Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Malmur, M." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Methods of Flushing of Sewage Sludge Collected on the Bottom of a Retention Chamber
Autorzy:
Malmur, R.
Mrowiec, M.
Powiązania:
https://bibliotekanauki.pl/articles/125069.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
drainage system
retention
sewage
sewage reservoirs
transfer reservoirs
Opis:
This paper presents new achievements in the field of designing the gravitation and gravitation-underpressure chamber for bottom flushing in the detention chamber immediately after its emptying from the accumulated sewage. Temporary accumulation of the sewage in the detention chamber of the reservoir causes partial sedimentation of the solids suspended in the liquid. The location of the flushing chamber at the maximal level of filling with sewage in the retention chamber substantially improves the effectiveness of flushing of the bottom of the retention chamber with the stream of sewage that is discharged from the flushing chamber. An opportunity for effective flushing of the sludge that remains on the bottom of a detention chamber represents an important operation which is essential for reliable functioning of retention reservoirs within sewerage systems.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 200-209
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zbiornik retencyjno-przerzutowy jako system odprowadzania wody opadowej
Ransfer reservoir as a rainwater drainage system
Autorzy:
Malmur, R.
Mrowiec, M.
Powiązania:
https://bibliotekanauki.pl/articles/399957.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
zbiorniki przerzutowe
zbiorniki kanalizacyjne
przerzut ścieków
retencja
kanalizacja deszczowa
transfer reservoirs
sewage reservoirs
sewage transfer
retention
drainage system
Opis:
Intensywne opady deszczu, a także szybkie topnienie śniegu, powodują często podtapianie terenów chronionych i przepełnianie istniejących sieci kanalizacyjnych. Sytuacje takie są uciążliwe dla mieszkańców, a także powodują znaczne straty materialne. Jednym z możliwych rozwiązań technicznych zapewniającym niezawodny odpływ ścieków do odbiornika jest przedstawiony w artykule zbiornik retencyjno-przerzutowy. Zbiornik ten ma za zadanie gromadzić odpowiednią ilość ścieków, a następnie przerzucić je do odbiorników wodnych, w przypadku, gdy nie możliwy jest ich odpływ grawitacyjny. Natomiast grawitacyjne odprowadzanie ścieków do odbiornika realizowane jest przez ich tranzytowy przepływ przez komory zbiornika.
Intensive rainfalls and snow melting often cause floods in protected areas and overflow the existing sewage systems. Such cases are particularly burdensome for the inhabitants and cause considerable physical losses. One of the possible constructional solutions to ensure the effective outflow of stormwater are transfer reservoirs located between the draining system and a receiver set discussed in this paper. If gravity outflow of sewage is impossible, the initial part of sewage volume is accumulated in the transfer reservoir and then it is transferred into the water receiver set. However, gravity discharge of sewage to the water receiver set occurs through transfer chambers in the transfer reservoir.
Źródło:
Inżynieria Ekologiczna; 2016, 48; 153-160
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of methods for dimensioning of storage reservoirs in sewage systems
Analiza porównawcza metod wymiarowania zbiorników retencyjnych w systemach kanalizacyjnych
Autorzy:
Mrowiec, M.
Malmur, R.
Powiązania:
https://bibliotekanauki.pl/articles/1818771.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
analiza porównawcza
systemy kanalizacyjne
Opis:
Praktycznym problemem przy projektowaniu zbiorników pozostaje procedura ustalania ich wymaganej objętości. W Polsce dominuje podejście skrajnie uproszczone, polegające na wykorzystywaniu uniwersalnych wzorów, których głównym przeznaczeniem było wyznaczanie chwilowych natężeń przepływu do wymiarowania przekrojów kanalizacyjnych nie zaś ustalanie kształtu hydrogramu dopływu do zbiornika. Dodatkowym problemem jest nadal brak aktualnych i wiarygodnych danych o opadach, opracowanych dla warunków krajowych. Dla potrzeb porównania dokładności metod wymiarowania, jako metodę najdokładniejsza (wartość referencyjną) przyjęto skalibrowany model hydrodynamiczny, wykonany w oparciu o rzeczywiste dane, pochodzące z sieci pluwiografów.W odniesieniu do wyników uzyskanych dla modelu numerycznego zarówno metoda oparta na wzorze IDF wg Błaszczyka jak i wg IMiGW dawały wyraźnie zaniżone wyniki wymaganej objętości retencyjnej. Kluczowe znaczenie dla wiarygodnych obliczeń zbiorników retencyjnych ma korzystanie z lokalnie zarejestrowanych danych o opadach. Zastosowanie opracowanych lokalnych krzywych IDFA (uwzględniających zasięg opadu) do wymiarowania zbiorników dało zdecydowanie lepsze wyniki niż wg uniwersalnych krzywych IDF. Przeprowadzona analiza wykazała także, że metoda diagramu opadów w swej oryginalnej postaci ma bardzo ograniczoną użyteczność w stosunku do wymiarowania zbiorników odciążających sieć kanalizacyjną. Zaproponowano metodę polegająca na opracowaniu charakterystyk opadowych dla każdego ze zdarzeń, co umożliwia uwzględnienie zmiennego w czasie natężenia opadów i ma zasadnicze znaczenie dla zwiększenia dokładności uzyskiwanych wyników. Uzyskiwany stopień niedoszacowania objętości retencyjnej na poziomie nie przekraczającym 20% pozwala na wstępne rekomendowanie tej metody dla projektowania zbiorników retencyjnych. Zastosowanie autorskiego modelu transformacji opadu w odpływ (TEO), bazującego na metodzie racjonalnej, umożliwiło uzyskanie hydrogramów dopływu do zbiornika obliczonych w oparciu o zarejestrowane na zlewni hietogramy. Porównanie wyników uzyskiwanych w oparciu o model TEO do modelu nieliniowych zbiorników, zastosowanego w programie SWMM wykazało jego dużą dokładność, przy mniejszej liczbie wymaganych parametrów wejściowych. W rozpatrywanych symulacjach obliczone objętości różniły się o mniej niż 10% od wartości referencyjnej. Możliwość uzyskania wiarygodnych wyników obliczeń bez konieczności wykonywania szczegółowego modelu hydrodynamicznego pozwala na znaczące skrócenie czasu jak i kosztów ponoszonych na etapie projektowania zbiorników retencyjnych.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 1; 272-286
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zbiornik retencyjno-przerzutowy jako nowe rozwiązanie przerzutu ścieków opadowych do odbiorników wodnych
Transfer Reservoir as a Modern Solution of Storm Water Transfer to Water Receivers
Autorzy:
Malmur, R.
Mrowiec, M.
Powiązania:
https://bibliotekanauki.pl/articles/1819265.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ścieki opadowe
zbiornik retencyjno-przerzutowy
sewage runoff
reservoir retention
Opis:
The methods used in the practice of transferring of the excessive wastewater to the water receivers consist in gravitational outflow with the collector build in the section from water outflow point to the river. The cases of frequent flooding of the stormwater system caused by the lack of sufficient gravitational transfer often forced the users to build pumping stations. The overview of the used methods of stormwater transfer from the protected drainage basin to the water receiver in the periods of high filling levels did not reveal a solution which would be universal, reliable and widely used in the practice with small adaptive modifications. Therefore, the study discussed the problems of developing of the hydraulic solution for the method of transfer of the wastewater from precipitation to the water receiver to ensure unlimited, gravitational outflow in the periods of lower levels and medium filling states in the river (and forced transfer in the period of suddenly rising levels). The idea of these solutions consists in that the facilities of transfer of the stormwater to the water receiver should be located at the protected side of the drainage basin. These solutions would ensure the possibility of emergency repairs even if high filling levels were on the river. Their shape and the way they are embedded in the natural environment cannot negatively affect the landscape planning. Implementation of the retention reservoirs in the wastewater system is an essential component of the effective process of control of the outflow of the sludge from the drainage basin. It can be (and in many cases should be) supplemented with the components of the system that guarantee a considerable improvement in reliability of operation and ensure the appropriate efficiency of the assumed system of dewatering of the drainage basin. These components also include transfer reservoir, which adopt the responsibility for transfer of the wastewater from precipitation to water receivers e.g. rivers with high filling levels and also transfer of this wastewater from depressed land with respect to the elevated levels in river. Transfer reservoirs might also be used for moving a part or the whole flow of the wastewater to the drainage basin with lower filling levels in the areas of higher location with respect to the relieved drainage. Transfer reservoirs can also operate together with sewage treatment plants. One of solutions suggested in this case is that one of the transfer reservoirs transfers the wastewater flowing to the plant to the height demanded by the technological process, whereas after treatment, the second reservoir ensures its transfer to the receiver. Based on these conditions and problems, the authors developed new solution for transfer reservoirs. The present paper presents the design and principle of operation of one of these solutions.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 3; 2339-2351
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nawroty po leczeniu chirurgicznym i skojarzonym u kobiet z rakiem szyjki macicy w stopniu IB/IIA wg FIGO
Recurrence after surgical excision and radiotherapy in cervical cancer stage IB/IIA
Autorzy:
Starzewski, J.
Sygut, J.
Malmur, M.
Klonowski, M.
Plutecki, J.
Chil, A.
Misiek, M.
Smorąg, L.
Wrona-Cyranowska, A.
Detka, K.
Krawczyk, J.
Kędzierawski, P.
Bąk-Dzierżyński, A.
Postula, T.
Powiązania:
https://bibliotekanauki.pl/articles/908418.pdf
Data publikacji:
2007
Wydawca:
Medical Communications
Tematy:
cervical cancer
clinical course
recurrence
recurrence risk evaluation based on GOG score
surgical treatment
Opis:
Aim of paper: Analysis of clinical course of tumour recurrence in patients undergoing surgical excision and radiotherapy for FIGO stage IB/IIA cervical cancer and retrospective evaluation of selected clinical-pathological tumour features in the group of patients, who developed a recurrence, with particular emphasis on recurrence-associated risk factors based on the GOG (Gynaecologic Oncology Group) scale. Material and method: Retrospective analysis encompassed 107 women treated at the OEwiêtokrzyskie Centrum Onkologii (Holycross Cancer Centre) since 2000 thru 2004. Results: Three-year symptom-free survival was obtained in 92 out of 107 women (85%). Recurrence occurred in 16 out of 107 patients (15%), thereof 9 out of 84 women (10%) originally had no lymph-node metastases and 7 out of 23 women (21%) had confirmed lymph node involvement. Recurrences were associated with lateral metastases (5 cases), distant metastases (7 cases) and lateral and distant metastases (4 cases). Recurrence-associated mortality rate was 81% (13 out of 16 patients). Currently, 3 women are alive, 2 thereof having signs of recurrence. Mean recurrence-free survival was 19.6 months and mean symptom-free survival was 8.5 months. Retrospective analysis based on the GOG scale predicted high risk of recurrence (over GOG score 120) in 14 out of 16 women (88%), who did recur and a moderate risk (GOG score 70-120) in the remaining 2 patients (12%). Conclusions: High risk of recurrence predicted by the GOG score has been confirmed in the group of women with cervical cancer FIGO stage IB/IIA undergoing combined treatment (surgery and radiotherapy) independent of invasion of regional lymph nodes. An essential risk factor for tumour recurrence is presence of tumour cells in pericervical and perivaginal tissues.
Cel pracy: Omówienie przebiegu klinicznego wznów po leczeniu chirurgicznym i uzupełniającym raka szyjki macicy w stopniu IB/IIA według FIGO oraz retrospektywna ocena wybranych cech kliniczno-patologicznych guza w grupie kobiet z nawrotem, ze szczególnym uwzględnieniem czynników ryzyka nawrotu według punktacji GOG (Gynaecologic Oncology Group Study). Materiał i metoda: Retrospektywnej analizie poddano 107 kobiet leczonych w Świętokrzyskim Centrum Onkologii (ŚCO) w latach 2000-2004. Wyniki: Trzyletnie przeżycie bez objawów nawrotu stwierdzono u 92/107 (85%) pacjentek. Wznowa pojawiła się u 16/107 (15%) chorych, w tym u 9/84 (10%) kobiet, u których nie stwierdzono przerzutów w węzłach regionalnych oraz u 7/23 (21%) kobiet z potwierdzonymi przerzutami do węzłów. Odnotowano 5 wznów bocznych, 7 odległych i 4 wznowy boczne z przerzutami odległymi. Zmarło z powodu wznowy 13/16 (81%) pacjentek. Żyją 3 kobiety, w tym dwie z objawami wznowy. Średni czas wolny od wznowy wynosił 19,6 miesiąca, a średni czas przeżycia od wykrycia wznowy - 8,5 miesiąca. U 14/16 (88%) chorych ze wznową stwierdzono retrospektywnie wysokie ryzyko wznowy (>120 punktów według GOG), a u 2/16 (12%) średnie ryzyko wznowy (70-120 punktów według GOG). Wnioski: Wysokie ryzyko wznowy według punktacji GOG potwierdziło się w grupie kobiet z nawrotem raka szyjki macicy w stopniu IB/IIA według FIGO po leczeniu chirurgicznym i skojarzonym, bez względu na zajęcie regionalnych węzłów chłonnych. Istotnym czynnikiem ryzyka wznowy jest obecność komórek nowotworowych w tkankach otaczających szyjkę macicy i pochwę.
Źródło:
Ginekologia Onkologiczna; 2007, 5, 3; 125-139
1731-5379
Pojawia się w:
Ginekologia Onkologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies