Tytuł:
Studies of scintillator response to 60 MeV protons in a proton beam imaging system
Autorzy:
Rydygier, M.
Mierzwińska, G.
Czaderna, A.
Swakoń, J.
Waligórski, M. P. R.
Powiązania:
https://bibliotekanauki.pl/articles/146249.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
beam imaging
CCD camera
scintillation detector
Opis:
A Proton Beam Imaging System (ProBImS) is under development at the Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN). The ProBImS will be used to optimize beam delivery at IFJ PAN proton therapy facilities, delivering two-dimensional distributions of beam profiles. The system consists of a scintillator, optical tract and a sensitive CCD camera which digitally records the light emitted from the proton-irradiated scintillator. The optical system, imaging data transfer and control software have already been developed. Here, we report preliminary results of an evaluation of the DuPont Hi-speed thick back screen EJ 000128 scintillator to determine its applicability in our imaging system. In order to optimize the light conversion with respect to the dose locally deposited by the proton beam in the scintillation detector, we have studied the response of the DuPont scintillator in terms of linearity of dose response, uniformity of light emission and decay rate of background light after deposition of a high dose in the scintillator. We found a linear dependence of scintillator light output vs. beam intensity by showing the intensity of the recorded images to be proportional to the dose deposited in the scintillator volume.
Źródło:
Nukleonika; 2015, 60, No. 3, part 2; 683-687
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alanine dosimetry of 60 MeV proton beam - preliminary results
Autorzy:
Michalec, B.
Mierzwińska, G.
Sowa, U.
Ptaszkiewicz, M.
Nowak, T.
Swakoń, J.
Powiązania:
https://bibliotekanauki.pl/articles/146730.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
alanine
dosimetry
electron paramagnetic resonance (EPR)
proton beam
Opis:
Electron paramagnetic resonance (EPR) spectrometry (X-band) was used to determine the dose absorbed in alanine detectors, of different shapes and different alanine content, irradiated with Co-60 gamma rays and in a 60 MeV proton beam. The goal of our study was to confirm applicability of alanine as a passive detector in therapeutic proton beam. In the paper dose response characteristic and relative efficiency of alanine are shown. The study confirmed that alanine detectors with a high alanine content (ca. 95%) may be a useful and convenient tool for dose measurements in proton beams, used for eye cancer treatment.
Źródło:
Nukleonika; 2012, 57, 4; 503-506
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dosimetric characteristics of active solid state detectors in a 60 MeV proton radiotherapy beam
Autorzy:
Sowa, U.
Nowak, T.
Michalec, B.
Mierzwińska, G.
Swakoń, J.
Olko, P.
Powiązania:
https://bibliotekanauki.pl/articles/146780.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
diamond dosimeter
diode Si
dosimetry
proton beam
Opis:
Several solid state detectors, such as dosimetric diodes, MOSFET detectors or diamond detectors are used for quality control of radiotherapy beams. The goal of this work was to determine dosimetric properties of the PTW diamond detector (DD) and the PTW silicon diode in the 60 MeV therapeutic beam (practical range in water Rp = 29.17 mm) located at the Institute of Nuclear Physics, Polish Academy of Sciences (IFJ PAN, Kraków). A PTW Markus ionization chamber was used as a reference device. The empirical correction factor for diamond detector, kDD(Rresidual), introduced in the Technical Report Series of IAEA, TRS-398 [9] as a function of beam quality, Rresidual, was found to decrease from 1.12 for Rresidual = 1.5 mm to 1.04 for Rresidual = 26 mm. The reproducibility of response of DD and PTW diodes in the proton filed did not exceed 0.11%. Our results show that diamond detectors and dosimetric diodes are useful tools for quality assurance (QA) of therapeutic proton beam, but each type of detectors has specific properties which should be taken into account when choosing particular application.
Źródło:
Nukleonika; 2012, 57, 4; 491-495
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of alanine dosimetry in dose assessment for ocular melanoma patients undergoing proton radiotherapy : preliminary results
Autorzy:
Mierzwińska, G.
Kłodowska, M.
Michalec, B.
Pędracka, A.
Rydygier, M.
Swakoń, J.
Waligórski, M. P. R.
Powiązania:
https://bibliotekanauki.pl/articles/146382.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
alanine
EPR dosimetry
proton beam
proton radiotherapy
Quality Assurance (QA)
Opis:
Basing on alanine solid state/electron paramagnetic resonance (EPR) dosimetry, a supplementary method of cumulatively recording the therapeutic dose received by ocular cancer patients undergoing fractionated proton radiotherapy is proposed. By applying alanine dosimetry during the delivery of consecutive fractions, the dose received within each fraction can be read out by EPR spectrometry and a fi nal permanent cumulative record of the total dose delivered obtained. The dose response of the alanine detector was found to be practically independent on its position within the extended proton Bragg peak region. Dose measurements based on entrance dose recorded in proton beams individually formed for each patient are presented. The described method will be applied as a complementary Quality Assurance procedure for patients undergoing proton radiotherapy at the Institute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland (IFJ PAN).
Źródło:
Nukleonika; 2015, 60, No. 3, part 2; 609-613
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies