Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kulig, P." wg kryterium: Autor


Wyświetlanie 1-8 z 8
Tytuł:
Fungal contamination of ward furnishings and medical equipment used in the treatment and nursing of newborns
Autorzy:
Gniadek, A.
Białecka, A.
Opach, I.
Kulig, A.
Krzyściak, P.
Ostrogórska, P.
Macura, A.B.
Powiązania:
https://bibliotekanauki.pl/articles/2085935.pdf
Data publikacji:
2020
Wydawca:
Instytut Medycyny Wsi
Tematy:
airborne microorganisms
fungal
medical equipment
Opis:
Introduction and objective. Newborn babies staying on hospital wards are likely to be colonized by microorganisms, including potentially pathogenic fungi. The aim of the study was to assess the mycological purity of hospital wards and medical equipment utilized in the treatment and nursing of newborns. Materials and method. The study was conducted in Neonatal High Dependency Units (NHDU) and Neonatal Intensive Care Units (NICU). 539 samples were collected from 24 different sources, 130 from ward furnishings and 289 from medical equipment. The study was carried out following the microbiology research methods for sample collection. Subsequently, the samples (swabs, water from incubators, washings from respirator tubes and nasal cannulas (nCPAP)) were cultivated on Sabouraud agar plates. The stamps were collected with the application of Count-Tact method. The samples were incubated at the temperature of 25+/-2oC and the number of fungi assessed (cfu/cm-2 of the surface area). The species were identified based on their morphological and biochemical features. Results. Fungal growth was observed on 60% of samples collected from ward furnishings and 7% of samples collected from medical equipment. The average number of cfu/cm-2 ranged between 0–8.84 in the case of ward furnishings and between 0–1.22 cfu/cm-2 in the case of medical equipment. In 180 samples collected from the material which had direct contact with newborns no fungal growth was observed. Conclusions. The furnishings of the wards on which newborns were treated and nursed were contaminated with fungi to an extent which did not pose a threat to the life and health of the newborns. Medical equipment (respirators, incubators, nCPAP cannulas and masks) which came into direct contact with newborns was free from fungi.
Źródło:
Annals of Agricultural and Environmental Medicine; 2020, 27, 3; 348-355
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Specyfika pracy psów służbowych w aspekcie doboru do policji
The specific work aspects of dogs selected to the service in police
Autorzy:
Kulig, S.
Gryzinska, M.
Listos, P.
Powiązania:
https://bibliotekanauki.pl/articles/857964.pdf
Data publikacji:
2018
Wydawca:
Krajowa Izba Lekarsko-Weterynaryjna
Tematy:
psy
uzytkowanie zwierzat
wech
detekcja wechowa
psy sluzbowe
specyfika pracy
psy wojskowe
psy policyjne
psy wykrywajace materialy wybuchowe
psy wykrywajace narkotyki
psy wspomagajace osoby niepelnosprawne
dobor zwierzat
dobor ras
szkolenie
wymagania zdrowotne
Źródło:
Życie Weterynaryjne; 2018, 93, 05
0137-6810
Pojawia się w:
Życie Weterynaryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of polymorphism within exon 12 of IGF1R gene on meat production traits in Limousin and Hereford cattle
Udział polmorfizmu w eksonie 12 genu IGF1R w kształtowaniu cech mięsności bydła ras hereford i limousine
Autorzy:
Szewczuk, M.
Sablik, P.
Kulig, H.
Powiązania:
https://bibliotekanauki.pl/articles/45273.pdf
Data publikacji:
2017
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Źródło:
Acta Scientiarum Polonorum. Zootechnica; 2017, 16, 4
1644-0714
Pojawia się w:
Acta Scientiarum Polonorum. Zootechnica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warunki transportu i kondycja tuczników z dostaw bezpośrednich do zakładów ubojowych na Podkarpaciu
Transport conditions and the state of fatteners from direct supplies to slaughter houses in the Subcarpathian region
Autorzy:
Tereszkiewicz, K.
Molenda, P.
Choroszy, K.
Kulig, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/315299.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
logistyka
transport zwierząt
pojazdy ciężarowe
logistics
animals transport
trucs
Opis:
W pracy przedstawiono wyniki badań dotyczących warunków transportu i kondycji tuczników transportowanych bezpośrednio z miejsca produkcji do uboju. Badania przeprowadzono w trzech zakładach ubojowych zlokalizowanych w województwie podkarpackim. Przeprowadzone badania wykazały, że do przewozu zwierząt na krótkich dystansach najczęściej były wykorzystywane agregaty rolnicze. Tuczniki z większych odległości były dostarczane specjalistycznymi jedno i wielopokładowymi pojazdami ciężarowymi. Do załadunku zwierząt wykorzystywano głównie rampy. Tuczniki były przewożone na podłożu wyścielonym ściółką jednak w znacznej części w obsadzie niezgodnej z obowiązującymi normami. Badania wykazały, że około 57% zwierząt miało obrażenia ciała w postaci ran i siniaków. Obrażenia częściej występowały u zwierząt transportowanych na długich dystansach.
The study presents results of research into the conditions of transport and the state of fatteners transported from the place of production directly to slaughter. The research was conducted in three slaughter houses located in the Subcarpathian voivodeship. The study showed that agricultural units were used to transport the animals at short distances. At longer distances fatteners were transported with special single or multi-storey vehicles. Ramps were used to load the animals. Fatteners were transported on a bedded floor, with stocking density compliant with the current norms. The study showed that about 57% of the animals had body injuries comprising wounds and bruises. Injuries occurred more frequently in animals transported at long distances.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 6; 1574-1578, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
From Light to Heavy Nuclear Systems, Production and Decay of Fragments Studied with Powerful Arrays
Autorzy:
Casini, G.
Morelli, L.
Barlini, S.
Piantelli, S.
D'Agostino, M.
Baiocco, G.
Marchi, T.
Abbondanno, U.
Ademard, G.
Appannababu, S.
Bini, M.
Bonnet, E.
Borderie, B.
Bougault, R.
Bruno, M.
Chbihi, A.
Cinausero, M.
Degerlier, M.
Fabris, D.
Frankland, J.
Gelli, N.
Gramegna, F.
Gruyer, D.
Gulminelli, F.
Kordyasz, A.
Kozik, T.
Kravchuk, V.
Kulig, P.
Le Neindre, N.
Lopez, O.
Maurenzig, P.
Olmi, A.
Pasquali, G.
Pârlog, M.
Poggi, G.
Rivet, M.
Rosato, E.
Sosin, Z.
Spadaccini, G.
Stefanini, A.
Twarog, T.
Valdrè, S.
Vient, E.
Raduta, A.
Powiązania:
https://bibliotekanauki.pl/articles/1402639.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
25.70.Gh
25.70.Pq
25.70.Mn
29.40.-n
Opis:
Reactions between heavy-ions at various energy regimes produce many nuclear fragments which can be populated in highly excited states. The study of these fragments, detected at the end of their particle decay, is important to investigate nuclear forces and structure effects. In recent years there have been many efforts to extend these studies towards the drip-lines, i.e. to systems far from the β-stability valley, by using accelerated radioactive beams. The development of such infrastructures is accompanied by the development of more powerful detectors and associated electronics, capable to identify ions with very different sizes and kinetic energies. Here we give two examples which show how advanced arrays can contribute to the studies on nuclear phenomena. The examples come from the European FAZIA collaboration and from recent campaigns with the GARFIELD apparatus, the latter in operation at the INFN Legnaro Laboratory (Italy) where the SPES RIB facility is under construction.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1548-1551
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Genetic Algorithm Embedded into a Quality-Oriented Workflow of Methods for the Development of a Linear Drive used in Intralogistic Systems
Autorzy:
Wörner, L.
Kulig, S.
Willing, M.
Winzer, P.
Powiązania:
https://bibliotekanauki.pl/articles/140602.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DeCoDe
genetic algorithm
intralogistic systems
linear induction machine
system model
Opis:
This paper presents the results of the DFG-project (Deutsche Forschungsgemeinschaft) Q-ELF (“Qualitätsorientierter Methodenworkflow für die Produktneuentwicklung eines Linearantriebs in der Fördertechnik”) carried out in cooperation of the TU Dortmund University (support code KU 1307/12-1) with the BUW Wuppertal (support code WI 1234-11/1). The project continues the former project SFB 696 (Sonderforschungsbereich) regarding the Demand Compliant Design (DeCoDe) and the corresponding system model that strengthens the knowledge management to create high-quality mechatronical systems. In contrast to the SFB, which comprised the reverse engineering of a belt conveyor, Q-ELF applied a workflow of methods for quality oriented development on a new product. The DeCoDe ensures a methodical development that connects different engineering domains. This connection is important because the most problems and malfunctions arise at the interface of different domains due to their different notations for example. This approach also enables a methodical comparison of different competing concepts to pick the best suited one. A genetic algorithm is presented to further decrease the design-space. The project was carried out to develop linear drives for intralogistic systems.
Źródło:
Archives of Electrical Engineering; 2014, 63, 4; 647-665
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Morphological changes in pulmonary parenchyma following ventilation with 20% heliox at an overpressure of 0.5 MPa
Zmiany morfologiczne w miąższu płucnym po wentylacji helioksem 20% przy nadciśnieniu 0,5 MPa
Autorzy:
Siermontowski, P.
Pleskacz, K.
Pedrycz, A.
Olszański, R.
Kulig, M.
Powiązania:
https://bibliotekanauki.pl/articles/366473.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
lung morphology
heliox
rat
hyperbaric oxygenation
morfologia płuc
helioks
szczur
hiperbaria
Opis:
Breathing mixes, used both in normobaria in medicine as well as in hyperbaric oxygenation in the course of diving, affect the morphological image of pulmonary parenchyma. The changes are commonly associated with the impact of hyperbaric oxygen. The objective of the study was to determine the impact of factors other than hyperbaric oxygenation in hyperbaric exposure with the use of heliox. The study was performed on rats subjected to hyperbaric oxygenation at an overpressure of 0.5MPa with heliox possessing a 20% oxygen content. The control group consisted of rats subjected to the same air exposures. The exposure times were 1, 2 and 4 hours. After the experiment the animals were put to death and microscopic specimens were produced from their lungs, followed by quantitative examination. Only slight deviations from regular pulmonary histology were observed after a one-hour exposure in both groups. Exposure extension to 2 hours resulted in an increased aeration of lungs in the control group and in parenchymal oedema, as well as an occurrence of intra-alveolar oedema in the group breathing with heliox. These changes were not significantly intensified through an exposure extended to 4 hours with the exception of a growing pulmonary oedema.
Stosowane zarówno w normobarii w medycynie, jak i w hiperbarii w nurkowaniu mieszaniny oddechowe wpływają na obraz morfologiczny miąższu płucnego. Zmiany przypisywane są na ogół działaniu tlenu hiperbarycznego. Celem badań było określenie wpływu innych czynników niż hiperbaria tlenowa podczas ekspozycji hiperbarycznej z zastosowaniem helioksu. Badanie wykonano na szczurach, które poddawano działaniu hiperbarii w nadciśnieniu 0,5MPa z helioksem zawierającym 20% tlenu. Grupę kontrolną stanowiły szczury poddane takim samym ekspozycjom powietrznym. Czas ekspozycji 1, 2 i 4 godziny. Szczury po doświadczeniu uśmiercono, wykonano preparaty mikroskopowe z płuc, które poddano badaniom ilościowym. Stwierdzono niewielkie jedynie odchylenia od prawidłowej histologii płuca po jednogodzinnej ekspozycji w obu grupach. Przedłużenie ekspozycji do 2 godzin spowodowało zwiększenie powietrzności płuc w grupie kontrolnej i obrzęk śródmiąższowy, a także pojawienie się obrzęku śródpęcherzykowego w grupie oddychającej helioksem. Zmiany te nie wzrosły znamiennie po przedłużeniu ekspozycji do 4 godzin, za wyjątkiem narastania obrzęku płuc.
Źródło:
Polish Hyperbaric Research; 2013, 4(45); 37-52
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Morphometric study on the lesions in the trachea wall in rats in hyperbaric oxygen therapy
Badania morfometryczne zmian w ścianie oskrzeli u szczurów w hiperbarii tlenowej
Autorzy:
Siermontowski, P.
Konarski, M.
Pedrycz, A.
Wojtowicz, T
Ostapowicz van Damme, K.
Kulig, M.
Powiązania:
https://bibliotekanauki.pl/articles/366428.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
oxygen
hyperbaria
morphometrics
trachea
tlen
hiperbaria
morfometria
tchawica
Opis:
Clinical observations and experimental research results prove the toxic effect of oxygen on the respiratory tract both in normo- and hyperbaria. The majority of available studies concern changes in the lung parenchyma, only some of them refer to the impact of hyperbaric oxygen on the respiratory tract. The objective of the study based on an animal model was to provide an evaluation of the effect of overpressure of exhaled oxygen (oxygen hyperbaria) and the time of its duration on morphological changes in the mucous and submucous membranes of the trachea. Oxygen hyperbaria corresponding to the depth of 5 – 7 metres induces temporary motor agitation and increased aggression in rats lasting from 3 to 20 minutes. Further rises of oxygen pressure cause a reduction of the agitation, whereas at the depth of 40 m it results in extreme weakening of the breathing activity and leads to the animals’ death.Growing oxygen hyperbaria causes thickening of both the mucous and submucous membranes of the rats’ trachea accompanied by narrowing of its lumen. The changes are intensified with prolonged duration of hyperbaric oxygen therapy. The most serious morphological changes were observed in the submucous membrane of the trachea. The dominant lesion consisted of an interstitial oedema with the widening of the vascular bed. Progressing hyperbaria caused thickening of the mucous and submucous membranes with a simultaneous reduction of the trachea lumen. Similar tendencies persisted with prolonged duration of hyperbaria.
Obserwacje kliniczne oraz wyniki badań doświadczalnych dowodzą toksycznego działania tlenu na drogi oddechowe zarówno w normo - jak i hiperbarii. Większość dotychczasowych opracowań dotyczy zmian w miąższu płucnym, tylko pojedyncze odnoszą się do wpływu hiperbarii tlenowej na drogi oddechowe. Celem badań własnych na modelu zwierzęcym, była ocena wpływu nadciśnienia tlenu wdychanego (hiperbarii tlenowej) i czasu stosowania tego nadciśnienia na zmiany morfologiczne w błonie śluzowej i włóknistej tchawicy. Hiperbaria tlenowa odpowiadająca głębokości do 5 - 7 metrów wywołuje u szczurów przejściowe, trwające od 3 do 20 minut pobudzenie ruchowe i zwiększenie agresywności. Dalsze zwiększanie ciśnienia tlenu powoduje zmniejszenie ich ruchliwości, a na głębokości do 40 m doprowadza do ekstremalnego osłabienia oddychania i padania zwierząt. Narastanie hiperbarii tlenowej powoduje u szczurów pogrubienie zarówno błony śluzowej jak i włóknistej tchawicy, przy równoczesnym zwężeniu jej światła. Zmiany te narastają wraz z wydłużaniem czasu działania hiperbarii tlenowej. Wśród tych zmian dominował obrzęk śródmiąższowy z poszerzeniem łożyska naczyniowego. W miarę narastania hiperbarii obserwowano pogrubienie błony śluzowej i włóknistej, przy równoczesnym zmniejszaniu się światła tchawicy. Podobne tendencje utrzymywały się wraz z narastaniem czasu działania hiperbarii.
Źródło:
Polish Hyperbaric Research; 2013, 2(43); 7-22
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies