Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Michnik, A." wg kryterium: Autor


Tytuł:
Selected hardware solutions used in the process of monitoring bioparameters
Autorzy:
Michnik, A.
Szczurek, Z.
Szuster, B.
Kubik, B.
Kowalski, P.
Powiązania:
https://bibliotekanauki.pl/articles/397967.pdf
Data publikacji:
2016
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
body area networks
telemedicine
ultra-low power
inductive charging
ECG
GSR
Bluetooth Low Energy
BioSip
sieć sensorowa na powierzchni ciała
telemedycyna
ultra low power
ładowanie indukcyjne
EKG
Opis:
The paper presents the idea behind the implementation of a system designed to monitor biomedical parameters and the subject's behaviour on the basis of the architecture of measurement modules located on the body. The system was developed as a result of market launch of new generations of electronic devices combining high functionality, small size and low power consumption. The paper presents the elements of the system called BioSip, along with hardware solutions selected for the objectives to be accomplished, i.e. providing communication between system elements that would be efficient and resistant to artefacts, extending the time of operation for battery power supply, as well as ensuring a satisfactory level of reliability and ease of use.
Źródło:
International Journal of Microelectronics and Computer Science; 2016, 7, 1; 26-32
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Endurance Training and Testosterone Treatment on the Fluorescence Spectra of Rat Serum
Autorzy:
Drzazga, Z.
Schisler, I.
Michnik, A.
Sadowska-Krępa, E.
Kłapcińska, B.
Gibińska, J.
Powiązania:
https://bibliotekanauki.pl/articles/1398660.pdf
Data publikacji:
2016-01
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
33.50.Dq
87.10.Vg
87.64.-t
87.64.kv
Opis:
The paper presents an investigation into the effects of endurance training and testosterone enanthate (TE) treatment on rat blood serum by fluorescence spectroscopy. Blood serum was collected from adolescent male Wistar rats randomized between the untrained controls and trained animals, either steroid untreated or receiving I.M. injections (8 or 80 mg/$kg_{BW}$) of testosterone enanthate. Fluorescence measurements were performed for undiluted or 20- and 500-fold diluted serum and analysed separately in the ultraviolet and visible light regions. In both regions the impact of the TE administration was more pronounced than the effect of endurance training. Moreover, in the visible region of spectrum, originated from a number of fluorescent metabolites, the influence of studied factors was more noticeable. The opposite effect of endurance training and administration of TE on serum emission was found for a lower (8 mg/$kg_{BW}$) dose of testosterone, whereas a high-dose TE (80 mg/$kg_{BW}$) treatment resulted in a return of fluorescence intensity.
Źródło:
Acta Physica Polonica A; 2016, 129, 1; 15-19
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza kinematyczna wzorców ruchowych stosowanych w rehabilitacji kończyny dolnej
Kinematic analysis of movement patterns using in lower limb rehabilitation
Autorzy:
Michnik, R.
Jurkojć, J.
Rak, Z.
Paszenda, Z.
Rycerski, W.
Bachorz, M.
Michnik, A.
Powiązania:
https://bibliotekanauki.pl/articles/98741.pdf
Data publikacji:
2011
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
metoda PNF
PNF
kończyna dolna
rehabilitacja
PNF method
Proprioceptive Neuromuscular Facilitation
lower limb
rehabilitation
Opis:
W ramach pracy przeprowadzono badania kinematyki ruchów terapeutycznych kończyny dolnej wykonywanych zgodnie z metodą PNF. W trakcie badań rejestrowano sekwencje ruchów wykonywanych przez specjalistę z dziedziny rehabilitacji metodą PNF.Analizę kinematyczną przeprowadzono z wykorzystaniem optoelektronicznego systemu do analizy ruchu APAS.
Research into kinematics of therapeutic movements of lower limb performed according to the PNF method are presented in the paper. The sequences of movements, carried out by a skilled PNF physiotherapist, were recorded and next the kinematic analyses were conducted by means of the optoelectronic motion analysis system APAS.
Źródło:
Aktualne Problemy Biomechaniki; 2011, 5; 99-104
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comprehensive method of recording psycho-physiological and environmental signals during flight
Autorzy:
Szczurek, Z.
Stankiewicz, A.
Brandt, J.
Michnik, A.
Nowak, G.
Różanowski, K.
Skibniewski, F.
Powiązania:
https://bibliotekanauki.pl/articles/333638.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
rejestrator środowiska
parametry lotu
EKG
physiological recorder
environmental recorder
flight parameters
ECG
NIBP
EMG
SPO2
GPS
GPRS
Wi-Fi
Opis:
In 2011 ITAM has completed work conducted with WIML's representatives to develop a comprehensive method of psycho-physiological pilots' signals and external environmental parameters during a test flight. It has been assumed that data will be collected "off line" during a training flight and stored in the monitoring module's memory, and after the flight it will be loaded to the operator's station system at the airport. The "On line" transmission of chosen parameters directly into a database and ongoing observation have also been anticipated. One of the main assumptions for the system was its independent work from the avionics systems of aircraft used for training. This has made it possible to use the system regardless the type of aircraft equipment and without having the necessity to stringent criteria of aviation hardware acceptance. The recording system has been designed as a distributed system consists of modules carried by the pilot, those placed permanently in the cockpit of the plane, a station for test flight preparation and reading recorded data, as well as a database system accessible via the Internet. Communication between the various system modules is to employ various transmission systems, wired as well as wireless. For safety reasons wireless communication between modules in the cockpit was not used in flight, with the exception of GSM transmission used to transfer selected data directly to the Central Acquisition System.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 21; 35-41
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transmission of biomedical data from BIOSIP modules in a wireless personal area network with synchronous measurements, and the future use in the internet of things
Autorzy:
Szuster, B.
Szczurek, Z.
Kowalski, P.
Kubik, B.
Michnik, A.
Wiśniowski, R.
Świda, K.
Powiązania:
https://bibliotekanauki.pl/articles/397939.pdf
Data publikacji:
2016
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
body sensor network
wireless medicine
low power
personal area network
Bluetooth Smart
ANT
BioSip
WPAN
Wireless Personal Area Network
Body Area Networks
internet of things (IoT)
IoT
IPv6
Internet Protocol version 6
sieć sensorowa na powierzchni ciała
medycyna bezprzewodowa
sieć osobista
Internet rzeczy
protokół internetowy w wersji 6
Opis:
The paper aims to present the organizational concept of the wireless personal area network (WPAN network) transmitting biomedical data, used in the BioSip system. The network transmits data from recording modules arranged on the subject's body to a collective node (data integrator). At the same time, all the necessary properties are maintained, i.e. low power consumption of the modules, increased resistance of the network to artefacts, the required transmission speed and signal delays. The options to synchronize measurements in various modules have also been presented, along with the resulting benefits. The wireless personal area network of BioSip modules may be based on various communication protocols, such as Bluetooth Smart or ANT. The BioSip network builds on its own protocol based on transmission mechanisms by Nordic. The software of BioSip modules may be adapted for operation in the Internet of Things through network protocol layers made available by Nordic.
Źródło:
International Journal of Microelectronics and Computer Science; 2016, 7, 1; 33-40
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechatronic rehabilitation devices to re-education of the knee joint muscles
Autorzy:
Nowak, G.
Kubik, B.
Juszyński, Ł.
Wochnik, D
Sobiech, M.
Kowalski, P.
Michnik, A.
Powiązania:
https://bibliotekanauki.pl/articles/333819.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
rehabilitation
knee joint
thermotherapy
traction
rehabilitacja
staw kolanowy
termoterapia
trakcja
Opis:
Article is devoted to innovative, mechatronic devices. These devices enable the rapid and effective knee joint rehabilitation. The following machines are computer-assisted. The devices have been designed and constructed by the Institute of Medical Technology and Equipment ITAM in Zabrze, after consultation with specialists in the field of rehabilitation of the Silesian Rehabilitation Centre ”REPTY”.
Źródło:
Journal of Medical Informatics & Technologies; 2013, 22; 271-276
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examples of the use of wireless transmission systems in the monitoring of patients during cardiac rehabilitation at home
Autorzy:
Szczurek, Z.
Gacek, A.
Brandt, J.
Curyło, A.
Kowalski, P.
Świda, K.
Geodecki, M.
Michnik, A.
Powiązania:
https://bibliotekanauki.pl/articles/333367.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
bezprzewodowa transmisja
system monitorowania
rehabilitacja kardiologiczna
wireless transmition
monitoring system
Revitus
cardiac rehabilitation
Opis:
ITAM completed work on developing a prototype of the system designed to monitor and conduct cardiac rehabilitation at home. In the course of project execution, a number of devices have been made or adapted to work within the system. The primary problem to be solved was to develop a way of communication for these devices, which would allow the transmission of necessary data in a way that would be convenient for the patient and provide the staff supervising the patient with easy access to this data. Ensuring correct operation the system required a variety of cooperating transmission systems to be used. Communication within the apartment utilizes a wireless network based on a Bluetooth link. The parent node of this network is the Base Station, which is also an intermediary for communication between devices within the apartment and the Centre for Monitoring and Communications. The main module carried by the patient is the ECG module that, in addition to its measurement function, serves as a personal area network node based on elements of the ANT standard supporting the Messenger carried by the patient. This module is also tasked with supervising the patient outside the apartment, making communication with the Centre possible via a GSM/GPRS network. The Base Station exchanges information with the Monitoring and Communication Centre located on a server via the Internet. Access for the patient's doctor or support worker to the Monitoring Centre is possible from any computer with access to the Internet by logging onto the Centre's server.
Źródło:
Journal of Medical Informatics & Technologies; 2011, 17; 159-166
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of wireless medical systems for recording biomedical parameters, created at ITAM in recent years, in light of global achievements in the field
Autorzy:
Szuster, B.
Szczurek, Z.
Kowalski, P.
Kubik, B.
Michnik, A.
Wiśniowski, R.
Świda, K.
Wołoszyn, J.
Powiązania:
https://bibliotekanauki.pl/articles/398130.pdf
Data publikacji:
2016
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
body sensor network
wireless medicine
Hexoskin
Equivital
Zephyr
Quariocor
BioSip
WBAN
wireless body area network
Monitel
sieć sensorowa na powierzchni ciała
medycyna bezprzewodowa
bezprzewodowa sieć obszaru ciała
Opis:
Progress in technology and the demand for systems used for psychophysiological measurements, which record several synchronous parameter / signal types at a time, have a significant impact on the increasing number of innovative solutions available in the market. This article focuses on the design and engineering path of the created systems with special emphasis on the latest solutions, developed at the Institute of Medical Technology and Equipment (ITAM) in Zabrze. Competitive systems and other systems are also referred to by way of a comparative analysis, both in terms of their benefits and drawbacks. The overview shows that the new system may become a competitive solution for the already existing options and that it is characterized by a number of properties that make it unique.
Źródło:
International Journal of Microelectronics and Computer Science; 2016, 7, 3; 79-86
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rehabilitation robot prototypes developed by the ITAM Zabrze
System sterowania rodziny robotów rehabilitacyjnych
Autorzy:
Michnik, A.
Brandt, J.
Szczurek, Z.
Bachorz, M.
Paszenda, Z.
Michnik, R.
Jurkojć, J.
Rycerski, W.
Janota, J.
Powiązania:
https://bibliotekanauki.pl/articles/139671.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
rehabilitation
PNF
prioprioceptiv neuromuscular facilitation
motion capture
robot
force sensors
rehabilitacja
prioprioceptywne nerwowo-mięśniowe torowanie
opanowanie ruchu
czujniki siły
Opis:
Limb physical movements disability is the result of illnesses or serious injuries, impaired execution of daily activities and limitations or even inability to perform working activity. Restoration of fitness in such cases is possible through rehabilitation that requires arduous repetition of appropriate exercises with participation of an experienced physiotherapist. Exercises using the robot to repeat movements would speed up the process of rehabilitation. The paper presents the concept of rehabilitation robot control system realizing a specified purpose.
Niepełnosprawność ruchowa kończyn powstała w wyniku przebytych chorób lub doznanych urazów, upośledza wykonywanie czynności codziennych i ogranicza a czasem uniemożliwia aktywność zawodową. Przywracanie sprawności w takich przypadkach polega między innymi na przeprowadzeniu rehabilitacji wymagającej żmudnego powtarzania odpowiednich ćwiczeń przy udziale doświadczonego fizjoterapeuty. Ćwiczenia z zastosowaniem robota do powtarzania ruchów rehabilitacyjnych pozwoliłyby ułatwić proces rehabilitacji. Praca przedstawia koncepcje systemu sterowania robota rehabilitacyjnego realizującego wymieniony cel.
Źródło:
Archive of Mechanical Engineering; 2014, LXI, 3; 433-444
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Standard Deviation of Differential Index as an innovation diagnostic tool based on kinematic parameters for objective assessment of a upper limb motion pathology
Autorzy:
Jurkojč, J.
Wodarski, P.
Michnik, R. A.
Bieniek, A.
Gzik, M.
Granek, A.
Powiązania:
https://bibliotekanauki.pl/articles/306421.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
indeksacja
patologia
SDDI
parametry kinematyczne
upper extremities
upper limb motion pathology
indexes
pathology
PULMI
Opis:
Indexing methods are very popular in terms of determining the degree of disability associated with motor dysfunctions. Currently, indexing methods dedicated to the upper limbs are not very popular, probably due to difficulties in their interpretation. This work presents the calculation algorithm of new SDDI index and the attempt is made to determine the level of physical dysfunction along with description of its kind, based on the interpretation of the calculation results of SDDI and PULMI indices. Methods: 23 healthy people (10 women and 13 men), which constituted a reference group, and a group of 3 people with mobility impairments participated in the tests. In order to examine possibilities of the utilization of the SDDI index the participants had to repetitively perform two selected rehabilitation movements of upper extremities. During the tests the kinematic value was registered using inertial motion analysis system MVN BIOMECH. Results: The results of the test were collected in waveforms of 9 anatomical angles in 4 joints of upper extremities. Then, SDDI and PULMI indices were calculated for each person with mobility impairments. Next, the analysis was performed to check which abnormalities in upper extremity motion can influence the value of both indexes and interpretation of those indexes was shown. Conclusion: Joint analysis of the both indices provides information on whether the patient has correctly performed the set sequence of movement and enables the determination of possible irregularities in the performance of movement given.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 4; 77-87
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of gender, dominant lower limb and type of target on the velocity of taekwon-do front kick
Autorzy:
Wąsik, J.
Ortenburger, D.
Góra, T.
Shan, G.
Mosler, D.
Wodarski, P.
Michnik, R. A.
Powiązania:
https://bibliotekanauki.pl/articles/306521.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
interakcja
analiza czynnikowa
szybkość
dokładność
interaction
kicking speed
kicking accuracy
factorial analysis
Opis:
Purpose: The current study aimed to quantify the main influences and the interactions (joint effects) of gender, leg and type of target on the biomechanics of front kick quality. Through the quantification, we tried to identify the relevant factors related to the kick accuracy and maximum velocity for coaching practice. Methods: A ten-camera NIR VICON MX40 motion capture system (250 Hz) was used to determine the kicking foot maximum velocity from two well-trained subject groups (8 males and 6 females). Each subject performed both left and right front kicks in a lateral standing position into the air (without a physical target), to a board, to a table tennis ball and to a training shield. The target were set on a height corresponding to a height of solar plexus of each participant. Results: The results showed that all the three factors (gender, leg and type of target) have significant influences on kicking speed ( p < 0.001) and significant interaction (joint effect) was only found between gender and target ( p < 0.001). Further analysis revealed that the males’ kicking maximum velocity was affected more by board, while females’ one was affected by the size of the target. Conclusions: The results would seem to suggest that, for males, kick-to-a-board may be the more effective method for increasing kick quality, compared to other type of target. For females, kick-to-a-small-ball appears to be effective method for increasing kick maximum velocity.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 133-138
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie sił mięśniowych podczas chodu dzieci zdrowych
Estimation of muscle forces during gait of healthy children
Autorzy:
Głowacka, A.
Świtoński, E.
Michnik, R.
Powiązania:
https://bibliotekanauki.pl/articles/99317.pdf
Data publikacji:
2012
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
siła mięśni
elektromiografia
biomechanika chodu
sEMG
muscle forces
electromyography
gait biomechanics
Źródło:
Aktualne Problemy Biomechaniki; 2012, 6; 31-36
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt urządzenia do pomiaru sił mięśniowych tułowia
Project of device for measuring the trunk muscle forces
Autorzy:
Tejszerska, D
Kościelny, A
Michnik, R
Powiązania:
https://bibliotekanauki.pl/articles/99321.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
siły mięśniowe
pomiar
MES
ANSYS
muscle forces
measurement
FEM
Opis:
W ramach pracy opracowano projekt urządzenia do oceny sił mięśni tułowia. W oparciu o przyjęte założenia opracowano cztery koncepcje urządzenia. Na podstawie przeprowadzonej optymalizacji punktowej do dalszych prac projektowych wybrano dwa warianty. Dla wybranych koncepcji urządzenia przeprowadzono obliczenia wytrzymałościowe przy wykorzystaniu MES w programie AnsysWorkbench.
In the frame of this work presents project of device for measuring the trunk muscle forces was elaborated. On the basis of the assumptions four conceptions of device were elaborated. Two variants of device were accepted on the basis of the chosen criterion. Strength analysis in ANSYS Workbench was done for chosen conceptions of device.
Źródło:
Aktualne Problemy Biomechaniki; 2010, 4; 243-248
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania antropometryczne kończyny górnej oraz pomiar siły ścisku dłoni i kciuka
Research on the anthrpometry of the human upper limb and measurement of grip and pinch strenght of a hand
Autorzy:
Łopatka, M.
Guzik-Kopyto, A.
Michnik, R.
Rycerski, W.
Powiązania:
https://bibliotekanauki.pl/articles/98870.pdf
Data publikacji:
2012
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
badanie antropometryczne
kończyna górna
dłoń
kciuk
anthrpometry research
upper limb
hand
thumb
Źródło:
Aktualne Problemy Biomechaniki; 2012, 6; 93-98
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Różnica w natężeniu dolegliwości bólowych lędźwiowego odcinka kręgosłupa pomiędzy rodzicami dzieci z niepełnosprawnością motoryczną i rodzicami dzieci pełnosprawnych
Differences in lumbar pain intensity between parents of children with motor disability and parents of children without disabilities
Autorzy:
Myśliwiec, A.
Jurkojć, J.
Michnik, R.
Nowakowska, K.
Rybok, K.
Posłuszny, A.
Powiązania:
https://bibliotekanauki.pl/articles/98860.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
kręgosłup szyjny
dolegliwości bólowe
niepełnosprawność
przeciążenie
cervical spine
pain discomfort
disability
overload
Opis:
Celem pracy była ocena stopnia niepełnosprawności wynikającej z różnicy natężenia dolegliwości bólowych w obrębie lędźwiowego odcinka kręgosłupa pomiędzy rodzicami dzieci z niepełnosprawnością motoryczną, a rodzicami dzieci pełnosprawnych.Grupa badawcza składała się z 165 osób: 69 rodziców dzieci pełnosprawnych (RDP) oraz 96 rodziców dzieci niepełnosprawnych (RDN). Badania przeprowadzono na terenie województwa śląskiego, wykorzystując kwestionariusz Oswestry (ODI –Oswestry Disability Index). Rodzice w grupie RDN wskazali na większe natężenie dolegliwości bólowych w 9 z pośród 10 obszarów skali. Dla 8 obszarów różnice pomiędzy grupami są istotne statystycznie (test U-Manna Whitneya). Uzyskane wyniki wskazują jednoznacznie, iż występowanie dolegliwości bólowych zlokalizowanych w okolicy lędźwiowego odcinka kręgosłupa jest częstsze w grupie RDN i cechuje je większe natężenie.
The aim of the work was to evaluate degree of disability of parents who care for children with or without motor disabilities. The evaluation was conducted on the basis of the intensity of lumbar pain, which affects the parents. The study group consisted of 165 participants: 69 parents of children with motor disabilities and 96 parents of children without any motor disabilities. The research was carried out in the Silesian Region.During examination a Oswestry questionnaire was used. The parents of children with motor disabilities suffered from pain of greater intensity in 9 from 10 areas of the Oswestry questionnaire. Oswestry questionnaire For 8 areas differences between examined groups were statistically significant. The results indicate that the pain in the lumbar region of spine is more intense and more common in group of parents of children with motor disabilities.
Źródło:
Aktualne Problemy Biomechaniki; 2016, 10; 37-42
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies