Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Litniewski, J." wg kryterium: Autor


Tytuł:
Applying crystallography in analysis of trabecular bone backscatter
Autorzy:
Wojcik, J.
Litniewski, J.
Nowicki, A.
Gambin, B.
Powiązania:
https://bibliotekanauki.pl/articles/332506.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
Some important details of the Backscatter Effective Cross-Sections obtained for random scattering structures (like trabecular bone) are explain by comparison with the results obtained by means of the simplified theoretical model. The simplified model was (establish) and justified on the basis of the structural analysis of the results obtained for exact model of the field scattering on complex structures. The simplified model is commonly used in description of the scattering on the regular structures like crystal. Comparison with experimental results for the trabecular bone is also presented. The results allowed to conclude that crystallographic methods could be potentially useful for extracting characteristic features of trabecular bone.
Źródło:
Hydroacoustics; 2011, 14; 255-266
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Example of Structure Modeling and Analysis of Ultrasound Scattering for Trabecular Bone
Autorzy:
Wójcik, J.
Litniewski, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/177853.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multi-scattering
random complex structures
trabecular bone model
Opis:
A trabecular bone consists of trabeculae whose mechanical properties differ significantly from the surrounding marrow, therefore an ultrasonic wave propagating within the bone structure is strongly scattered. The aim of this paper was to evaluate the contribution of the first, second and higher order scattering (multiple scattering) into the total scattering of ultrasound in a trabecular bone. The scattering due to the interconnections between thick trabeculae, usually neglected in trabecular bone models, has been also studied. The basic element in our model of the trabecular bone was an elastic cylinder with a various finite-length and diameter as well as orientation. The applied model was taking into account variation of both, elements size and their spatial configuration. The field scattered on the bone model was evaluated by solving numerically the integral form of the generalized Sturm-Liouville equation describing a scalar wave in inhomogeneous and lossy media. For the scattered fields calculated numerically the effective cross-sections were determined. The influence of absorption on the scattering coefficients was demonstrated. The results allowed to conclude that within the frequency range from 0.5 to 1.5 MHz contribution of the second order scattering to the effective backscattering cross-section is at least 500 times lower than that due to the first order scattering. It was noticed that for a frequency higher than 1.5 MHz fast growth of the backscattering (reflection) coefficients, calculated for the second order scattering, occurs.
Źródło:
Archives of Acoustics; 2010, 35, 4; 701-713
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiple scattering contribution to trabecular bone backscatter
Autorzy:
Wójcik, J.
Litniewski, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/332838.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
bone backscatter
integral equations
spectral distribution
Opis:
Integral equations that describe scattering on the structure with step rise parameters, have been numerically solved on example of the trabecular bone model. The model consists of several hundred elements with randomly selected parameters. The spectral distribution of scatter coefficients in subsequent orders of scattering has been presented.
Źródło:
Hydroacoustics; 2009, 12; 227-236
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Theoretical results and numerical study on the nonlinear reflection and transmission of plane sound waves
Autorzy:
Wojcik, J.
Gambin, B.
Litniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/332766.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
theoretical and numerical model
continuity conditions
non-linear waves
lossy media
Opis:
The comparison between theoretical and numerical solutions of the reflection/transmission problem for the acoustic plane wave normally incident on the discontinuity surface between two nonlinear lossy media was presented. Numerical calculations made under the assumption that the two media have the same impedance, allow to single out the effect of nonlinearities in the description of the reflection and transmission phenomena, so they agreed with theoretical predictions. It was shown that theoretically obtained and numerically calculated results mutually confirmed themselves.
Źródło:
Hydroacoustics; 2015, 18; 181-192
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the transducer bandwidth and double pulse transmission on the encoded imaging ultrasound
Autorzy:
Trots, I.
Nowicki, A.
Lewandowski, M.
Secomski, W.
Litniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/331651.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
encoded imaging ultrasound
ultrasound imaging transducer
CGS
Opis:
An influence effect of fractional bandwidth of ultrasound imaging transducer on the gain of compressed echo signal being the complementary Golay sequences (CGS) with different spectral widths is studied in this paper. Also, a new composing transmission method of CGS is discussed together with compression technique applied in order to increase the signal-to-noise ratio (SNR) and penetration. The CGS with two different bit lengths, one-cycle and two-cycles are investigated. Two transducers with fractional bandwidth of 25% and 80% at centre frequency 6 MHz are used. The experimental results are presented, clearly proofing that increasing of the code length leads to compressed echo amplitude enhancement. The smaller the bandwidth is the larger is this effect; the pulse-echo sensitivity of the echo amplitude increases by 1.88 for 25% fractional bandwidth and 1.47 for 80% while preserving time resolution. The presented results of double transmission of short codes show the penetration and SNR improvement while maintaining dead zone.
Źródło:
Hydroacoustics; 2008, 11; 419-430
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of layer thickness by the cost function optimization: phantom study
Autorzy:
Tasinkiewicz, J.
Podhajecki, J.
Wojcik, J.
Falińska, K.
Litniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/331862.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
cortical bone thickness assessment
layered media
ultrasound attenuation
Opis:
The aim of this work is to present preliminary results of the layer thickness assessment method based on optimization approach. The developed method is based on a multilayer model structure. The measured acoustic signal reflected from the layer is compared with a simulated signal on the basis of a multilayer model. The cost function is defined as the difference between the reflected signal measured using pulse echo approach and the simulated signal. The thickness of the solid layer is the parameter which minimizes the cost function yielding desired solution. Minimization of the cost function is performed with the simulated annealing algorithm. The results obtained with the developed method using measurement data of a custom design model are compared with the reference value and the accuracy of the method is checked. The relative error of the thickness estimation is 1.44%.
Źródło:
Hydroacoustics; 2015, 18; 161-166
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Differentiation of the breast lesions using statistics of backscattered echoes
Autorzy:
Piotrzkowska-Wroblewska, H.
Dobruch-Sobczak, K.
Litniewski, J.
Chrapowicki, E.
Roszkowska-Purska, K.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/332342.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
quantitative ultrasound
breast cancer
Nakagami distribution
K distribution
Opis:
The purpose of this study was to evaluate the accuracy of statistical properties of the backscattered ultrasound in differential diagnosis of the breast lesions. The B-mode images, together with the appropriate RF echoes from the breast lesions and surrounding tissues were collected. The RF data was processed for the statistics of the backscattered echo signals, using K and Nakagami distributions characterized by the M and m parameters, respectively. Based on both, M and m parameters, a set of 18 parameters was derived. From the point of view of the sensitivity of detection of cancer, the best score was obtained using maximum value of M parameter, the best specificity was received using the differential Nakagami parameter (the differential values between lesions and surrounding tissues). In conclusion, quantitative sonography is a method which has potential to be a complementary tool for classification of the breast lesions.
Źródło:
Hydroacoustics; 2016, 19; 319-328
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistical analysis of ultrasound echo for skin lesions classification
Autorzy:
Piotrzkowska, H.
Litniewski, J.
Szymańska, A.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331930.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
Propagation of ultrasonic waves in the tissue is sensitive to the alternation of tissue composition and structure.. This paper presents the classification of healthy skin and skin lesions (basal cell carcinoma (BCC)) based on statistic parameters of the envelope of echosignal. The statistics of envelope of the ultrasonic signal was modeled using Rayleigh and non-Rayleigh (the K-distribution) statistics. Furthermore the characteristic parameter of K-distribution, the effective number of scaterrers (M) was investigated. Comparison of the results obtained for region of the skin where the BCC was diagnosed and the regions of healthy skin has shown differences in the values of M parameter. These results indicate that this parameter has the potential for extracting information useful for characterizing skin lesions.
Źródło:
Hydroacoustics; 2012, 15; 171-178
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistics of envelope of high frequency ultrasound signal backscattered in human dermis
Autorzy:
Piotrzkowska, H.
Litniewski, J.
Szymańska, E.
Lewandowski, M.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331987.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
The scattering of ultrasonic waves depends on the size, shape, acoustical properties and concentration of scatterers in tissue. In these study K distribution of the ultrasound backscatter envelope was used to assess the structural properties of the skin tissue. The custom-designed high frequency ultrasonic scanner was applied to obtain RF B-scans of the skin in vivo at the frequency of 20 ÷ 30MHz. The results are encouraging. The K distribution models the envelope statistics very well. The parameters of the K-distribution, namely, the effective number of scatterers may be useful for the skin characterization.
Źródło:
Hydroacoustics; 2010, 13; 205-214
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic Echosignal Applied to Human Skin Lesions Characterization
Autorzy:
Piotrzkowska, H.
Litniewski, J.
Szymańska, E.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/177296.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
statistics
K-distribution
Rayleigh distribution
ultrasonic scattering
human dermis
Opis:
The paper presents a classification of the healthy skin and the skin lesions (basal cell carcinoma) basing on a statistics of the envelope of ultrasonic echoes. The echoes envelopes distributions were modeled using Rayleigh and K-distribution. The distributions were compared with empirical data to find which of them better models the statistics of the echo-signal obtained from the human skin. The results indicated that the K-distribution provides a better fit. Also, a characteristic parameter of the K-distribution, the effective number of scatterers (M), was investigated. The values of the M parameter, obtained for the skin cancer (basal cell carcinoma), were lower as compared to those obtained for the healthy skin. The results indicate that the statistical quan- titative ultrasound parameters have a potential for extracting information useful for characterization of the skin condition.
Źródło:
Archives of Acoustics; 2012, 37, 1; 103-108
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Golays codes sequences in ultrasonography
Autorzy:
Nowicki, A.
Trots, I.
Secomski, W.
Litniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/332137.pdf
Data publikacji:
2004
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
The issue of maximizing penetration depth with concurrent retaining or enhancement of image resolution constitutes one of the time invariant challenges in ultrasound imaging. Concerns about potential and undesirable side effects set limits on the possibility of overcoming the frequency dependent attenuation effects by increasing peak acoustic amplitudes of the waves probing the tissue. To overcome this limitation a pulse compression technique employing 16 bits Complementary Golay Code (CGS) was implemented at 4 MHz. In comparison with other, earlier proposed, coded excitation schemes, such as chirp, pseudo-random chirp and Barker codes, the CGS allowed virtually side lobe free operation. Computer simulation results for CGS pulse compression are presented. Next three different methods and algorithms used to calculate the pairs of Golay sequences of the different length are described. Experimental results are presented in the form, which in clear way illustrates the resolution, signal penetration and contrast dynamics of ultrasonic images obtained by using Golay coded excitation.
Źródło:
Hydroacoustics; 2004, 7; 173-182
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasound imaging of stiffness with two frequency pulses
Autorzy:
Nowicki, A.
Byra, M.
Litniewski, J.
Wójcik, J.
Powiązania:
https://bibliotekanauki.pl/articles/332602.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
Nowadays there are new modalities in ultrasound imaging allowing better characterization of tissue regions with different stiffness. We are proposing a novel approach based on compression and rarefaction of tissue simultaneously with imaging. The propagating wave is a combination of two pulses. A low frequency pulse is expected to change the local scattering properties of the tissue due to compression/rarefaction while a high frequency pulse is used for imaging. Two transmissions are performed for each scanning line. First, with the imaging pulse that propagates on maximum compression caused by a low frequency wave. Next, the low frequency wave is inverted and the imaging pulse propagates over the maximum rarefaction. After the processing of the subtracted echoes from subsequent transmissions including wavelet transform and band-pass filtering, differential images were reconstructed. The low frequency wave has a visible impact on the scattering properties of the tissue which can be observed on a differential image.
Źródło:
Hydroacoustics; 2014, 17; 151-160
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametric imaging of a trabecular bone by a Scanning Acoustic Microscope
Autorzy:
Litniewski, J.
Sawicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331792.pdf
Data publikacji:
1997
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
A nondestructive method is proposed for bone quality assessment at a resolution of about 200 µm. The properties of the bone matrix itself, independent of the mass or porosity of the bone, can be determined using a Scanning Acoustic Microscope (SAM). The high resolution of the SAM makes it possible to image a single trabecula of the biopsed iliac bone sample. Two microscopic acoustic images of a trabecula are recorded. The first is created by the waves reflected from the surface of the sample. The other is formed by the reflections from the bottom. These images are processed further and two parametric images are calculated. They reflect the distribution of impedance and attenuation in the bone. The method is applied to examine trabeculae in bone samples biopsed from patients with metabolic bone diseases.
Źródło:
Hydroacoustics; 1997, 1; 199-204
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametric sonographic imaging - application of synthetic aperture technique to imaging attenuation of ultrasound in tissue structures
Autorzy:
Litniewski, J.
Klimonda, Z.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331882.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
Ultrasonic imaging is a well-established technique in medicine. However, in most conventional applications of clinical ultrasonic scanners only the peak amplitude echogenicity is used to create the image. Moreover, signal envelope detection destroys potentially useful information about frequency dependence of acoustic properties of tissue comprised in RF backscattered echoes. We have explored the possibility of developing the method of imaging the distribution of the acoustic attenuation in tissue. We expect that the method will help in localization of the pathological states of tissue including tumors and diffuse liver diseases. The spatial resolution and precision of the method are crucial for medical diagnosis, hence the synthetic aperture technique was applied for ultrasonic data collection. The final goal of the presented project is to develop reliable diagnostic tool, which could be implemented in standard USG systems, as the new visualization mode.
Źródło:
Hydroacoustics; 2012, 15; 99-110
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statistical properties of pulse-echo signal backscattered in trabecular bone
Autorzy:
Litniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/331602.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
trabecular bone
pulse-echo signal
ultrasonic signal
Opis:
The paper considers the application of statistical properties of backscattered ultrasonic signal for assessment of the trabecular bone status. Computer simulations were conducted to investigate the properties of the ultrasound pulse-echo signal, as it is received on the transducer surface after scattering in trabecular bone. Results indicated that while for the well-defined trabeculae properties within the simulated bone structure the signal envelope values are Rayleigh distributed the significant departures from Rayleigh statistics may be expected as the thickness of trabeculae become random. The influence of the altering of mechanical properties of the bone tissue building the trabeculae on the signal statistical parameters was unnoticeable. The initial experiments confirming some cases of departure from Rayleigh statistics for envelopes of backscattered signals are also discussed.
Źródło:
Hydroacoustics; 2008, 11; 253-264
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies