Tytuł:
Influence of aerosol concentration and multivariate processing on the indication of radon progeny concentration in air
Autorzy:
Machaj, B.
Urbański, P.
Powiązania:
https://bibliotekanauki.pl/articles/147261.pdf
Data publikacji:
2004
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon progeny
measurement
data processing
Opis:
Measurements of radon progeny concentration in air by a radon progeny monitor are sensitive to the concentration of particles suspended in air. Minimum detectable concentration and accuracy of the measurement are determined by random errors of the monitor. Multivariate data processing can be used to decrease these random errors. Influence of aerosol concentration on the measured results of radon progeny concentration in air, by an RGR-30 mining radiometer, operating on the principle of alpha radiation detection from radon progeny deposited on an air filter, were determined in a radon chamber experiment. The air suspended particle concentration and the radon concentration in the radon chamber were controlled and the corresponding radon progeny concentration was measured by the radon progeny monitor. Additionally, count rate from the monitor detector, originating from the alpha activity deposited on the air filter, was measured at intervals of one minute and was then used for the three-interval, and Principal Component Regression (PCR) data processing. It was found that for the aerosol concentration in air from 40 p/cm3 to approximately 9,000 p/cm3 indications of the radon progeny monitor depends considerably on the aerosol concentration. Radon daughter concentration normalized to the radon concentration against aerosol concentration varied from 0.3 to 0.9. In mines, where the aerosol concentration generally is high, this phenomenon has little effect on the indication of the radon progeny monitor. At low aerosols concentration, appropriate correction of radon progeny concentration has to be taken. Comparison of random errors when measured signal of the monitor (count rate against time) was processed employing the three-interval method and PCR data processing shows that PCR ensures a lower random error.
Źródło:
Nukleonika; 2004, 49, 3; 123-129
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fast measurement of radon concentration in water with Lucas cell
Autorzy:
Machaj, B.
Bartak, J.
Powiązania:
https://bibliotekanauki.pl/articles/147981.pdf
Data publikacji:
2004
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon in water
measurement
concentration
Opis:
Abstract Fast method of measurement of radon concentration in water based on flushing (bubbling) water sample with air in closed loop with Lucas cell is presented. The main feature of the method is washing radon from large sample of water to small volume of air including the volume of Lucas cell, thanks to which high radon concentration in the air and considerable sensitivity of measurement is achieved. Estimated measuring sensitivity is S = 8.5 cpm/(Bq/dm3). Random error due to statistical fluctuations of count rate at radon concentration 1, 100, 10 000 Bq/dm3 is: 11, 1.1, 0.1% correspondingly at counting (measuring) time 10 min. Minimum detectable radon concentration in water for such counting time is 0.11 Bq/dm3.
Źródło:
Nukleonika; 2004, 49, 1; 29-31
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Principal component data processing in radon metrology
Autorzy:
Machaj, B.
Urbański, P.
Powiązania:
https://bibliotekanauki.pl/articles/147140.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
principal component regression (PCR)
radon daughters measurement
radon measurement
Opis:
A gauge for the measurement of radon and radon daughters concentration was tested in a radon chamber. Count rate distribution in time at the output of radiation detectors was measured and registered. The count rate distribution in time was then processed employing Principal Component Analysis (PCA) and the Root Mean Square Error (RMSE) of the count rate was investigated. It was found that PCA processing removes great part of count rate random fluctuations originating from radiation statistics, which is resulting in a decrease of the count rate random error and in random error of concentration. The RMSE of radon daughters concentration is about 3 times lower when "raw" results are PCA processed. Such decrease of error, without PCA signal processing, would require 9 times higher air flow through the air filter on which the radon daughters are deposited. In case of the measurements of the radon concentration the drop of the error is 2-3 times higher in case of long counting time.
Źródło:
Nukleonika; 2002, 47, 1; 39-42
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Large area scintillation detector for dosimetric stand with improved light collection
Autorzy:
Machaj, B.
Mirowicz, J.
Kowalska, E.
Powiązania:
https://bibliotekanauki.pl/articles/147646.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
large area scintillator
light collection
radioactive contamination
Opis:
In order to improve scintillation light collection from a thin plastic scintillator, the shape of a light reflector, and a new concept of extraction scintillation light trapped inside the scintillator were investigated. The trapped scintillation light is extracted from the scintillator by cutting the scintillator into two pieces with the edges machined at an angle of 45 centi grade and polished. Considerable improvement of detection efficiency can be achieved when the extracted and the escape scintillation light are collected together. Prototype of such a scintillation probe was constructed and investigated.
Źródło:
Nukleonika; 2011, 56, 4; 317-321
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of radon (222Rn) and thoron (220Rn) concentration with a single scintillation cell
Autorzy:
Machaj, B.
Urbański, P.
Bartak, J.
Powiązania:
https://bibliotekanauki.pl/articles/146829.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
thoron
measurement
scintillation cell
Opis:
. A single scintillation cell (ö 54 × 74 mm) is used for the measurement of radon and thoron. The radon and thoron laden air is filtered and forced to flow at 1 dm3/min through the scintillation cell in the period of 1 10 min. The count number from alpha radiation is registered in the periods of 3 10 min and 20 30 min. Two values of detection and deposition efficiency of alpha radiation are used for radon (at air flow and air at rest in the cell) and for thoron. Measurements of radon laden air and thoron laden air showed good agreement between the reference concentration and the measured concentration, not worse than 1% for radon and not worse than 2% for thoron. Combination of radon + thoron concentration showed also a small interference ("cross talk") not worse than 1%.
Źródło:
Nukleonika; 2007, 52, 4; 167-171
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of a plastic scintillator and GM pancake tubes as alpha and beta contamination detectors in dosimetric stand
Autorzy:
Machaj, B.
Mirowicz, J.
Kowalska, E.
Powiązania:
https://bibliotekanauki.pl/articles/147069.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dosimetric stand
detection system
GM counter
plastic scintillator
Opis:
A model of detection probe with a plastic scintillator (230 × 105 × 1 mm3) with a ZnS(Ag) layer at the top, and a model with six pancake Geiger-Müller (GM) counters were investigated as alpha particles (Am-241) and beta radiation (Sr-90) contamination detection probes at a dosimetric stand. A detection probe, 166 × 104 mm2 of active area, with a proportional counter was also investigated for comparison. The scintillation probe showed a higher alpha detection efficiency and a comparable beta detection efficiency with respect to the probe containing the proportional counter. The GM probe shoved a higher alpha detection efficiency, and a lower beta detection efficiency than the proportional counter probe. Detection efficiency of the scintillation probe strongly depends on the distance from the photomultiplier tube (PMT) photocathode. Active area of the GM probe of all counters constitutes approximately 50% of its measuring area.
Źródło:
Nukleonika; 2011, 56, 1; 53-56
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A gauge for measuring the dose rate and activity of ophthalmic applicators
Autorzy:
Machaj, B.
Awistowski, E.
Do, H.
Bilski, P.
Olko, P.
Powiązania:
https://bibliotekanauki.pl/articles/147042.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dose rate
measurements
106Ru ophthalmic applicators
Opis:
A gauge was developed for determining the dose rate distribution and surface activity of ophthalmic brachytherapy applicators, particularly for 106Ru applicators. A plastic fi 2×2 mm scintillator is used as the radiation detector, featuring a high pulse count rate, which results in a low 0.5% random error, due to good counting statistics. Automatic gain control of the photomultiplier tube (PMT) is achieved using a LED as the reference light source. The PMT operates in pulse mode. Long term gain variation due to fatigue of the PMT or ambient temperature variation is thus compensated for. The count rate error due to inaccurate setting of the high voltage supply of the PMT is 0.4%, and the instability error over 7 hours of continuous operation does not exceed 1-2%, peak-to-peak.
Źródło:
Nukleonika; 2002, 47, 3; 107-111
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of dose reader CD-07 for depth-dose distribution measurements in the process of microbiological radiation decontamination
Autorzy:
Gryczka, U.
Jakowiuk, A.
Migdał, W.
Kałuska, I.
Machaj, B.
Powiązania:
https://bibliotekanauki.pl/articles/148165.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
depth-dose distribution measurements
food irradiation
microbiological decontamination
Opis:
Dose reader CD-07 has been introduced for measurements of a dose distribution during dose mapping exercises and for calculations of electron beam energy. This instrument consists of an SP-880 spectrophotometer equipped with a driving motor to move a dosimetric foil across light beam in the front of narrow light aperture. To control the movement of the foil and to present and store the measuring results a specialized software has been developed. In this paper the use of dose reader CD-07 in Performance Qualification of irradiated herbs was described.
Źródło:
Nukleonika; 2009, 54, 4; 261-265
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrological features of a beta absorption particulate air monitor operating with wireless communication system
Autorzy:
Jakowiuk, A.
Urbański, P.
Świstowski, E.
Machaj, B.
Pieńkos, J.
Kowalska, E.
Powiązania:
https://bibliotekanauki.pl/articles/146846.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ambient air
beta-ray absorption
particulate matter
wireless communication
Opis:
A system for measurements of particulate matter in the ambient air, employing beta absorption instrument AMIZ-2007 with wireless communication facilities based on GPRS technology, is presented. Uncertainty of measurements caused by the counting statistics was analyzed and it was found that at least 3 h of sampling time is needed to achieve coefficient of variation lower than 20% for the average concentration of particulate matter in the ambient air exceeding 10 μg/m3. Application of a C-14 beta ray source instead of Pm-147 improves sensitivity of the measurement ca. two times. Some results of on-line operation of the system with PM10 and PM2.5 samplers are also shown.
Źródło:
Nukleonika; 2008, 53, suppl. 2; 37-42
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies