Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Medina, L." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
A Characterization of Ultrasonic Full Angle Spatial Compounding as a Possible Alternative for Breast Cancer Screening
Autorzy:
Medina, L.
Camacho, J.
Fritsch, C.
Powiązania:
https://bibliotekanauki.pl/articles/177766.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
breast cancer
Full Angle Spatial Compounding
resolution
isotropy
Opis:
Breast cancer screening is based on X-ray mammography, while ultrasound is considered a complementary technique with improved detection in dense tissue. However, breast cancer screening requires a technique that provides repeatable results at the inspection interval which cannot be achieved with manual breast exploration. During the last years there have appeared several approaches to overcome this limitation by means of automated ultrasonic tomography performed with motorized probes or with a large set of array transducers. This work addresses these problems by considering a quite simple and low-cost arrangement, formed with a ring of conventional medical-grade array probes which are multiplexed to the electronics to build Full Angle Spatially Compounded (FASC) images. The work analyzes the performance of such arrangement in terms of resolution and isotropy, showing by numerical modelling and experimentally that it provides high resolution and homogeneity in the whole imaged region. The implementation of this technique would provide more than one circular FASC per second and a whole breast volume image in 1–2 minutes with conventional technology, a process fast enough to be clinically useful. Moreover, the automated technique is repeatable and can be used by the clinician to perform immediately the diagnosis without requiring additional data processing.
Źródło:
Archives of Acoustics; 2015, 40, 3; 301-310
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multimodal Ultrasonic Imaging for Breast Cancer Detection
Autorzy:
Camacho, J.
Medina, L.
Cruza, J. F.
Moreno, J. M.
Fritsch, C.
Powiązania:
https://bibliotekanauki.pl/articles/176695.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound imaging
ultrasound tomography
breast cancer
Opis:
Ultrasound is used for breast cancer detection as a technique complementary to mammography, the standard screening method. Current practice is based on reflectivity images obtained with conventional instruments by an operator who positions the ultrasonic transducer by hand over the patient’s body. It is a non-ionizing radiation, pain-free and not expensive technique that provides a higher contrast than mammography to discriminate among fluid-filled cysts and solid masses, especially for dense breast tissue. However, results are quite dependent on the operator’s skills, images are difficult to reproduce, and state-of-the-art instruments have a limited resolution and contrast to show micro-calcifications and to discriminate between lesions and the surrounding tissue. In spite of their advantages, these factors have precluded the use of ultrasound for screening. This work approaches the ultrasound-based early detection of breast cancer with a different concept. A ring array with many elements to cover 360. around a hanging breast allows obtaining repeatable and operator-independent coronal slice images. Such an arrangement is well suited for multi-modal imaging that includes reflectivity, compounded, tomography, and phase coherence images for increased specificity in breast cancer detection. Preliminary work carried out with a mechanical emulation of the ring array and a standard breast phantom shows a high resolution and contrast, with an artifact-free capability provided by phase coherence processing.
Źródło:
Archives of Acoustics; 2012, 37, 3; 253-260
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Welding Effects on the Mechanical Integrity of a Trip800 Steel: a Comparison of Laser Co2 and Gmaw Processes
Wpływ spawania na integralność mechanicznaą stali Trip800: porównanie spawania laserowego ze spawaniem elektrodą topliwą
Autorzy:
Perez-Medina, G. Y.
Lopez, H. F.
Reyes-Valdes, F. A.
Garza-Gomez, A.
Lopez-Ochoa, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/351511.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
laser
GMAW
retained austenite
color metallography
spawanie elektrodą topliwą
austenit resztkowy
metalografia barwna
Opis:
In this work a strip of a transformation induced plasticity (TRIP) steel was welded using gas metal arc welding (GMAW) and Laser CO2 welding (LBW) processes and the resultant strength and ductility of the welded joints evaluated. It was found that LBW lead to relatively high hardness in the fusion zone, FZ where the resultant microstructure was predominantly martensite. The relative volume fractions of phases developed in the welded regions were quantitatively measured using color metallography combined with X-ray diffraction analyses. It was found that the heat affected zone, HAZ developed the maximum amount of martensite (up to 32%) in the steel welded using LBW besides a mixture of bainite, retained austenite and ferrite phases. In contrast, a relatively low percent of martensite (10.8%) was found in the HAZ when the GMAW process was implemented.
Pas ze stali typu TRIP poddano spawaniu elektrodą topliwą oraz spawaniu laserowemu i oceniono wytrzymałość i plastyczność uzyskanych połączeń spawanych. Stwierdzono, że spawanie laserowe prowadzi do uzyskania stosunkowo wysokiej twardości w strefie łączenia, gdzie powstała mikrostrukturę stanowi głównie martenzyt. Względne udziały objętościowe faz w spawanych obszarach zmierzono ilościowo za pomocą barwnej metalografii w połączeniu z dyfrakcyjną analizą rentgenowską. Stwierdzono, że w przypadku stali spawanej laserowo strefa wpływu ciepła zawiera najwięcej martenzytu (do 32%), a oprócz tego mieszanine bainitu, resztkowego austenitu i ferrytu. Natomiast w strefie wpływu ciepła uzyskanej podczas spawania elektrodą topliwą stwierdzono stosunkowo niską zawartość martenzytu (10,8%).
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 4; 1427-1432
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies