Tytuł:
Prediction of the plastic component parts durability with use of a drop test simulation
Przewidywanie trwałości produktów z tworzyw sztucznych z użyciem symulacji testu zrzucania
Autorzy:
Warzecha, M.
Młyniec, A.
Uhl, T.
Powiązania:
https://bibliotekanauki.pl/articles/368999.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
test zrzucania
nieliniowy zależny od prędkości sprężysto-plastyczny model materiałowy
MES (metoda elementów skończonych)
drop test
nonlinear rate dependent elastic-plastic material model
FEA
Opis:
This paper describes the method of performance of a drop test simulation for elements made of polymeric materials. Possibilities to use material models were described and material model choices were shown. Material tests needed to obtain material model parameters were presented and the results of analysis and measurement data were shown. As an example a drop test of the housing of a car electrical box made of Polypropylene with 20% Talc filler (PPTD20), have been simulated in ABAQUS/Explicit and results have been compared with data registered by a video camera system during the real drop test of this housing.
W poniższej publikacji opisana jest metoda wykonywania symulacji testu zrzucania dla elementów wykonanych z materiałów polimerowych. Przedstawione zostały możliwe do użycia modele materiałowe wraz z modelem użytym w symulacji. Ukazane zostały także testy materiałowe konieczne do uzyskania parametrów modelu wraz z wynikami pomiarów. Jako przykład, zamodelowany został test zrzucania obudowy skrzynki bezpiecznikowej samochodu, wykonanej z Polipropylenu z 20% dodatkiem talku. Wyniki symulacji zostały porównane ze zdjęciami wykonanymi za pomocą systemu wizyjnego, podczas rzeczywistej próby zrzucania obudowy skrzynki bezpiecznikowej.
Źródło:
Mechanics and Control; 2011, 30, 1; 34-40
2083-6759
2300-7079
Pojawia się w:
Mechanics and Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilization of plastic materials for production of loaded elements of pneumatic servos
Wykorzystanie tworzyw sztucznych na obciążone elementy siłowników pneumatycznych
Autorzy:
Lisowski, E.
Kot, P.
Młyniec, A.
Powiązania:
https://bibliotekanauki.pl/articles/395607.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polimery
symulacja wtryskiwania
Moldflow
Abaqus
polymers
injection moulding simulation
ABAQUS
Opis:
The advantages of plastic materials applied for the production of vehicles and devices meant that they are used increasingly common also for production of loaded structural elements. In this work, we studied the possibility of replacing the aluminium housing of a pneumatic servo with fibre-reinforced plastic materials. The studies in question were conducted using the methods of coupled elements under the MOLDFLOW and ABAQUS system.
Zalety tworzyw polimerowych stosowanych w konstrukcji maszyn i urządzeń sprawiły, że coraz częściej wykorzystywane są one również na obciążone elementy konstrukcji. W pracy zbadano możliwość zastąpienia aluminiowego korpusu siłownika pneumatycznego tworzywem polimerowym wzmacnianym włóknami szklanymi. Badania przeprowadzono metodą elementów skończonych z wykorzystaniem systemów MOLDFLOW i ABAQUS.
Źródło:
Postępy Nauki i Techniki; 2011, 6; 179-188
2080-4075
Pojawia się w:
Postępy Nauki i Techniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of degradation on the viscosity and molecular mass of poly(lactide acid) biopolymer
Wpływ procesu degradacji na lepkość i masę cząsteczkową polilaktydu
Autorzy:
Ekiert, M.
Mlyniec, A.
Uhl, T.
Powiązania:
https://bibliotekanauki.pl/articles/327254.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
PLA
biopolymers
stability
molecular model
viscosity loss
molar mass averages
biopolimery
trwałość
model atomowy
spadek lepkości
średnie masowe
Opis:
In this paper, we present a study on stability of popular biopolymer poly(lactide acid) (PLA) under degradation process. As a main objective of this study we investigate an influence of polymer decomposition on decrease of its two physicochemical parameters – dynamic viscosity and molecular mass. To include the molar mass distribution we calculate three various mass averages: the number, the weight and the viscosity molar mass. To simulate the polylactide behavior at the atomic level we use molecular dynamics method in conjunction with reactive force field ReaxFF. To provide degradation conditions similar to human interior system we operate in the MD-NVT conditions at the temperature 310K. Based on reported in literature values of polylactide density we develop computational model of its amorphous structure. We achieve full compliance with expectations – obtained values of PLA viscosity and mass are steadily dropping. Determined trends confirm progressive polymer decomposition resulting in deterioration of polymer durability. The obtained results may be use in a future to predict a lifetime of biomedical polymer implants.
Niniejszy artykuł przedstawia badania nad stabilnością popularnego biopolimeru - polilaktydu (PLA). Celem badań była zbadanie wpływu procesu degradacji PLA na jego wybrane właściwości fizykochemiczne tj. lepkość dynamiczną i masę cząsteczkową. Aby uwzględnić zjawisko polimolekularności obliczono trzy różne średnie masowe – średnią liczbową, wagową oraz lepkościową. Symulacja zachowania polilaktydu na poziomie atomowym została wykonana z użyciem metody dynamiki molekularnej przy współpracy z reaktywnym polem siłowym ReaxFF. Narzucone, przy pomocy zespołu kanonicznego NVT, warunki degradacji były zbliżone do warunków panujących we wnętrzu ludzkiego ciała. Opierając się na wartościach gęstości polilaktydu podawanych w literaturze opracowano także atomowy model jego struktury amorficznej. Otrzymane wyniki obliczeń są całkowicie zgodne z przewidywaniami – wartości lepkości i mas spadają wraz z postępem procesu degradacji skutkując obniżoną trwałością biomateriału. Uzyskane wyniki mogą w przyszłości posłużyć do budowy modelu predykcyjnego określającego czas życia polimerowych implantów.
Źródło:
Diagnostyka; 2015, 16, 4; 63-70
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element analysis of adhesive bonds using the cohesive zone modeling method
Analiza MES połączeń klejonych z wykorzystaniem modelu kohezyjnego
Autorzy:
Korta, J.
Młyniec, A.
Zdziebko, P.
Uhl, T.
Powiązania:
https://bibliotekanauki.pl/articles/368926.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
glues
adhesives
modeling
CZM
lightweighting
kleje
adhezja
modelowanie
zmniejszanie masy
Opis:
This paper covers the subject of FE modeling of adhesive joints, which is gaining more and more attention in contemporary industry, especially in the aerospace and automotive sectors. This technique of creating structural connections possesses many advantages over mechanical or welding methods and it seems that it will be exploited extensively in the future mechanical design. The ability of joining dissimilar materials decreased minimum member cross-section size and corrosion inertness can be considered as its most important features. However, in the era of virtual prototyping, it is necessary to conduct reliable computer-assisted analyses of these types of joints. It is because most of the contemporary structures are developed as numerical models first, and only the final pro duct is prototyped physically, to validate the simulation results. The aim of this paper is to demonstrate how to elaborate reliable and accurate adhesive joint models, using a cohesive zone modeling (CZM) method in conjunction with shell-based models. The major profitable consequence of using this modeling technique is that it results in a relatively small number of spatial degrees of freedom, therefore allows for short computational times.
Niniejszy artykuł opisuje metodę modelowania numerycznego połączeń adhezyjnych, które w ostatnim czasie zysku ją dużą popularność, szczególnie w przemyśle lotniczym i samochodowym. Ta metoda spajania elementów konstrukcyjnych ma wiele zalet przewyższających tradycyjnie wykorzystywane połączenia mechaniczne oraz spawanie. Do najważniejszych zaliczyć można możliwość łączenia materiałów o odmiennym składzie chemicznym, możliwość zmniejszenia minimalnego wymiaru przekroju poprzecznego łączonych elementów oraz odizolowanie łączonych elementów, co chroni je przed korozją elektrochemiczną. Współczesne trendy projektowania zakładają pełny rozwój konstrukcji w formie modeli komputerowych, a rzeczywisty prototyp powstaje dopiero jako produkt finalny, służąc walidacji otrzymanych wyników. Dlatego też, celem badań opisanych w niniejszej pracy było przedstawienie wy korzystania modelu połączenia adhezyjnego zbudowanego na podstawie elementów typu powłokowe, oddającego w dokładny sposób zachowanie tego rodzaju spoin. W artykule opisano wykorzystanie metody modelowania kohezyjnego (CZM), której podstawową zaletą jest możliwość implementacji nawet w złożonych przypadkach, bez znacznego wydłużenia czasu ich analiz.
Źródło:
Mechanics and Control; 2014, 33, 2; 51-57
2083-6759
2300-7079
Pojawia się w:
Mechanics and Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of digital image correlation in the study of Achilles tendon strain field
Zastosowanie cyfrowej korelacji obrazów w badaniach pola odkształceń ścięgna Achillesa
Autorzy:
Holak, K.
Kohut, P.
Młyniec, A.
Ekiert, M.
Tomaszewski, K.
Uhl, T.
Powiązania:
https://bibliotekanauki.pl/articles/369079.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
vision systems
digital image correlation
biomechanical measurements
human Achilles tendon
systemy wizyjne
cyfrowa korelacja obrazów
pomiary biomechaniczne
ludzkie ścięgno Achillesa
Opis:
This paper presents an application of a vision-based measurement method in the experimental mechanics of biological materials. The displacement and strain fields of a human Achilles tendon specimen under a tensile test were computed using the digital image correlation method. Different software applications, both commercial and open source, were compared. The performance of algorithms was tested based on a referential measurement earned out by commercial software with the affine model of deformation implemented. The root mean square error of the difference between strain obtained using the reference measurement and each of the analyzed programs was computed. Additionally, an example of a full-field computation of displacement and strain field was presented.
Artykuł przedstawia zastosowanie pomiarów wizyjnych w mechanice eksperymentalnej badającej właściwości materiałów biologicznych. Pole przemieszczeń i odkształceń ludzkiego ścięgna Achillesa uzyskane podczas statycznej próby rozciągania zostało wyznaczone za pomocą algorytmu cyfrowej korelacji obrazów. Porównano kilka wybranych programów komputerowych, zarówno komercyjnych, jak i darmowych, realizujących pomiar za pomocą metody korelacji Skuteczność algorytmów była testowana na podstawie wyników referencyjnych, otrzymanych z komercyjnego programu, w którym została zaimplementowana korelacja oparta na deformowalnym modelu afinicznym. Wyznaczono błędy średniokwadratowe różnicy pomiędzy danymi referencyjnymi a danymi otrzymanymi z każdego z testowanych programów. Dodatkowo pokazano przykład uzyskanego pola przemieszczeń i odkształceń na całej powierzchni testowanej próbki.
Źródło:
Mechanics and Control; 2015, 34, 1; 19-26
2083-6759
2300-7079
Pojawia się w:
Mechanics and Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of digital image correlation to investigate the heterogeneity of Achilles tendon deformation and determine its material parameters
Autorzy:
Kohut, Piotr
Holak, Krzysztof
Ekiert, Martyna
Młyniec, Andrzej
Tomaszewski, Krzysztof A.
Uhl, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/1839687.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
digital image correlation
full-field displacement
strain measurement
vision systems
human Achilles tendon
Young’s modulus
Opis:
The challenge for researchers is to develop measurement techniques that can deal with biological specimens (e.g. the human Achilles tendon) characterized by high deformation during examination. The relevant quantity which has to be investigated in laboratory experiments is the deformation or strain field of the specimen subjected to a given load. In experimental mechanics, the most remarkable technique used for strain field computation is the Digital Image Correlation (DIC) method. In the paper, the DIC method is employed to study biomaterial parameters of human Achilles tendons (AT) subjected to tensile uniaxial loadings. The application of DIC allows the heterogeneity of tendon deformation to be taken into consideration. Young’s modulus of AT based on the strain field obtained from a vision-based measurement is estimated and the results are discussed. A map of Young’s modulus (YM) is demonstrated as well.
Źródło:
Journal of Theoretical and Applied Mechanics; 2021, 59, 1; 43-52
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies