Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kwarciak, K." wg kryterium: Autor


Wyświetlanie 1-13 z 13
Tytuł:
A greedy algorithm for the DNA sequencing by hybridization with positive and negative errors and information about repetitions
Autorzy:
Kwarciak, K.
Formanowicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/202322.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DNA sequencing
l-mer multiplicity
greedy algorithm
combinatorial problems
Opis:
In this paper a greedy algorithm for some variants of the sequencing by hybridization method is presented. In the standard version of the method information about repetitions is not available. In the paper it is assumed that a partial information of this type is a part of the problem instance. Here two simple but realistic models of this information are taken into consideration. The first one assumes it is known if a given element of a spectrum appears in the target sequence once or more than once. The second model uses the knowledge is a given element of a spectrum occurs in the analyzed sequence once, twice or at least three times. The proposed greedy algorithm solves the variant of the problem with positive and negative errors. Results of a computational experiment are reported which, among others, confirm that the additional information leads to the improvement of the obtained solutions. They also show that the more precise model of information increases the quality of reconstructed sequences.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 1; 111-115
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie efektywności oczyszczania poprocesowych wód koksowniczych z zastosowaniem procesów koagulacji oraz pogłębionego utleniania
Comparing the effectiveness of treatment coking industry wastewater with applying for the coagulation process and advanced oxidation processes
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/400981.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki koksownicze
koagulacja objętościowa
koagulanty PIX
pogłębione utlenianie
odczynnik Fentona
odwrócona osmoza
coke wastewater
volumetric coagulation
coagulants-PIX
advanced oxidation processes
reagent Fenton
reverse osmosis
Opis:
W artykule omówiono badania, których celem było porównanie efektywności oczyszczania ścieków z przemysłu koksowniczego w procesach koagulacji objętościowej i pogłębionego utleniania z zastosowaniem odczynnika Fentona. W przypadku z pierwszej z metod przebadano 4 rodzaje koagulantów żelazowych, produkowanych przez Zakład "Kemipol" o wspólnej nazwie PIX. Były to: PIX-112, PIX-123, PIX-122 oraz PIX-113. Dobrano najkorzystniejszy koagulant, wyznaczono jego optymalna dawkę oraz pH roztworu reakcyjnego (pH=5;9). Proces pogłębionego utleniania przeprowadzono dla ścieków różniących się kwasowością (pH=3,5 oraz pH=5), stosując różne dawki żelaza (Fe2+) zmieniane w zakresie od 0,1 g/dm3 do 0,8 g/dm3 zachowując stosunek stężeń Fe2+/H2O2 na poziomie 1:3. Z uwagi na zbyt niski stopień oczyszczania przedmiotowych wód pod-procesowych w obu przypadkach, uniemożliwiający ich odprowadzenie do zbiornika naturalnego lub kanalizacji, poddano je doczyszczeniu w procesie odwróconej osmozy. Efektywność procesów fizykochemicznego oczyszczania ścieków koksowniczych określono w oparciu o zmiany wartości zanieczyszczeń tj. chemicznego zapotrzebowanie tlenu oraz zawartości węgla organicznego i ogól-nego, stężenie indeksu fenolowego, cyjanków wolnych, siarczków oraz żelaza ogólnego.
The article discusses research aimed at comparing the effectiveness of treatment of waste-water from coke industry in the volume of coagulation and advanced oxidation using Fenton's reagent. In the case of the first of the methods tested four types of iron coagulants are produced by the Department "Kemipol" a common name of the PIX. These were: PIX-112 PIX-123, PIX and PIX-122-113. Selects the best possible coagulant, determined its optimal dose and pH of the reaction solution (pH = 5, 9). Advanced oxidation process was carried out for treatment different acidity (pH = 3.5 and pH = 5), using different doses of iron (Fe 2 +) changed from 0.1 g / dm 3 to 0.8 g / dm 3 while maintaining the ratio of the concentrations of Fe2 + / H2O2 at 1:3. Given the very low degree of purification of these waters in both cases, prevent their discharge into the natural reservoir or sewage, treated them in the process of thoroughly cleaning of reverse osmosis. The effectiveness of the physicochemical wastewater treatment processes of coke have been identified based on the evolution of pollutants such as chemical oxygen demand and organic carbon content and total concentration of phenol index, free cyanide, sulfides and iron general.
Źródło:
Inżynieria Ekologiczna; 2011, 24; 184-194
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling performance in reverse osmosis wastewater treatment post-trial coke in the integrated systems based on the assumptions of the relaxation model
Modelowanie wydajności procesu odwróconej osmozy w oczyszczaniu poprocesowych wód koksowniczych w układzie zintegrowanym w oparciu o założenia modelu relaksacyjnego
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/395870.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków koksowniczych
koagulacja objętościowa
model relaksacyjny
odwrócona osmoza
coking wastewater
volume coagulation
advanced oxidation
relaxation model
reverse osmosis
Opis:
The paper presents the results of studies on coking wastewater, coming from the coke plant "Koksownia Czestochowa Nowa" in two integrated systems associating coagulation volume and advanced oxidation with reverse osmosis. The process of coagulation were performed using iron sulfate (III), (PIX 113) of 400 mg/dm3 and wastewater acidity at pH = 9. The second processes - advanced oxidation was carried out using Fenton's reagent. The concentration of iron (II) was 0.8 g/dm3 and hydrogen peroxide 2.4 g/dm3. Coke post-process water after its initial treatment was subjected to high-pressure membrane filtration. In the process of reverse osmosis a flat polyamide membrane ADF of Osmonics was used. Transmembrane pressure was 2 MPa and the linear speed of water on the membrane surface of 2m/s. Comparison of the effectiveness of wastewater treatment in both tested systems has shown that the system combining the advanced oxidation with reverse osmosis is more effective. In addition, this study attempts to model effectiness of the process of reverse osmosis in both studied systems, based on the assumptions of a relaxation model. An experimentally determined dependence of changes in volume of treated wastewater fluxes from the time of the high-pressure membrane filtration, and the values of time constant efficiency of the process characterized by a decrease to below economic viability allowed us fo verify this model.
W pracy zaprezentowano wyniki badań oczyszczania ścieków koksowniczych, pochodzących z zakładu koksowniczego "Koksownia Częstochowa Nowa", w dwóch układach zintegrowanych kojarzących koagulację objętościową oraz pogłębione utlenianie z procesem odwróconej osmozy. Proces koagulacji realizowano z zastosowaniem siarczanu żelaza (III), (PIX 113) o dawce 400 mg/dm3 i pH ścieków na poziomie pH=9. Drugi z procesów - pogłębione utlenianie przeprowadzono stosując odczynnik Fentona. Stężenie jonów żelaza (II) wynosiło 0,8 g/dm3 natomiast nadtlenku wodoru 2,4 g/dm3. Poprocesowe wody koksownicze po ich wstępnym oczyszczeniu poddawano wysokociśnieniowej filtracji membranowej. W procesie odwróconej osmozy stosowano poliamidową membranę płaską ADF amerykańskiej firmy Osmonics. Ciśnienie transmembranowe wynosiło 2 MPa natomiast liniowa prędkość ścieków nad powierzchnią membrany 2m/s. Porównanie efektywności oczyszczania przedmiotowych ścieków w obu układach badawczych wykazało, że skuteczniejszym okazał się system łączący pogłębione utlenianie z odwrócona osmozą. Ponadto w niniejszej pracy podjęto próbę modelowania wydajności procesu odwróconej osmozy w obu przebadanych układach w oparciu o założenia modelu relaksacyjnego. Wyznaczone na drodze doświadczalnej zależności zmiany wielkości strumieni oczyszczanych ścieków od czasu prowadzenia wysokociśnieniowej filtracji membranowej oraz wartości stałych czasowych charakteryzujących spadek wydajności procesu poniżej opłacalności ekonomicznej pozwoliły na weryfikację tego modelu.
Źródło:
Civil and Environmental Engineering Reports; 2011, 6; 19-32
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Polysulfone Membranes for Coke-Making Wastewater Treatment
Membrany polisulfonowe w oczyszczaniu ścieków koksowniczych
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/388945.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
oczyszczanie ścieków koksowniczych
układy zintegrowane
ciśnieniowe techniki membranowe
cokemaking wastewater treatment
integrated system
membranes pressure techniques
Opis:
Considering the complicated and variable type of coke-making sewages their purification strategy is difficult to generalize and it requires an integrated system, which joins biological and physicochemical separated processes. In the paper the researches were presented, which purpose was to define the efficiency of purifying matting pressure membrane techniques – ultrafiltration and reverse osmosis. In the process of low-pressure filtration flat membranes, applied in the laboratory, were different in terms of compactness of structure and porosity.
Ze względu na złożony i zmienny skład ścieków koksowniczych strategia ich oczyszczania jest trudna do uogólnienia i wymaga prowadzenia tego procesu w układach zintegrowanych, kojarzących biologiczne i fizykochemiczne procesy jednostkowe. W artykule omówiono badania, których celem było określenie efektywności oczyszczania ścieków koksowniczych w układzie kojarzącym ciśnieniowe techniki membranowe, a mianowicie ultrafiltrację i odwróconą osmozę. W procesie niskociśnieniowej filtracji zastosowano wytwarzane w laboratorium płaskie membrany polisulfonowe różniące się zwartością struktury i porowatością.
Źródło:
Ecological Chemistry and Engineering. A; 2011, 18, 12; 1751-1762
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie ścieków koksowniczych w układzie zintegrowanym łączącym proces koagulacji z ciśnieniowymi technikami membranowymi
Coking wastewater treatment in the integrated system coagulation - pressure membrane techniques
Autorzy:
Mielczarek, K.
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1819445.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
ścieki koksownicze
techniki membranowe
coking wastewater
membrane technology
Opis:
Z uwagi na ograniczone zasoby gazu i ropy naftowej podstawowym surowcem energetycznym w Polsce jest nadal węgiel kamienny, wykorzystywany m.in. do produkcji paliw koksowniczych w procesie pirolizy [1]. Jak wiadomo zakłady koksownicze niekorzystnie oddziaływają na środowisko naturalne między innymi z uwagi na generowanie podprocesowych wód koksowniczych obciążonych trudno biodegradowalnymi (BZT5/ChZT<0,02) substancjami toksycznymi [2]. W ich skład wchodzą między innymi: wielopierścieniowe węglowodory aromatyczne, związki heterocykliczne, oleje, substancje smołowe oraz związki nieorganiczne tj.: cyjanki, siarczki, siarczany, tiosiarczany, amoniak, a także jony metali ciężkich [3]. Z tego też względu ścieki koksownicze przed odprowadzeniem do odbiornika powinny być poddane procesowi oczyszczania. W zależności od rodzaju zanieczyszczeń metody ich oczyszczania powinny być tak dobrane, aby przy jak najniższych nakładach finansowych zapewnić najwyższy stopień usunięcia zanieczyszczeń. Zwiększenie efektywności oczyszczania ścieków wiąże się z rozbudową systemów ich oczyszczania o nowe procesy jednostkowe lub sprowadza się do modyfikacji układów już pracujących. Z uwagi na coraz bardziej złożony skład przemysłowych strumieni odpadowych do ich oczyszczania stosuje się układy zintegrowane kojarzące odpowiednie procesy jednostkowe. Wśród metod fizyczno-chemicznych stosowanych w przypadku ścieków obciążonych zanieczyszczeniami występującymi w postaci koloidów i drobnej zawiesiny bardzo często wykorzystywany jest proces koagulacji. Obiecującym rozwiązaniem w oczyszczaniu ścieków koksowniczych wydaje się być zastosowanie układu zintegrowanego łączącego koagulację z ultrafiltracją i odwróconą osmozą [4÷6]. W pracy omówiono wpływ procesu koagulacji na poprawę efektywności oczyszczania poprocesowych wód koksowniczych w układzie łączącym ciśnieniowe techniki membranowe tj. ultrafiltrację z odwróconą osmozą.Podjęto również próbę określenia możliwości prognozowania wielkości ultrafiltracyjnych strumieni permeatów zarówno w procesie oczyszczania ścieków koksowniczych w układzie łączącym ciśnieniowe procesy membranowe jak i w przypadku kiedy wody poprocesowe były wstępnie podczyszczane metodą koagulacji.
The paper presents results of studies aimed at determining the effectiveness of coking wastewater treatment in two integrated systems. In one system wastewater is treated using combined processes of ultrafiltration and reverse osmosis. In the second system, to increase the efficiency of wastewater treatment, an additional step of treatment is introduced - initial volume coagulation. Low-pressure membrane filtration process was carried out on membrane made of polysulfone 16% by weight. The participation of film-forming polymer in solution and during the evaporation of the solvent from the membrane surface equal to 5 s. The introduction of coking wastewater pretreatment by coagulation method resulted in the removal of such contaminants which are present mainly in the form of colloidal and macromolecular substances and thus provided a more efficient membrane ultrafiltration in the next stage of purification. Treatment of wastewater after the filtration process was performed by low-pressure reversed osmosis on membrane of polyamidetype ADF's Osmonics. Basing on assumptions of relaxation model, describing the changes in permeate flux during membrane filtration system carried out in non-stationary system, attempt to determine the possibilities of predicting the size of ultrafiltration permeate fluxes was made.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1965-1984
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie reaktora ASBR do oczyszczania ścieków z przemysłu mięsnego
Application of anaerobic sequencing batch reactor asbr for treatment of wastewater from meat industry
Autorzy:
Kwarciak-Kozłowska, A.
Mielczarek, K.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1819446.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
reaktor ASBR
ścieki
przemysł mięsny
ASBR reactor
sludge
meat industry
Opis:
Intensywny rozwój sektora spożywczego w Polsce odnotowano po roku 2004. Dotacje z Unii Europejskiej umożliwiły wiele inwestycji, a także zwiększenie produkcji oraz poprawy jakości produktów. Przemysł mięsny w kraju tworzy obecnie około 3500 przedsiębiorstw o różnych zakresach oraz profilach działalności. Ten dział gospodarki charakteryzuje się silnym rozdrobnieniem oraz rozproszeniem i obejmuje zarówno małe firmy rodzinne zajmujące się wyłącznie ubojem, jak również wielkie zakłady i spółki [1÷3]. Jednym z podstawowych problemów związanych z ochroną środowiska w zakładach mięsnych jest problem zagospodarowania i unieszkodliwienia powstających ścieków oraz odpadów. Nieoczyszczone ścieki odprowadzane do odbiornika mogą naruszyć jego równowagę lub całkowicie zdegradować [2, 4, 7]. W badaniach podjęto próbę określenie możliwości wykorzystania beztlenowego sekwencyjnego bioreaktora typu ASBR do produkcji biogazu i oczyszczanie ścieków z przemysłu mięsnego. Jak wiadomo procesy anaerobowe pozwalają nie tylko na rozwiązanie problemu ekologicznego, jakim jest unieszkodliwienie ścieków, ale również zapewniają korzyści ekonomiczne wynikające z produkcji wysokoenergetycznego gazu fermentacyjnego [8, 9].
The meat industry is a branch of the food sector, which significantly affects the degradation of the environment. Consuming large amounts of water consequently, also produces significant quantities of wastewater which is characterized by a high organic content and high concentration of suspended solids, inorganic salts and nutrients. The study attempted to determine the possibility of using ASBR for biogas production and treatment of wastewater from the meat industry. Anaerobic sludge concentration was on level of 20 g/dm3. Organic loading rates (OLR) were 1.25 kg COD/m3.d and sludge loading 0.06 kg COD/kg.d. During operation of ASBR there are four phases (filling - 0.5 h, the reaction - 22.5 h, sedimentation - 0.5 h and decantation - 0.5 h). The treatment wastewater were kept in ASBR for 24 hour (time of entire cycle). The research was conducted until the repeatable cycles. The repeatable cycles were extracted after three work cycles of ASBR. During methane fermentation process a considerable degree of removal of organic pollutants from raw wastewater was obtained: COD (73.3%), BOD5 (71.4%) and TOC (83.2%). The concentration of COD and BOD5 was respectively 435 mg/dm3 and 443 mg/dm3. The value of TOC reached level of 136 mg/dm3. Generated biogas in the methane fermentation process of wastewater from meat industry plant was characterized by high methane content (80.9% vol.). Processes in ASBR contributed to reduction of the number of bacteria (66.6% of mesophilic bacteria and 70.9% of psychrophilic bacteria).
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1891-1904
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Membrany polisulfonowe w oczyszczaniu ścieków koksowniczych
Application of polysulfone membranes for coke-making wastewater treatment
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/126367.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
oczyszczanie ścieków koksowniczych
układy zintegrowane
ciśnieniowe techniki membranowe
polisulfonowe membrany ultrafiltracyjne
cokemaking wastewater treatment
membrane pressure techniques
integrated system
polysulfone membranes
Opis:
Z uwagi na złożony i zmienny skład ścieków koksowniczych strategia ich oczyszczania jest trudna do uogólnienia i wymaga prowadzenia tego procesu w układach zintegrowanych, kojarzących biologiczne i fizykochemiczne procesy jednostkowe. W artykule omówiono badania, których celem było określenie efektywności oczyszczania ścieków koksowniczych w układzie łączącym ciśnieniowe techniki membranowe, ultrafiltrację i odwróconą osmozę. W procesie niskociśnieniowej filtracji zastosowano wytwarzane w laboratorium płaskie membrany polisulfonowe różniące się zwartością struktury i porowatością.
The applied more and more often in wastewater treatment technology integrated membranes system are the most often preliminary system purification and final purification. The applied in investigations process of ultarfiltration had for removal from purified coke making wastewater high-molecular organic compounds during when process of reverse osmosis had to provided removing the rest of low-molecular organic compounds and mineral substances. It was showed that direct carrying away cleaned sewages into the natural environment was impossible from the attention to higher, compared with standardized, concentration of ammonia on the level 22.4 mg + NH+4 /dm 3. The applied purification wastewater should be cleaned by ammonia stripping. From prepared ultrafiltration polysulfone membranes the most profitable showed membrane with the polymer content of 16% in solution.
Źródło:
Proceedings of ECOpole; 2009, 3, 1; 185-190
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coking plant wastewater treatment in integrated systems combining volume coagulation and advanced oxidation with pressure membrane techniques
Oczyszczanie poprocesowych wód koksowniczych w układach zintegrowanych łaczących metody koagulacji objetościowej i pogłębionego utleniania z ciśnieniowymi technikami membranowymi
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/395880.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
ścieki koksownicze
koagulacja objętościowa
odczynnik Fentona
ciśnieniowe techniki membranowe
ultrafiltracja
coke plant wastewater
volumetric coagulation
Fenton's reagent
pressure membrane techniques
ultrafiltration
Opis:
The article compares the efficiencies of coke plant wastewater treatment in the integrated systems that combine physicochemical and chemical purification methods with ultrafiltration and reverse osmosis. The wastewater treated came from the "Coke Plant Czestochowa New". In the process of volume coagulation the coagulant used was sulfate (VI) iron (III)-PIX-113, with the dosage of 400 mg/dm3 and pH was 9. In the advanced oxidation Fenton's reagent was applied, with the concentration of iron equal to 0.8g/dm3 and hydrogen peroxide 2.4 g/dm3. Coke plant wastewater treatment after its initial purification was performed by means of ultrafiltration process with the use of a polysulfone membrane with 16% weight content of polysulfones in the film-forming solution and a 5-second time of solvent evaporation from the membrane surface. In spite of the fact that treated coke oven wastewater presented high values of pollution indicators, making it impossible to drain into the natural receiver or sewer, it was posttreated in the process of reverse osmosis using a nylon membrane (ADF), of an American company Osmonics. The article also presents an attempt of modelling of low-pressure membrane filtration efficiency based on the relaxation model assumptions.
W artykule porównano efektywności oczyszczania ścieków koksowniczych pochodzących z zakładu koksowniczego "Koksownia Częstochowa Nowa" w układach zintegrowanych, które łączyły ze sobą fizykochemiczną oraz chemiczną metodę oczyszczania z ultrafiltracją i odwróconą osmozą. Proces koagulacji objętościowej prowadzono siarczanem (VI) żelaza (III)-PIX-113, którego dawka wynosiła 400 mg/dm3 a pH środowiska wynosiło 9 natomiast pogłębionego utleniania z wykorzystaniem odczynnika Fentona, stosując stężenie żelaza równe 0,8 g/dm3 i nadtlenku wodoru 2,4 g/dm3. Oczyszczanie poprocesowych wód koksowniczych po ich wstępnym oczyszczeniu prowadzono stosując proces ultrafiltracji z wykorzystaniem płaskiej polisulfonowej membrany o 16% wag. zawartości polisulfony w roztworze błonotwórczym i 5-cio sekundowym czasem odparowaniem rozpuszczalnika z powierzchni membrany. Ponieważ tak oczyszczone ścieki koksownicze nadal charakteryzowały się wysokimi wartościami wskaźników zanieczyszczeń, co uniemożliwiło odprowadzenie ich do odbiornika naturalnego lub kanalizacji doczyszczono, je w procesie odwróconej osmozy z zastosowaniem poliamidowej membrany (ADF) amerykańskiej firmy Osmonics. W pracy zaprezentowano również próbę modelowania wydajności procesu niskociśnieniowej filtracji membranowej w oparciu o założenia modelu relaksacyjnego.
Źródło:
Civil and Environmental Engineering Reports; 2011, 7; 83-98
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zmiany stężenia osadu granulowanego na efektywność beztlenowego oczyszczania ścieków generowanych w przemyśle mięsnym
The influence of granual sludge concentration changes for effectivines of anaerobic treatment of meat industry wastewater
Autorzy:
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Mielczarek, K.
Powiązania:
https://bibliotekanauki.pl/articles/400284.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki z zakładów mięsnych reaktora
ASBR
fermentacja metanowa
biogaz
wastewater from meat processing
plants
ASBR reactor
methane fermentation
biogas
Opis:
Przemysł mięsny jest gałęzią sektora spożywczego, który zużywa duże ilości wody w konsekwencji produkuje również znaczne ilości ścieków charakteryzujących się dużą zawartością składników organicznych i wysokim stężeniem zawiesin oraz substancji biogennych. W badaniach podjęto próbę określenie wpływu stężenia granulowanego osadu beztlenowego na efektywność oczyszczania ścieków z zakładu mięsnego w reaktorze typu ASBR. Beztlenowe oczyszczanie ścieków z zakładu mięsnego realizowano w reaktorze ASBR przy wyznaczonym najkorzystniejszym stężeniu osadu (20 g/dm3) pozwoliło na wysokie usunięcie zanieczyszczeń organicznych oznaczanych jako ChZT (73%), BZT5 (71%) i OWO (76%).
The meat industry is a branch of the food sector, which consume large amounts of water consequently, also produces of wastewater are characterized by a high organic content and high con-centration of suspended solids, inorganic salts and nutrients. The study attempted to determine the effect of granular sludge concentration on the efficiency of anaerobic treatment of wastewater from meat processing plants in the ASBR reactor. Anaerobic treatment of wastewater generated in the meat processing plants carried out by designated most preferred concentration of sludge (20 g/dm 3) in the ASBR reactor allows for high removal of organic pollutants determined as COD (73%), BOD (71%) and TOC (76%).
Źródło:
Inżynieria Ekologiczna; 2011, 24; 89-98
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie wydajności procesu ultrafiltracyjnego oczyszczania ścieków koksowniczych z zastosowaniem membran komercyjnych
Modeling of ultrafiltration process efficiency in treatment coke plant wastewater with use industrial membranes
Autorzy:
Mielczarek, K.
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Korus, I.
Powiązania:
https://bibliotekanauki.pl/articles/127380.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ultrafiltracja
ścieki koksownicze
ciśnieniowe techniki membranowe
modelowanie wydajności procesu ultrafiltracji
ultrafiltration
coke plant wastewater
high pressure membrane techniques
commercial membranes
Opis:
Przedstawiono efektywność procesu oczyszczania poprocesowych wód koksowniczych w układzie zintegrowanym ultrafiltracja-odwrócona osmoza. W procesach ciśnieniowej filtracji membranowej zastosowano polimerowe membrany amerykańskiej firmy Osmonics. Wyznaczenie na drodze doświadczalnej ultrafiltracyjnych strumieni permeatów początkowego (J0) i równowagowego (nasycenia - J∞) oraz w sposób graficzny stałej czasowej t0 umożliwiło, zgodnie z założonym modelem relaksacyjnym, przeprowadzenie obliczeń pozwalających na prognozowanie wydajności stosowanych membran.
In the article there have been presented the results of research whose aim was to determine the effectiveness of treating the coke plant wastewater in the integrated ultrafiltration - reverse osmosis system. In the process pressure membrane filtration was carried out on using the polymer membranes of an American Osmonics brand. Determining ultrafiltration initial permeat fluxes (J0) and equilibrium (saturations - J∞) on the experimental road and into the graphic way of the temporary constant (t0) enabled based on the relaxation model established, that describes, define the possibility of predicting the polysulfone ultrafiltration membranes efficiency in the process of coke industry wastewater treatment.
Źródło:
Proceedings of ECOpole; 2009, 3, 2; 483-489
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of Ultrafiltration Process Efficiency in Coke Plant Wastewater Treatment with the Use of Industrial Membranes
Modelowanie wydajności procesu ultrafiltracyjnego oczyszczania ścieków koksowniczych z zastosowaniem membran komercyjnych
Autorzy:
Mielczarek, K.
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Korus, I.
Powiązania:
https://bibliotekanauki.pl/articles/387903.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ultrafiltracja
ścieki koksownicze
ciśnieniowe techniki membranowe
membrany komercyjne
ultrafiltration
coke plant wastewater
high pressure membrane techniques
commercial membranes
Opis:
In the research conducted there was determined the coke plant waste treatment efficiency in the integrated process that combines ultrafiltration with the reverse osmosis system. In both pressure filtration methods commercial Osmonics membranes were applied. The degree of removal efficiency was evaluated according to changes in the values of selected pollution indicators that characterized “raw” and cleaned wastewater. On the basis of the relaxation method assumptions there was made an attempt to predict the efficiency of the membranes used at the initial stage of ultrafiltration process carried out in non-stationary arrangement. The values of the initial permeate flux and saturation flux, experimentally determined, as well as time constants, determined graphically, allowed to calculate theoretical temporary permeate flux for selected low pressure membranes.
W przeprowadzonych badaniach określono efektywność oczyszczania ścieków koksowniczych w układzie zintegrowanym łączącym ultrafiltrację z procesem odwróconej osmozy. W obu procesach filtracji ciśnieniowej stosowano membrany komercyjne amerykańskiej firmy Osmonics. Stopień oczyszczenia ścieków oceniano na podstawie zmiany wartości wskaźników zanieczyszczeń, takich jak: stężenie węgla ogólnego oraz organicznego, cyjanków, fenoli, ChZT oraz azotu amonowego charakteryzujących ścieki surowe i oczyszczone. Korzystając z modelu relaksacyjnego, podjęto próbę prognozowania wydajności membran stosowanych w procesie ultrafiltracji ścieków, prowadzonym w układzie niestacjonarnym. Doświadczalnie wyznaczone wartości strumieni początkowych permeatów, strumieni nasycenia oraz wyznaczone w sposób graficzny stałe czasowe umożliwiły obliczenie teoretycznych chwilowych strumieni permeatów dla wybranych membran niskociśnieniowych.
Źródło:
Ecological Chemistry and Engineering. A; 2012, 19, 4-5; 457-470
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of UASB reactor in meat industry wastewater treatment
Zastosowanie reaktora UASB do oczyszczania ścieków z zakładów mięsnych
Autorzy:
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Mielczarek, K.
Krzywicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/395840.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków z zakładów mięsnych
reaktor UASB
biogaz
meat industry wastewater
reactor UASB
hydraulic retention time
biogas
Opis:
The meat industry is a branch of the food sector, which significantly affects the degradation of the environment. Consuming large amounts of water consequently produces significant quantities of water which are characterised by a high organic content and high concentration of suspended solids, inorganic salts and nutrients. The study attempted to determine the influence of the HRT and OLR on biogas production and the treatment of wastewater from the meat industry, and it was found that the most preferred treatment process carried out was at HRT 3d (OLR-0.55 kgCOD/m3d). The anaerobic process under HRT 3d obtained a considerable degree of the removal of organic pollutants from raw wastewater designated as COD (79%), BOD (77%) and TOC (73%). The concentrations of COD and BOD were 350 mg/dm3 and 363 mg/dm3 respectively. The value of TOC reached a level of 142 mg/dm3. Due to its poor quality, effluent from a UASB reactor cannot be discharged into natural water without additional treatment processes. The addition of reverse osmosis in the meat industry wastewater treatment is suggested.
W badaniach podjęto próbę określenie wpływu czasu zatrzymania ścieków z zakładu mięsnego w reaktorze UASB na efektywność ich oczyszczania oraz na wielkość dobowej produkcji biogazu. HRT zmieniano w zakresie od 2 do 6 dób co wiązało się ze zmianą obciążenia komory ładunkiem zanieczyszczeń z 0,27 kgChZT/m3d do 0,82 kgChZT/m3d. Stwierdzono, że wraz ze skracaniem czasu zatrzymania z 6d do 2d, jakość ścieków ulega pogorszeniu, ale ilość produkowanego biogazu zwiększała się. Zaobserwowano, że wielkość współczynnika biogazu ulegała obniżeniu. Stwierdzono, że najkorzystniej prowadzić proces oczyszczania badanych ścieków przy HRT równym 3 doby z uwagi na dobre efekty oczyszczania i wysoki współczynnik produkcji biogazu wynoszący 0,45 dm3 biogazu/gChZT_us. Prowadzenie procesu fermentacji przy tak ustalonych warunkach pozwoliło na wysoki stopień usunięcia zanieczyszczeń oznaczanych, jako ChZT (79%), BZT5 (77%) i OWO (73%). Stężenie ChZT ścieków oczyszczonych wynosiło 350 mg/dm3, BZT5 463mg/dm3 a OWO 142 mg/dm3. Pomimo wysokiego stopnia usunięcia zanieczyszczeń z badanych ścieków nie ma jednak możliwości odprowadzenia ich do odbiornika naturalnego. Proponuje się, aby w kolejnych etapach badań podjąć próbę doczyszczania ścieków w procesie odwróconej osmozy co w przyszłości może pozwolić na zamknięcie obiegu wody na terenie zakładu.
Źródło:
Civil and Environmental Engineering Reports; 2011, 7; 119-128
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of meat industry wastewater using coagulation and Fentons reagent
Oczyszczanie ścieków zakładów mięsnych w procesie koagulacji i z zastosowaniem odczynnika Fentona
Autorzy:
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Mielczarek, K.
Krzywicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/395853.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
koagulacja
odczynnik Fentona
zakłady mięsne
meat industry wastewater
coagulation process
Fenton process
PIX 113
PAX XL 19
Opis:
The aim of the paper was to study meat industry wastewater treatment efficiency during chemical processes. The research was carried out in two steps. The first step was the coagulation process and the second step was the Fenton reaction. It was found that wastewater treatment with the use of Fenton's reagent achieved a higher degree of removal of the pollutants determined as COD, TOC and TN in comparison to the coagulation of PIX 113. The most profitable dose of the Fenton's reagent was 0.6/1.8 Fe2+/H2O2 g/dm3. The degree of COD removal from the wastewater with the use of the Fenton's reagent was higher by 10% on average compared to PIX 113. TOC and TN removal efficiency, using the Fenton's reagent was higher by 13% and 40.5% respectively when compared to the coagulation process. The aim of the paper was to study meat industry wastewater treatment efficiency during chemical processes. The research was carried out in two steps. The first step was the coagulation process and the second step was the Fenton reaction. It was found that wastewater treatment with the use of Fenton's reagent achieved a higher degree of removal of the pollutants determined as COD, TOC and TN in comparison to the coagulation of PIX 113. The most profitable dose of the Fenton's reagent was 0.6/1.8 Fe2+/H2O2 g/dm3. The degree of COD removal from the wastewater with the use of the Fenton's reagent was higher by 10% on average compared to PIX 113. TOC and TN removal efficiency, using the Fenton's reagent was higher by 13% and 40.5% respectively when compared to the coagulation process.
W badaniach porównano efektywności oczyszczania ścieków powstających podczas uboju i przetwórstwa mięsa w procesie koagulacji oraz w procesie utleniania z zastosowaniem odczynnika Fentona. W procesie koagulacji wykorzystano dwa rodzaje koagulantów (PIX 113 i PAX XL 19). Stwierdzono, że stopień usunięcia ChZT przy użyciu PIX 113 był średnio o 9% wyższy w porównaniu do PAX XL 19. Stosując wyznaczoną jako najkorzystniejszą dawkę PIX 113 wynoszącą 0,6 g/dm3 ścieki po procesie koagulacji charakteryzowały się wartością ChZT, OWO i CA odpowiednio na poziomie 836 mg/dm3, 363 mg/dm3 i 359 mg/dm3. Porównując efektywność usunięcia zanieczyszczeń z oczyszczanych ścieków stwierdzono, że korzystniej prowadzić chemiczny proces ich oczyszczania z zastosowanie odczynnika Fentona. Jako najkorzystniejszą dawkę odczynnika Fentona wyznaczono 0,6/1,8 Fe2+/H2O2 g/dm3. Wartość ChZT ścieków oczyszczonych na drodze koagulacji oraz z zastosowaniem odczynnika Fentona wynosiła odpowiednio 515 mg/dm3 i 834 mg/dm3. Stopień usunięcia OWO ze ścieków z zastosowaniem odczynnika Fentona był średnio o 13% wyższy w porównaniu do procesu koagulacji. Stężenie OWO ścieków oczyszczonych w przypadku reakcji Fentona było na poziomie 241,4 mg/dm3 a po procesie koagulacji 363 mg/dm3. Przeprowadzone badania pokazały również, że pomimo wysokiego stopnia usunięcia zanieczyszczeń ścieki oczyszczone w obu procesach chemicznych nie mogą być odprowadzone do odbiornika naturalnego. Po obu procesach wartość ChZT ścieków oczyszczonych była prawie 7-krotnie (proces koagulacji) i 4- krotnie (reakcja Fentona) przekroczona w stosunku do dopuszczalnych wartości. Wartość OWO po procesie koagulacji i Fentona została przekroczona odpowiednio 12 i 8-krotnie. Prawie 5-krotnie (odczynnik Fentona) i 12-krotnie (proces koagulacji) w ściekach oczyszczonych została przekroczona wartość azotu całkowitego. Z uwagi na to sugeruje się łączenie tych procesów z innym procesami jednostkowymi np. procesem biologicznym lub ciśnieniowymi technikami membranowymi.
Źródło:
Civil and Environmental Engineering Reports; 2011, 6; 45-58
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies