Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Mikielewicz, J." wg kryterium: Autor


Tytuł:
Domestic combined micro heat and power plant
Domowe mikrosiłownie kogeneracyjne
Autorzy:
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1819829.pdf
Data publikacji:
2009
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
mikrosiłownie
kogeneracja
energetyka
micro heat
combined
energy sector
Opis:
Nowadays the main direction of developments in energy sector is production of electricity in big power plants. The bigger capacity of the plant the lower is cost of the unit of electricity. This direction of development reaches many barriers. So, in energy conversion field a new direction is established called dispersed cogeneration of heat and power in small power plants. In paper the micro combined heat and power unit (CHP) is presented. Produced heat by CHP can be used for preparation of hot water for domestic use, swimming pools, heating purposes or production of ice water. The source of prime energy in the micro CHP can be gas from combustion of natural resources or biomass, geothermal resource or the solar collectors. Also the waste heat from technological processes can be used for that purpose. Electricity is produced by the generator driven by the micro turbine operating on vapor of low-boiling point liquid. The power of such turbine ranges from several to tens of kilowatts. The advantage of the micro CHP is its compactness and small dimensions as well possibility for full automation of the operation of such plant. Small dimensions of the CHP are obtained through implementation of modern materials and up to date micro- or even nanotechnologies. Small dimensions of turbine and heat exchangers, simple materials and simple fabrications of parts of the plants, working in low temperatures range, lead to low costs of electricity production.
Jednym z nowych obiecujących kierunków współczesnej energetyki uzupełniającym scentralizowany sektor energetyki jest sektor energetyki rozproszonej, w którym wytwarzana jest energia elektryczna w kogeneracji z ciepłem. Istnieje szereg technologii energetyki rozproszonej o małej mocy wytwarzania energii elektrycznej i ciepła. Najkrótszy horyzont czasowy związany jest z zastosowanie parowych obiegów Rankine'a na czynnik niskowrzący (Organic Rankine Cycle-ORC) w mikrosiłowni. Na tej bazie powstała w Instytucie Maszyn Przepływowych PAN koncepcja Domowej Mikrosiłowni Kogeneracyjnej. Mikrosiłownia ta o obiegu ORC ma ona służyć do produkcji energii elektrycznej i ciepła do użytku domowego. W przyszłości Mikrosiłownia Kogeneracyjna zastąpi konwencjonalne kotły do ogrzewania obiektów takich jak: domki jednorodzinne, domy wielorodzinne, osiedla itp. Gabarytowo kocioł z Mikrosiłownią będzie niewiele różnić się od dotychczasowego kotła grzewczego ale będzie oprócz funkcji ogrzewania wytwarzać dodatkowo energię elektryczną. Mikrosiłownia parowa na czynnik niskowrzący pracująca w zakresie znacznie niższych temperatur niż silnik spalinowy i turbina gazowa wymaga mniej cennych materiałów, łatwiejsza też jest technologia jej wytworzenia. Przy jej pomocy staje się możliwe generowanie energii elektrycznej przy cenach zbliżonych do cen energii wytwarzanej w tradycyjnych siłowniach dużej mocy. Lepsze wykorzystanie energii paliwa w Mikrosiłowniach Kogeneracyjnych prowadzi do obniżenia szkodliwych emisji towarzyszących procesowi spalania paliwa. Mała siłownia kogeneracyjna może być w pełni zautomatyzowana i nie wymagać obsługi Podstawowymi elementami składowymi mikrosiłowni są: kocioł (parownik), turbina parowa, skraplacz (kondensator), generator elektryczny i pompa zasilająca. Nowa koncepcja mikrosiłowni wymaga rozwiązania szeregu nowych problemów. Jednym z nich jest wybór odpowiedniego czynnika roboczego aby zastosować kompaktne wymienniki ciepła o intensywnej wymianie ciepła w mikrokanałach, analiza obiegu uwzględnia spadki ciśnienia w wymiennikach, które z kolei wpływają na różnice temperatur w wymiennikach a tym samym i na wymiary tych wymienników ciepła. Należało więc w obliczeniach koncepcyjnych uwzględnić spadek ciśnienia przy przepływie dwufazowym przez parownik i skraplacz. Wymianę ciepła podczas wrzenia w parowniku wyznaczono z własnego modelu przepływu dwufazowego. Oprócz prac teoretycznych prowadzone są w Instytucie prace eksperymentalne. Zbudowano stanowisko eksperymentalne symulujące pracę mikrosiłowni, na którym przeprowadzono wstępne pomiary parametrów obiegu, współczynników wymiany ciepła w wymiennikach metodą Wilsona oraz sprawności ekspandera spiralnego. Otrzymane wyniki są zachęcające. W dalszych badaniach eksperymentalnych ekspander (odwrócona chłodnicza sprężarka spiralna) będzie zastąpiony mikroturbiną własnej konstrukcji.
Źródło:
Rocznik Ochrona Środowiska; 2009, Tom 11; 25-38
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilisation of bleed steam from power plant to increase saturation temperature in organic Rankine cycle
Autorzy:
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/175333.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ORC
increase of upper source temperature
bleed steam utilisation
Opis:
In the paper presented is a novel concept to utilize the heat from the turbine bleed to improve the quality of working fluid vapour in the organic Rankine cycle (ORC), which contributes to the increase of ORC efficiency and the overall efficiency of the combined system of the power plant and ORC plant. Calculations have been accomplished for the case when available is waste heat as a flow rate of hot water at a temperature of 90 ◦C, which is used for preliminary heating of working fluid in ORC cycle. That hot water is obtained as a result of conversion of exhaust gases from power plant to the energy of hot water. Then the working fluid in ORC is further heated by the bleed steam to reach 120 ◦C. Such vapour is subsequently directed to the turbine. Possible working fluids were examined, namely R134a, silicone oils MM and MDM, toluene, and ethanol. Only under conditions of 120 ◦C/40 ◦C the silicone oil MM showed the best performance, in all other cases the ethanol proved to be best performing fluid of all. Results are compared with the ‘stand alone’ ORC module showing its superiority.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2014, 126; 21-32
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowa koncepcja parownika pracującego w obiegu ORC z przepływem wspomaganym siłami kapilarnymi i grawitacyjnymi
New concept of evaporator working in the ORC circuit with flow assisted by capillary and gravitational forces
Autorzy:
Mikielewicz, J.
Mikielewicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/1819588.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
parownik
ORC
mikrosiłownia domowa
evaporator
domestic micro CHP
Opis:
Nowym obiecującym kierunkiem rozwoju współczesnej energetyki, uzupełniającym scentralizowany sektor energetyki, jest sektor energetyki rozproszonej, w którym wytwarzana jest energia elektryczna w kogeneracji z ciepłem. W Instytucie Maszyn Przepływowych PAN powstała koncepcja domowej mikrosiłowni kogeneracyjnej [1÷4]. Mikrosiłownia ta ma służyć do produkcji energii elektrycznej i ciepła do użytku domowego. W przyszłości mikrosiłownia kogeneracyjna zastąpi konwencjonalne kotły do ogrzewania obiektów. Zaletą mikrosiłowni domowej jest jej kompaktowość oraz małe wymiary. Małe wymiary siłowni uzyskuje się dzięki wykorzystaniu nowoczesnych materiałów i nowoczesnej mikro- technologii. Gabarytowo kocioł z mikrosiłownią będzie niewiele różnić się od dotychczasowego kotła grzewczego, ale będzie oprócz funkcji ogrzewania wytwarzać dodatkowo energię elektryczną. Układ taki pracuje według cyklu Clausiusa-Rankina z czynnikiem organicznym jako płynem roboczym. Źródłem energii dla mikrosiłowni, może być gaz pochodzący ze spalania zasobów naturalnych lub źródła odnawialne. Mikrosiłownia parowa na czynnik niskowrzący, pracująca w zakresie znacznie niższych temperatur niż silnik spalinowy i turbina gazowa, wymaga mniej cennych materiałów, łatwiejsza też jest technologia jej wytworzenia. Za jej pomocą staje się możliwe generowanie energii elektrycznej przy cenach zbliżonych do cen energii wytwarzanej w tradycyjnych siłowniach dużej mocy Mikrosiłownia kogeneracyjna wykorzystuje energię paliwa, w prawie 90%. To oznacza, że około 70 do 80% stanowi ciepło dostarczane do ogrzewania obiektu, a około 10 do 20% to dodatkowa produkcja energii elektrycznej. Lepsze wykorzystanie energii paliwa w mikrosiłowniach kogeneracyjnych prowadzi do obniżenia szkodliwych emisji towarzyszących procesowi spalania paliwa. Mała siłownia kogeneracyjna może być w pełni zautomatyzowana i nie wymaga obsługi. W ten sposób użytkownicy energii, posiadacze kotłów z mikrosiłownią, stają się producentami energii elektrycznej. Schemat siłowni domowej skojarzonej z kotłem przedstawia rys. 1. Podstawowymi elementami składowymi mikrosiłowni są: kocioł (parownik), maszyna ekspansyjna (turbina parowa), skraplacz, generator elektryczny i pompa obiegowa. Koncepcja mikrosiłowni domowej wymaga rozwiązania szeregu nowych problemów, takich jak dobór czynnika roboczego i innych [5]. Jednym z nich jest też opracowanie kompaktowych wymienników ciepła. To właśnie od wymiarów wymienników zależy objętość zajęta przez mikrosiłownię w kotle domowym. Wykorzystanie sił kapilarnych do przetłaczania czynnika w obiegu ORC mikrosiłowni kogeneracyjnej jest pomysłem nowym, pozwalającym na zredukowanie lub nawet wyeliminowanie pompy przetłaczającej czynnik w obiegu Rankina. Należy podkreślić w tym miejscu fakt, że w przypadku czynników niskowrzących moc wymagana do napędu pompy jest nie do pominięcia, gdyż może stanowić nawet do kilkudziesięciu procent produkowanej przez system energii elektrycznej.
The paper presents studies on the possibility of application of loop heat pipes to a modern concept of evaporator. The potential application of such evaporator is a domestic micro CHP. One of the problems in the micro CHP is excessive demand for pumping power. The design under scrutiny here helps in overcoming that issue. In the proposed evaporator there is a possibility of reducing the demand for pumping power as the evaporator will produce the extra pressure effect due to capillary forces. In such case the circulation pump operates only to compensate the pressure drop due to friction losses and the wick covers the demand for overcoming the pressure drop in the expansion device. Out of 14 tested fluids 3 were selected for further scrutiny, namely ethanol, water and ammonia. It has been assumed that the fluid should work in the evaporator at temperature of 160oC, whereas the condensation temperature is 50 oC. The results of surface tension distributions with respect to temperature have been presented in figures. Preliminary analysis of the results indicates water as having the best potential, however taking into account all issues it can be said that the best effect is obtained using ethanol.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 425-439
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamika wymienników ciepła i niestabilności w obiegu ORC
The dynamics of heat exchangers and instabilities in ORC circulation
Autorzy:
Mikielewicz, J.
Mikielewicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/1819596.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
wymiennik ciepła
ORC
niestabilność przepływu
heat exchanger
flow instability
Opis:
Z zagadnieniami odparowania czynników niskowrzących w parowniku mikrosiłowni związane są zagadnienia dynamiki i stabilności hydrodynamiczno-termicznej kanału rekuperatora-parownika, jak też i parownika pary jako całości [1÷4]. Niestabilność przepływu dwufazowego w kanale, w którym odparowuje czynnik wiąże się z wystąpieniem wahań ciśnienia i natężenia przepływu. Zbyt duże wahania ciśnienia są groźne. Mogą powodować deformację ścianek kanału, a w konsekwencji i awarię parownika. Towarzyszące pulsacjom ciśnienia, zmiany natężenia przepływu, mogą z kolei powodować kryzysy form wrzenia, co w rezultacie powoduje obniżenie efektywności wymiany ciepła w rekuperatorze. Niestabilność przepływu pary produkowanej przez parownik może prowadzić do niestabilnej pracy turbiny pracującej na ten czynnik. Stąd też zagadnienie stabilności lokalnej (przepływu w kanale, w którym odparowuje czynnik) jak i ogólnej parownika jako całości, jest ważne dla projektantów parowników mikrosiłowni. Zagadnienie stabilności przepływu dwufazowego w kanale odparowującym czynnik było analizowane w literaturze przedmiotu w aspekcie kotłów parowych. Analiza opierała się o badania charakterystyki hydraulicznej kanału. Stwierdzono, że przyczyną niestabilności przepływu w kanale jest niejednoznaczność charakterystyki spadku ciśnienia w kanale w zależności od zmian natężenia przepływu. Początkowo sądzono, że wystarczy usunąć tę niejednoznaczność, aby zapewnić stabilny przepływ, jednakże jak wykazały późniejsze badania eksperymentalne, tą drogą nie uniknie się niestabilności przepływu typu periodycznego [1÷4]. Niemniej wydaje się, że wstępne rozpatrzenie charakterystyki hydraulicznej kanału będącej źródłem niestabilności, ze względu na prostotę zagadnienia jest uzasadnionym. Takie badanie jest proste i w przypadku stwierdzenia niejednoznaczności charakterystyki hydraulicznej kanału, pozwala na uniknięcie pracochłonnego badania dynamiki układu. Proces wrzenia w przepływie jest złożony. Występuje w nim szereg skomplikowanych zjawisk. Równania dynamiki, jak też i własności czynnika są silnie nieliniowe. W pracy przedstawiono prosty hydrauliczny model pozwalający na analizę niestabilności przepływu. Model taki może służyć do zaprojektowania układu regulacji w mikrosiłowni ORC.
Instability of the twophase flow in a channel where the fluid evaporates is related to occurrence of pressure and flow rate variations. Too excessive variations of pressure may be dangerous as they can lead to deformation of channel walls and in consequence to the breakdown of the evaporator. Changes of mass flow rate, which accompany the pressure pulsations can, on the other hand, lead to boiling crisis, which would reflect in reduced rates of heat exchange in the evaporator. Instabilities of produced in evaporator can lead also to the unstable operation of turbine. Therefore the issue of local and overall stability is of significant importance to the designers of micro CHP systems. The issue of stability of two-phase flow in a channel where reagent evaporates was analyzed in the literature in terms of steam boilers. The analysis was based on studies of hydraulic characteristics of the channel. It was found that the cause of instability of flow in channel is the ambiguity of the characteristics of pressure drop in the channel, depending on changes in flow rate. Initially it was thought that removal this ambiguity would ensure that the flow is stable, however, later experimental studies showed, periodic flow instability cannot be avoided this way. The process of boiling in the flow is complex. It includes a number of complex phenomena. The equations of dynamics, as well as medium properties are highly nonlinear. The paper presents a simple hydraulic model enabling analysis of the system stability and propagation of disturbances induced by a step change of the flow rate. The proposed model can serve in design of the system of control of micro heat exchangers of the micro CHP. The works on implementation of the algorithm and control of operation of the real system are underway.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 393-407
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the efficient use of a lowtemperature heat source by the organic Rankine cycle
Autorzy:
Mikielewicz, D.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/240003.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
organic rankine cycle
heat supply
energy efficiency
organiczny obieg Rankine'a
dostawy ciepła
efektywność energetyczna
Opis:
The evaporation temperature is regarded as one of the major parameters influencing the organic Rankine cycle (ORC) efficiency. Majority of contributions in literature for ORC cycle analyses treat the heat source as if it had an infinite heat capacity. Such analyses are not valuable as the resulting temperature drops of the heat source needs to be small. That leads to the fact that the heat source is not well explored and in the case of waste heat utilization it can prove the poor economics of the ORC. In the present study cooperation of the ORC cycle with the heat source available as a single phase or phase changing fluids is considered. The analytical heat balance models have been developed, which enable in a simple way calculation of heating fluid temperature variation as well as the ratio of flow rates of heating and working fluids in ORC cycle. The developed analytical expressions enable also calculation of the outlet temperature of the heating fluid.
Źródło:
Archives of Thermodynamics; 2013, 34, 3; 61-73
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studium nad łączeniem mikro kanalikowych wymienników ciepła w wymiennik integralny
Studies on the Micro Heat Exchangers Coupling into Integral Heat Exchanger
Autorzy:
Kaczmarczyk, O.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1818558.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
mikro kanalikowy wymiennik ciepła
sieć wymienników
ORC
micro channel heat exchanger
heat exchangers grid
Opis:
As it is commonly known, heat exchangers are widely used in power generators equipment. The biggest disadvantage of conventional heat exchangers is that, in case of the energy load variation, it must be replaced by the one of different size. The aim of this work is to specify a method of combining micro channel heat exchangers into a grid, realising different powers. It was ment to specify the most accurate micro channel heat exchangers connection, in order to increase the intensity of the heat exchange process. Studied problem was about heating the ORC working medium (R134a) using waste heat (hot water). In this paper, there has been studied the fenomenon of the heat exchange process in the micro channel heat exchanger grid, which will be further called the integral heat exchanger. There have been studied three cases of micro channel heat exchangers connections, such as: parallel-parallel, parallel (heating water)-serial (R134a) and parallel (R134a) – serial (heating water). On the basis of the results of the analytical analysis it has been stated, that the serial (heating water)-parallel (R134a 7) micro channel heat exchangers combination is the most suitable for the most intensive heat exchange.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 485-506
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies on the Field Type Ground Heat Exchanger Coupled with the Compressor Heat Pump (Part 1)
Badania gruntowego wymiennika ciepła typu Field’a współpracującego ze sprężarkową pompą ciepła (część 1)
Autorzy:
Dolna, O.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1813865.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
gruntowy wymiennik ciepła typu Fielda
0D-3D
pompa ciepła sprężarkowa
field type ground heat exchanger
compressor heat pump
Opis:
Present work concerns the CFD analysis of the Field type ground heat exchanger and its influence on the compressor heat pump performance. The coaxial vertical ground heat exchanger has been chosen as in most studies the U-pipe is being considered (Yang et al., 2010). Therefore, Field type ground heat exchanger’s heat-flow characteristics are not available in the literature. Conjunction of 0D-3D level programming enabled FGHE-coupled compressor heat pump system analysis in terms of a quasi-steady continuous work lasting 170 hours. The ground coupled compressor heat pump may work in the monovalent system and complitely fulfil demand on heat, however, the heat exchange system of the low heat source needs to be designed in a proper way. Additionally, the CHP working medium needs to be chosen carefully (Bohdal et al., 2015). The CFD simulations were executed using a commercial software. Compressor heat pump cycle calculations were carried out using the author’s computational programme. The FGHE of varying geometry was investigated in terms of a long term continuous work. Varying temperature boundary conditions were taken into account. This work provides qualitative data, which may be useful at ground coupled compressor heat pump system modelling.
Niniejsza praca dotyczy analizy CFD gruntowgo wymiennika ciepła typu Field’a oraz zbadania wpływu jego pracy na działanie sprężarkowej pompy ciepła. W pracy podjęto problem gruntowego pionowego wspólosiowego wymiennika ciepła, ponieważ zdecydowana część prac naukowo-bawdawczych poświęcona jest wymiennikom gruntowym typu U-rura (Yang et al., 2010). Wobec powyższego, brak jest w literaturze cieplno-przepływowych charakterystyk gruntowego wymiennika ciepła typu Fielda. W pracy przedstawiono analizę quasi-stacjonarnej pracy gruntowej sprężarkowej pompy ciepła, co było możliwe dzięki sprzęgnięciu programowania na poziomie 0D i 3D. Praca całego systemu miała charakter ciągły i trwała 170 godzin. Sprężarkowa gruntowa pompa ciepła może pokryć zapotrzebowanie na ciepło pracując nawet w obiegu monowalentnym, ale system wymiany ciepła dolnego źródła ciepła musi być prawidłowo zaprojektowany. Ponadto, należy starannie dobrać właściwy pod względem efektywności czynnik roboczy sprężarkowej pomy ciepła (Bohdal i in., 2015). Obliczenia CFD zostały przeprowadzone przy użyciu komercyjnego oprogramowania. Natomiast, obliczenia obiegu sprężarkowej pomy ciepła zostały wykonane przy użyciu autorskiego programu. Przeanalizowano pracę GWCF o zdywersyfikowanej geometrii w trybie pracy nieprzerywanej. Zaimplementowano zmienne temperaturowe warunki brzegowe na jednej powierzchni domeny obliczeniowej. Praca zawiera jakościową analizę systemu gruntowej pompy ciepła, której wyniki mogłyby zostać wykorzystane w procesie projektowania gruntowych sprężarkowych pomp ciepła.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 240-252
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Criteria for selection of working fluid in low-temperature ORC
Autorzy:
Mikielewicz, D.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/185262.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
micro CHP
organic Rankine cycle
mikro CHP
organiczny cykl Rankine'a
Opis:
The economics of an ORC system is strictly linked to thermodynamic properties of the working fluid. A bad choice of working fluid could lead to a less efficient and expensive plant/generation unit. Some selection criteria have been put forward by various authors, incorporating thermodynamic properties, provided in literature but these do not have a general character. In the paper a simple analysis has been carried out which resulted in development of thermodynamic criteria for selection of an appropriate working fluid for subcritical and supercritical cycles. The postulated criteria are expressed in terms of non-dimensional numbers, which are characteristic for different fluids. The efficiency of the cycle is in a close relation to these numbers. The criteria are suitable for initial fluid selection. Such criteria should be used with other ones related to environmental impact, economy, system size, etc. Examples of such criteria have been also presented which may be helpful in rating of heat exchangers, which takes into account both heat transfer and flow resistance of the working fluid.
Źródło:
Chemical and Process Engineering; 2016, 37, 3; 429-440
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Turbulent heat transfer in thin liquid films at low and high heat fluxes
Turbulentna wymiana ciepła w cienkich filmach cieczowych przy małych i dużych strumieniach ciepła
Autorzy:
Mikielewicz, D.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/279216.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
blowing velocity
impinging jet
nucleate boiling
Opis:
In the paper presented are considerations of turbulent heat transfer in thin liquid films at low and high heat fluxes. Postulated have been simple models of heat transfer for laminar and turbulent liquid films formed by impinging jets and exposed to nucleate boiling, namely under high heat fluxes, as well as without nucleate boiling, at low heat fluxes, as a simplified case. Turbulence in such case is strongly modified and difficult to be modelled. Turbulence model due to Prandtl has been applied where, in the case of high heat fluxes, the mixing length is strongly modified. In the case of high heat fluxes, incorporated into the model is a blowing velocity, which models the transverse transport of momentum caused by departing bubbles. Calculated have been the velocity and temperature distributions in the liquid film, which enabled determination of the corresponding heat transfer coefficient and the Nusselt number.
W pracy przedstawiono rozwiązanie turbulentnej wymiany ciepła w cienkich filmach cieczowych przy małych i dużych strumieniach ciepła. Zaproponowano proste modele wymiany ciepła dla przypadków laminarnego i turbulentnego filmu cieczowego wytworzonego uderzającą strugą w warunkach dużych i małych strumieni cieplnych. W takich przypadkach turbulencja jest silnie modyfikowana i z tego względu trudna do modelowania. W pracy zastosowano model drogi mieszania Prandtla i w przypadku dużych strumieni cieplnych droga mieszania jest szczególnie mocno zmodyfikowana. W przypadku dużych strumieni ciepła wprowadzono do modelu tzw. prędkość wzdmuchu, która modeluje wymianę pędu w kierunku poprzecznym do przepływu wywołaną odrywającymi się od ścianki pęcherzykami. Wyznaczono rozkłady prędkości i temperatury w filmie cieczowym, które umożliwiły wyliczenie współczynnika przejmowania ciepła i liczby Nusselta.
Źródło:
Journal of Theoretical and Applied Mechanics; 2007, 45, 3; 603-619
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilisation of bleed steam heat to increase the upper heat source temperature in low-temperature ORC
Autorzy:
Mikielewicz, D.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/240701.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
utylizacja
zwiększenie górnej temperatury
bleed steam utilisation
increase of upper source temperature
ORC
Opis:
In the paper presented is a novel concept to utilize the heat from the turbine bleed to improve the quality of working fluid vapour in the bottoming organic Rankine cycle (ORC). That is a completely novel solution in the literature, which contributes to the increase of ORC efficiency and the overall efficiency of the combined system of the power plant and ORC plant. Calculations have been accomplished for the case when available is a flow rate of low enthalpy hot water at a temperature of 90 [degrees]C, which is used for preliminary heating of the working fluid. That hot water is obtained as a result of conversion of exhaust gases in the power plant to the energy of hot water. Then the working fluid is further heated by the bleed steam to reach 120 [degrees]C. Such vapour is subsequently directed to the turbine. In the paper 5 possible working fluids were examined, namely R134a, MM, MDM, toluene and ethanol. Only under conditions of 120 [degrees]C/40 [degrees]C the silicone oil MM showed the best performance, in all other cases the ethanol proved to be best performing fluid of all. Results are compared with the "stand alone" ORC module showing its superiority.
Źródło:
Archives of Thermodynamics; 2011, 32, 3; 57-70
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal-hydraulic issues of flow boiling and condensation in organic Rankine cycle heat exchangers
Autorzy:
Mikielewicz, J.
Mikielewicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/240039.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dynamika wymienników ciepła
stabilizacja przepływu
wymiennik ciepła
dynamics of heat exchangers
flow stability
heat exchangers
Opis:
In the paper presented are the issues related to the design and operation of micro heat exchangers, where phase changes can occur, applicable to the domestic micro combined heat and power (CHP) unit. Analysed is the stability of the two-phase .ow in such unit. A simple hydraulic model presented in the paper enables for the stability analysis of the system and analysis of disturbance propagation caused by a jump change of the flow rate. Equations of the system dynamics as well as properties of the working fluid are strongly non-linear. A proposed model can be applicable in designing the system of flow control in micro heat exchangers operating in the considered CHP unit.
Źródło:
Archives of Thermodynamics; 2012, 33, 1; 41-66
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal boiling temperature for ORC installation
Autorzy:
Mikielewicz, D.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/240100.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ciecz
optymalne kryteria projektowe
ORC
fluid selection
optimum design criteria
Opis:
In the paper a research on cost-effective optimum design boiling temperature for Organic Rankine Cycle utilizing low-temperature heat sources is presented. The ratio of the heat exchanger area of the boiler to the power output is used as the objective function. Analytical relations for heat transfer area as well power of the cycle are formulated. Evaporation temperature and inlet temperature of the heat source medium as well its mass flow rate are varied in the optimization method. The optimization is carried out for three working fluids, i.e. R 134a, water and ethanol. The objective function (economics profitability, thermodynamic efficiency) leads to different optimal working conditions in terms of evaporating temperature. Maximum power generation in the near-critical conditions of subcritical ORC is the highest. The choice of the working fluid can greatly affect the objective function which is a measure of power plant cost. Ethanol exhibits a minimum objective function but not necessarily the maximum cycle efficiency.
Źródło:
Archives of Thermodynamics; 2012, 33, 3; 27-37
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Axial Heat Conduction in the Wall on Convective Heat Transfer in the Microchannel
Wpływ podłużnego przewodzenia ciepła w ściance na konwekcyjną wymianę ciepła w mikrokanale
Autorzy:
Mikielewicz, J.
Rybiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/1818152.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
axial conduction in the wall
convective heat transfer
microchannel
podłużne przewodzenie w ściance
konwekcyjna wymiana ciepła
mikrokanał
Opis:
Opracowany został nowy model umożliwiający obliczenie wpływu podłużnego przewodzenia ciepła w ściance kanalika na wymianę ciepła pomiędzy ścianką a przepływającym czynnikiem w mikrokanale. Zbadany został przypadek ustalonej wymiany ciepła. Znaleziono bezwymiarowe kryterium umożliwiające ocenę ważności wzdłużnego przewodzenia ciepła w ściance. W publikacji przedstawiono porównanie wyników modelu z wynikami przy zaniedbaniu podłużnego przewodzenia ciepła oraz z wynikami innego modelu opracowanego przez Kandlikara. Dodatkowo wykonano porównanie nowego modelu z wynikami eksperymentalnymi innych autorów. Osiągnięto zadawalające rezultaty.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 82-89
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ ORC jako system poprawy efektywności energetycznej w instalacji turbiny gazowej zasilanej z układu beztlenowej stabilizacji osadów ściekowych
ORC as a Improvement System of Energy Efficiency of a Gas Turbine Installation Fed by the Anaerobic Sewage Sludge Stabilization
Autorzy:
Mikielewicz, J.
Matysko, R.
Powiązania:
https://bibliotekanauki.pl/articles/1819088.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
poprawa efektywności
instalacja turbiny
Opis:
Anaerobic fermentation obtaining methane is applied in sludge stabilization processes. Methane is used to generate heat as well as the electric current in the fuel cells systems, gas turbines or cogenerative engines characterized by the high temperature oxidation. High temperature oxidation products (H2O, CO, CO2 and other flue gas) can be used in ORC cycles to generate the electric power. The following thesis presents the project of more efficient electric power generation system than the one used in the currently and based on cogenerative aggregates (piston engines). Models mentioned in the thesis: - ORC cycle (Organic Ranking Cycle), - gas turbine - an anaerobic sludge stabilization system The presented installation is more efficient in the electricity production (about 38%) than the traditional piston cogenerative engines used for biogas combustion (about 32%).
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 2; 1367-1377
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies on the Field Type Ground Heat Exchanger Coupled with the Compressor Heat Pump (Part 2)
Badania gruntowego wymiennika ciepła typu Field’a współpracującego ze sprężarkową pompą ciepła (część 2)
Autorzy:
Dolna, O.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1813893.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
wymiennik gruntowy
0D-3D
CFD
pompa ciepła sprężarkowa
field type ground heat exchnager
compressor heat pump
Opis:
This work concerns the numerical research on the ground coupled compressor heat pump quasi-steady intermittent work. To reach the goal 0D-3D level programming coupling was applied. The work contains also the analysis of the influence of a single Field type vertical ground heat exchanger on the surrounding ground. Numerical model was validated using Bose-Parker’s algorithm and penetration theory modified by J. Mikielewicz. In order to determine the ground’s ability to thermal regeneration, CFD simulations of the Field type ground heat exchanger were carried out.
Niniejsza praca poświęcona została badaniom numerycznym quasi-stacjonarnej przerywanej pracy gruntowej sprężarkowej pompy ciepła. By osiągnąć zamierzony cel sprzęgnięto programowanie na poziomie 0D i 3D. W pracy zawarto również analizę szerokości strefy wpływu pojedynczego GWCF. Powyższe należy rozumieć jako obszar termicznego oddziaływania na grunt pionowego współosiowego gruntowego wymiennika ciepła. Walidacja modelu numerycznego została przeprowadzona w oparciu o algorytm Bosego-Parkera oraz teorię penetracji zmodyfikowaną przez J. Mikielewicza. Chcąc określić zdolność gruntu do termicznej regeneracji przeprowadzono symulacje CFD, których wyniki załączono w niniejszej pracy.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 253-269
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies