Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Korzeniewski, P." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Morphology and the physical and thermal properties of thermoplastic polyurethane reinforced with thermally reduced graphene oxide
Autorzy:
Strankowski, M.
Piszczyk, Ł.
Kosmela, P.
Korzeniewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/779423.pdf
Data publikacji:
2015
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
nanocomposites
graphene
polyurethane
carbon nanofillers
TRG
Opis:
In this study, thermally reduced graphene oxide (TRG)-containing polyurethane nanocomposites were obtained by the extrusion method. The content of TRG incorporated into polyurethane elastomer systems equaled 0.5, 1.0, 2.0 and 3.0 wt%. The morphology, static and dynamic mechanical properties, and thermal stability of the modified materials were investigated. The application of TRG resulted in a visible increase in material stiffness as confirmed by the measurements of complex compression modulus (E′) and glass transition temperature (Tg). The Tg increased with increasing content of nanofiller in the thermoplastic system. The addition of thermally reduced graphene oxide had a slight effect on thermal stability of the obtained materials. The incorporation of 0.5, 1.0, 2.0 and 3.0 wt% of TRG into a system resulted in increased char residues compared to unmodified PU elastomer. Also, this study demonstrated that after exceeding a specific amount of TRG, the physicomechanical properties of modified materials start to deteriorate.
Źródło:
Polish Journal of Chemical Technology; 2015, 17, 4; 88-94
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektryczny Pojazd Balansujący - realizacja praktyczna
Balancing Electric Vehicle - practical implementation
Autorzy:
Falkowski, P.
Korzeniewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/157920.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
Segway
MEMS
ARM
pojazd elektryczny
LabVIEW
electric vehicle
Opis:
W artykule opisano zasadę działania oraz budowę Elektrycznego Pojazdu Balansującego. Zbudowany pojazd został skonstruowany przez studentów Koła Naukowego Techniki Mikroprocesorowej w Energoelektronice, którzy zostali zainspirowani seryjnie produkowanym pojazdem. W artykule omówiony został zaprojektowany i wykonany układ sterujący, którego głównymi elementami są czujniki MEMS. Przedstawiono w nim opracowany algorytm sterujący pracą silników elektrycznych odpowiedzialnych za poruszanie się pojazdu i utrzymywanie pozycji pionowej.
This paper presents the Electric Balancing Vehicle, which has been designed based on the standard Personal Transporter produced by Segway®. This vehicle is unstable, because of the fact that its centre of gravity is above the axis of rotation, which causes the effect of an inverted pendulum (Fig. 1). In order to hold the vehicle in a vertical position (Y axis in Fig. 1a), it is necessary to provide the continuous, active regulation by proper control of a torque to the wheels. Fig. 2 shows the block diagram of the control system, where control of the inclination angle is the primary control loop. The method of determining the angle of the platform is shown in Fig. 5. The main part of the vehicle control system (Figs. 3 and 4) is a 32-bit Micro-controller STM32F103 from STMicroelectronis. Its main tasks are: collecting data from voltage and current MEMS sensors, executing the control algorithm (Fig. 2) and controlling the electric motors. The wheel drive uses two DC brushed motors with permanent magnets (each of 750W power), controlled by DC/DC converters (Fig. 6) with the option of returning the energy to batteries during a braking process. The data such as angle and motor currents are sent through a Bluetooth module to a PC and displayed in LabVIEW (Fig. 9).
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 12, 12; 1285-1288
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Properties of active rectifier with LCL filter in the selection process of the weighting factors in finite control set-MPC
Autorzy:
Falkowski, P.
Sikorski, A.
Kulikowski, K.
Korzeniewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/200718.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
model predictive control (MPC)
active front end converters
inductive-capacitive-inductive (LCL) filter
weighting factors selection
Opis:
One of the main problems of multivariable cost functions in model predictive control is the choice of weighting factors. Two finite control set model predictive control algorithms, applied to the three-phase active rectifier with an LCL filter, are described in the paper. The investigated algorithms, i.e. PCicuc and PCigicuc, implement multivariable approaches applying line (grid) current, capacitor voltage and converter current. The main problem dealt with in the paper is the choice of optimum values of the cost function weighting factors. The values of the factors calculated using the method proposed in the paper are very close to the values represented by the lowest THDi of the line current. Moreover, simulations verifying the equations used in the prediction of controlled values, i.e. line current, capacitor voltage and converter current, are presented. Both simulation and experimental results are presented to verify effectiveness of the investigated control strategies under change of the load (P = 5 kW and 2.5 kW), during transient states, under unbalanced and balanced line voltage.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 1; 51-60
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ nurkowania na PAI - 1 I ALFA2-antyplazminy oraz aktywność fibrynolityczna
Decreased levels of PAI-1 and alpha2-antiplasmin contribute to enhanced fibrynolitic activity in divers
Autorzy:
Radziwon, P.
Olszański, R.
Tomaszewski, R.
Lipska, A.
Dąbrowiecki, Z.
Korzeniewski, K.
Siermontowski, P.
Boczkowska-Radziwon, B
Powiązania:
https://bibliotekanauki.pl/articles/366342.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
alfa2-antyplazmina
choroba dekompresyjna
PAI-1
PAP
t-PA
alpha2-antiplasmin
decompression sickness
Opis:
Praca mówi o nie zbadanych dotychczas dokładnie powiązaniach choroby dekompresyjnej z zagadnieniami hemostazy a szczególnie fibrynolizy. Badany był wpływ ekspozycji hiperbarycznej na główne składniki systemu fibrynolizy. Dwie grupy młodych mężczyzn poddawane były ekspozycjom hierbarycznym do ciśnienia 400 kPa - grupa I - i 700 kPa - grupa II. Stosowano dekompresję powietrzna. Po ekspozycji badano nurków na obecność objawów choroby dekompresyjnej, a także poszukiwano pęcherzyków gazu w naczyniach żylnych metoda Dopplera. 15 minut po zakończeniu dekompresji pobierano krew do badań koagulologicznych. Badano stężenie i aktywność t-PA i PAI-1, stężenie PAP i alfa2-antyplazminy. W grupach badawczych nie stwierdzono wykładników choroby dekompresyjnej ani nadmiernej ilości pęcherzyków wewnątrznaczyniowych. Stwierdzono miedzy innymi spadek poziomu alfa2-antyplazminy, spadek stężenia i aktywności PAI-1. Nie zaobserwowano zmian w zakresie czynnika XII jak i t-PA. Ekspozycja hiperbaryczna i dekompresja indukuje fibrynolize, nawet bez obecności pęcherzyków gazowych.
There are a number of reported cases of decompression sickness (DCS) with haemorrhages. These cases have not been sufficiently investigated and thus bleeding complications could not be directly correlated to the enhanced fibrinolysis. The effect of hyperbaric exposition and decompression on the main components of fibrynolitic system have been measured. Two groups of 25 male divers each, were subjected to hyperbaric exposures to the pressure of either 400 kPa - group I - or 700 kPa - group II followed by a staged decompression. The divers were monitored for clinical symptoms of DCS and checked for Doppler-detected venous gas bubbles. Venous blood was drawn from divers before exposition and 15 minutes after decompression. The concentrations and activities of t-PA and PAI-1 as well as concentrations of PAP and alpha2-antiplasmin and activity of factor XIIa were measured. In all groups of divers no cases of DCS as well as detectable gas bubbles were noted. We observed elevated concentration of PAP, decreased concentration of alpha2-AP, decreased PAI-1 concentration and activity. There were no significant changes in factor XIIa activity as well a of t- PA concentration and activity. Hyperbaric exposition and decompression induce activation of fibrynolisis, even in the absence of detectable gas bubbles. Fibrynolitic activity increases mainly due to decrease of PAI-1 concentration and activity. Further clinical trials are necessary for the estimation of the importance of activation of fibrynolisis with decreased level of PAI-1 and alpha2-AP as possible risk factor for bleeding in divers.
Źródło:
Polish Hyperbaric Research; 2007, 3(20); 33-42
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies