Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Liu, C.-K." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Wavelength-adjustable all-optical wavelength conversion using a tunable fiber laser and an electroabsorption modulator
Autorzy:
Tseng, C.-L.
Lin, Y.-W.
Ching, P.-J.
Cheng, Y.-T.
Jou, J.-J.
Liu, C.-K.
Powiązania:
https://bibliotekanauki.pl/articles/174311.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wavelength conversion
fiber ring laser
erbium-doped fiber
electroabsorption modulator
wavelength division multiplexing (WDM) network
Opis:
A wavelength conversion scheme is presented experimentally using a wavelength tunable erbium-doped fiber laser as a probe light source and an electroabsorption modulator with a DC bias only.For the input wavelength of 1557nm with a 10-Gb/s non-return to zero signal, the Q value is 10.6and the power penalty is less than 1.5dB at a bit error rate of 10–9 at the probe wavelength of1560nm. Given a fixed Q value of 6, probe wavelengths cover a range of 25nm. Furthermore,the relationship between the range of probe wavelength and the amount of power penalty is alsoinvestigated.
Źródło:
Optica Applicata; 2016, 46, 3; 347-352
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computerized Method for Work Space Optimization in Conditions of Static Work
Autorzy:
Roman-Liu, D.
Kędzior, K.
Rzymkowski, C.
Powiązania:
https://bibliotekanauki.pl/articles/89905.pdf
Data publikacji:
1999
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
work space optimization
computer modeling
upper extremity
miejsce pracy
modelowanie komputerowe
kończyna górna
Opis:
The aim of this research was to develop a theoretical method for the ergonomic optimization of the work space of the upper limb. This method is based on a model of the upper extremity with 7 degrees of freedom. It consists of 3 rigid elements modeling the arm, forearm, and hand and 34 upper extremity muscles. The trunk is considered immobile. The shoulder joint is modeled as a rotating kinematics pair of third class, the elbow and wrist joints - of fourth class. The minimum sum of muscle force moments in the joints and soft saturation muscle cooperation criterion were used as merit criteria. The developed method makes it possible to effectively solve, in a defined work space, the task of work space optimization.
Źródło:
International Journal of Occupational Safety and Ergonomics; 1999, 5, 1; 97-108
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Object-parameter approaches to predicting unknown data in an incomplete fuzzy soft set
Autorzy:
Liu, Y.
Qin, K.
Rao, C.
Alhaji Mahamadu, M.
Powiązania:
https://bibliotekanauki.pl/articles/331019.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
fuzzy soft set
incomplete fuzzy soft set
object parameter approach
prediction
similarity measures
zbiór rozmyty
podejście obiektowe
miara podobieństwa
Opis:
The research on incomplete fuzzy soft sets is an integral part of the research on fuzzy soft sets and has been initiated recently. In this work, we first point out that an existing approach to predicting unknown data in an incomplete fuzzy soft set suffers from some limitations and then we propose an improved method. The hidden information between both objects and parameters revealed in our approach is more comprehensive. Furthermore, based on the similarity measures of fuzzy sets, a new adjustable object-parameter approach is proposed to predict unknown data in incomplete fuzzy soft sets. Data predicting converts an incomplete fuzzy soft set into a complete one, which makes the fuzzy soft set applicable not only to decision making but also to other areas. The compared results elaborated through rate exchange data sets illustrate that both our improved approach and the new adjustable object-parameter one outperform the existing method with respect to forecasting accuracy.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2017, 27, 1; 157-167
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pullout evaluation of sawbone experiment in different types of pedicle screws combined with bone cement augmentation for severe osteoporotic spine
Autorzy:
Yang, S.-C.
Liu, P.-H.
Tu, Y.-K.
Powiązania:
https://bibliotekanauki.pl/articles/307271.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
osteoporoza
kości
wytrzymałość
osteoporosis
bone cement augmentation
cannulated pedicle screw
sawbone
pullout strength
Opis:
Purpose: The conventional screw is unable to provide enough screw-bone interface strength for osteoporotic cencellous bone, and complications resulting from loosening or failure of the implants remain a significant clinical problem. Hence, the purpose of this study is to investigate pullout strength and energy in three types of the pedicle screws, including conventional solid pedicle screw, cannulated pedicle screw, and cannulated pedicle screw with a central pin, using osteoporotic sawbone test block with different bone cement volumes through pullout force testing. Methods: The control group (n = 15) of the osteoporotic sawbone test block includes groups A, B, and C to reflect three types of the pedicle screws without bone cement augmentation. The cemented group (n = 45) of the osteoporotic sawbone test block includes groups D1, D2, D3, E1, E2, E3, F1, F2, and F3 to reflect three types of the pedicle screws with PMMA bone cement of 2, 3, and 4 mL augmentation. Results: The results showed that the pullout strength and energy in the cemented group were significantly larger than that in the control group. Moreover, the best performances of the pullout strength and energy in the cemented group were evidenced obviously in the case of cannulated pedicle screw with a central pin with 4 mL bone cement augmentation. Conclusions: This study concludes that cement argumentation in the cannulated pedicle screw with a central pin can increase a pullout strength of pedicle screw for severe osteoporotic patients while bone cement of injective volume is limited.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 2; 55-64
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Bending, Impact Fracture Behavior and Characteristics of Stainless Steel Clad Plates with Different Rolling Temperature
Autorzy:
An, Q.
Fan, K. Y.
Ge, Y. F.
Liu, B. X.
He, J.
Wang, S.
Chen, C. X.
Ji, P. G.
Tolochko, O.
Powiązania:
https://bibliotekanauki.pl/articles/2049433.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stainless steel clad plate
interface characteristics
bending behavior
impact morphologies
delamination crack
Opis:
The interface characteristics, bending and impact behavior, as well as fracture characteristics of stainless steel clad plates fabricated by vacuum hot rolling at different rolling temperatures of 1100°C, 1200°C and 1300°C are investigated in detail. The interface bonding strength is gradually increased with the increasing rolling temperature due to the sufficient diffusion behavior of alloy element. The bending toughness and impact toughness are gradually decreased, while the bending strength increase with the increase of the rolling temperature, which is attributed to mechanisms of matrix softening and interface strengthening at high rolling temperature. Due to the weak interface at 1100°C, the bending and impact crack propagation path was displaced by delamination cracks, which in turn lead to reduction in stress intensity of the main crack, playing an effective role in toughening the stainless steel clad plates. Moreover, the impact fracture morphologies of clad plates show a typical ductile-brittle transition phenomenon, which is attributed to the matrix softening behavior with the increasing rolling temperature.
Źródło:
Archives of Metallurgy and Materials; 2021, 66, 1; 229-239
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies