
remote control
local control
PLC
urządzenia morskie
redundancja
zdalne sterowanie
sterowanie lokalne
Opis:
This article presents two aspects regarding marine equipment control and monitoring. The first one is the issue of remote and local control in the maritime and land industry. The second is the economical and efficient use of redundant devices. This article describes the structure of remote control implemented on vessels. Paper presents an idea of control that combines remote and local control to provide optimal use of redundant devices with simultaneous increase of system reliability. The whole concept is shown on the built physical model with the control and operator panels. The control was implemented using freely programmable controller and HMI panel.
Źródło:
New Trends in Production Engineering; 2018, 1, 1; 135-141
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Centralne zarządzanie oprogramowaniem stanowisk laboratoryjnych na bazie systemu PiNet i komputerów Raspberry Pi
Central management of laboratory workstations’ software based on PiNet system and Raspberry Pi computers
Autorzy:
Muchowski, Tomasz
Muc, Adam
Szeleziński, Adam
Powiązania:
https://bibliotekanauki.pl/articles/266927.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
Raspberry Pi
sieciowe uruchamianie
PXE
PiNet
systemy operacyjne
network booting
operating systems
Opis:
W pracy przedstawiono metodę tworzenia infrastruktury laboratoryjnej pozwalającej, za pośrednictwem serwera, na sieciowe uruchamianie (ang. network booting) różnych programów na stanowiskach laboratoryjnych. Prezentowana metoda wykorzystuje oprogramowanie PiNet do stworzenia instancji systemu operacyjnego Raspbian na serwerze. Metoda ta wykorzystuje także odpowiednio przygotowane jednostki startowe (ang. boot file) umieszczane na kartach pamięci w komputerach typu Raspberry Pi. Dzięki tej konfiguracji, zaraz przy uruchomieniu, urządzenia te łączą się z serwerem i użytkują serwerową instancję Raspbiana. Dla każdego użytkownika pracującego na urządzeniach przygotowywane jest osobne konto, co pozwala na jednoczesną pracę wielu użytkowników w trybie multi-user-mode.
The paper presents a metod of creating laboratory infrastructure that allows network booting from a laboratory server. This method uses PiNet software to create a single Raspbian OS instance on the server. By putting network boot files on Raspberry Pis memory cards, it allows Raspberry Pis to use the single Raspbian OS instance that was placed on the server. For every user working on the Raspberry devices there is a user account created. This metod allows multiple users to be logged in at the same time in spite of having only one instance of Raspbian OS. Having only one instance of Raspbian OS makes configuring the laboratory infrastructure easier. The Raspbian placed on the server can be chrooted at any moment to install additional applications, execute bash scripts or edit configuration files. Properly configured Raspbian can be used |to teach programming, networking and managing databases. Moreover Raspbian can be used as a terminal that uses SSH to work on a server ex. to execute queries on PostgreSQL server.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 65; 95-100
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stosowanie QOS wraz z PCQ w laboratoriach uczelnianych w celu nadzorowanego współdzielenia dostępu do laboratoryjnych serwerów przez studentów
Using QOS with PCQ in university laboratories in order to enhance students access to laboratory servers
Autorzy:
Muchowski, Tomasz
Muc, Adam
Szeleziński, Adam
Powiązania:
https://bibliotekanauki.pl/articles/267520.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
QOS
PCQ
sieć
laboratorium
priorytetyzacja
współdzielenie zasobów
networking
laboratory
prioritizing
sharing resources
Opis:
W pracy przedstawiono metodę konfiguracji sieci lokalnej na potrzeby laboratoriów komputerowych. Zastosowano QoS (ang. Quality of Service) z PCQ (ang. Per Connection Queueing) w celu zapewnienia studentom dostępu o równej przepustowości do serwerów laboratoryjnych. Metoda ta umożliwia zarówno priorytetyzację konkretnego ruchu sieciowego, ograniczanie przepustowości do konkretnych, z góry ustalonych wartości, jak i gwarantowanie prędkości transferu na poziomie przepływności pozostałych użytkowników. Metoda ta jest skalowalna i możliwa do zastosowania w większości routerów programowalnych.
The paper presents a method of configuring the computers laboratiories’ local network. The QOS with PCQ was used in order to guarantee an equal bandwith for students connecting to laboratories’ servers. This method allows both prioritizing specific type of network traffic, limiting bandwith to pre-established values and guarantiing the same bandwith for every user. This metod is scalable and can be applied by using most of programmable routers. A basic configuration of QoS with PCQ that made clients get equal bandwith was presented in the second chapter. This configuration consisted of one parent query that created a structure in which sub-queries configured with PCQ were placed. The third chapter showed a configuration that pioritized traffic on specific port (port 22) above other taffic. This configuration was also configured with PCQ to share the bandwith equaly for every client that made prioritized traffic. In order to create the configuration, firewall mangle rules were created to mark connections (upload and download) and to mark packets (packets send or received on port 22 and packets not send or received on this port). The marks were used to allow QoS to select the packets that were ment to be prioritized and give them the highest priority. In collaboration with PCQ the configuration prioritized port 22 traffic while splitting the bandwith equaly amongst clients.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 65; 87-94
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostic benchmarks on dynamic characteristics of thin-walled marine damaged structures
Autorzy:
Szeleziński, Adam
Murawski, Lech
Muc, Adam
Powiązania:
https://bibliotekanauki.pl/articles/2064867.pdf
Data publikacji:
2019
Wydawca:
STE GROUP
Tematy:
thin-walled structures
welded joints
SHM
spectrum analysis
damping decrement
Opis:
Among structural health monitoring (SHM) methods of thin-walled structures, a vibrodiagnostic method is one of the most promising. The accelerometer recorded responses provide diagnostic information that requires mathematical processing to extract the essential dynamic characteristics. The authors have been looking for new parameters - diagnostic benchmarks which can be applied to non-destructive, automatic testing of thin-walled marine structures (especially their welded joints) like ship hulls. All characteristics have been based on recorded data generated during the vibration tests of welded joints with and without failures. For this purpose, the authors proposed method based on: FFT windowing analysis, benchmark with using 2D or 3D time – frequency dynamic characteristics and the determination of damping decrement in function of time. The work presents the algorithm and exemplary results obtained from the application of proposed method to several selected sample plates with different type of welds.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2019, 2, 1; 38--52
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Znaczenie symulacji komputerowych w nauczaniu energoelektroniki
The Importance of Computer Simulation in Teaching of Power Electronics
Autorzy:
MYSIAK, PIOTR
MUC, ADAM
ALBRECHT, AGATA
Powiązania:
https://bibliotekanauki.pl/articles/457598.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Rzeszowski
Tematy:
energoelektronika
badania symulacyjne
power electronics
simulation studies
Opis:
Energoelektronika jest jednym z ważniejszych przedmiotów, których uczą się przyszli inżynierowie elektrycy. Wymaga on od studentów znajomości różnych dziedzin techniki. Przedmiot ten w zakresie praktycznym charakteryzuje się dużymi wymaganiami odnośnie do zapewnienia właściwych warunków nauczania, wysokimi kosztami realizacji, drogim i specjalistycznym sprzę-tem laboratoryjnym. Ze względu na przedstawione problemy w nauczaniu złożonych układów energoelektronicznych wymaga się stosowania badań symulacyjnych. Nie każdy program symulacyjny, zwłaszcza stosowany wcześniej w elektronice, można wykorzystać w energoelektronice. W opracowaniu pokazano przykłady praktycznego wykorzystania badań symulacyjnych oraz korzyści i ograniczenia, jakie niosą one ze sobą.
The power electronics is one of the most important subjects for future electrical engineers. It is a difficult subject requiring from students the knowledge of: circuit theory, electronics, energy, electric drive and control theory. The complex systems of power electronics require simulation studies in the teaching process. Not every simulation program, previously used in electronics, can be used in power electronics. One of the recommended programs is the PSIM, which includes interface library tailored to the needs of the user and power electronics. The paper presents exam-ples of practical use of the simulation program and the benefits and limitations eventuate from its use.
Źródło:
Edukacja-Technika-Informatyka; 2017, 8, 2; 102-110
2080-9069
Pojawia się w:
Edukacja-Technika-Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Line start permanent magnet synchronous motor supplied with voltage containing subharmonics
Autorzy:
Gnaciński, Piotr
Muc, Adam
Pepliński, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/29521037.pdf
Data publikacji:
2023
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
interharmonics
line start permanent magnet synchronous motor
power quality
subharmonics
voltage fluctuations
vibration
Opis:
The presented study examines the effect of voltage subharmonics, which relates to components of the frequency less than the fundamental voltage harmonic, and the currents and vibration of the line start permanent magnet synchronous motor. The obtained experimental results corresponded to a production motor with a rated power of 3 kW and a rated speed of 1500 rpm. The main purpose of our study was to highlight that the subharmonic value had a non-linear effect on the vibration level of the considered motor. It was found that for subharmonic values up to approx. 0.5% of the vibration level could be considered acceptable for long-term operation, whereas vibration caused by voltage subharmonics of values greater than approx. 0.8% might promote machine damage.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2023, 74 (146); 28-34
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Containerization of Server Services
Autorzy:
Muc, Adam
Muchowski, Tomasz
Zawadzki, Albert
Szeleziński, Adam
Powiązania:
https://bibliotekanauki.pl/articles/2064877.pdf
Data publikacji:
2020
Wydawca:
STE GROUP
Tematy:
remote work
server services
containerization
server costs
docker
Opis:
Businesses are increasingly confronted with server-related problems. More and more, businesses are enabling remote working and need to rely on network services. The provision of network services requires rebuilding the network infrastructure and the way employees are provided with data. Web applications and server services use common dependencies and require a specific network configuration. This often involves collisions between network ports and common dependencies’ configuration. This problem can be solved by separating the conflicting applications into different servers, but this involves the cost of maintaining several servers. Another solution may be to isolate applications with virtual machines, but this involves a significant overhead on server resources, as each virtual machine must be equipped with an operating system. An alternative to virtual machines can be application containerization, which is growing in popularity. Containerization also allows to isolate applications, but operates on the server’s native operating system. This means eliminating the overhead on server resources present in virtual machines. This article presents an example of web application containerization.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2020, 3, 1; 320--330
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Use of Undervolting to Reduce Electricity Consumption and Environmental Impact of Computers
Analiza wykorzystania undervoltingu do redukcji zużycia energii elektrycznej w urządzeniach komputerowych i oddziaływania na środowisko
Autorzy:
Muc, Adam
Muchowski, Tomasz
Kluczyk, Marcin
Szeleziński, Adam
Powiązania:
https://bibliotekanauki.pl/articles/1811735.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
undervolting
energy saving
electric energy
power consumption
generated heat
processor
oszczędzanie energii
energia elektryczna
pobór prądu
generowane ciepło
procesor
Opis:
This paper presents a method of lowering the processor’s voltage and temperature in which the computer operates by performing an operation called undervolting. By using undervolting it is possible to reduce electricity consumption and the amount of heat generated by computer workstations by up to 30%. This problem is particularly relevant for institutions that use a large number of computers. The more the computers are subjected to the higher computational load, the more effective the mechanism of undervolting is. Undervolting the processor does not reduce its performance, but lowers its operating temperature, has a positive impact on its life span and power consumption. Maintaining a low temperature of operation for computer hardware is essential to reduce operating and repair costs. The paper also presents the results of environmental research aimed at assessing the validity and effectiveness of undervolting.
W pracy przedstawiono metodę obniżania napięcia procesora i temperatury pracy komputera poprzez wykonanie operacji zwanej undervoltingiem. Przez zastosowanie undervoltingu można obniżyć nawet o 30% zużycie energii elektrycznej i ilość wydzielanego ciepła przez stanowiska komputerowe. Problem ten jest szczególnie istotny w przypadku instytucji, które korzystają z dużej liczby komputerów. Skuteczność mechanizmu jest tym większa im komputery poddane undervoltingowi są bardziej obciążone obliczeniowo. Wykorzystywanie undervoltingu w konfiguracji procesora nie zmniejsza jego wydajności, a obniża jego temperaturę pracy, wpływa pozytywnie na jego żywotność i zużycie energii elektrycznej. Utrzymanie dobrej kultury pracy sprzętu komputerowego jest kluczowe, by obniżyć koszty eksploatacji oraz napraw. W pracy przedstawiono również wyniki badań środowiskowych, których celem była ocena zasadność i efektywności stosowania undervoltingu.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 2; 791-808
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Long-term Analysis of the Operation of the Urban Heating Network Including Aspects of Environmental Protection
Długoterminowa analiza eksploatacji miejskiej sieci ciepłowniczej z uwzględnieniem aspektów ochrony środowiska
Autorzy:
Muc, Adam
Szeleziński, Adam
Lizakowski, Piotr
Noch, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/1811763.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
heating network
network monitoring
heat network malfunctions
environmental protection
pre-insulated networks
sieć ciepłownicza
monitoring sieci
awarie sieci ciepłowniczych
ochrona środowiska
sieci preizolowane
Opis:
The article presents methods for the location of leakages in heating pipelines. The advantages and disadvantages of each of the described methods are presented. The exploitation and modernization of the actual heating network in the city of up to 30,000 inhabitants over the space of 10 years have been characterized. The examined heating network was analyzed for the degree and categories of malfunctions occurring in the examined time space in the network and impact on the natural environment was determined. The article also examines the impact of various factors, such as the amount of make-up water, the amount of heat required to heat the supplementary carrier, the total cost of heat to replenish the carrier, networks total disruption and the amount of water exchange in the system and its impact on the natural environment. At the same time, an assessment of the impact of the modernization of the heating network combined with its munition to reduce the impact of these factors on environmental protection was made.
W artykule przedstawiono metody lokalizacji nieszczelności rurociągów ciepłowniczych. Przedstawiono wady i zalety każdej z opisanych metod. Scharakteryzowano eksploatację i modernizację rzeczywistej sieci ciepłowniczej w mieście do 30 tysięcy mieszkańców na przestrzeni 10 lat. W badanej sieci ciepłowniczej przeanalizowano stopień i kategorie awarii występujących w badanej przestrzeni czasu w sieci oraz określono ich wpływ na środowisko naturalne. W artykule zbadano również oddziaływanie rożnych czynników, takich jak: ilość wody uzupełniającej, ilość ciepła do podgrzania nośnika na uzupełnienie, koszt łączny ciepła przeznaczony do uzupełnienia nośnika, zład łączny sieci oraz ilość wymian wody w systemie i jej wpływ na środowisko naturalne. Równolegle, podjęto ocenę wpływu modernizacji sieci ciepłowniczej, połączonej z jej uzbrojeniem, na zmniejszenie oddziaływania wymienionych czynników na ochronę środowiska.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 1; 330-342
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ensuring Equal Bandwidth for Remote Connections to the Local Company Server
Autorzy:
Muc, Adam
Muchowski, Tomasz
Kluczyk, Marcin
Szeleziński, Adam
Powiązania:
https://bibliotekanauki.pl/articles/2064809.pdf
Data publikacji:
2020
Wydawca:
STE GROUP
Tematy:
QOS
PCQ
bandwidth sharing
VPN
remote work
Opis:
Creating the required IT infrastructure to enable the ability for comfortable remote working is not an easy task. Improper configuration can create the possibility of taking over the whole bandwidth of the link by one device. Increasing bandwidth introduces extra costs and does not completely eliminate the problem – it will be more difficult to take over the whole bandwidth, but it is still possible. The solution to the problem may be the use of clouds and VPS, but it is associated with high costs and the need to entrust company data to providers of these services. Due to security and too high costs, this may not be an optimal solution. An alternative solution may be to use QoS along with PCQ. This mechanism allows to ensure equal division of the bandwidth between the devices under its control. With an appropriate configuration, QoS can eliminate the problem of taking over the whole bandwidth and ensure equal access to resources.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2020, 3, 1; 285--295
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies