Tytuł:
A helical-coil resonator magnetically coupled with microstrip transmission line for EPR spectroscopy
Nowe kompozyty grubowarstwowe o obniżonej temperaturze spiekania przeznaczone na kontakty ogniwa słonecznego
Autorzy:
Mossakowski, M.
Koprowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/192291.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Materiałów Elektronicznych
Tematy:
rezonator EPR
sprzężenie magnetyczne
rezonator helikalny
EPR spectroscopy
microstrip circuits
microwave resonators
Opis:
This simple resonator consists of silver wire formed as coil of two turns. Compared to cavity resonators working in the same frequency band, our resonator is substantially smaller - 0.8 mm inner diameter and 0.2 mm wire diameter (AWG of 32). The coil is suspended over the microstrip supply line which is connected to EPR spectrometer. The whole apparatus is an X band EPR probe for biological tissue research. The main advantage of our project in this simple construction of the probe is the convenient resonator's coupling and supplying RF power by a microstrip line. Simulations and real measurements of electromagnetic field distribution revealed impressive symmetry and an enormous magnetic field concentration along resonator's main axis where tissue samples are placed. The A factor for this resonator is over 20Gs/√W. Analysis of resonance circuit shows a very wide resonance band (small quality factor - about 300). This is the desired feature in pulse EPR spectroscopy.
Opisany rezonator zbudowany został ze srebrnego drutu o średnicy 0.2 mm uformowanego w dwuzwojową cewkę o wewnętrznej średnicy 0.8 mm. W porównaniu do rezonatorów wnękowych pracujących w tym samym zakresie częstotliwości, przedstawiony rezonator helikalny stanowi niewielki ich ułamek objętości. Cewka jest zawieszona nad linią mikropaskową podłączoną do mostka mikrofalowego spektrometru EPR. Rezonator zbudowany został z przeznaczeniem do badań uwodnionych próbek biologicznych w paśmie X. Głównym zamierzeniem autorów było udoskonalenie sprzężenia rezonatora z mikropaskową linią zasilającą. Przeprowadzone symulacje i rzeczywiste pomiary rozkładu pola elektromagnetycznego ujawniły dużą symetrię i olbrzymią koncentrację pola magnetycznego wzdłuż głównej osi rezonatora, w miejscu gdzie znajduje się badana próbka. Współczynnik A dla opisanego rezonatora przewyższa wartość 20 GS/√W, natomiast pasmo rezonansowe jest bardzo szerokie - mała dobroć układu - 300. Powyższe cechy rezonatora są pożądane w impulsowej spektroskopii EPR.
Źródło:
Materiały Elektroniczne; 2009, T. 37, nr 4, 4; 3-8
0209-0058
Pojawia się w:
Materiały Elektroniczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Łazienkowski Bridge fire in Warsaw – structural damage and restoration method
Pożar na Moście Łazienkowskim - uszkodzenia konstrukcji i ich konsekwencje
Autorzy:
Zobel, H.
Karwowski, W.
Wróbel, M.
Mossakowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/231451.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pożar
Most Łazienkowski
pomost ortotropowy
metoda geodezyjna
niweleta
pionowość dźwigarów
fire
Łazienkowski Bridge
orthotropic deck
surveying method
formation line
girder verticality
Opis:
On the 14th of February, 2015, a huge fire broke out on Łazienkowski Bridge; a five span bridge, 423 m long and 28 m wide, built in the years 1972-74. It was a fully steel structure with four plate girders and orthotropic deck. The fire started under the first span during the replacement of wooden service decks. The next day, the Department of Bridges of the Warsaw University of Technology was designated to conduct an expertise material investigation, geometrical verification, and FEM model analysis. The subject of this paper concentrates on geometrical issues. The main difficulty of this task was the lack of full reference data regarding the bridge's original structure. The old design was incomplete and there was no actual surveying results for the undamaged structure. As a conclusion, some remarks focused on surveying measurements and on the final decision regarding this bridge are given. It was eventually exchanged into a brand new one and put into public use on the 28th of October, 2015.
14 lutego 2015 roku miał miejsce pożar na Moście Łazienkowskim – pięcioprzęsłowym obiekcie mostowym o schemacie statycznym belki ciągłej i rozpiętościach 76,5+90,0+90,0+90,0+76,5=423,0 m oraz szerokości 27,76 m, wybudowanym w latach 1972-1974, mającym bardzo duże znaczenie dla struktury komunikacyjnej Warszawy – miasta o ponad 2 mln mieszkańców (codziennie przez most przejeżdża ponad 100 tys. pojazdów). Pierwotny obiekt to konstrukcja stalowa z czterema blachownicowymi dźwigarami o wysokości 3800 mm (dźwigary zewnętrzne) i 3892 mm (wewnętrzne) w rozstawie 6114 mm+9560 mm+6114 mm i pomostem ortotropowym o żebrach wiotkich o wysokości 180 mm i rozstawie 344 mm. Elementy konstrukcji były w większości spawane lub nitowane (m.in. połączenia montażowe). Konstrukcja była wykonana ze stali St3M (pomost ortotropowy wraz z górnymi poprzecznicami) oraz 18G2A (dźwigary i dolne poprzecznice). W konstrukcji dodatkowo były zlokalizowane trzy rurociągi z wodą (dwa z zimną i jeden z ciepłą), gazociąg oraz ponad 20 kabli telekomunikacyjnych. Dostęp do nich oraz do konstrukcji od spodu, umożliwiały trzy kładki robocze o drewnianych pomostach zlokalizowane pomiędzy dźwigarami. Pożar rozpoczął się podczas wymiany tych pomostów od miejsca składowania zdemontowanych elementów drewnianych pod przęsłem 12-13. Pożar rozpoczął się wieczorem i został ugaszony nazajutrz rano. Do tego czasu objął swoim zasięgiem trzy przęsła. Na drugi dzień po tym zdarzeniu Instytut Dróg i Mostów Politechniki Warszawskiej został poproszony o wykonanie ekspertyzy uwzględniającej: badania materiałowe, weryfikację geometrii konstrukcji oraz analizę wytrzymałościową MES. Tematem niniejszej publikacji są zagadnienia związane z weryfikacją geometrii konstrukcji, która, choć najszybsza do przeprowadzenia, była utrudniona z powodu braku danych odniesienia (dokumentacja archiwalna była niekompletna i nie zawierała informacji o niwelecie obiektu sprzed pożaru).
Źródło:
Archives of Civil Engineering; 2016, 62, 4/I; 171-186
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies