Research on the Hourly Water Consumption Structure in Rural and Suburban Household
Autorzy:
Młyńska, Anna
Bergel, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2173357.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
hourly water consumption
rural household
suburban household
Opis:
Currently, the character of many households located in rural areas is closer to that of suburban households. The change in the characters of households located in rural areas results in changes in the size and irregularity of water demand, which should translate into a new approach at the stage of water supply systems designing. Therefore, in order to supplement the state of knowledge in this study area, this paper presents the results of the research on the structure of hourly water consumption in two households located in rural areas; the first household had a suburban character, whereas the second one was a typical rural household. The results showed differences in the amount and the distribution of hourly water consumption in the analyzed households. Except on weekends, the average hourly water consumption in rural household (RH) was higher than in suburban household (SH). In contrast, in the rural household, the distribution of hourly water consumption on all days of the week was very similar and the peak water consumption was clearly marking in the morning and in the evening. In the case of the suburban household, a tendency of increased water consumption in the evening was observed, but without clearly noticeable peak water consumption. Moreover, the structure of hourly water consumption in suburban household on Saturday and Sunday was different than on weekdays. The analyzed households were characterized by the highest share of hourly water consumption up to 20.0 dm3·h-1. In the rural household, both the amount and the distribution of hourly water consumption were determined by water use for additional purposes. In the case of the suburban household, it was shaped by the living needs of the inhabitants.
Źródło:
Journal of Ecological Engineering; 2022, 23, 9; 219--230
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of internal polyurethane coatings of cast iron pipes on the quality of transported potable water
Autorzy:
Zielina, Michał
Młyńska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2171838.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
drinking water
polyurethane coating
iron
pH value
CV
coefficient of variation
woda pitna
powłoka poliuretanowa
żeliwo
wartość pH
współczynnik zmienności
Opis:
The paper presents the results of laboratory tests to determine the effect of an internal polyurethane coating in ductile iron pipes on the quality of disinfected and non-disinfected drinking water. A decrease in the pH of water in contact with the polyurethane coating was found, which was slightly higher in the non-disinfected water than in the disinfected water. The coefficient of variation (CV) of the pH values for the chlorinated water samples was 5.02% and for the non-chlorinated water was 7.15%. The experiments also showed a rather large effect of polyurethane liner on the increase of TOC concentration in water. The presence of disinfectant further slightly increased the amount of organic compounds released. The CV values normalized to one day for TOC were as high as 193.32% and even 199.39% for disinfected water. A significant effect of polyurethane coating was observed on the color change and odor of water. On the other hand, there was no effect of polyurethane coating on alkalinity and chlorine consumption in water. The CV values normalized to one day in both cases were very small at 0.97% and 0.53%, respectively.
Źródło:
Environment Protection Engineering; 2022, 48, 3; 25--38
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza powłok poliuretanowych stosowanych do zabezpieczania wewnętrznych powierzchni przewodów wodociągowych
OF THE POLYURETHANE COATINGS USED FOR INTERNAL WATER PIPES SURFACE PROTECTION
Autorzy:
Młyńska, Anna
Zielina, Michał
Powiązania:
https://bibliotekanauki.pl/chapters/2230735.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
powłoki poliuretanowe
poliuretan
przewody wodociągowe
Opis:
Do zabezpieczania wewnętrznych powierzchni przewodów wodociągowych przed korozją coraz częściej popularne stają się powłoki poliuretanowe, co z pewnością wynika z wielu ich zalet. Pomimo tego, iż w przeciwieństwie do powłok cementowych nie zapewniają one czynnej ochrony antykorozyjnej, to jednak żywice poliuretanowe charakteryzują się natychmiastowym czasem wiązania, co powoduje, że odnawiany tą metodą rurociąg może zostać bardzo szybko przywrócony do ponownej eksploatacji. Ponadto, grubość naniesionej poliuretanowej warstwy ochronnej jest dużo mniejsza niż w przypadku wykładzin cementowych. Innymi właściwościami poliuretanów, które wpływają na wzrastającą powszechność ich stosowania jest m.in. bardzo dobra przyczepność do stali i żeliwa, a także duża wytrzymałość mechaniczna i odporność chemiczna. Biorąc pod uwagę fakt, że powłoki poliuretanowe stają się alternatywą do powszechnie stosowanych powłok cementowych, bardzo istotna jest także analiza ich wpływu na jakość wody. Wyniki przeprowadzonych dotychczas badań wskazują, że powłoki poliuretanowe powodują obniżenie wartości pH wody i przyczyniają się do pojawienia się w wodzie zanieczyszczeń organicznych w początkowym okresie kontaktu poliuretanu z wodą. Nie odnotowuje się natomiast zagrożenia przenikania substancji toksycznych z powłok poliuretanowych do wody.
To protect the internal surfaces of the water pipes against corrosion, polyurethane coatings become increasingly popular because of its many advantages. Despite of that, in contrast to the cement coatings, polyurethane coatings not provide active corrosion protection, however polyurethane resins are characterized by immediate bonding time resulting in very quickly restored time the renovated water pipeline for reuse. Moreover, the layer of polyurethane coating is much thinner than in the case of protective cement coating. Other properties of polyurethanes which affected the increasingly commonness of their use is very good adhesion to steel and iron, high mechanical strength and chemical resistance. Considering that polyurethane coatings are an alternative method to commonly used cement coatings also very important is the analysis of their impact on water quality. Results of previous researches show that polyurethane coatings cause decrease the water pH value and contribute to appearance of organic contaminations in water during the initial contact the polyurethane with water. However, danger of leaching toxic substances from polyurethane coating to water is not recorded.
Źródło:
Interdyscyplinarne zagadnienia w inżynierii i ochronie środowiska 8; 180-188
9788374939447
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Impact of the Air Temperature on Water Consumption for Household Purposes in Rural Households
Autorzy:
Bergel, Tomasz
Młyńska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1839163.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
rural household
water consumption
household purposes
indoor water use
air temperature
Opis:
The paper presents a research hypothesis assumed that the air temperature affects the amount of the water consumption per capita for household purposes (indoor water use). Investigations were conducted based on daily water meter readings of several rural households located in Mszana Górna and Włostowice (Southern Poland). Owing to the double water consumption metering, it was possible to determine the daily water consumption in households, separately for household purposes and for additional purposes. In the performed analysis, the correlation between the average daily air temperature and daily water consumption per capita was tested. For this purpose, correlation coefficients were determined and a 95% confidence interval was assumed. The obtained results showed lack of a clear dependence between the tested variables. Depending on the household, correlation coefficients indicate the existence of a correlation from slight, by weak to moderate. In addition, it was tested that the growth of the air temperature by 1°C caused an increase of the water consumption per capita in the range of 0.14 dm3•d-1•C-1•°C-1 and 1.17 dm3•d-1•C-1•°C-1 (Mszana Górna) and 0.41 dm3•d-1•C-1•°C-1 and 1.78 dm3•d-1•C-1•°C-1 (Włostowice). It can be concluded that often rapid growth of the water consumption in households in spring and summer season and the term of “water consumption per capita” used in this case, primarily concern greater water demand for additional purposes, not for residents’ household purposes.
Źródło:
Journal of Ecological Engineering; 2021, 22, 3; 289-302
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ metod renowacji przewodów wodociągowych na jakość transportowanej wody
INFLUENCE OF PIPE RENOVATION METHODS ON TRANSPORTED WATER QUALITY
Autorzy:
MŁYŃSKA, Anna
ZIELINA, Michał
Powiązania:
https://bibliotekanauki.pl/chapters/2231654.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
renowacja
przewody wodociągowe
jakość wody
Opis:
W niniejszym opracowaniu dokonano przeglądu bezwykopowych natryskowych metod renowacji przewodów wodociągowych pod kątem wpływu materiałów wykorzystywanych w tych metodach na jakość wody pitnej mającej z nimi bezpośredni kontakt. Analizie poddane zostały trzy rodzaje powłok (cementowa, z żywicy epoksydowej oraz poliuretanowej), którymi pokrywa się metodą natryskiwania odnawiane wnętrza przewodów wodociągowych. Każda z tych powłok posiada szereg zalet, jednak jak dowodzą badania w krótkim czasie po ich zastosowaniu parametry jakościowe wody mogą ulec zmianie. Przeanalizowano zmiany pH i zapachu wody oraz zmiany stopnia zużywania rozpuszczonych w wodzie dezynfektantów. W kontakcie z wyprawą cementową pH wody zwiększa się do ok. 11–12, co powoduje wzmożone przenikanie glinu z cementu do wody. Zarówno stare, jak i nowe powłoki epoksydowe nie wpływają istotnie na zmiany tego parametru, natomiast poliuretan powoduje obniżenie wartości pH wody do ok. 6. Wszystkie trzy analizowane materiały przyczyniają się do zużywania rozpuszczonych w wodzie dezynfektantów, jednak obserwuje się, że stopień zużycia chloru wolnego Cl2 jest większy niż chloraminy NH2Cl. Dodatkowo, zarówno wykorzystany do natrysku cement, jak i żywica epoksydowa oraz poliuretanowa wpływają na zapach wody i jego intensywność.
The paper presents a literature review on influence of pipe renovation trenchless methods on drinking water quality. There are analyzed three kinds of inner coating materials: cement mortar, epoxy and polyurethane, that are commonly used for ductile iron and steel pipes renovation. Each of these coatings have some advantages, however, studies show that in a short time after their application water quality parameters may be visibly changed. There were analyzed the water pH, taste and disinfectants consumption after contacting of water with sprayings. Cement mortar linings causes to water pH increase (even to 11–12) and it contributes to intensify dissolution and leaching of aluminum from the cement lining to water. Lack of any water pH change is observed after contacting of water with epoxy layer. Polyurethane causes to reduce of water pH (even to 6). All of three analyzed materials contribute to consumption of disinfectants dissolved in water. However, the degree of free chlorine consumption is generally much larger than consumption of chloramines for all of analyzed linings. All of spraying materials: cement mortar, epoxy and polyurethane resins, affect the drinking water smell.
Źródło:
Interdyscyplinarne zagadnienia w inżynierii i ochronie środowiska 6; 244-258
9788374938976
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A New Approach to the Maximum Quarterly Water Consumption Modeling on the Example of Individual Water Consumers in a Small Water Supply System
Autorzy:
Młyńska, Anna
Bergel, Tomasz
Młyński, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/2069910.pdf
Data publikacji:
2021
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
water supply system
water consumption
modeling
probability distribution
Opis:
Quarterly water consumption data collected in a small water supply system were used for elaboration of a new water consumption modeling approach. In this paper, multi-distribution statistical analysis was performed. As the Anderson-Darling test proved, at least a half out of the ten tested theoretical probability distributions can be used for description of the water consumption. The application of the PWRMSE criterion made it possible to determine, which of the tested theoretical distributions is the best-fitted to the empirical data set. In the case of total daily water consumption for the group of the households, it was Johnson distribution, whereas for the average daily water consumption per capita, it was GEV distribution. Based on the best-fitted probability distribution, a 25-year water consumption simulation with the Monte Carlo method was conducted. Because methodology of this study is based on the probability distributions, even if the type of theoretical distribution of the water consumption will change, it will be still possible to use this simulation method by assuming the other distribution.
Źródło:
Rocznik Ochrona Środowiska; 2021, 23; 180--197
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Hydraulic Load of a Local WWTP in the South-Eastern Poland Including Hydraulic Capacity of the Sewage Receiver
Autorzy:
Młyńska, Anna
Młyński, Dariusz
Chmielowski, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2202274.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
hydraulic load
sewage
sewage receiver
sewage outflow
mean low flow
SNQ
wastewater treatment plant
WWTP
Opis:
The paper constitutes the analysis of hydraulic load of a local wastewater treatment plant in the south-eastern Poland along with the analysis of sewage receiver hydraulic capacity and related receiving waters protection. Assuming that the daily outflow of treated sewage should not exceed 10% of the mean-low flow (SNQ) of the receiver, no case of daily sewage outflow greater than 10%·SNQ = 51 840 m3·d-1 was recorded. Moreover, average daily hydraulic load of the treatment plant was lower than the limit value by over 70% and the maximum recorded value – by over 40%. Furthermore, the conducted analysis shows that the particular months differed from each other in the values of the daily hydraulic load of the wastewater treatment plant at the outflow; May was the month with the highest average daily sewage outflow, while September was characterized by the lowest average daily outflow of treated sewage. There was also no clear dependence between the hydraulic load of the WWTP and the day of the week. Daily sewage outflows ranging from 10 000 m3·d-1 to 12 000 m3·d-1 constituted the largest part of all observations. The daily sewage outflows directed to the receiver prove that there is no threat to the preservation of the water environment quality.
Źródło:
Journal of Ecological Engineering; 2022, 23, 11; 261--272
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies