Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Lubowiecka, Izabela" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Modelling and Measurement of Folk Guitar : Truss Rod and Strings in Numerical Analysis of Tone
Autorzy:
Bielski, Paweł Michał
Kujawa, Marcin
Lubowiecka, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/176738.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
sound quality
musical instruments
acoustic folk guitar
string tension
truss rod
non-linear modelling
Opis:
The study makes an attempt to model a complete vibrating guitar including its non-linear features, specifically the tension-compression of truss rod and tension of strings. The purpose of such a model is to examine the influence of design parameters on tone. Most experimental studies are flawed by uncertainties introduced by materials and assembly of an instrument. Since numerical modelling of instruments allows for deterministic control over design parameters, a detailed numerical model of folk guitar was analysed and an experimental study was performed in order to simulate the excitation and measurement of gitar vibration. The virtual guitar was set up like a real guitar in a series of geometrically non-linear analyses. Balancing of strings and truss rod tension resulted in a realistic initial state of deformation, which affected the subsequent spectral analyses carried out after dynamic simulations. Design parameters of the gitar were freely manipulated without introducing unwanted uncertainties typical for experimental studies. The study highlights the importance of acoustic medium in numerical models.
Źródło:
Archives of Acoustics; 2019, 44, 1; 35-49
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Torsional buckling paradox -- extended studies
Autorzy:
Chróścielewski, Jacek.
Lubowiecka, Izabela.
Szymczak, Czesław.
Witkowski, Wojciech.
Powiązania:
Biuletyn Wojskowej Akademii Technicznej 2004, nr 6, s. 89-97
Data publikacji:
2004
Tematy:
Pręty konstrukcje badanie
Komputery stosowanie mechanika
Opis:
Analiza wyboczenia skrętnego pręta cienkościennego o dwuteowym przekroju poprzecznym ze zmienną szerokością półek.
Rys., tab.; Bibliogr.; Abstr., streszcz.
Dostawca treści:
Bibliografia CBW
Artykuł
Tytuł:
Safety and efficacy of a Ventralight ST echo ps implant for a laparoscopic ventral hernia repair – a prospective cohort study with a one-year follow-up
Autorzy:
Stetsko, Taras
Bury, Kamil
Lubowiecka, Izabela
Szymczak, Czesław
Tomaszewska, Agnieszka
Śmietański, Maciej
Szymczak, Czewsław
Śmietaski, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1394059.pdf
Data publikacji:
2016
Wydawca:
Index Copernicus International
Tematy:
ventral hernia
mesh
recurrence
pain
Ventralight ST
Opis:
Laparoscopic ventral hernia repair has become popular technique. Every year, companies are introducing new products Thus, every mesh prior to introduction in clinical settings should be tested with a dedicated tacker to discover the proper fixation algorithm. The aim of the study was to assess the safety and efficacy of the Ventralight ST implant with an ECHO positioning system and a dedicated fixation device, the SorbaFix stapler, in a prospective cohort of patients. Material and methods. The study was a prospective single centre cohort study with a one-year followup period. Fifty-two patients received operations for a ventral hernia using a laparoscopic IPOM mesh – Ventralight ST ECHO PS. The size of the mesh and the fixation method were based on mathematical considerations. A recurrence of the hernia and pain after 1, 2 and 12 months were assessed as the primary endpoints. Results. Two recurrences were noted, one in parastomal and one in a large incisional hernia. Pain was observed in 22 patients (41%) and mostly disappeared after 3 months (7%). The intensity of pain was low (VAS <2). However, 2 patients still experienced severe pain (VAS>6) until the end of the study. Conclusion. The Ventralight ST Echo PS implant fixed with a Sorbafix stapler is a valuable and safe option for a laparoscopic ventral hernia repair. In our opinion, the implant could be used in all patients due to the hernia ring diameter. According to the mathematical models and clinical practice, we do not recommend this implant in orifices with a width larger than 10 cm.
Źródło:
Polish Journal of Surgery; 2016, 88, 1; 7-14
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bezpieczeństwo i skuteczność zastosowania wewnątrzbrzusznego implantu Ventralight SY w laparoskopowym zaopatrzeniu przepuklin brzusznych – badanie prospektywne z rocznym okresem obserwacji
Autorzy:
Stetsko, Taras
Bury, Kamil
Lubowiecka, Izabela
Szymczak, Czesław
Tomaszewska, Agnieszka
Śmietański, Maciej
Szymczak, Czewsław
Śmietaski, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1394106.pdf
Data publikacji:
2016
Wydawca:
Index Copernicus International
Tematy:
przepuklina brzuszna
siatka
nawrót
ból
Ventralight ST
Opis:
Celem badania była ocena bezpieczeństwa i skuteczności zastosowania implantu Ventralight ST z systemem pozycjonującym ECHO i dedykowanym urządzeniem mocującym – staplerem SorbaFix w prospektywnym badaniu kohortowym. Marteriał i metodyka. Badanie zaplanowano jako prospektywne jednoośrodkowe badanie kohorty chorych z jednorocznym okresem obserwacyjnym. Do badania włączono 52 chorych poddanych interwencji z powodu przepukliny brzusznej za pomocą laparoskopowego zaopatrzenia z implantem Ventralight ST ECHO PS. Wielkość siatki i sposób mocowania oparto na teoretycznych założeniach matematycznych. Głównym ocenianym parametrem było wystąpienie nawrotu w 12-miesięcznej obserwacji. Wyniki. Zanotowano dwa nawroty przepukliny, jeden u chorego z przepukliną okołostomijną i drugi w dużej przepuklinie pooperacyjnej. Ból obserwowano u 22 chorych (41%) po zabiegu. U większości chorych ból ustępował po okresie 3 miesięcy (7%). Obserwowano niskie natężenie bólu (VAS <2). Jednak silny ból występował u 2 chorych (VAS >6) w całym okresie obserwacji. Wnioski. Użycie implantu Ventralight ST Echo PS mocowanego stapleremSorbafix jest wartościową i bezpieczną opcją w laparoskopowym zaopatrzeniu przepukliny brzusznej. Rozwiązanie może być użyte do zaopatrzenia chorych zakwalifikowanych do laparoskopii z uwzględnieniem wielkości przepukliny. W odniesieniu do modeli matematycznych i przedstawionych danych klinicznych autorzy nie rekomendują używania opisanego implantu do przepuklin o pierścieniu większym niż 10 cm.
Źródło:
Polish Journal of Surgery; 2016, 88, 1; 11-24
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies