Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Mejri, A." wg kryterium: Autor


Wyświetlanie 1-1 z 1
Tytuł:
Dosimetric properties of gammaand electron-irradiated commercial window glasses
Autorzy:
Fuochi, P.
Corda, U.
Lavalle, M.
Kovács, A.
Baranyai, M.
Mejri, A.
Farah, K.
Powiązania:
https://bibliotekanauki.pl/articles/146494.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
silicate glass
gamma rays
electron beam
optical absorption
dosimeter
fading behaviour
Opis:
Two different types of window glasses have been investigated as possible routine dosimeters in the range of 1-50 kGy. Glass samples were irradiated with 3.4 MeV and 8.4 MeV electron beams and the results compared with those obtained by 60Co gamma irradiation. Due to the strong optical absorption at wavelengths ess than 310 nm, even at low doses, optical measurements were limited to the range 320-700 nm. In both types of glasses, irradiation induced two absorption bands around 410 and 600 nm the intensities of which are proportional to dose; the 600 nm band being less sensitive to radiation. These bands have been attributed to non bridging oxygen hole centres existing in two different configurations. Because of the rapid fading of the optical absorbance observed at room temperature immediately after irradiation (greater than 15% in two days), the samples underwent a post-irradiation thermal treatment (150 graduate C for 20 min) to improve the stability of absorbance. The fading characteristics of the irradiated and thermally treated glasses, kept in the dark at room temperature, were studied for several weeks. A fast decay, whose intensity depends on the type and energy of the ionizing radiation, was observed for few days after irradiation and thermal treatment, followed by a much slower decay. The results show that this kind of material could be used as routine dosimeters within a certain dose range, as long as proper calibrations are made for each batch of glass and the appropriate precautions are taken when doing calibration and performing routine dosimetry.
Źródło:
Nukleonika; 2009, 54, 1; 39-43
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies