Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kozak, Michał" wg kryterium: Autor


Wyświetlanie 1-8 z 8
Tytuł:
Determinants of Business Survivability: Literature Review
Autorzy:
Kozak, Michał
Powiązania:
https://bibliotekanauki.pl/articles/633715.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Marii Curie-Skłodowskiej. Wydawnictwo Uniwersytetu Marii Curie-Skłodowskiej
Tematy:
business survival, critical success factors, collapse of enterprises, micro business, small business
Opis:
Purpose – The goal of this article was to define the concept of business survivability on the basis of a review of subject literature, as well as to identify the main determinants influencing the survivability of micro and small businesses based on an analysis of empirical studies that most often included a five-year observation of an enterprise – from the moment of its establishment, until it was deregistered, or the observation period was over.Design/Methodology/Approach – The author utilises a review of Polish and foreign subject literature, as well as secondary research regarding the survivability of micro and small businesses in the 20th and 21st centuries.Findings – The results suggest significant differences in business survivability depending on the country of origin of a given enterprise. The factors determining business survivability were divided into micro and macroeconomic, and their presence is vital for the company to persevere in turbulent market conditions.Originality/Value – This article is a compilation of definitions of business survivability across foreign and Polish studies of micro and small businesses after 2000. The paper compares the results of business survivability in Poland and western countries.
Źródło:
International Journal of Synergy and Research; 2017, 6
2083-0025
Pojawia się w:
International Journal of Synergy and Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the dynamics for a mechanics with noncontinuous hamiltonians
Autorzy:
Kondracki, Witold
Kozak, Michał
Powiązania:
https://bibliotekanauki.pl/articles/748334.pdf
Data publikacji:
1986
Wydawca:
Polskie Towarzystwo Matematyczne
Tematy:
Hamilton's equations
Opis:
.
Mechanical systems with noncontinuous or numerical [11] hamiltonian are considered. The method of defining a dynamics for such mechanical systems is given.
Źródło:
Mathematica Applicanda; 1986, 14, 27
1730-2668
2299-4009
Pojawia się w:
Mathematica Applicanda
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The density theorem for the actions of I.L.H.-Lie groups
Autorzy:
Kondracki, Witold
Kozak, Michał
Powiązania:
https://bibliotekanauki.pl/articles/748519.pdf
Data publikacji:
1991
Wydawca:
Polskie Towarzystwo Matematyczne
Tematy:
Group structures and generalizations on infinite-dimensional manifolds
Groups acting on specific manifolds
Opis:
.
The density theorem for the action of I.L.H.-Lie group G on the I.L.H.-manifold M is proved i.e. it was shown that the stratum with trivial isotropy group is open and dense subset of M.
Źródło:
Mathematica Applicanda; 1991, 19, 33
1730-2668
2299-4009
Pojawia się w:
Mathematica Applicanda
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury na pracę nadprzewodnikowego ogranicznika prądu dla sieci średnich napięć
Influence of Temperature on the Operation of the Superconducting Fault Current Limiter for Medium Voltage Networks
Autorzy:
Kozak, Sławomir
Majka, Michał
Kozak, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/159774.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
nadprzewodnikowy ogranicznik prądu
SFCL
wysokotemperaturowa taśma nadprzewodnikowa II generacji
HTS
superconducting fault current limiter
2nd generation high temperature superconductor tape
Opis:
Nadprzewodnikowy ogranicznik prądu dla sieci średniego napięcia chłodzony z wykorzystaniem kriochłodziarki, sfinansowany przez NFOŚiGW oraz NCBiR, w ramach projektu: GEKON2/O2/267193/13/2015, testowany był Instytucie Elektrotechniki. Do budowy tego ogranicznika wykorzystana została wysokotemperaturowa taśma nadprzewodnikowa II generacji – SF12100. W tym ograniczniku istnieje możliwość zmiany roboczej temperatury pracy. Przeanalizowana została praca ogranicznika w trzech temperaturach: 72 K, 80 K i 86 K, w których dokonane zostały eksperymentalne próby zwarciowe oraz niższych temperaturach: 38 K, 51 K, 66 K i w temperaturze ciekłego azotu: 77,4 K. Można zwiększyć wielokrotnie prąd roboczy poprzez obniżenie temperatury pracy ogranicznika. Dla temperatur początkowych powyżej 51 K maksymalna temperatura taśmy nadprzewodnikowej w chwili wyłączenia prądu zwarciowego przez zewnętrzny wyłącznik (t = 0,08 s) nie przekracza 290 K. Dla temperatur powyżej 51 K w przypadku badanego ogranicznika można rozważać zwiększenie czasu ograniczania prądu. Wydłużenie czasu pracy ogranicznika zwiększy maksymalną temperaturę taśmy nadprzewodnikowej i wydłuży czas schładzania ogranicznika po ograniczeniu zwarcia.
The superconducting fault current limiter (SFCL) for medium voltage networks cooled using a cryocooler was financed by NFOŚiGW and NCBiR, under the project: GEKON2 / O2 / 267193/13/2015, and was tested in the Electrotechnical Institute. The 2nd generation high temperature superconductor (HTS) tape – SF12100 was used to build this SFCL. In this limiter it is possible to change the operating temperature. The limiter operation was analyzed at three temperatures: 72 K, 80 K and 86 K, in which the experimental short-circuit tests were made and at lower temperatures: 38 K, 51 K, 66 K, and at liquid nitrogen temperature: 77,4 K. The operating current can be increased many times by lowering the limiter's operating temperature. For initial temperatures above 51 K, the maximum temperature of the superconducting tapes when the short-circuit current is switched off by an external switch (t = 0,08 s) does not exceed 290 K. For temperatures above 51 K, the current limitation time can be increased. Extending the limiter's operating time will increase the maximum HTS tape temperature and extend the limiter's cooling time after limiting the short-circuit.
Źródło:
Prace Instytutu Elektrotechniki; 2020, 281; 39-47
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methodology for testing the electric strength of vacuum chambers designed for modern medium voltage switchgear
Autorzy:
Węgierek, Paweł
Lech, Michał
Kozak, Czesław
Pastuszak, Justyna
Powiązania:
https://bibliotekanauki.pl/articles/1849145.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vacuum interrupter
vacuum breakdown
electric strength
vacuum switchgear
measurement uncertainty
Opis:
The article presents methodology for testing the electric strength of vacuum chambers designed for modern medium voltage switchgear developed by the authors, using two innovative test stands designed and constructed by the research team above. Verification of the correctness of operation of the test stands, as well as the validity of the developed methodology was carried out by performing a series of tests. It was determined that below certain pressure values in the tested chamber (from about 5:0 x 100 Pa for station 1 and for about 4:0 x 10-1 Pa for station 2), the electric strength maintains a constant value, which guarantees stable operation of the vacuum chamber. The values of the total measurement uncertainty for the electric strength tests were also estimated.
Źródło:
Metrology and Measurement Systems; 2020, 27, 4; 687-700
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surgeon’s viewpoint on lung transplantatio in cystic fibrosis patients – preliminary report
Punkt widzenia chirurga na przeszczepianie płuc u chorych z mukowiscydozą – doniesienie wstępne
Autorzy:
Kubisa, Bartosz
Piotrowska, Maria
Milczewska, Justyna
Bielewicz, Michał
Kochanowski, Leszek
Pieróg, Jarosław
Kozak, Anna
Czarnecka, Michalina
Wójcik, Norbert
Wasilewski, Piotr
Feledyk, Grzegorz
Kubisa, Anna
Brykczyński, Mirosław
Sielicki, Piotr
Grodzki, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1032984.pdf
Data publikacji:
2015
Wydawca:
Wydawnictwo ALUNA
Tematy:
cystic fibrosis
lung transplantation
qualification
respiratory insufficiency
Opis:
Introduction: The surgeon’s viewpoint on a patient with cystic fibrosis differs from that of a pediatrician or internist. The problems a cystic fibrosis specialist encounters are different from those faced by the surgeon who takes over the patient in a very advanced, often terminal stage of the disease. Hence, the main problem for the surgeon is the decision concerning the surgery (lung transplantation, pneumonectomy, lobectomy). It is, therefore, important to lay down fundamental and appropriate rules concerning the indications and contraindications for lung transplantation, especially in patients with cystic fibrosis. Aim: The aim of this study was to analyze the methods of qualifying and preparing patients for surgery, as well as carrying out the procedure of transplantation and postoperative short and long-term care. Material and methods: The investigation was carried out on 16 patients with cystic fibrosis. Three were operated on and 10 were on the waiting list for transplantation. Two patients on the waiting list died, one patient was disqualified from transplantation. During qualification for lung transplantation, strict indications, contraindications and other factors (such as blood type, patient’s height, coexisting complications) were taken under consideration. Results: All the 3 patients after lung transplantation are alive and under our constant surveillance. Ten patients await transplantation, though four of them are suspended due to hepatitis C infection. Two patients on the waiting list died: one from respiratory insufficiency and the other in the course of bridgeto-transplant veno-venous extracorporeal membrane oxygenation due to hepatic failure. One patient has been disqualified because of cachexia. Conclusions: Since lung transplantation is the final treatment of the end-stage pulmonary insufficiency in cystic fibrosis patients, the number of such procedures in cystic fibrosis is still too low in Poland. The fast development of these procedures is highly needed. It is necessary to develop better cooperation between different disciplines and specialists, especially between pediatricians and surgeons. The correct choice of the suitable moment for lung transplantation is crucial for the success of the procedure.
Wstęp: Punt widzenia chirurga odnośnie leczenia pacjenta z mukowiscydozą różni się od spojrzenia pediatry czy internisty. Duży jest bagaż zadań lekarza specjalisty w zakresie leczenia chorego z mukowiscydozą w różnych okresach choroby, a inny chirurga, który przejmuje go w bardzo zaawansowanym, a nierzadko w terminalnym stadium. Stąd dla chirurga głównym problemem jest podjęcie decyzji odnośnie leczenia operacyjnego (transplantacja płuc, pneumonektomia, lobektomia). Dlatego tak ważne jest sformułowanie podstawowych i właściwych zasad dotyczących wskazań i przeciwwskazań do transplantacji płuc zwłaszcza w odniesieniu do pacjentów z mukowiscydozą. Cel: Celem pracy była analiza metod kwalifikacji i przygotowania, a także przeprowadzenia transplantacji oraz pooperacyjnej opieki krótko- i długoterminowej. Materiał i metody: W niniejszej pracy przedstawiamy 3 przypadki pacjentów z mukowiscydozą po zabiegu transplantacji płuc oraz 10 kandydatów, którzy w chwili obecnej są potencjalnymi biorcami narządu i oczekują na jej przeprowadzenie. Dwóch pacjentów nie doczekało przeszczepienia, jedna pacjentka została zdyskwalifikowana z zabiegu. W toku kwalifikacji do transplantacji płuc omawiane są istniejące wskazania, przeciwwskazania i szereg innych czynników (takich jak grupa krwi, wysokość ciała pacjenta, istniejące powikłania choroby podstawowej, choroby współistniejące). Wyniki: Wszyscy (troje) pacjenci po przeprowadzonej transplantacji żyją i są pod stałą kontrolą naszego ośrodka. Z dziesięciu kandydatów oczekujących na przeszczepienie, czterech jest zawieszonych na liście oczekujących z powodu infekcji (wirusowe zapalenie wątroby typu C). Dwóch pacjentów nie doczekało przeszczepienia: pierwszy zmarł z powodu niewydolności oddechowej, adrugi kwalifikowany do przeszczepienia płuc iwątroby pozostający na pozaustrojowym natlenianiu membranowym żylno-żylnym, zmarł wskutek niewydolności wątroby. Jedna pacjentka została zdyskwalifikowana z zabiegu z powodu skrajnego niedoboru masy ciała. Wnioski: Biorąc pod uwagę, że transplantacja płuc jest ostatecznym leczeniem schyłkowej niewydolności oddechowej w mukowiscydozie. Liczba wykonywanych w Polsce przeszczepień płuc u chorych z mukowiscydozą jest ciągle za mała, o czym świadczy los oczekujących pacjentów. Konieczny jest więc szybki rozwój placówek zajmujących się przeszczepieniami płuc u tych chorych. Wybór odpowiedniego momentu przeprowadzenia transplantacji płuc, ma zasadnicze znaczenie dla powodzenia procedury.
Źródło:
Developmental Period Medicine; 2015, 1; 120-126
1428-345X
Pojawia się w:
Developmental Period Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radon intercomparison tests : Katowice, 2016
Autorzy:
Chałupnik, Stanisław
Skubacz, Krystian
Wysocka, Małgorzata
Mazur, Jadwiga
Bonczyk, Michał
Kozak, Krzysztof
Grządziel, Dominika
Urban, Paweł
Tchorz-Trzeciakiewicz, D.
Kozłowska, Beata
Walencik-Łata, Agata
Podstawczyńska, Agnieszka
Olszewski, Jerzy
Bartak, Jakub
Karpińska, Maria
Wołoszczuk, Katarzyna
Dohojda, Marek
Nowak, Jakub
Długosz-Lisiecka, Magdalena
Foerster, Elisabeth
Przylibski, Tadeusz A.
Powiązania:
https://bibliotekanauki.pl/articles/146183.pdf
Data publikacji:
2020
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
active monitors
passive monitors
Polish Radon Centre
proficiency test
radon
Opis:
At the beginning of the year 2016, the representatives of the Polish Radon Centre decided to organize proficiency tests (PTs) for measurements of radon gas and radon decay products in the air, involving radon monitors and laboratory passive techniques. The Silesian Centre for Environmental Radioactivity of the Central Mining Institute (GIG), Katowice, became responsible for the organization of the PT exercises. The main reason to choose that location was the radon chamber in GIG with a volume of 17 m3 , the biggest one in Poland. Accordingly, 13 participants from Poland plus one participant from Germany expressed their interest. The participants were invited to inform the organizers about what types of monitors and methods they would like to check during the tests. On this basis, the GIG team prepared the proposal for the schedule of exercises, such as the required level(s) of radon concentrations, the number and periods of tests, proposed potential alpha energy concentration (PAEC) levels and also the overall period of PT. The PT activity was performed between 6th and 17th June 2016. After assessment of the results, the agreement between radon monitors and other measurement methods was confirmed. In the case of PAEC monitors and methods of measurements, the results of PT exercises were consistent and confirmed the accuracy of the calibration procedures used by the participants. The results of the PAEC PTs will be published elsewhere; in this paper, only the results of radon intercomparison are described.
Źródło:
Nukleonika; 2020, 65, 2; 127-132
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies