Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kurashima, M." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Photoinduced Phase Transition in $Pr_{0.5}Ca_{0.5}CoO_3$ Studied by Sequential Pulse Excitations
Autorzy:
Seko, K.
Okimoto, Y.
Kurashima, M.
Fukaya, R.
Egawa, T.
Ishikawa, T.
Onda, K.
Koshihara, S.
Kyomen, T.
Itoh, M.
Powiązania:
https://bibliotekanauki.pl/articles/1490006.pdf
Data publikacji:
2012-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
78.66.-w
78.47.jg
Opis:
A perovskite-type cobalt oxide, $Pr_{0.5}Ca_{0.5}CoO_3$ (PCCO), shows photoinduced phase transition. In this study, we successively irradiated two laser pulses with different intensities to PCCO and probed the transient change of the reflection at 2.0 eV. Assuming propagation of the two different photoinduced metallic states, we could reproduce the time profiles as well as the magnitude in the reflectance change, indicating the fabrication of the photoinduced multilayered thin film in $Pr_{0.5}Ca_{0.5}CoO_3$.
Źródło:
Acta Physica Polonica A; 2012, 121, 2; 369-371
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of a magnetic field monitoring system for the JAERI AVF cyclotron
Autorzy:
Okumura, S.
Arakawa, K.
Fukuda, M.
Nakamura, Y.
Yokota, W.
Ishimoto, T.
Kurashima, S.
Ishibori, I.
Nara, T.
Agematsu, T.
Nakajima, T.
Powiązania:
https://bibliotekanauki.pl/articles/148733.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
compensation coil
cyclotron
magnetic field
Opis:
We have developed a probe of a nuclear magnetic resonance (NMR) magnetometer for measurement of a fluctuation of an AVF cyclotron field. The stability of the magnetic field of the JAERI AVF cyclotron, measured with the NMR probe, was within 1 × 10-5. A field-measurement accuracy of the order of 1 × 10-6 was achieved using a set of field-compensation coils and optimizing the probe position to obtain enough homogeneity of the magnetic field around the probe for measuring the cyclotron field with a high gradient. To eliminate a major bottleneck in the field measurement inside the cyclotron, the probe was specially produced with the cable shielding against RF noises and proper materials applied.
Źródło:
Nukleonika; 2003, 48,suppl.2; 35-37
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies