Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kwarciak-Kozłowska, A." wg kryterium: Autor


Tytuł:
Application of Polysulfone Membranes for Coke-Making Wastewater Treatment
Membrany polisulfonowe w oczyszczaniu ścieków koksowniczych
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/388945.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
oczyszczanie ścieków koksowniczych
układy zintegrowane
ciśnieniowe techniki membranowe
cokemaking wastewater treatment
integrated system
membranes pressure techniques
Opis:
Considering the complicated and variable type of coke-making sewages their purification strategy is difficult to generalize and it requires an integrated system, which joins biological and physicochemical separated processes. In the paper the researches were presented, which purpose was to define the efficiency of purifying matting pressure membrane techniques – ultrafiltration and reverse osmosis. In the process of low-pressure filtration flat membranes, applied in the laboratory, were different in terms of compactness of structure and porosity.
Ze względu na złożony i zmienny skład ścieków koksowniczych strategia ich oczyszczania jest trudna do uogólnienia i wymaga prowadzenia tego procesu w układach zintegrowanych, kojarzących biologiczne i fizykochemiczne procesy jednostkowe. W artykule omówiono badania, których celem było określenie efektywności oczyszczania ścieków koksowniczych w układzie kojarzącym ciśnieniowe techniki membranowe, a mianowicie ultrafiltrację i odwróconą osmozę. W procesie niskociśnieniowej filtracji zastosowano wytwarzane w laboratorium płaskie membrany polisulfonowe różniące się zwartością struktury i porowatością.
Źródło:
Ecological Chemistry and Engineering. A; 2011, 18, 12; 1751-1762
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coking plant wastewater treatment in integrated systems combining volume coagulation and advanced oxidation with pressure membrane techniques
Oczyszczanie poprocesowych wód koksowniczych w układach zintegrowanych łaczących metody koagulacji objetościowej i pogłębionego utleniania z ciśnieniowymi technikami membranowymi
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/395880.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
ścieki koksownicze
koagulacja objętościowa
odczynnik Fentona
ciśnieniowe techniki membranowe
ultrafiltracja
coke plant wastewater
volumetric coagulation
Fenton's reagent
pressure membrane techniques
ultrafiltration
Opis:
The article compares the efficiencies of coke plant wastewater treatment in the integrated systems that combine physicochemical and chemical purification methods with ultrafiltration and reverse osmosis. The wastewater treated came from the "Coke Plant Czestochowa New". In the process of volume coagulation the coagulant used was sulfate (VI) iron (III)-PIX-113, with the dosage of 400 mg/dm3 and pH was 9. In the advanced oxidation Fenton's reagent was applied, with the concentration of iron equal to 0.8g/dm3 and hydrogen peroxide 2.4 g/dm3. Coke plant wastewater treatment after its initial purification was performed by means of ultrafiltration process with the use of a polysulfone membrane with 16% weight content of polysulfones in the film-forming solution and a 5-second time of solvent evaporation from the membrane surface. In spite of the fact that treated coke oven wastewater presented high values of pollution indicators, making it impossible to drain into the natural receiver or sewer, it was posttreated in the process of reverse osmosis using a nylon membrane (ADF), of an American company Osmonics. The article also presents an attempt of modelling of low-pressure membrane filtration efficiency based on the relaxation model assumptions.
W artykule porównano efektywności oczyszczania ścieków koksowniczych pochodzących z zakładu koksowniczego "Koksownia Częstochowa Nowa" w układach zintegrowanych, które łączyły ze sobą fizykochemiczną oraz chemiczną metodę oczyszczania z ultrafiltracją i odwróconą osmozą. Proces koagulacji objętościowej prowadzono siarczanem (VI) żelaza (III)-PIX-113, którego dawka wynosiła 400 mg/dm3 a pH środowiska wynosiło 9 natomiast pogłębionego utleniania z wykorzystaniem odczynnika Fentona, stosując stężenie żelaza równe 0,8 g/dm3 i nadtlenku wodoru 2,4 g/dm3. Oczyszczanie poprocesowych wód koksowniczych po ich wstępnym oczyszczeniu prowadzono stosując proces ultrafiltracji z wykorzystaniem płaskiej polisulfonowej membrany o 16% wag. zawartości polisulfony w roztworze błonotwórczym i 5-cio sekundowym czasem odparowaniem rozpuszczalnika z powierzchni membrany. Ponieważ tak oczyszczone ścieki koksownicze nadal charakteryzowały się wysokimi wartościami wskaźników zanieczyszczeń, co uniemożliwiło odprowadzenie ich do odbiornika naturalnego lub kanalizacji doczyszczono, je w procesie odwróconej osmozy z zastosowaniem poliamidowej membrany (ADF) amerykańskiej firmy Osmonics. W pracy zaprezentowano również próbę modelowania wydajności procesu niskociśnieniowej filtracji membranowej w oparciu o założenia modelu relaksacyjnego.
Źródło:
Civil and Environmental Engineering Reports; 2011, 7; 83-98
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Membrany polisulfonowe w oczyszczaniu ścieków koksowniczych
Application of polysulfone membranes for coke-making wastewater treatment
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/126367.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
oczyszczanie ścieków koksowniczych
układy zintegrowane
ciśnieniowe techniki membranowe
polisulfonowe membrany ultrafiltracyjne
cokemaking wastewater treatment
membrane pressure techniques
integrated system
polysulfone membranes
Opis:
Z uwagi na złożony i zmienny skład ścieków koksowniczych strategia ich oczyszczania jest trudna do uogólnienia i wymaga prowadzenia tego procesu w układach zintegrowanych, kojarzących biologiczne i fizykochemiczne procesy jednostkowe. W artykule omówiono badania, których celem było określenie efektywności oczyszczania ścieków koksowniczych w układzie łączącym ciśnieniowe techniki membranowe, ultrafiltrację i odwróconą osmozę. W procesie niskociśnieniowej filtracji zastosowano wytwarzane w laboratorium płaskie membrany polisulfonowe różniące się zwartością struktury i porowatością.
The applied more and more often in wastewater treatment technology integrated membranes system are the most often preliminary system purification and final purification. The applied in investigations process of ultarfiltration had for removal from purified coke making wastewater high-molecular organic compounds during when process of reverse osmosis had to provided removing the rest of low-molecular organic compounds and mineral substances. It was showed that direct carrying away cleaned sewages into the natural environment was impossible from the attention to higher, compared with standardized, concentration of ammonia on the level 22.4 mg + NH+4 /dm 3. The applied purification wastewater should be cleaned by ammonia stripping. From prepared ultrafiltration polysulfone membranes the most profitable showed membrane with the polymer content of 16% in solution.
Źródło:
Proceedings of ECOpole; 2009, 3, 1; 185-190
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of Ultrafiltration Process Efficiency in Coke Plant Wastewater Treatment with the Use of Industrial Membranes
Modelowanie wydajności procesu ultrafiltracyjnego oczyszczania ścieków koksowniczych z zastosowaniem membran komercyjnych
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Korus, I.
Powiązania:
https://bibliotekanauki.pl/articles/387903.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ultrafiltracja
ścieki koksownicze
ciśnieniowe techniki membranowe
membrany komercyjne
ultrafiltration
coke plant wastewater
high pressure membrane techniques
commercial membranes
Opis:
In the research conducted there was determined the coke plant waste treatment efficiency in the integrated process that combines ultrafiltration with the reverse osmosis system. In both pressure filtration methods commercial Osmonics membranes were applied. The degree of removal efficiency was evaluated according to changes in the values of selected pollution indicators that characterized “raw” and cleaned wastewater. On the basis of the relaxation method assumptions there was made an attempt to predict the efficiency of the membranes used at the initial stage of ultrafiltration process carried out in non-stationary arrangement. The values of the initial permeate flux and saturation flux, experimentally determined, as well as time constants, determined graphically, allowed to calculate theoretical temporary permeate flux for selected low pressure membranes.
W przeprowadzonych badaniach określono efektywność oczyszczania ścieków koksowniczych w układzie zintegrowanym łączącym ultrafiltrację z procesem odwróconej osmozy. W obu procesach filtracji ciśnieniowej stosowano membrany komercyjne amerykańskiej firmy Osmonics. Stopień oczyszczenia ścieków oceniano na podstawie zmiany wartości wskaźników zanieczyszczeń, takich jak: stężenie węgla ogólnego oraz organicznego, cyjanków, fenoli, ChZT oraz azotu amonowego charakteryzujących ścieki surowe i oczyszczone. Korzystając z modelu relaksacyjnego, podjęto próbę prognozowania wydajności membran stosowanych w procesie ultrafiltracji ścieków, prowadzonym w układzie niestacjonarnym. Doświadczalnie wyznaczone wartości strumieni początkowych permeatów, strumieni nasycenia oraz wyznaczone w sposób graficzny stałe czasowe umożliwiły obliczenie teoretycznych chwilowych strumieni permeatów dla wybranych membran niskociśnieniowych.
Źródło:
Ecological Chemistry and Engineering. A; 2012, 19, 4-5; 457-470
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling performance in reverse osmosis wastewater treatment post-trial coke in the integrated systems based on the assumptions of the relaxation model
Modelowanie wydajności procesu odwróconej osmozy w oczyszczaniu poprocesowych wód koksowniczych w układzie zintegrowanym w oparciu o założenia modelu relaksacyjnego
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/395870.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków koksowniczych
koagulacja objętościowa
model relaksacyjny
odwrócona osmoza
coking wastewater
volume coagulation
advanced oxidation
relaxation model
reverse osmosis
Opis:
The paper presents the results of studies on coking wastewater, coming from the coke plant "Koksownia Czestochowa Nowa" in two integrated systems associating coagulation volume and advanced oxidation with reverse osmosis. The process of coagulation were performed using iron sulfate (III), (PIX 113) of 400 mg/dm3 and wastewater acidity at pH = 9. The second processes - advanced oxidation was carried out using Fenton's reagent. The concentration of iron (II) was 0.8 g/dm3 and hydrogen peroxide 2.4 g/dm3. Coke post-process water after its initial treatment was subjected to high-pressure membrane filtration. In the process of reverse osmosis a flat polyamide membrane ADF of Osmonics was used. Transmembrane pressure was 2 MPa and the linear speed of water on the membrane surface of 2m/s. Comparison of the effectiveness of wastewater treatment in both tested systems has shown that the system combining the advanced oxidation with reverse osmosis is more effective. In addition, this study attempts to model effectiness of the process of reverse osmosis in both studied systems, based on the assumptions of a relaxation model. An experimentally determined dependence of changes in volume of treated wastewater fluxes from the time of the high-pressure membrane filtration, and the values of time constant efficiency of the process characterized by a decrease to below economic viability allowed us fo verify this model.
W pracy zaprezentowano wyniki badań oczyszczania ścieków koksowniczych, pochodzących z zakładu koksowniczego "Koksownia Częstochowa Nowa", w dwóch układach zintegrowanych kojarzących koagulację objętościową oraz pogłębione utlenianie z procesem odwróconej osmozy. Proces koagulacji realizowano z zastosowaniem siarczanu żelaza (III), (PIX 113) o dawce 400 mg/dm3 i pH ścieków na poziomie pH=9. Drugi z procesów - pogłębione utlenianie przeprowadzono stosując odczynnik Fentona. Stężenie jonów żelaza (II) wynosiło 0,8 g/dm3 natomiast nadtlenku wodoru 2,4 g/dm3. Poprocesowe wody koksownicze po ich wstępnym oczyszczeniu poddawano wysokociśnieniowej filtracji membranowej. W procesie odwróconej osmozy stosowano poliamidową membranę płaską ADF amerykańskiej firmy Osmonics. Ciśnienie transmembranowe wynosiło 2 MPa natomiast liniowa prędkość ścieków nad powierzchnią membrany 2m/s. Porównanie efektywności oczyszczania przedmiotowych ścieków w obu układach badawczych wykazało, że skuteczniejszym okazał się system łączący pogłębione utlenianie z odwrócona osmozą. Ponadto w niniejszej pracy podjęto próbę modelowania wydajności procesu odwróconej osmozy w obu przebadanych układach w oparciu o założenia modelu relaksacyjnego. Wyznaczone na drodze doświadczalnej zależności zmiany wielkości strumieni oczyszczanych ścieków od czasu prowadzenia wysokociśnieniowej filtracji membranowej oraz wartości stałych czasowych charakteryzujących spadek wydajności procesu poniżej opłacalności ekonomicznej pozwoliły na weryfikację tego modelu.
Źródło:
Civil and Environmental Engineering Reports; 2011, 6; 19-32
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie wydajności procesu ultrafiltracyjnego oczyszczania ścieków koksowniczych z zastosowaniem membran komercyjnych
Modeling of ultrafiltration process efficiency in treatment coke plant wastewater with use industrial membranes
Autorzy:
Mielczarek, K.
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Korus, I.
Powiązania:
https://bibliotekanauki.pl/articles/127380.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ultrafiltracja
ścieki koksownicze
ciśnieniowe techniki membranowe
modelowanie wydajności procesu ultrafiltracji
ultrafiltration
coke plant wastewater
high pressure membrane techniques
commercial membranes
Opis:
Przedstawiono efektywność procesu oczyszczania poprocesowych wód koksowniczych w układzie zintegrowanym ultrafiltracja-odwrócona osmoza. W procesach ciśnieniowej filtracji membranowej zastosowano polimerowe membrany amerykańskiej firmy Osmonics. Wyznaczenie na drodze doświadczalnej ultrafiltracyjnych strumieni permeatów początkowego (J0) i równowagowego (nasycenia - J∞) oraz w sposób graficzny stałej czasowej t0 umożliwiło, zgodnie z założonym modelem relaksacyjnym, przeprowadzenie obliczeń pozwalających na prognozowanie wydajności stosowanych membran.
In the article there have been presented the results of research whose aim was to determine the effectiveness of treating the coke plant wastewater in the integrated ultrafiltration - reverse osmosis system. In the process pressure membrane filtration was carried out on using the polymer membranes of an American Osmonics brand. Determining ultrafiltration initial permeat fluxes (J0) and equilibrium (saturations - J∞) on the experimental road and into the graphic way of the temporary constant (t0) enabled based on the relaxation model established, that describes, define the possibility of predicting the polysulfone ultrafiltration membranes efficiency in the process of coke industry wastewater treatment.
Źródło:
Proceedings of ECOpole; 2009, 3, 2; 483-489
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie ścieków koksowniczych w układzie zintegrowanym łączącym proces koagulacji z ciśnieniowymi technikami membranowymi
Coking wastewater treatment in the integrated system coagulation - pressure membrane techniques
Autorzy:
Mielczarek, K.
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1819445.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ścieki koksownicze
techniki membranowe
coking wastewater
membrane technology
Opis:
Z uwagi na ograniczone zasoby gazu i ropy naftowej podstawowym surowcem energetycznym w Polsce jest nadal węgiel kamienny, wykorzystywany m.in. do produkcji paliw koksowniczych w procesie pirolizy [1]. Jak wiadomo zakłady koksownicze niekorzystnie oddziaływają na środowisko naturalne między innymi z uwagi na generowanie podprocesowych wód koksowniczych obciążonych trudno biodegradowalnymi (BZT5/ChZT<0,02) substancjami toksycznymi [2]. W ich skład wchodzą między innymi: wielopierścieniowe węglowodory aromatyczne, związki heterocykliczne, oleje, substancje smołowe oraz związki nieorganiczne tj.: cyjanki, siarczki, siarczany, tiosiarczany, amoniak, a także jony metali ciężkich [3]. Z tego też względu ścieki koksownicze przed odprowadzeniem do odbiornika powinny być poddane procesowi oczyszczania. W zależności od rodzaju zanieczyszczeń metody ich oczyszczania powinny być tak dobrane, aby przy jak najniższych nakładach finansowych zapewnić najwyższy stopień usunięcia zanieczyszczeń. Zwiększenie efektywności oczyszczania ścieków wiąże się z rozbudową systemów ich oczyszczania o nowe procesy jednostkowe lub sprowadza się do modyfikacji układów już pracujących. Z uwagi na coraz bardziej złożony skład przemysłowych strumieni odpadowych do ich oczyszczania stosuje się układy zintegrowane kojarzące odpowiednie procesy jednostkowe. Wśród metod fizyczno-chemicznych stosowanych w przypadku ścieków obciążonych zanieczyszczeniami występującymi w postaci koloidów i drobnej zawiesiny bardzo często wykorzystywany jest proces koagulacji. Obiecującym rozwiązaniem w oczyszczaniu ścieków koksowniczych wydaje się być zastosowanie układu zintegrowanego łączącego koagulację z ultrafiltracją i odwróconą osmozą [4÷6]. W pracy omówiono wpływ procesu koagulacji na poprawę efektywności oczyszczania poprocesowych wód koksowniczych w układzie łączącym ciśnieniowe techniki membranowe tj. ultrafiltrację z odwróconą osmozą.Podjęto również próbę określenia możliwości prognozowania wielkości ultrafiltracyjnych strumieni permeatów zarówno w procesie oczyszczania ścieków koksowniczych w układzie łączącym ciśnieniowe procesy membranowe jak i w przypadku kiedy wody poprocesowe były wstępnie podczyszczane metodą koagulacji.
The paper presents results of studies aimed at determining the effectiveness of coking wastewater treatment in two integrated systems. In one system wastewater is treated using combined processes of ultrafiltration and reverse osmosis. In the second system, to increase the efficiency of wastewater treatment, an additional step of treatment is introduced - initial volume coagulation. Low-pressure membrane filtration process was carried out on membrane made of polysulfone 16% by weight. The participation of film-forming polymer in solution and during the evaporation of the solvent from the membrane surface equal to 5 s. The introduction of coking wastewater pretreatment by coagulation method resulted in the removal of such contaminants which are present mainly in the form of colloidal and macromolecular substances and thus provided a more efficient membrane ultrafiltration in the next stage of purification. Treatment of wastewater after the filtration process was performed by low-pressure reversed osmosis on membrane of polyamidetype ADF's Osmonics. Basing on assumptions of relaxation model, describing the changes in permeate flux during membrane filtration system carried out in non-stationary system, attempt to determine the possibilities of predicting the size of ultrafiltration permeate fluxes was made.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1965-1984
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie efektywności oczyszczania poprocesowych wód koksowniczych z zastosowaniem procesów koagulacji oraz pogłębionego utleniania
Comparing the effectiveness of treatment coking industry wastewater with applying for the coagulation process and advanced oxidation processes
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/400981.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki koksownicze
koagulacja objętościowa
koagulanty PIX
pogłębione utlenianie
odczynnik Fentona
odwrócona osmoza
coke wastewater
volumetric coagulation
coagulants-PIX
advanced oxidation processes
reagent Fenton
reverse osmosis
Opis:
W artykule omówiono badania, których celem było porównanie efektywności oczyszczania ścieków z przemysłu koksowniczego w procesach koagulacji objętościowej i pogłębionego utleniania z zastosowaniem odczynnika Fentona. W przypadku z pierwszej z metod przebadano 4 rodzaje koagulantów żelazowych, produkowanych przez Zakład "Kemipol" o wspólnej nazwie PIX. Były to: PIX-112, PIX-123, PIX-122 oraz PIX-113. Dobrano najkorzystniejszy koagulant, wyznaczono jego optymalna dawkę oraz pH roztworu reakcyjnego (pH=5;9). Proces pogłębionego utleniania przeprowadzono dla ścieków różniących się kwasowością (pH=3,5 oraz pH=5), stosując różne dawki żelaza (Fe2+) zmieniane w zakresie od 0,1 g/dm3 do 0,8 g/dm3 zachowując stosunek stężeń Fe2+/H2O2 na poziomie 1:3. Z uwagi na zbyt niski stopień oczyszczania przedmiotowych wód pod-procesowych w obu przypadkach, uniemożliwiający ich odprowadzenie do zbiornika naturalnego lub kanalizacji, poddano je doczyszczeniu w procesie odwróconej osmozy. Efektywność procesów fizykochemicznego oczyszczania ścieków koksowniczych określono w oparciu o zmiany wartości zanieczyszczeń tj. chemicznego zapotrzebowanie tlenu oraz zawartości węgla organicznego i ogól-nego, stężenie indeksu fenolowego, cyjanków wolnych, siarczków oraz żelaza ogólnego.
The article discusses research aimed at comparing the effectiveness of treatment of waste-water from coke industry in the volume of coagulation and advanced oxidation using Fenton's reagent. In the case of the first of the methods tested four types of iron coagulants are produced by the Department "Kemipol" a common name of the PIX. These were: PIX-112 PIX-123, PIX and PIX-122-113. Selects the best possible coagulant, determined its optimal dose and pH of the reaction solution (pH = 5, 9). Advanced oxidation process was carried out for treatment different acidity (pH = 3.5 and pH = 5), using different doses of iron (Fe 2 +) changed from 0.1 g / dm 3 to 0.8 g / dm 3 while maintaining the ratio of the concentrations of Fe2 + / H2O2 at 1:3. Given the very low degree of purification of these waters in both cases, prevent their discharge into the natural reservoir or sewage, treated them in the process of thoroughly cleaning of reverse osmosis. The effectiveness of the physicochemical wastewater treatment processes of coke have been identified based on the evolution of pollutants such as chemical oxygen demand and organic carbon content and total concentration of phenol index, free cyanide, sulfides and iron general.
Źródło:
Inżynieria Ekologiczna; 2011, 24; 184-194
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biofiltracja jako metoda unieszkodliwiania odorów powstających podczas kompostowania frakcji biodegradowalnej odpadów komunalnych i przemysłowych
Neutralization of odors generated during composting of biodegradable fraction of municipal and industrial waste by biofiltration
Autorzy:
Kwarciak-Kozłowska, A.
Bańka, B.
Powiązania:
https://bibliotekanauki.pl/articles/297263.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
kompostowanie
odpady biodegradowalne
biofiltracja
odory
biofiltr
composting
biodegradable waste
biofiltration
odor
biofilter
Opis:
W artykule zaprezentowano zagadnienia związane z emisją związków zapachowych podczas kompostowania bioodpadów. Ze względu na skład gazów i charakter emitowanych związków w procesie kompostowania, a także niskie koszty i łatwą eksploatację biofiltracja wydaje się jedną z korzystniejszych metod dezodoryzacji w obiektach gospodarki odpadami. Biofiltracja wpisuje się w trend rozwoju zrównoważonego w dziedzinie neutralizacji zapachów drogą biologiczną bez używania reagentów chemicznych. Proces biologiczny opiera się na zasadzie reakcji utleniania związków w obecności tlenu i mikroorganizmów, dzięki czemu powstają biomasa, woda oraz produkty mineralne. Dzięki temu procesowi można uzyskać dobre efekty usuwania typowych zanieczyszczeń emitowanych z kompostowni (siarkowodór, amoniaki i lotne związki organiczne). Skuteczność usuwania H2S i amoniaku osiąga wartości bliskie 98%. W przypadku usuwania lotnych związków organicznych efektywność biofiltrów jest niższa i wynosi średnio 50%.
The paper presents the issues associated with the emission of aroma compounds during composting of biowaste. Biological methods for purification of air from volatile organic compounds such as biofiltration are effective and competitive in relation to the adsorption or absorption of thermal and catalytic combustion. This type of decontamination procedure does not require any substantial additional amounts of problematic substances and the quantities of waste generated is small. Due to the composition and nature of the gases emitted in the process of composting of the compounds, as well as low cost and easy operation of the biofiltration this method appears to be one of the more preferred ones in case of deodorization of waste management facilities. The essence of the biofilter is based on the degradation of contaminants by aerobic microorganisms contained in the filter material (biomass) disposed in the biofilter. Biological waste gas treatment is based on two main processes, which are the absorption of pollutants in water and biological decomposition of pollutants absorbed. Both processes take place at the same time and the effect of their common impact assessments is that the gases are purified by absorbing in the biological decomposition of pollutants sorbent regeneration. The purified gases might not involve inhibiting substances (including heavy metals or toxins), and their temperature must be within the range tolerated by the microorganisms colonizing the membrane biofilter filling. Decomposition of organic compounds using biofilters is carried out to CO2 and H2O with the participation of aerobic heterotrophic microorganisms. Autotrophic bacteria are capable of removing inorganic compounds from gases such as hydrogen sulfide and ammonia. Through this process you can get good results removing common pollutants emitted from the composting plant (hydrogen sulfide; ammonia and volatile organic compounds). The removal efficiency can reach 99% and 98% for hydrogen sulfide and ammonia respectively. In the case of the removal of volatile organic compounds biofilter efficiency is lower and amounts to an average of 50%.
Źródło:
Inżynieria i Ochrona Środowiska; 2014, 17, 4; 631-645
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of the organic fraction of pretreated leachate from old landfill after sonication exposure
Charakterystyka frakcji organicznej odcieków ze starego składowiska po zastosowaniu sonifikacji
Autorzy:
Kwarciak-Kozłowska, A.
Sławik-Dembiczak, L.
Powiązania:
https://bibliotekanauki.pl/articles/297739.pdf
Data publikacji:
2016
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
landfill leachate
IR spectra
ultrasound field
biodegradation
odcieki składowiskowe
spektroskopia IR
pole ultradźwiękowe
biodegradacja
Opis:
Collection of municipal waste in landfills, even properly designed and operated, is an important issue in environmental engineering. These are formed by the infiltration of rainfall through the waste bed and eluting with the organic and inorganic compounds, often toxic nature. So far, over 200, have been identified which are organic substances leachate contamination, as many as 35 belongs to the so-called “priority pollutants”. By the decrease in the concentration of organic compounds in the leachate decrease the value of biological and chemical oxygen demand which is dictated by stabilization of landfill as lengthening the time of its life. However, the indicator BOD5 decreases faster as compared to COD therefore BOD5/COD ratio is reduced to as low as 0.06. The leachate produced in mature landfills appears to be the presence of significant amounts of humic acid with very stable structure difficult to breach by bacteria. It was assumed that ultrasonic waves induce change in the structure of organic compounds and contribute to the acceleration of the biodegradability, among other substances in the effluents refractive thereby improve the efficiency of the biological purification processes. For sonification leachate used ultrasonic disintegrator type vibro goal Sonics (40 kHz). The range of vibration amplitude was varied in the range from 25 to 123 μm and exposure time (sonification of leachate) from 60 to 720 seconds. Also the measuring of the size of the energy produced during sonication sonochemical leachate was made. It was found, inter alia, that the sonification process of effluents clearly influenced the formation and release of aliphatic compounds. The –CH2 and –CH3 groups can be released from the humic compounds or aromatic combinations. It was also observed the formation of substantial amounts of compounds with the functional hydroxyl group, which might be derived from alcohols and carboxylic acids. These changes suggested a breach of the chemical structure of organic compounds contained in the leachate, so that, the chemical structure of the formed compounds was more susceptible to biodegradation. The study also determined the effect of ultrasonic field on the evolution of the BOD5 treated leachates and BOD5/COD ratio. The BOD5 sharp increase was observed at the time of sonification of leachate in the range of 60 to 300 s in the whole studied range of amplitudes. This suggests that by the action of the ultrasonic field generated in the effluents of chemical compounds had greater biodegradability.The process confirmed by the change in the ratio of BOD5/COD. The highest value of BOD5 indicator (460 mg/dm3) was at the time of subjecting the leachate impact of ultrasound using amplitude equal to the size of 25 μm and for the time of sonification equal 300 s. In this case the BOD5/COD factor increased to 0.12, and it was about 26% higher as compared to the value of this indicator for leachate no-sonificated (0.089).
Gromadzenie odpadów komunalnych na składowiskach, nawet prawidłowo zaprojektowanych i eksploatowanych, jest istotnym zagadnieniem w inżynierii środowiska z uwagi na problemy ochrony wód gruntowych przed zanieczyszczeniem odciekami. Odcieki powstają w wyniku infiltracji opadów atmosferycznych przez złoże odpadów i wymywanie z niego związków organicznych i nieorganicznych, niejednokrotnie o charakterze toksycznym. Dotychczas zidentyfikowano ponad 200 substancji organicznych będących zanieczyszczeniami odcieków, z których aż 35 należy do tzw. „priority pollutants”. W miarę upływu czasu wskutek obniżania się stężenia związków organicznych w odciekach zmniejszają się wartości biologicznego i chemicznego zapotrzebowania tlenu, co związane jest ze stabilizacją składowiska w miarę wydłużania czasu jego eksploatacji. Wskaźnik BZT5 szybciej maleje w porównaniu z ChZT, w związku z czym stosunek BZT5/ChZT ulega zmniejszeniu nawet do poziomu 0,06. W odciekach powstających na „starych” składowiskach odnotowuje się obecność znacznych ilości kwasów humusowych charakteryzujących się bardzo stabilną strukturą trudną do naruszenia przez bakterie. Dlatego też efektywność ich oczyszczania metodą biologiczną osadu czynnego lub fermentacji metanowej nie jest zbyt wysoka. Założono, że fale ultradźwiękowe wywołają zmianę struktury związków organicznych i przyczynią się do przyśpieszenia biodegradowalności, między innymi substancji refrakcyjnych w odciekach, dzięki czemu wzrośnie efektywność ich oczyszczania w procesach biologicznych. Do nadźwiękawiania odcieków użyto dezintegratora ultradźwiękowego typu Sonisc vibro cel (40 kHz). Zakres wartości amplitud drgań zmienił się od 25 do 123 μm, a czas ekspozycji (nadźwiękawiania odcieków) od 60 do 720 s. Podczas sonifikacji dokonywano również pomiaru wielkości energii sonochemicznej wytwarzanej podczas nadźwiękawiania odcieków. Stwierdzono m.in., że proces sonifikacji odcieków wyraźnie wpłynął na powstawanie i uwolnienie związków alifatycznych. Grupy –CH2 i –CH3 mogły być uwalniane ze związków humusowych lub połączeń aromatycznych; zaobserwowano również powstawanie znacznych ilości związków z grupą funkcyjną –OH, które mogły być pochodnymi alkoholi i kwasów karboksylowych. Zmiany te wskazują na naruszenia struktury chemicznej związków organicznych zawartych w odciekach, wskutek czego powstawały związki o strukturze chemicznej bardziej podatnej na proces biodegradacji. W badaniach określono także wpływ pola ultradźwiękowego na zmiany wskaźnika BZT5 oczyszczanych odcieków oraz na stosunek BZT5/ChZT. Wyraźny wzrost BZT5 obserwowano w momencie nadźwiękawiania odcieków w zakresie od 60 do 300 s w całym przebadanym zakresie amplitud. Sugeruje to, że wskutek oddziaływania pola ultradźwiękowego na odcieki powstają w nich związki chemiczne o większym stopniu biodegradowalności. Zachodzący proces potwierdziła zmiana wartości stosunku BZT5/ChZT. Najwyższą wartość 460 mg/dm3 wskaźnik BZT5 przyjął w momencie poddawania odcieków oddziaływaniu ultradźwięków przy zastosowaniu wielkości amplitudy równej 25 μm i dla czasu nadźwiękawiania 300 s. Współczynnik BZT5/ChZT w tym przypadku wzrósł do poziomu 0,12 i był on o 26% wyższy w porównaniu do wartości tego wskaźnika dla odcieków nienadźwiękawianych (0,089).
Źródło:
Inżynieria i Ochrona Środowiska; 2016, 19, 4; 561-575
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pretreatment of Stabilized Landfill Leachate Using Ozone
Autorzy:
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/124499.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
landfill leachate
ozonation
hydrogen peroxide
ultrasonic field
advanced oxidation process
Opis:
The paper presents the possibility of using the ozonation process in landfill leachate pretreatment. The study was conducted in three stages. In the first stage, the landfill leachate was subjected only to the ozone, with the dose varying from 10 mg/dm3 to 40 mg/dm3. As part of this stage of research, the effect of changes in the pH of wastewater undergoing the process of ozonation on the efficiency of TOC removal was examined. For all the tested pH values (pH = 3.5, pH = 7 pH = 8.5 pH = 10), the TOC removal rate constant (kRowo) during ozonization was determined. In the second stage of the study, the ozonation process was facilitated by UV radiation. Additionally in this stage, the rate of generation of OH• radicals was accelerated by the addition of hydrogen peroxide to the reactor. The COD: H2O2 ratio by weight was 1:2.5, 1:5 and 1:10 and 1:20. In the last stage of the study, we attempted to assist the ozonation process using ultrasonic field. The employed vibration amplitude amounted to 25μm and sonication time equalled 300 seconds. It was found that the ozonation process is the most effective at alkaline pH (8.5). The TOC removal efficiency was 37% (346 mg/dm3) after 60 minutes of ozonation. The best results of pollutants oxidation measured as COD and TOC removal were observed when the dose of ozone was 20 mg/dm3. The combination of sonication and ozonation has resulted in a reduction of COD and TOC values by 370 mg/dm3 and 126 mg/3, respectively, in comparison to the ozonation process alone. It was found that the most effective process in landfill leachate treatment is the combination of ozonation with hydrogen peroxide addition (COD:H2O2=1:10). The COD, TOC and BOD values were 65%, 62% and 36% lower, respectively, in comparison to ozonation process conducted alone.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 186-193
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Application of Integrated System in Dairy Wastewater Treatment
Zastosowanie zintegrowanego system w oczyszczaniu ścieków mleczarskich
Autorzy:
Kwarciak-Kozłowska, A.
Gałwa-Widera, M.
Bień, J.
Powiązania:
https://bibliotekanauki.pl/articles/1813672.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
dairy wastewater
photocatalysis
TiO2
ZnO
advanced oxidation process
ultrafiltration
ścieki mleczarskie
fotokataliza
zaawansowane metody utleniania
ultrafiltracja
Opis:
The study presented the results of the examinations obtained during treatment of dairy wastewater in a membrane photoreactor where photocatalysis was sequentially combined with low-pressure membrane process. The aim of the study was to determine the effectiveness of degradation of the contaminants contained in such wastewater during photocatalysis and in the arrangement that combined photocatalysis with ultrafiltration. Several experiments were performed in order to determine the most beneficial conditions of the photocatalysis process, e.g. the dose of the photocatalysts used (TiO2 and ZnO), duration of the process and pH of wastewater subjected to oxidation. The dose of titanium dioxide was changed from 1 to 40 g/dm3, whereas the content of zinc oxide ranged from 1 to 6 g/dm3. The results obtained in the study showed that the extension of the irradiation time to over 30 minutes (TiO2) and over 45 minutes (ZnO) during photocatalysis does not lead to increased removal of contaminants from the dairy wastewater. It was also demonstrated that the increase in the doses of both photocatalysts does not lead to the increase in the efficiency of their treatment. In the case of treatment of dairy wastwater with TiO2, the photocatalysis occurred most effectively for its dose of 10 g/dm3. Removal rates for COD, TOC and total nitrogen were 58% (1670 mg/dm3), 62% (450 mg/dm3) and 56% (128 mg/dm3), respectively. Replacing titanium dioxide with zinc oxide (ZnO – 2 g/dm3) in the photocatalysis process allowed for obtaining higher degrees of removal of contaminants determined as COD, TOC and total nitrogen to the level of 77.8% (870 mg/dm3), 62% (445 mg/dm3) and 52% (139 mg/dm3), respectively. Since both photocatalysts were supplied to the photoreactor in the form of a suspension, the membrane in the next reactor represented an efficient barrier for their particles. It was observed that higher volumetric stream of the permeate was obtained during the process of low-pressure membrane filtration of sewage initially treated in the process of photocatalysis with titanium dioxide (4.6·10-5 m3/m2·s – TiO2 and 4.1·10-5m3/m2·s – ZnO). It was found that the ultrafiltration process in the case of the feed material with TiO2 led to the reduction in COD, TOC and total nitrogen by 78% (370 mg/dm3), 72% (126 mg/dm3) and 40% (80 mg/dm3). Slightly better quality of permeate was obtained when the feed material contained ZnO powder. Degree of retention of the contaminants COD, TOC and total nitrogen were 68% (280 mg/dm3), 66% (143 mg/dm3) and 42% (76 mg/dm3), respectively.
W pracy zaprezentowano wyniki badań jakie otrzymano podczas oczyszczania ścieków mleczarskich w fotoreaktorze membranowy w którym sekwencyjnie skojarzono procesy fotokatalizę z niskociśnieniowym procesem membranowymi. Celem badań było określenie skuteczności degradacji zanieczyszczeń znajdujących się w tego rodzaju wodach odpadowych w samodzielnie prowadzonym procesie fotokatalizy jak również w układzie kojarzącym go z procesem ultrafiltracji. Przeprowadzono szereg eksperymentów w celu ustalenia najkorzystniejszych warunków prowadzenia procesu fotokatalizy tj. dawka zastosowanych fotokatalizatorów (TiO2 i ZnO), czas prowadzenia procesu oraz wartość pH ścieków poddawanych utlenianiu. Dawkę ditlenku tytanu zmieniano w zakresie od 1 do 40 g/dm3 a tlenku cynku od 1 do 6 g/dm3. Na podstawie uzyskanych wyników badań stwierdzono, że wydłużanie czasu naświetlania powyżej 30 minut (TiO2) oraz powyżej 45 min (ZnO) w procesie fotokatalizy nie wpływa na zwiększanie usunięcia zanieczyszczeń z oczyszczanych ścieków mleczarskich. Wykazano również, że zwiększanie stosowanych dawek obu fotokatalizatorów nie skutkuje wzrostu efektywności ich oczyszczania. W przypadku oczyszczania ścieków mleczarskich z TiO2 proces fotokatalizy przebiegał najkorzystniej jego dawce wynoszącej 10 g/dm3. Stopień usunięcia ChZT, OWO i azotu ogólnego wynosił odpowiednio 58% (1670 mg/dm3), 62% (450 mg/dm3) i 56% (128 mg/dm3). Zastąpienie ditlenku tytanu tlenkiem cynku (ZnO – 2g/dm3) w procesie fotokatalizy pozwoliło na uzyskanie wyższych stopni usunięcia zanieczyszczeń oznaczanych jako ChZT, OWO i azotu ogólnego odpowiednio do poziomu 77.8% (870 mg/dm3), 62% (445 mg/dm3) i 52% (139 mg/dm3). Z uwagi na fakt, że oba dawkowano do fotoreaktora w formie zawiesiny to znajdująca się w kolejnym reaktorze membrana była skuteczną barierę dla ich cząstek. Zaobserwowano, że wyższy objętościowy strumień permeatu uzyskano w trakcie prowadzenia procesu niskociśnieniowej filtracji membranowej ścieków wstępnie podczyszczonych w procesie fotokatalizy z ditlenkiem tytanu (4,6·10-5 m3/m2·s – TiO2 i 4,1·10-5 m3/m2·s – ZnO). Stwierdzono że wykorzystany proces ultrafiltracji w przypadku nadawy z TiO2 przyczynił się do obniżenia wartości wskaźników ChZT, OWO i azotu ogólnego odpowiednio o 78% (370 mg/dm3), 72 % (126 mg/dm3) i 40% (80 mg/dm3). Nieznacznie lepszej jakości permeat otrzymano, gdy nadawa zawierała proszek ZnO. Stopień retencji zanieczyszczeń ChZT, OWO i azotu ogólnego wynosił odpowiednio 68% (280 mg/dm3), 66 % (143 mg/dm3) i 42% (76 mg/dm3).
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 1; 602-615
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of UASB reactor in meat industry wastewater treatment
Zastosowanie reaktora UASB do oczyszczania ścieków z zakładów mięsnych
Autorzy:
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Mielczarek, K.
Krzywicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/395840.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków z zakładów mięsnych
reaktor UASB
biogaz
meat industry wastewater
reactor UASB
hydraulic retention time
biogas
Opis:
The meat industry is a branch of the food sector, which significantly affects the degradation of the environment. Consuming large amounts of water consequently produces significant quantities of water which are characterised by a high organic content and high concentration of suspended solids, inorganic salts and nutrients. The study attempted to determine the influence of the HRT and OLR on biogas production and the treatment of wastewater from the meat industry, and it was found that the most preferred treatment process carried out was at HRT 3d (OLR-0.55 kgCOD/m3d). The anaerobic process under HRT 3d obtained a considerable degree of the removal of organic pollutants from raw wastewater designated as COD (79%), BOD (77%) and TOC (73%). The concentrations of COD and BOD were 350 mg/dm3 and 363 mg/dm3 respectively. The value of TOC reached a level of 142 mg/dm3. Due to its poor quality, effluent from a UASB reactor cannot be discharged into natural water without additional treatment processes. The addition of reverse osmosis in the meat industry wastewater treatment is suggested.
W badaniach podjęto próbę określenie wpływu czasu zatrzymania ścieków z zakładu mięsnego w reaktorze UASB na efektywność ich oczyszczania oraz na wielkość dobowej produkcji biogazu. HRT zmieniano w zakresie od 2 do 6 dób co wiązało się ze zmianą obciążenia komory ładunkiem zanieczyszczeń z 0,27 kgChZT/m3d do 0,82 kgChZT/m3d. Stwierdzono, że wraz ze skracaniem czasu zatrzymania z 6d do 2d, jakość ścieków ulega pogorszeniu, ale ilość produkowanego biogazu zwiększała się. Zaobserwowano, że wielkość współczynnika biogazu ulegała obniżeniu. Stwierdzono, że najkorzystniej prowadzić proces oczyszczania badanych ścieków przy HRT równym 3 doby z uwagi na dobre efekty oczyszczania i wysoki współczynnik produkcji biogazu wynoszący 0,45 dm3 biogazu/gChZT_us. Prowadzenie procesu fermentacji przy tak ustalonych warunkach pozwoliło na wysoki stopień usunięcia zanieczyszczeń oznaczanych, jako ChZT (79%), BZT5 (77%) i OWO (73%). Stężenie ChZT ścieków oczyszczonych wynosiło 350 mg/dm3, BZT5 463mg/dm3 a OWO 142 mg/dm3. Pomimo wysokiego stopnia usunięcia zanieczyszczeń z badanych ścieków nie ma jednak możliwości odprowadzenia ich do odbiornika naturalnego. Proponuje się, aby w kolejnych etapach badań podjąć próbę doczyszczania ścieków w procesie odwróconej osmozy co w przyszłości może pozwolić na zamknięcie obiegu wody na terenie zakładu.
Źródło:
Civil and Environmental Engineering Reports; 2011, 7; 119-128
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Toxicity assessment of treated meat industry wastewater in the anaerobic process
Ocena toksyczności ścieków z przemysłu mięsnego oczyszczonych w procesie beztlenowym
Autorzy:
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/296776.pdf
Data publikacji:
2017
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
meat industry wastewater
toxicity
Lepidium test
ASBR reactor
biogas purification
ścieki z zakładu mięsnego
toksyczność
test Lepidium
reaktor ASBR
oczyszczanie biogazu
Opis:
Major pollutant components of meat processing wastewater are biodegradable organic compounds, fats and proteins in both particulate and dissolved forms. Because of the possible pollution of water sources, the efficient disposal of effluent from meat plants is important. The treatment of industrial wastewater is a highly complex process that generally involves factors associated with load fluctuations and high concentrations of organic matter. Toxic effects on aquatic organisms and plants may be caused by numerous nitrogen compounds, as well as detergents and antibiotics, in the meat industry wastewater. The aim of the research was to determine the toxicity of anaerobic treated meat industry wastewaters. The level of toxicity was determined with algae growth inhibition test and Lepidium test. The values of ErC50 (0÷96) and EbC50 of indicators were 18.4 and 8.6% respectively. TU value for ErC50 was 5.51 which meant acute toxicity of wastewater. The value of TU for EbC50 was 11.62 (high toxicity of wastewater). The values of indicators RSG (relative seed germination), RRG (relative root growth) and GI (germination index) were 92, 19.5 and 17.62% respectively. Treatment efficiency meat industry wastewater during fermentation process was very high. The COD and BOD removal efficiency were on 82.3 and 80% respectively. Effluent from ASBR reactor had following parameters: COD - 206 mg O2/dm3 and BOD - 130 mg/dm3. TOC value after anaerobic process was 75 mg C/dm3 (78.1%). The concentration of ether extract and proteins were 188 and 74 mg/dm3respectively. Generated biogas in the methane fermentation process of wastewater from meat industry plants was characterized by a high methane content (77.5% vol.). Carbon dioxide and the ballast in the analyzed biogas were 20 and 2.5% respectively. In order to enrich biomass with methane by removal of CO2 from its content, the gas generated in the anaerobic process was subjected to the processes of chemisorption and adsorption on the granulated active carbons and molecular sieve. Purification the raw biogas by a molecular sieve has contributed to the increase of methane in enriched from 77.5 to 92.6% and the removal of CO2 from 20 to 5.7%. Due to poor quality and its high toxicity, effluent from ASBR reactor can not to be discharged into natural water. In the future it is suggested to incorporate RO or UF into the technological system in order to posttreatment the wastewater.
Głównymi zanieczyszczeniami obecnymi w ściekach powstających na terenie zakładu mięsnego są biodegradowalne związki organiczne, tłuszcze i białka, występujące w nich zarówno w formie cząstek stałych, jak i rozpuszczonych. Ze względu na możliwość zanieczyszczenia nimi naturalnych odbiorników ważne jest skuteczne oczyszczanie tego rodzaju ścieków poprodukcyjnych. Oczyszczanie ścieków przemysłowych jest bardzo złożonym procesem, na który wpływa wiele czynników, m.in. wysokie stężenie materii organicznej w ściekach, jak również duże ich wahania. Działanie toksyczne na organizmy wodne i rośliny może być spowodowane przez występujące w ściekach z przemysłu mięsnego związki azotu, a także detergenty i antybiotyki. Celem badań było określenie toksyczności beztlenowo oczyszczonych ścieków z przemysłu mięsnego. Poziom ich toksyczności określono za pomocą testu zahamowania wzrostu glonów oraz testu Lepidium. Wartości wskaźników ErC50 (0-96) i EbC50 wynosiły odpowiednio 18,4 i 8,6%. Wartość TU dla ErC50 wynosiła 5,51, co oznaczało ostrą toksyczność ścieków. Wartość TU dla EbC50 wynosiła 11,62 (wysoka toksyczność ścieków). Wartości wskaźników RSG (względne kiełkowanie nasion), RRG (względny wzrost korzeni) oraz GI (wskaźnik kiełkowania) wynosiły odpowiednio 92, 19,5 i 17,62%. Efektywność oczyszczania ścieków z przemysłu mięsnego w procesie fermentacji metanowej była bardzo wysoka. Stopień usunięcia ChZT i BZT5 był na poziomie odpowiednio 82,3 i 80%. Odpływ z reaktora ASBR charakteryzował się następującymi wartościami: ChZT - 206 mg/dm3 i BZT5 - 130 mg/dm3. Wartość OWO po procesie beztlenowym obniżyła się do poziomu 75 mg C/dm3 (78,1%). Stężenie ekstraktu eterowego i białek w ściekach oczyszczonych wynosiło odpowiednio 188 i 74 mg/dm3. Wytworzony w procesie fermentacji metanowej ścieków z zakładu mięsnego biogaz charakteryzował się wysoką zawartością metanu (77,5% obj.). Zawartość ditlenku węgla i balastu w analizowanym biogazie wynosiła odpowiednio 20 i 2,5%. W celu wzbogacenia biogazu w metan poprzez usunięcie z jego zawartości CO2 wytworzony w procesie beztlenowym gaz poddano procesom chemisorpcji i adsorpcji na granulowanych węglach aktywnych oraz na sicie molekularnym. Oczyszczanie surowego biogazu za pomocą sita molekularnego przyczyniło się do wzrostu zawartości metanu z 77,5 do 92,6% przy jednoczesnym usunięciu CO2 z 20 do 5,7%. Z powodu jednak złej jakości odpływu z reaktora ASBR oraz jego wysokiej toksyczności ścieki tak oczyszczone nie mogą być odprowadzane do odbiornika naturalnego. W przyszłości w celu ich doczyszczania sugeruje się włączenie procesu RO lub UF do układu technologicznego.
Źródło:
Inżynieria i Ochrona Środowiska; 2017, 20, 4; 509-523
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of meat industry wastewater using coagulation and Fentons reagent
Oczyszczanie ścieków zakładów mięsnych w procesie koagulacji i z zastosowaniem odczynnika Fentona
Autorzy:
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Mielczarek, K.
Krzywicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/395853.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
koagulacja
odczynnik Fentona
zakłady mięsne
meat industry wastewater
coagulation process
Fenton process
PIX 113
PAX XL 19
Opis:
The aim of the paper was to study meat industry wastewater treatment efficiency during chemical processes. The research was carried out in two steps. The first step was the coagulation process and the second step was the Fenton reaction. It was found that wastewater treatment with the use of Fenton's reagent achieved a higher degree of removal of the pollutants determined as COD, TOC and TN in comparison to the coagulation of PIX 113. The most profitable dose of the Fenton's reagent was 0.6/1.8 Fe2+/H2O2 g/dm3. The degree of COD removal from the wastewater with the use of the Fenton's reagent was higher by 10% on average compared to PIX 113. TOC and TN removal efficiency, using the Fenton's reagent was higher by 13% and 40.5% respectively when compared to the coagulation process. The aim of the paper was to study meat industry wastewater treatment efficiency during chemical processes. The research was carried out in two steps. The first step was the coagulation process and the second step was the Fenton reaction. It was found that wastewater treatment with the use of Fenton's reagent achieved a higher degree of removal of the pollutants determined as COD, TOC and TN in comparison to the coagulation of PIX 113. The most profitable dose of the Fenton's reagent was 0.6/1.8 Fe2+/H2O2 g/dm3. The degree of COD removal from the wastewater with the use of the Fenton's reagent was higher by 10% on average compared to PIX 113. TOC and TN removal efficiency, using the Fenton's reagent was higher by 13% and 40.5% respectively when compared to the coagulation process.
W badaniach porównano efektywności oczyszczania ścieków powstających podczas uboju i przetwórstwa mięsa w procesie koagulacji oraz w procesie utleniania z zastosowaniem odczynnika Fentona. W procesie koagulacji wykorzystano dwa rodzaje koagulantów (PIX 113 i PAX XL 19). Stwierdzono, że stopień usunięcia ChZT przy użyciu PIX 113 był średnio o 9% wyższy w porównaniu do PAX XL 19. Stosując wyznaczoną jako najkorzystniejszą dawkę PIX 113 wynoszącą 0,6 g/dm3 ścieki po procesie koagulacji charakteryzowały się wartością ChZT, OWO i CA odpowiednio na poziomie 836 mg/dm3, 363 mg/dm3 i 359 mg/dm3. Porównując efektywność usunięcia zanieczyszczeń z oczyszczanych ścieków stwierdzono, że korzystniej prowadzić chemiczny proces ich oczyszczania z zastosowanie odczynnika Fentona. Jako najkorzystniejszą dawkę odczynnika Fentona wyznaczono 0,6/1,8 Fe2+/H2O2 g/dm3. Wartość ChZT ścieków oczyszczonych na drodze koagulacji oraz z zastosowaniem odczynnika Fentona wynosiła odpowiednio 515 mg/dm3 i 834 mg/dm3. Stopień usunięcia OWO ze ścieków z zastosowaniem odczynnika Fentona był średnio o 13% wyższy w porównaniu do procesu koagulacji. Stężenie OWO ścieków oczyszczonych w przypadku reakcji Fentona było na poziomie 241,4 mg/dm3 a po procesie koagulacji 363 mg/dm3. Przeprowadzone badania pokazały również, że pomimo wysokiego stopnia usunięcia zanieczyszczeń ścieki oczyszczone w obu procesach chemicznych nie mogą być odprowadzone do odbiornika naturalnego. Po obu procesach wartość ChZT ścieków oczyszczonych była prawie 7-krotnie (proces koagulacji) i 4- krotnie (reakcja Fentona) przekroczona w stosunku do dopuszczalnych wartości. Wartość OWO po procesie koagulacji i Fentona została przekroczona odpowiednio 12 i 8-krotnie. Prawie 5-krotnie (odczynnik Fentona) i 12-krotnie (proces koagulacji) w ściekach oczyszczonych została przekroczona wartość azotu całkowitego. Z uwagi na to sugeruje się łączenie tych procesów z innym procesami jednostkowymi np. procesem biologicznym lub ciśnieniowymi technikami membranowymi.
Źródło:
Civil and Environmental Engineering Reports; 2011, 6; 45-58
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies