Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kot, Tomáš" wg kryterium: Autor


Wyświetlanie 1-1 z 1
Tytuł:
Verification of electronic device technology for measurement and evaluation of thermal exposure of fire fighters and members of rescue teams
Autorzy:
Bernatíková, Šárka
Tomášková, Hana
Bužga, Marek
Jirák, Zdeněk
Novák, Petr
Babjak, Ján
Kot, Tomáš
Krys, Václav
Jánošík, Ladislav
Powiązania:
https://bibliotekanauki.pl/articles/2162587.pdf
Data publikacji:
2017-12-05
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
heart rate
correlation
body temperature
fire fighter
physical strain
thermal load
Opis:
Background The work of members of rescue teams could be associated with very high physical and thermal loads. If not timely interrupted, any extreme labour-thermal load may lead to a failure of the body and fatal collapse. This risk may be significantly reduced by devices that monitor the response of the body during the intervention and inform rescuers about the need to interrupt the exposure when the critical value of the reference indicator is achieved. The aim of the study was to test the correlation between the data of the newly developed device for signaling the strain of rescuers and the indicators of physiological response of the body. Material and Methods The tests were performed on 2 physically fit fire fighters dressed in a protective rescue suit and using insulating breathing apparatus, over a wide range of heat load under a model load on a bicycle ergometer in a climatic chamber. Results The study provided a significant correlation between the body temperature measured in the ear canal and the temperature under the suit sensed by the tested device – the Safety Ambient Monitor (SAM) (R = 0.9007). The temperature under the suit also correlated with the temperature of the chest skin (R = 0.8928) and heart rate (R = 0.8613). Conclusions A statistically significant correlation was proven between the temperature sensed by the SAM and the body temperature. The technical solution of sensing the temperature under the suit using the verified SAM technology does not affect or limit fire fighters in their work and minimizes the possibility of damage to the sensor and signaling failures. Med Pr 2018;69(1):1–11
Źródło:
Medycyna Pracy; 2018, 69, 1; 1-11
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies